Toru Noda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Toru Noda has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Naoyuki Maeda
Department of Ophthalmology (S.G., K.M.), The University of Osaka Graduate School of Medicine, Suita, Osaka, Japan
3 shared publications - So Goto
Department of Ophthalmology, Graduate School of Medicine, The University of Osaka, Suita, Osaka, Japan
3 shared publications - Kazuhiko Ohnuma
SEED CO., Ltd., 2-40-2 Hongo, Bunkyo-ku, Tokyo 113-8402, Japan
2 shared publications - Tjundewo Lawu
Design and Consult, VO, Toda, Japan
2 shared publications Hiroyuki Arai
Queen’s Eye Clinic, Kanagawa, Japan
1 shared publication- Kaoru Fujinami
Laboratory of Visual Physiology, Division of Vision Research, National Institute of Sensory Organs, National Hospital Organization Tokyo Medical Center, Tokyo, Japan
1 shared publication
Latest Publications
- 1 May 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (5) , 492-497
Impact of segmented optical axial length on the performance of intraocular lens power calculation formulas
Purpose: To investigate the difference between the segmented axial length (AL) and the composite AL on a swept-source optical coherence tomography biometer and to evaluate the subsequent effects on artificial intelligence intraocular lens (IOL) power calculations: the Kane and Hill-RBF 3.0 formulas compared with established vergence formulas. Setting: National Hospital Organization, Tokyo Medical Center, Japan. Design: Retrospective case series. Methods: Consecutive patients undergoing cataract surgery with a single-piece IOL were reviewed. The prediction accuracy of the Barrett Universal II, Haigis, Hill-RBF 3.0, Hoffer Q, Holladay 1, Kane, and SRK/T formulas based on 2 ALs were compared for each formula. The heteroscedastic test was used with the SD of prediction errors as the endpoint for formula performance. Results: The study included 145 eyes of 145 patients. The segmented AL (24.83 ± 1.89) was significantly shorter than the composite AL (24.88 ± 1.96, P < .001). Bland-Altman analysis revealed a negative proportional bias for the differences between the segmented AL and the composite AL. The SD values obtained by Hoffer Q, Holladay 1, and SRK/T formulas based on the segmented AL (0.52 diopters [D], 0.54 D, and 0.50 D, respectively) were significantly lower than those based on the composite AL (0.57 D, 0.60 D, and 0.52 D, respectively, P < .01). Conclusions: The segmented ALs were longer in short eyes and shorter in long eyes than the composite ALs. The refractive accuracy can be improved in the Hoffer Q, Holladay 1, and SRK/T formulas by changing the composite ALs to the segmented ALs.
- 1 May 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (5) , 492-497
Impact of segmented optical axial length on the performance of intraocular lens power calculation formulas
Purpose: To investigate the difference between the segmented axial length (AL) and the composite AL on a swept-source optical coherence tomography biometer and to evaluate the subsequent effects on artificial intelligence intraocular lens (IOL) power calculations: the Kane and Hill-RBF 3.0 formulas compared with established vergence formulas. Setting: National Hospital Organization, Tokyo Medical Center, Japan. Design: Retrospective case series. Methods: Consecutive patients undergoing cataract surgery with a single-piece IOL were reviewed. The prediction accuracy of the Barrett Universal II, Haigis, Hill-RBF 3.0, Hoffer Q, Holladay 1, Kane, and SRK/T formulas based on 2 ALs were compared for each formula. The heteroscedastic test was used with the SD of prediction errors as the endpoint for formula performance. Results: The study included 145 eyes of 145 patients. The segmented AL (24.83 ± 1.89) was significantly shorter than the composite AL (24.88 ± 1.96, P < .001). Bland-Altman analysis revealed a negative proportional bias for the differences between the segmented AL and the composite AL. The SD values obtained by Hoffer Q, Holladay 1, and SRK/T formulas based on the segmented AL (0.52 diopters [D], 0.54 D, and 0.50 D, respectively) were significantly lower than those based on the composite AL (0.57 D, 0.60 D, and 0.52 D, respectively, P < .01). Conclusions: The segmented ALs were longer in short eyes and shorter in long eyes than the composite ALs. The refractive accuracy can be improved in the Hoffer Q, Holladay 1, and SRK/T formulas by changing the composite ALs to the segmented ALs.
