Minh Ha Tran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Minh Ha Tran has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Baowei Fei
University of Texas at Dallas, Center for Imaging and Surgical Innovation, Richardson, Texas, United States
8 shared publications - Ling Ma
University of Texas at Dallas, Center for Imaging and Surgical Innovation, Richardson, Texas, United States
5 shared publications - Michelle Bryarly
University of Texas at Dallas, Department of Bioengineering, Richardson, Texas, United States
4 shared publications - Hasan Mubarak
University of Texas at Dallas, Department of Bioengineering, Richardson, Texas
3 shared publications Arrsh Ali
Department of Bioengineering, University of Texas at Dallas, Richardson, TX
2 shared publicationsAria Jahadi
Center for Imaging and Surgical Innovation, University of Texas at Dallas, Richardson, TX 75080
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-127
Medical hyperspectral imaging: an updated review of technology advancements and biomedical applications
SignificanceHyperspectral imaging (HSI) is an advanced spectral imaging technique that captures spatial and spectral information across numerous wavelength bands. This capability allows tissue characterization, disease detection and diagnosis, surgical guidance, and digital histopathology, making it an increasingly valuable tool with wide biological and medical applications.AimWe aim to provide readers with (1) an understanding of the principles and technological advancements in HSI, (2) a comprehensive overview of HSI data processing and analysis methods, and (3) an updated survey of biomedical applications, from disease detection, intraoperative imaging, to histopathology.ApproachA systematic literature search was conducted using PubMed and Google Scholar with the keyword “hyperspectral imaging.” We previously published a comprehensive review paper on medical HSI in 2014, which was widely cited in the field. Therefore, this updated review focused on new technology advancements and emerging applications. Based on their biological and medical relevance, 612 HSI papers were included and analyzed in this review.ResultsRecent advances in HSI span both hardware and computational techniques, including improvements in sensor technology, data processing and analysis, short-wave near-infrared imaging, and deep-learning and AI tools. HSI is actively explored for various applications in oncology, neurology, ophthalmology, dermatology, cardiology, gastroenterology, hepatology, wound care, endocrinology, dentistry, infectious disease, plastic and reconstructive surgery, general surgery, intraoperative guidance, histopathology, microbiology, nanopathology, and pharmacology.ConclusionsHSI has become an emerging imaging modality in biomedical research and clinical settings. Continued advancements in hardware miniaturization, computational efficiency, and clinical validation will further solidify the role of next-generation HSI in biomedicine.
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-127
Top Cited PapersOpen AccessMedical hyperspectral imaging: an updated review of technology advancements and biomedical applications
SignificanceHyperspectral imaging (HSI) is an advanced spectral imaging technique that captures spatial and spectral information across numerous wavelength bands. This capability allows tissue characterization, disease detection and diagnosis, surgical guidance, and digital histopathology, making it an increasingly valuable tool with wide biological and medical applications.AimWe aim to provide readers with (1) an understanding of the principles and technological advancements in HSI, (2) a comprehensive overview of HSI data processing and analysis methods, and (3) an updated survey of biomedical applications, from disease detection, intraoperative imaging, to histopathology.ApproachA systematic literature search was conducted using PubMed and Google Scholar with the keyword “hyperspectral imaging.” We previously published a comprehensive review paper on medical HSI in 2014, which was widely cited in the field. Therefore, this updated review focused on new technology advancements and emerging applications. Based on their biological and medical relevance, 612 HSI papers were included and analyzed in this review.ResultsRecent advances in HSI span both hardware and computational techniques, including improvements in sensor technology, data processing and analysis, short-wave near-infrared imaging, and deep-learning and AI tools. HSI is actively explored for various applications in oncology, neurology, ophthalmology, dermatology, cardiology, gastroenterology, hepatology, wound care, endocrinology, dentistry, infectious disease, plastic and reconstructive surgery, general surgery, intraoperative guidance, histopathology, microbiology, nanopathology, and pharmacology.ConclusionsHSI has become an emerging imaging modality in biomedical research and clinical settings. Continued advancements in hardware miniaturization, computational efficiency, and clinical validation will further solidify the role of next-generation HSI in biomedicine.
