CFClaire Floras

Claire Floras

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Claire Floras has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Carlos Ziebert

    Karlsruhe Institute of Technology (KIT), Institute for Applied Materials-Applied Materials Physics (IAM-AWP), Kaiserstraße 12, 76131 Karlsruhe, Germany

    1 shared publication
  • Hans Jürgen Seifert

    Karlsruhe Institute of Technology, Institute for Applied Materials-Applied Materials Physics, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany

    1 shared publication
  • Niklas Lubenau

    Karlsruhe Institute of Technology (KIT), Institute for Applied Materials-Applied Materials Physics (IAM-AWP), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany

    1 shared publication
  • Nils Uhlmann

    Karlsruhe Institute of Technology (KIT), Institute for Applied Materials-Applied Materials Physics (IAM-AWP), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany

    1 shared publication
  • Philipp Finster

    Karlsruhe Institute of Technology (KIT), Institute for Applied Materials-Applied Materials Physics (IAM-AWP), Kaiserstraße 12, 76131 Karlsruhe, Germany

    1 shared publication
  • Sebastian Ohneseit

    Institute for Applied Materials‐Applied Materials Physics (IAM‐AWP) Karlsruhe Institute of Technology (KIT) Hermann‐von‐Helmholtz‐Platz 1 76344 Eggenstein‐Leopoldshafen Germany

    1 shared publication

Latest Publications

  • Open Access

    Contact Lens-Based Intraocular Pressure Sensor

    by Syed Ali Raza Bukhari, Tanzila Afrin, Claire Floras, Yongjun Lai

    The intraocular pressure (IOP) is the principal indicator for diagnosis of glaucoma which is one of the leading causes of blindness. The IOP can vary throughout the day, and traditional methods of measuring it in a clinical setting only provide a fraction of the patient’s IOP pattern. This article presents a cost-effective way for continuous monitoring of IOP by utilizing a soft contact lens with strategically placed holes. The deformation of these holes due to the change in IOP can be used to detect the pressure variations throughout the day. Extensive COMSOL Multiphysics simulations are conducted to optimize the design and to test the viability of this method. The optimized lens design can achieve a large deformation ratio sensitivity of 0.39 per mmHg with an applied pressure range of 10 mmHg to 40 mmHg.


  • Open Access

    Thermal and Mechanical Safety Assessment of Type 21700 Lithium-Ion Batteries with NMC, NCA and LFP Cathodes–Investigation of Cell Abuse by Means of Accelerating Rate Calorimetry (ARC)

    by Sebastian Ohneseit, Philipp Finster, Claire Floras, Niklas Lubenau, Nils Uhlmann, Hans Jürgen Seifert, Carlos Ziebert

    In this experimental investigation, we studied the safety and thermal runaway behavior of commercial lithium-ion batteries of type 21700. The different cathode materials NMC, NCA and LFP were compared, as well as high power and high energy cells. After characterization of all relevant components of the batteries to assure comparability, two abuse methods were applied: thermal abuse by the heat-wait-seek test and mechanical abuse by nail penetration, both in an accelerating rate calorimeter. Several critical temperatures and temperature rates, as well as exothermal data, were determined. Furthermore, the grade of destruction, mass loss and, for the thermal abuse scenario, activation energy and enthalpy, were calculated for critical points. It was found that NMC cells reacted first, but NCA cells went into thermal runaway a little earlier than NMC cells. LFP cells reacted, as expected, more slowly and at significantly higher temperatures, making the cell chemistry considerably safer. For mechanical abuse, no thermal runaway was observed for LFP cells, as well as at state of charge (SOC) zero for the other chemistries tested. For thermal abuse, at SOC 0 and SOC 30 for LFP cells and at SOC 0 for the other cell chemistries, no thermal runaway occurred until 350 °C. In this study, the experimental data are provided for further simulation approaches and system safety design.