MYMonisha Yuvaraj

Monisha Yuvaraj

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Monisha Yuvaraj has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    What percentage of severely impaired stroke survivors retain residual voluntary EMG?

    by Monisha Yuvaraj, Steffi Graff, Prabhakar Appaswamy Thirumal, Sanjith Aaron, Ander Ramos-Murguialday, Nebojsa Malesevic, Christian Antfolk, Etienne Burdet, Skm Varadhan, Sivakumar Balasubramanian

    Back-ground: Beneficial rehabilitation interventions for severely impaired stroke patients are limited. Owing to practical constraints in the routine clinical use of electroencephalogram (EEG)-based brain-computer interfaces, this study investigates the feasibility of using a more practical electromyography (EMG) to detect movement intention in severe stroke subjects without visible movement. Currently, no large-scale studies provide strong evidence in favour of EMG-based human-machine interaction for closed-loop control of robotic assistance for severe stroke. Objective: To screen severely impaired stroke subjects without active wrist extension for the presence of residual EMG activity. Methods: High-density surface EMG was recorded from the wrist extensor muscles of 100 severely impaired stroke survivors while they repeatedly attempted wrist extension. EMG activity during “Rest” and “Move” states was compared, and subjects showing statistically greater muscle activity during Move than Rest were classified as having residual EMG. A modified Hodges detector combined with the probability difference-sum ratio (PDSR) was used for classification, with a threshold of 0.73 identifying subjects with residual EMG. Results: Of the 100 subjects without active wrist extension (Muscle power: MRC < 2), 64 exhibited residual EMG activity, supporting the feasibility of EMG for movement intention detection. Among these, 35 demonstrated consistent muscle activity (Detection probability > 0.2); representing suitable candidates for EMG-driven robot-assisted therapy. Conclusions: A substantial proportion of severely impaired stroke subjects without active movement could benefit from a simpler EMG-based interface for robot-assisted therapy. Distinct neural mechanisms (intact voluntary drive or abnormal co-activation) may contribute to the residual muscle activity, which should be considered while designing control strategies.

  • Open Access

    Identification of Subject-Specific EMG Detectors for Robot-Assisted Therapy Using Rest and Move State EMG Data

    by Monisha Yuvaraj, At Prabhakar, Varadhan Skm, Etienne Burdet, Ander Ramos-Murguialday, Sivakumar Balasubramanian

    In severely impaired stroke patients without visible movements, implementing robot-assisted therapy based on movement intention decoded from electromyogram (EMG) requires both sufficient residual EMG to drive robotic assistance and a patient-specific detector to ensure accurate, low-latency detection. However, identifying such a detector is challenging, particularly when the presence of residual EMG in a given patient is unknown. This paper proposes a systematic approach to distinguish between EMG data when the patient is relaxed versus attempting a movement.We investigated six different detector types and separation measures using retrospective EMG data from a previous randomized controlled trial. The results indicate that the approximate generalized likelihood ratio (AGLR) detector, along with the modified Hodges and modified Lidierth detectors, achieved the best separation between the data when a subject is relaxed compared to when he/she attempts movements. Using a subset of clinician-annotated data to evaluate detection performance, the modified Hodges detector combined with probability difference-sum ratio measure (MH-PDSR) showed good performance in terms of both accuracy and latency. Based on the EMG data from 30 severe stroke, we propose a PDSR threshold of 0.7 with the modified Hodges detector to identify patients with sufficient residual EMG. These findings suggest that the MH-PDSR approach can be used to learn a maximally separating detector for a given patient which can be used both to screen patients for residual EMG and to provide a detector to drive robotic assistance if residual EMG is present. Further validation using larger datasets and evaluation of the resulting human machine interaction is warranted.


  • Open Access

    A systematic investigation of detectors for low signal-to-noise ratio EMG signals

    by Monisha Yuvaraj, Priyanka Raja, Ann David, Etienne Burdet, Varadhan Skm, Sivakumar Balasubramanian

    Background Active participation of stroke survivors during robot-assisted movement therapy is essential for sensorimotor recovery. Robot-assisted therapy contingent on movement intention is an effective way to encourage patients’ active engagement. For severely impaired stroke patients with no residual movements, a surface electromyogram (EMG) has been shown to be a viable option for detecting movement intention. Although numerous algorithms for EMG detection exist, the detector with the highest accuracy and lowest latency for low signal-to-noise ratio (SNR) remains unknown. Methods This study, therefore, investigates the performance of 13 existing EMG detection algorithms on simulated low SNR (0dB and -3dB) EMG signals generated using three different EMG signal models: Gaussian, Laplacian, and biophysical model. The detector performance was quantified using the false positive rate (FPR), false negative rate (FNR), and detection latency. Any detector that consistently showed FPR and FNR of no more than 20%, and latency of no more than 50ms, was considered an appropriate detector for use in robot-assisted therapy. Results The results indicate that the Modified Hodges detector – a simplified version of the threshold-based Hodges detector introduced in the current study – was the most consistent detector across the different signal models and SNRs. It consistently performed for ~90% and ~40% of the tested trials for 0dB and -3dB SNR, respectively. The two statistical detectors (Gaussian and Laplacian Approximate Generalized Likelihood Ratio) and the Fuzzy Entropy detectors have a slightly lower performance than Modified Hodges. Conclusions Overall, the Modified Hodges, Gaussian and Laplacian Approximate Generalized Likelihood Ratio, and the Fuzzy Entropy detectors were identified as the potential candidates that warrant further investigation with real surface EMG data since they had consistent detection performance on low SNR EMG data.