- Open Access
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-19
Development and validation of a high-resolution hyperspectral imaging system for the retina
SignificanceEarly detection of Alzheimer’s diseases, diabetic retinopathy, or macular degeneration with advanced retinal imaging technologies can help improve patient care and treatment outcome.AimWe aim to create a high-resolution hyperspectral imaging (HSI) system for the retina. Retinal vessel diameter and oxygenation rate will be extracted simultaneously from HSI data.ApproachOur hyperspectral retinal imaging system consists of a snapshot hyperspectral camera, a high-resolution RGB camera, a beamsplitter, and an imaging endoscope. Multiple pansharpening algorithms, including deep learning methods, were developed to generate high-resolution hyperspectral images that were further used for the measurement of vessel size and oxygenation rate in mice.ResultsThe hyperspectral retinal imaging system was tested for its spatial resolution and spectral fidelity in retina phantoms. In vivo imaging experiments were performed in mice. The deep learning-based pansharpening algorithm achieved a root mean square error (RMSE) of 2.15±0.64, a correlation coefficient (CC) of 0.96±0.05, a spectral angle score of 0.06±0.03 radians, and an error relative global dimensionless synthesis (ERGAS) score of 2.37±1.71. Oxygen saturation (sO2) and lumen diameters of blood vessels were measured in the retina. The average lumen diameter of the venules was 45.7±13.6 μm, whereas the average lumen diameter of the arterioles was 31.5±8.7 μm. The average arteriole sO2 was 98%, whereas the average venule sO2 was 58%.ConclusionsA high-resolution hyperspectral imaging system was developed and validated for retina imaging and measurement of blood vessels and oxygen saturation.
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-19
Open AccessDevelopment and validation of a high-resolution hyperspectral imaging system for the retina
SignificanceEarly detection of Alzheimer’s diseases, diabetic retinopathy, or macular degeneration with advanced retinal imaging technologies can help improve patient care and treatment outcome.AimWe aim to create a high-resolution hyperspectral imaging (HSI) system for the retina. Retinal vessel diameter and oxygenation rate will be extracted simultaneously from HSI data.ApproachOur hyperspectral retinal imaging system consists of a snapshot hyperspectral camera, a high-resolution RGB camera, a beamsplitter, and an imaging endoscope. Multiple pansharpening algorithms, including deep learning methods, were developed to generate high-resolution hyperspectral images that were further used for the measurement of vessel size and oxygenation rate in mice.ResultsThe hyperspectral retinal imaging system was tested for its spatial resolution and spectral fidelity in retina phantoms. In vivo imaging experiments were performed in mice. The deep learning-based pansharpening algorithm achieved a root mean square error (RMSE) of 2.15±0.64, a correlation coefficient (CC) of 0.96±0.05, a spectral angle score of 0.06±0.03 radians, and an error relative global dimensionless synthesis (ERGAS) score of 2.37±1.71. Oxygen saturation (sO2) and lumen diameters of blood vessels were measured in the retina. The average lumen diameter of the venules was 45.7±13.6 μm, whereas the average lumen diameter of the arterioles was 31.5±8.7 μm. The average arteriole sO2 was 98%, whereas the average venule sO2 was 58%.ConclusionsA high-resolution hyperspectral imaging system was developed and validated for retina imaging and measurement of blood vessels and oxygen saturation.
- 7 April 2025
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 13408, 73-512
Retina phantom model for hyperspectral imaging
Accurate retinal imaging is crucial for preclinical research and the development of diagnostic and therapeutic approaches for eye diseases. However, existing retinal imaging models often lack the precision needed to replicate the complex optical environment of the eye, limiting their effectiveness in testing and calibration. Current approaches rely heavily on live animals, which pose ethical concerns and variability in results. In this work, we designed a retinal phantom that can be used to validate spatial and spectral properties. We developed a 3D-printed mouse phantom retina to simulate the conditions of the eye and mimic its optical qualities. We produced gelatin phantom with deoxygenated blood to simulate veins and arteries. Imaging was performed using a topical endoscopic fundus imaging (TEFI) hyperspectral camera. For data analysis, we estimated the oxygenation rate in the phantom. The results showed that the phantom had rich both spatial and spectral details. Oxygenation mapping shows that the phantom produced reliable oxygenation rates of the blood. We believed that this work can be used by researchers for the purpose of validating HSI cameras and may be iterated upon to simulate eye diseases.
