Salvador Barrera-Figueroa
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Salvador Barrera-Figueroa has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Knud Rasmussen
Danish Primary Laboratory of Acoustics Danish Fundamental Metrology Matematiktorvet 307, 2800 Kongens Lyngby, Denmark
4 shared publicationsFinn Jacobsen
Technical University of Denmark Acoustic Technology, Department of Electrical Engineering Ørsteds Plads 352, 2800 Kongens Lyngby, Denmark
3 shared publications- Finn Jacobsen
Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Building 352, DK-2800 Kongens Lyngby, Denmark
1 shared publication
Latest Publications
- 1 April 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 127 (4) , 2290-2294
Radiation impedance of condenser microphones and their diffuse-field responses
The relation between the diffuse-field response and the radiation impedance of a microphone has been investigated. Such a relation can be derived from classical theory. The practical measurement of the radiation impedance requires (a) measuring the volume velocity of the membrane of the microphone and (b) measuring the pressure on the membrane of the microphone. The first measurement is carried out by means of laser vibrometry. The second measurement cannot be implemented in practice. However, the pressure on the membrane can be calculated numerically by means of the boundary element method. In this way, a hybrid estimate of the radiation impedance is obtained. The resulting estimate of the diffuse-field response is compared with experimental estimates of the diffuse-field response determined using reciprocity and the random-incidence method. The different estimates are in good agreement at frequencies below the resonance frequency of the microphone. Although the method may not be of great practical utility, it provides a useful validation of the estimates obtained by other means.
- 1 April 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 127 (4) , 2290-2294
Radiation impedance of condenser microphones and their diffuse-field responses
The relation between the diffuse-field response and the radiation impedance of a microphone has been investigated. Such a relation can be derived from classical theory. The practical measurement of the radiation impedance requires (a) measuring the volume velocity of the membrane of the microphone and (b) measuring the pressure on the membrane of the microphone. The first measurement is carried out by means of laser vibrometry. The second measurement cannot be implemented in practice. However, the pressure on the membrane can be calculated numerically by means of the boundary element method. In this way, a hybrid estimate of the radiation impedance is obtained. The resulting estimate of the diffuse-field response is compared with experimental estimates of the diffuse-field response determined using reciprocity and the random-incidence method. The different estimates are in good agreement at frequencies below the resonance frequency of the microphone. Although the method may not be of great practical utility, it provides a useful validation of the estimates obtained by other means.
- 1 October 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 126 (4) , 1788-1795
Hybrid method for determining the parameters of condenser microphones from measured membrane velocities and numerical calculations
Typically, numerical calculations of the pressure, free-field, and random-incidence response of a condenser microphone are carried out on the basis of an assumed displacement distribution of the diaphragm of the microphone; the conventional assumption is that the displacement follows a Bessel function. This assumption is probably valid at frequencies below the resonance frequency. However, at higher frequencies the movement of the membrane is heavily coupled with the damping of the air film between membrane and backplate and with resonances in the back chamber of the microphone. A solution to this problem is to measure the velocity distribution of the membrane by means of a non-contact method, such as laser vibrometry. The measured velocity distribution can be used together with a numerical formulation such as the boundary element method for estimating the microphone response and other parameters, e.g., the acoustic center. In this work, such a hybrid method is presented and examined. The velocity distributions of a number of condenser microphones have been determined using a laser vibrometer, and these measured velocity distributions have been used for estimating microphone responses and other parameters. The agreement with experimental data is generally good. The method can be used as an alternative for validating the parameters of the microphones determined by classical calibration techniques.
- 1 October 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 126 (4) , 1788-1795
Hybrid method for determining the parameters of condenser microphones from measured membrane velocities and numerical calculations
Typically, numerical calculations of the pressure, free-field, and random-incidence response of a condenser microphone are carried out on the basis of an assumed displacement distribution of the diaphragm of the microphone; the conventional assumption is that the displacement follows a Bessel function. This assumption is probably valid at frequencies below the resonance frequency. However, at higher frequencies the movement of the membrane is heavily coupled with the damping of the air film between membrane and backplate and with resonances in the back chamber of the microphone. A solution to this problem is to measure the velocity distribution of the membrane by means of a non-contact method, such as laser vibrometry. The measured velocity distribution can be used together with a numerical formulation such as the boundary element method for estimating the microphone response and other parameters, e.g., the acoustic center. In this work, such a hybrid method is presented and examined. The velocity distributions of a number of condenser microphones have been determined using a laser vibrometer, and these measured velocity distributions have been used for estimating microphone responses and other parameters. The agreement with experimental data is generally good. The method can be used as an alternative for validating the parameters of the microphones determined by classical calibration techniques.
