Hoang P. Dang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hoang P. Dang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Hugo Nestor Villegas Pico
Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA
4 shared publications - Abdelrahman M. Mannan
Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA
1 shared publication - Christopher L. Peralta
Iowa State University, Ames, IA, USA
1 shared publication - Zhenghan Zhang
Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA
1 shared publication
Latest Publications
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 16 (4) , 2414-2433
Control Design and EMT Simulation Toward the Restoration of Faulted Wind-Dominant Grids
Present power engineers have been challenged to employ electromagnetic transient (EMT) simulations to study the restoration of wind-dominant grids. This paper addresses this hurdle by developing strategies to: (i) reliably control the dc-link voltage of grid-forming wind turbines with dc-coupled batteries, (ii) tune controllers to stably interconnect wind power plants into a grid under recovery, and (iii) autonomously make restoration decisions even if transmission faults occur. These contributions are assessed via EMT simulations of wind-dominant versions of the WSCC 9-bus grid and a 22-bus power system. This paper is significant to address recommendations by the North American Electric Reliability Corporation.
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 16 (4) , 2414-2433
Control Design and EMT Simulation Toward the Restoration of Faulted Wind-Dominant Grids
Present power engineers have been challenged to employ electromagnetic transient (EMT) simulations to study the restoration of wind-dominant grids. This paper addresses this hurdle by developing strategies to: (i) reliably control the dc-link voltage of grid-forming wind turbines with dc-coupled batteries, (ii) tune controllers to stably interconnect wind power plants into a grid under recovery, and (iii) autonomously make restoration decisions even if transmission faults occur. These contributions are assessed via EMT simulations of wind-dominant versions of the WSCC 9-bus grid and a 22-bus power system. This paper is significant to address recommendations by the North American Electric Reliability Corporation.
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 12 (2) , 63-70
Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology
The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. This has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 12 (2) , 63-70
Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology
The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. This has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (3) , 1613-1629
FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration
Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed-voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. These contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (3) , 1613-1629
FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration
Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed-voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. These contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.
- 12 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (3) , 2060-2074
Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines
Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. The controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.
- 12 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (3) , 2060-2074
Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines
Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. The controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.