- 7 April 2025
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 13408, 73-512
Retina phantom model for hyperspectral imaging
Accurate retinal imaging is crucial for preclinical research and the development of diagnostic and therapeutic approaches for eye diseases. However, existing retinal imaging models often lack the precision needed to replicate the complex optical environment of the eye, limiting their effectiveness in testing and calibration. Current approaches rely heavily on live animals, which pose ethical concerns and variability in results. In this work, we designed a retinal phantom that can be used to validate spatial and spectral properties. We developed a 3D-printed mouse phantom retina to simulate the conditions of the eye and mimic its optical qualities. We produced gelatin phantom with deoxygenated blood to simulate veins and arteries. Imaging was performed using a topical endoscopic fundus imaging (TEFI) hyperspectral camera. For data analysis, we estimated the oxygenation rate in the phantom. The results showed that the phantom had rich both spatial and spectral details. Oxygenation mapping shows that the phantom produced reliable oxygenation rates of the blood. We believed that this work can be used by researchers for the purpose of validating HSI cameras and may be iterated upon to simulate eye diseases.
- 2 April 2025
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 13410
A dual-camera high-resolution hyperspectral imaging system for the retina
Hyperspectral Imaging (HSI) emerged as a powerful tool for biomedical applications, particularly in the analysis and discrimination of biological tissues. In this study, we developed a dual-camera system that integrates hyperspectral imaging with high-resolution RGB imaging to capture detailed retinal images. We tested different pan-sharpening algorithms to enhance the spatial resolution of the hyperspectral images, combining the spectral details of HSI with the spatial details of RGB imaging. We developed algorithms to estimate the diameter of retinal vessels and the oxygenation rate. We validated our algorithms by imaging a mouse retinal phantom and then by imaging mice under anesthesia. Our systems showed the ability to resolve fine structural details, including small blood vessels. We found that out of the tested methods, PSGAN offered the best pansharpened image both quantitatively and qualitatively, with a Root-Mean-Squared Error (RMSE) score of 2.15 × 10-2. Using the pansharpened hyperspectral image, we measured vessels diameter and vessel oxygenation rate. We found the average diameter for arterioles and venules to be 45.7 μm and 31.5 μm, respectively. The average oxygenation rate for arterioles and venules were 96.2% and 76.3% respectively. This study represents a significant step towards the development of a versatile retinal imaging tool, with potential applications in both research and clinical diagnostics. Future work will focus on in vivo testing, algorithm refinement, and the exploration of specific retinal disease markers using this imaging system.
- 2 April 2025
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 13410
A dual-camera high-resolution hyperspectral imaging system for the retina
Hyperspectral Imaging (HSI) emerged as a powerful tool for biomedical applications, particularly in the analysis and discrimination of biological tissues. In this study, we developed a dual-camera system that integrates hyperspectral imaging with high-resolution RGB imaging to capture detailed retinal images. We tested different pan-sharpening algorithms to enhance the spatial resolution of the hyperspectral images, combining the spectral details of HSI with the spatial details of RGB imaging. We developed algorithms to estimate the diameter of retinal vessels and the oxygenation rate. We validated our algorithms by imaging a mouse retinal phantom and then by imaging mice under anesthesia. Our systems showed the ability to resolve fine structural details, including small blood vessels. We found that out of the tested methods, PSGAN offered the best pansharpened image both quantitatively and qualitatively, with a Root-Mean-Squared Error (RMSE) score of 2.15 × 10-2. Using the pansharpened hyperspectral image, we measured vessels diameter and vessel oxygenation rate. We found the average diameter for arterioles and venules to be 45.7 μm and 31.5 μm, respectively. The average oxygenation rate for arterioles and venules were 96.2% and 76.3% respectively. This study represents a significant step towards the development of a versatile retinal imaging tool, with potential applications in both research and clinical diagnostics. Future work will focus on in vivo testing, algorithm refinement, and the exploration of specific retinal disease markers using this imaging system.