  • Open Access

    A systematic investigation of detectors for low signal-to-noise ratio EMG signals

    by Monisha Yuvaraj, Priyanka Raja, Ann David, Etienne Burdet, Varadhan Skm, Sivakumar Balasubramanian

    Background Active participation of stroke survivors during robot-assisted movement therapy is essential for sensorimotor recovery. Robot-assisted therapy contingent on movement intention is an effective way to encourage patients’ active engagement. For severely impaired stroke patients with no residual movements, a surface electromyogram (EMG) has been shown to be a viable option for detecting movement intention. Although numerous algorithms for EMG detection exist, the detector with the highest accuracy and lowest latency for low signal-to-noise ratio (SNR) remains unknown. Methods This study, therefore, investigates the performance of 13 existing EMG detection algorithms on simulated low SNR (0dB and -3dB) EMG signals generated using three different EMG signal models: Gaussian, Laplacian, and biophysical model. The detector performance was quantified using the false positive rate (FPR), false negative rate (FNR), and detection latency. Any detector that consistently showed FPR and FNR of no more than 20%, and latency of no more than 50ms, was considered an appropriate detector for use in robot-assisted therapy. Results The results indicate that the Modified Hodges detector – a simplified version of the threshold-based Hodges detector introduced in the current study – was the most consistent detector across the different signal models and SNRs. It consistently performed for ~90% and ~40% of the tested trials for 0dB and -3dB SNR, respectively. The two statistical detectors (Gaussian and Laplacian Approximate Generalized Likelihood Ratio) and the Fuzzy Entropy detectors have a slightly lower performance than Modified Hodges. Conclusions Overall, the Modified Hodges, Gaussian and Laplacian Approximate Generalized Likelihood Ratio, and the Fuzzy Entropy detectors were identified as the potential candidates that warrant further investigation with real surface EMG data since they had consistent detection performance on low SNR EMG data.

  • Open Access

    A systematic investigation of detectors for low signal-to-noise ratio EMG signals

    by Monisha Yuvaraj, Priyanka Raja, Ann David, Etienne Burdet, Varadhan Skm, Sivakumar Balasubramanian

    Background Active participation of stroke survivors during robot-assisted movement therapy is essential for sensorimotor recovery. Robot-assisted therapy contingent on movement intention is an effective way to encourage patients’ active engagement. For severely impaired stroke patients with no residual movements, a surface electromyogram (EMG) has been shown to be a viable option for detecting movement intention. Although numerous algorithms for EMG detection exist, the detector with the highest accuracy and lowest latency for low signal-to-noise ratio (SNR) remains unknown. Methods This study, therefore, investigates the performance of 13 existing EMG detection algorithms on simulated low SNR (0dB and -3dB) EMG signals generated using three different EMG signal models: Gaussian, Laplacian, and biophysical model. The detector performance was quantified using the false positive rate (FPR), false negative rate (FNR), and detection latency. Any detector that consistently showed FPR and FNR of no more than 20%, and latency of no more than 50ms, was considered an appropriate detector for use in robot-assisted therapy. Results The results indicate that the Modified Hodges detector – a simplified version of the threshold-based Hodges detector introduced in the current study – was the most consistent detector across the different signal models and SNRs. It consistently performed for ~90% and ~40% of the tested trials for 0dB and -3dB SNR, respectively. The two statistical detectors (Gaussian and Laplacian Approximate Generalized Likelihood Ratio) and the Fuzzy Entropy detectors have a slightly lower performance than Modified Hodges. Conclusions Overall, the Modified Hodges, Gaussian and Laplacian Approximate Generalized Likelihood Ratio, and the Fuzzy Entropy detectors were identified as the potential candidates that warrant further investigation with real surface EMG data since they had consistent detection performance on low SNR EMG data.

  • Open Access

    A systematic investigation of detectors for low signal-to-noise ratio EMG signals

    by Monisha Yuvaraj, Priyanka Raja, Ann David, Etienne Burdet, Varadhan Skm, Sivakumar Balasubramanian

    Background: Active participation of stroke survivors during robot-assisted movement therapy is essential for sensorimotor recovery. Robot-assisted therapy contingent on movement intention is an effective way to encourage patients' active engagement. For severely impaired stroke patients with no residual movements, a surface electromyogram (EMG) has been shown to be a viable option for detecting movement intention. Although numerous algorithms for EMG detection exist, the detector with the highest accuracy and lowest latency for low signal-to-noise ratio (SNR) remains unknown. Methods: This study, therefore, investigates the performance of 13 existing EMG detection algorithms on simulated low SNR (0dB and -3dB) EMG signals generated using three different EMG signal models: gaussian, Laplacian, and biophysical model. The detector performance was quantified using the false positive rate (FPR), false negative rate (FNR), and detection latency. Any detector that consistently showed FPR and FNR of no more than 20%, and latency of no more than 50ms, was considered an appropriate detector for use in robot-assisted therapy. Results: The results indicate that the Modified Hodges detector – a simplified version of the threshold-based Hodges detector introduced in the current study – was the most consistent detector across the different signal models and SNRs. It consistently performed for ~90% and ~40% of the tested trials for 0dB and -3dB SNR, respectively. The two statistical detectors (Gaussian and Laplacian Approximate Generalized Likelihood Ratio) and the Fuzzy Entropy detectors have a slightly lower performance than Modified Hodges. Conclusions: Overall, the Modified Hodges, Gaussian and Laplacian Approximate Generalized Likelihood ratio, and the Fuzzy Entropy detectors were identified as the potential candidates that warrant further investigation with real surface EMG data since they had consistent detection performance on low SNR EMG data.