- Open Access
- 7 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 6959
Effect of Segmented Optical Axial Length on the Performance of New-Generation Intraocular Lens Power Calculation Formulas in Extremely Long Eyes
Purpose: To evaluate the performance of traditional vergence formulas with segmented axial length (AL) compared to traditional composite AL in extremely long eyes, and to determine whether the segmented AL can be extended to the new-generation formulas, including the Barrett Universal II, Emmetropia Verifying Optical 2.0 (EVO2), Hill-RBF 3.0 (Hill3), Kane, and Ladas Super formula (LSF) formulas in extremely long eyes. Setting: National Hospital. Organization, Tokyo Medical Center, Japan. Design: Retrospective case series. Methods: Consecutive patients who underwent uncomplicated cataract surgery implanted with a three-piece intraocular lens between December 2015 and March 2021 were retrospectively reviewed. The composite AL was measured with a swept-source optical coherence tomography (SS-OCT) biometer using a mean refractive index. The segmented AL was calculated by summing the geometric lengths of the ocular segments (cornea, aqueous, lens, and vitreous) using multiple specific refractive indices based on the data obtained by the SS-OCT-based biometer. When refraction was measured at three months postoperatively, the median absolute errors (MedAEs) were calculated with two ALs for each formula. Results: The study included 31 eyes of 22 patients. The segmented AL (30.45 ± 1.23 mm) was significantly shorter than the composite AL (30.71 ± 1.28 mm, p < 0.001). The MedAEs were significantly reduced when using segmented AL for SRK/T, Haigis, Hill3, and LSF, compared to those obtained using composite AL (0.38 vs. 0.62, 0.48 vs. 0.79, 0.50 vs. 0.90, 0.34 vs. 0.61, p < 0.001 for all formulas, respectively). On the contrary, the MedAE obtained by Kane with segmented AL was significantly worse compared to the one with composite AL (0.35 vs. 0.27, p = 0.03). Conclusion: In extremely high myopic eyes, the segmented AL improves the performance of SRK/T, Haigis, Hill3, and LSF formulas compared to the composite AL, while the segmented AL worsens the prediction accuracy of the Kane formula.
- 7 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 6959
Open AccessEffect of Segmented Optical Axial Length on the Performance of New-Generation Intraocular Lens Power Calculation Formulas in Extremely Long Eyes
Purpose: To evaluate the performance of traditional vergence formulas with segmented axial length (AL) compared to traditional composite AL in extremely long eyes, and to determine whether the segmented AL can be extended to the new-generation formulas, including the Barrett Universal II, Emmetropia Verifying Optical 2.0 (EVO2), Hill-RBF 3.0 (Hill3), Kane, and Ladas Super formula (LSF) formulas in extremely long eyes. Setting: National Hospital. Organization, Tokyo Medical Center, Japan. Design: Retrospective case series. Methods: Consecutive patients who underwent uncomplicated cataract surgery implanted with a three-piece intraocular lens between December 2015 and March 2021 were retrospectively reviewed. The composite AL was measured with a swept-source optical coherence tomography (SS-OCT) biometer using a mean refractive index. The segmented AL was calculated by summing the geometric lengths of the ocular segments (cornea, aqueous, lens, and vitreous) using multiple specific refractive indices based on the data obtained by the SS-OCT-based biometer. When refraction was measured at three months postoperatively, the median absolute errors (MedAEs) were calculated with two ALs for each formula. Results: The study included 31 eyes of 22 patients. The segmented AL (30.45 ± 1.23 mm) was significantly shorter than the composite AL (30.71 ± 1.28 mm, p < 0.001). The MedAEs were significantly reduced when using segmented AL for SRK/T, Haigis, Hill3, and LSF, compared to those obtained using composite AL (0.38 vs. 0.62, 0.48 vs. 0.79, 0.50 vs. 0.90, 0.34 vs. 0.61, p < 0.001 for all formulas, respectively). On the contrary, the MedAE obtained by Kane with segmented AL was significantly worse compared to the one with composite AL (0.35 vs. 0.27, p = 0.03). Conclusion: In extremely high myopic eyes, the segmented AL improves the performance of SRK/T, Haigis, Hill3, and LSF formulas compared to the composite AL, while the segmented AL worsens the prediction accuracy of the Kane formula.