- Open Access
- 24 July 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (09) , 093505-16
Detection and margin assessment of thyroid carcinoma with microscopic hyperspectral imaging using transformer networks
Thyroid cancer is one of the fastest-growing types of cancer in the United States with an estimated 43,720 new cases registered in 2023 alone.1 Even though a vast majority (more than 90%) of thyroid nodules are benign, some patients would develop malignant tumors that can migrate to other organs.2 The most common types of thyroid cancer originate from follicular epithelial cells. This includes papillary thyroid cancer (80% to 85% of cases3), follicular thyroid cancer, and anaplastic thyroid cancer.2 Medullary thyroid cancer, which accounts for only 1% to 2% of all thyroid cancer cases, originates from the parafollicular C cells.2 Thyroid lobectomy is a common treatment option if immediate risk is detected. During surgery, a pathologist determines the border between benign and cancerous tissue on a frozen section and helps identify the positive margin under a microscope. If cancer remains present at the edge of the tissue, the margin is labeled as positive, suggesting that the tumor was not entirely resected. The acceptable margin for thyroid carcinoma ranges from 5 to 20 mm.4 However, the thyroid region is vital for the quality of life; thus, it is also important to preserve as many non-tumor cells as possible. A balance is needed between a good negative margin and a good living outcome, and correct determination of the margin helps.
- 24 July 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (09) , 093505-16
Open AccessDetection and margin assessment of thyroid carcinoma with microscopic hyperspectral imaging using transformer networks
Thyroid cancer is one of the fastest-growing types of cancer in the United States with an estimated 43,720 new cases registered in 2023 alone.1 Even though a vast majority (more than 90%) of thyroid nodules are benign, some patients would develop malignant tumors that can migrate to other organs.2 The most common types of thyroid cancer originate from follicular epithelial cells. This includes papillary thyroid cancer (80% to 85% of cases3), follicular thyroid cancer, and anaplastic thyroid cancer.2 Medullary thyroid cancer, which accounts for only 1% to 2% of all thyroid cancer cases, originates from the parafollicular C cells.2 Thyroid lobectomy is a common treatment option if immediate risk is detected. During surgery, a pathologist determines the border between benign and cancerous tissue on a frozen section and helps identify the positive margin under a microscope. If cancer remains present at the edge of the tissue, the margin is labeled as positive, suggesting that the tumor was not entirely resected. The acceptable margin for thyroid carcinoma ranges from 5 to 20 mm.4 However, the thyroid region is vital for the quality of life; thus, it is also important to preserve as many non-tumor cells as possible. A balance is needed between a good negative margin and a good living outcome, and correct determination of the margin helps.
- Open Access
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (04) , 040901-50
Compact and ultracompact spectral imagers: technology and applications in biomedical imaging
Light interacts with objects through various means of scattering, absorption, reflection, and transmission. In the late 18th to early 19th century, studies involving light emitted from chemical flames and celestial bodies demonstrated that each chemical compound has a different fingerprint in its interactions with electromagnetic radiation. Nowadays, using instruments called spectrometers or spectrographs, the incoming radiation can be separated by wavelengths, and the resulting spectrum can be matched to determine the types and amount of chemicals. If spectrometers typically analyze the compound within a limited field of view, spectral imaging expands the field of view to include the spatial morphology of the subject. Spectral imaging is more powerful than spectrometry in understanding not just the types and amount but also the spatial distribution of chemicals.1 As such, spectral imaging is used in almost every application that requires imaging, such as satellite,2 agriculture,3 food science,4 and art.5 In biomedical imaging, spectral imaging has some advantages over regular color images. The amount of spectral and morphology information provides better understanding about physiological processes, which RGB and spectroscopy alone cannot achieve.6 Both Li et al.6 and Lu and Fei7 produced seminal literature reviews that discuss the different processes spectral imaging can reveal and help measure, such as metabolic processes; retinal oxygen saturation; tumors on the surface of skin, tongue, and mucosa; and ischemia in the intestine and the brain. Because spectral imaging mostly captures the reflected and scattered light in the nonionizing wavelengths, invasiveness and potential harm are minimal.