- 1 September 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 124 (3) , 1505-1512
A note on determination of the diffuse-field sensitivity of microphones using the reciprocity technique
The diffuse-field response of a microphone is usually obtained by adding a random-incidence correction to the pressure response of the microphone. However, the random-incidence correction is determined from a relative measurement, and its accuracy depends not only on the relative response at all angles of incidence but also on the accuracy of the frequency response at normal incidence. By contrast, this paper is concerned with determining the absolute diffuse-field response of a microphone using the reciprocity technique. To examine this possibility, a reciprocity calibration setup is used for measuring the electrical transfer impedance between a pair of microphones placed in a miniature (2 m(3)) reverberation room. The transfer function between the microphones is measured using fast Fourier transform analysis and pseudorandom noise. The calculation of the diffuse-field sensitivity involves (a) separation of the reverberant response from the total response, (b) determination of the reverberation time, and (c) averaging over space and frequency. The resulting diffuse-field correction is compared with an estimate of the random-incidence correction determined in an anechoic room and with a numerical prediction. (C) 2008 Acoustical Society of America.
- 1 September 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 124 (3) , 1505-1512
A note on determination of the diffuse-field sensitivity of microphones using the reciprocity technique
The diffuse-field response of a microphone is usually obtained by adding a random-incidence correction to the pressure response of the microphone. However, the random-incidence correction is determined from a relative measurement, and its accuracy depends not only on the relative response at all angles of incidence but also on the accuracy of the frequency response at normal incidence. By contrast, this paper is concerned with determining the absolute diffuse-field response of a microphone using the reciprocity technique. To examine this possibility, a reciprocity calibration setup is used for measuring the electrical transfer impedance between a pair of microphones placed in a miniature (2 m(3)) reverberation room. The transfer function between the microphones is measured using fast Fourier transform analysis and pseudorandom noise. The calculation of the diffuse-field sensitivity involves (a) separation of the reverberant response from the total response, (b) determination of the reverberation time, and (c) averaging over space and frequency. The resulting diffuse-field correction is compared with an estimate of the random-incidence correction determined in an anechoic room and with a numerical prediction. (C) 2008 Acoustical Society of America.
- 1 May 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 121 (5) , 2628-2636
On experimental determination of the random-incidence response of microphones
The random-incidence sensitivity of a microphone is defined as the ratio of the output voltage to the sound pressure that would exist at the position of the acoustic center of the microphone in the absence of the microphone in a sound field with incident plane waves coming from all directions. The random-incidence correction of a number of laboratory standard microphones has been determined experimentally. Although the measurement procedure seems to be straightforward, some practical and fundamental problems arise: (i) Reflections from the mounting rig contaminate the measured frequency response, and whereas some of these reflections can be removed using a time-selective technique, others coincide with the direct impulse response and consequently cannot be removed in the time domain and thus affect the accuracy of the estimate; (ii) the accuracy of the estimate is relying on the rotational symmetry of the microphone and depends on the angular resolution. The effect of the angular resolution has been compared with the analytical solution of the scattering and diffraction around a solid sphere. Numerical calculations supplement the experimental results. Although the procedure has only been applied to laboratory standard microphones, it is not restricted to such microphones and may be applied to other types of measurement microphones.
- 1 May 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 121 (5) , 2628-2636
On experimental determination of the random-incidence response of microphones
The random-incidence sensitivity of a microphone is defined as the ratio of the output voltage to the sound pressure that would exist at the position of the acoustic center of the microphone in the absence of the microphone in a sound field with incident plane waves coming from all directions. The random-incidence correction of a number of laboratory standard microphones has been determined experimentally. Although the measurement procedure seems to be straightforward, some practical and fundamental problems arise: (i) Reflections from the mounting rig contaminate the measured frequency response, and whereas some of these reflections can be removed using a time-selective technique, others coincide with the direct impulse response and consequently cannot be removed in the time domain and thus affect the accuracy of the estimate; (ii) the accuracy of the estimate is relying on the rotational symmetry of the microphone and depends on the angular resolution. The effect of the angular resolution has been compared with the analytical solution of the scattering and diffraction around a solid sphere. Numerical calculations supplement the experimental results. Although the procedure has only been applied to laboratory standard microphones, it is not restricted to such microphones and may be applied to other types of measurement microphones.