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (04) , 040901-50
Open AccessCompact and ultracompact spectral imagers: technology and applications in biomedical imaging
Light interacts with objects through various means of scattering, absorption, reflection, and transmission. In the late 18th to early 19th century, studies involving light emitted from chemical flames and celestial bodies demonstrated that each chemical compound has a different fingerprint in its interactions with electromagnetic radiation. Nowadays, using instruments called spectrometers or spectrographs, the incoming radiation can be separated by wavelengths, and the resulting spectrum can be matched to determine the types and amount of chemicals. If spectrometers typically analyze the compound within a limited field of view, spectral imaging expands the field of view to include the spatial morphology of the subject. Spectral imaging is more powerful than spectrometry in understanding not just the types and amount but also the spatial distribution of chemicals.1 As such, spectral imaging is used in almost every application that requires imaging, such as satellite,2 agriculture,3 food science,4 and art.5 In biomedical imaging, spectral imaging has some advantages over regular color images. The amount of spectral and morphology information provides better understanding about physiological processes, which RGB and spectroscopy alone cannot achieve.6 Both Li et al.6 and Lu and Fei7 produced seminal literature reviews that discuss the different processes spectral imaging can reveal and help measure, such as metabolic processes; retinal oxygen saturation; tumors on the surface of skin, tongue, and mucosa; and ischemia in the intestine and the brain. Because spectral imaging mostly captures the reflected and scattered light in the nonionizing wavelengths, invasiveness and potential harm are minimal.
- Open Access
- 23 May 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (05) , 059801-2
Unsupervised super-resolution reconstruction of hyperspectral histology images for whole-slide imaging (Errata)
Corrections to the published article include values in Table 1 and provision of an omitted reference.
- 23 May 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (05) , 059801-2
Open AccessUnsupervised super-resolution reconstruction of hyperspectral histology images for whole-slide imaging (Errata)
Corrections to the published article include values in Table 1 and provision of an omitted reference.
- Open Access
- 16 May 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (05) , 056502-21
Unsupervised super-resolution reconstruction of hyperspectral histology images for whole-slide imaging
Significance: Hyperspectral imaging (HSI) provides rich spectral information for improved histopathological cancer detection. However, acquiring high-resolution HSI data for whole-slide imaging (WSI) can be time-consuming and requires a huge amount of storage space. Aim: WSI using a color camera can be achieved with fast speed, high image resolution, and excellent image quality due to the established techniques. We aim to develop an RGB-guided unsupervised hyperspectral super-resolution reconstruction method that is hypothesized to improve image quality while maintaining the spectral characteristics. Approach: High-resolution hyperspectral images of 32 histologic slides were obtained via automated WSI. High-resolution RGB histology images were registered to the hyperspectral images for RGB guidance. An unsupervised super-resolution network was trained to take the downsampled low-resolution hyperspectral patches (LR-HSI) and high-resolution RGB patches (HR-RGB) as inputs to reconstruct high-resolution hyperspectral patches (HR-HSI). Then, an Inception-based network was trained with the HR-RGB, original HR-HSI, and generated HR-HSI, respectively, for whole-slide histopathological cancer detection. Results: Our super-resolution reconstruction network generated high-resolution hyperspectral images with well-maintained spectral characteristics and improved image quality. Image classification using the original hyperspectral data outperformed RGB because of the extra spectral information. The generated hyperspectral image patches further improved the results. Conclusions: The proposed method potentially reduces image acquisition time, saves storage space without compromising image quality, and improves the image classification performance.
- 16 May 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (05) , 056502-21
Open AccessUnsupervised super-resolution reconstruction of hyperspectral histology images for whole-slide imaging
Significance: Hyperspectral imaging (HSI) provides rich spectral information for improved histopathological cancer detection. However, acquiring high-resolution HSI data for whole-slide imaging (WSI) can be time-consuming and requires a huge amount of storage space. Aim: WSI using a color camera can be achieved with fast speed, high image resolution, and excellent image quality due to the established techniques. We aim to develop an RGB-guided unsupervised hyperspectral super-resolution reconstruction method that is hypothesized to improve image quality while maintaining the spectral characteristics. Approach: High-resolution hyperspectral images of 32 histologic slides were obtained via automated WSI. High-resolution RGB histology images were registered to the hyperspectral images for RGB guidance. An unsupervised super-resolution network was trained to take the downsampled low-resolution hyperspectral patches (LR-HSI) and high-resolution RGB patches (HR-RGB) as inputs to reconstruct high-resolution hyperspectral patches (HR-HSI). Then, an Inception-based network was trained with the HR-RGB, original HR-HSI, and generated HR-HSI, respectively, for whole-slide histopathological cancer detection. Results: Our super-resolution reconstruction network generated high-resolution hyperspectral images with well-maintained spectral characteristics and improved image quality. Image classification using the original hyperspectral data outperformed RGB because of the extra spectral information. The generated hyperspectral image patches further improved the results. Conclusions: The proposed method potentially reduces image acquisition time, saves storage space without compromising image quality, and improves the image classification performance.