- Open Access
- 1 June 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (11) , 1305-1311
Preliminary demonstration of a novel intraocular lens power calculation: the O formula
Purpose: To evaluate the performance of a new formula of intraocular lens (IOL) power calculation (the O formula) based on ray tracing without commonly used parameters, including ultrasound-compatible axial length, keratometry readings, and A-constant. Setting: Tokyo Medical Center, Tokyo, Japan. Design: Retrospective consecutive case series. Methods: 423 eyes (423 patients) implanted with a single-piece, L-loop, acrylic IOL were enrolled. All biometric data for the O formula were obtained by anterior segment swept-source optical coherence tomography (SS-OCT) and SS-OCT–based biometer. The performance of the O formula was compared with those of the Barrett Universal II (BUII) and Kane formulas at 1 month postoperatively. Statistical analysis was applied according to a heteroscedastic test with SD of prediction errors as the main parameter for formula performance. Results: The SD of the O formula (0.426) was statistically significantly lower than that of the BUII formula (0.464, P = .034) but not statistically significantly different from that of the Kane formula (0.433, P = .601). The percentages of patients with refractive prediction errors within ±0.50 diopter (D) and ±1.00 D of the O, BUII, and Kane formulas were 75.4% and 98.6%, 77.1% and 97.9%, and 76.6% and 98.1%, respectively. Conclusions: The O formula, based on ray tracing using SS-OCT–based devices, is one of the promising approaches for IOL power calculation, although additional larger scale studies are needed. It may be used as an alternative in IOL power calculation because of its independence from commonly used parameters.
- 1 June 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (11) , 1305-1311
Open AccessPreliminary demonstration of a novel intraocular lens power calculation: the O formula
Purpose: To evaluate the performance of a new formula of intraocular lens (IOL) power calculation (the O formula) based on ray tracing without commonly used parameters, including ultrasound-compatible axial length, keratometry readings, and A-constant. Setting: Tokyo Medical Center, Tokyo, Japan. Design: Retrospective consecutive case series. Methods: 423 eyes (423 patients) implanted with a single-piece, L-loop, acrylic IOL were enrolled. All biometric data for the O formula were obtained by anterior segment swept-source optical coherence tomography (SS-OCT) and SS-OCT–based biometer. The performance of the O formula was compared with those of the Barrett Universal II (BUII) and Kane formulas at 1 month postoperatively. Statistical analysis was applied according to a heteroscedastic test with SD of prediction errors as the main parameter for formula performance. Results: The SD of the O formula (0.426) was statistically significantly lower than that of the BUII formula (0.464, P = .034) but not statistically significantly different from that of the Kane formula (0.433, P = .601). The percentages of patients with refractive prediction errors within ±0.50 diopter (D) and ±1.00 D of the O, BUII, and Kane formulas were 75.4% and 98.6%, 77.1% and 97.9%, and 76.6% and 98.1%, respectively. Conclusions: The O formula, based on ray tracing using SS-OCT–based devices, is one of the promising approaches for IOL power calculation, although additional larger scale studies are needed. It may be used as an alternative in IOL power calculation because of its independence from commonly used parameters.
- Open Access
- 30 December 2020
- Published by Wolters Kluwer Health in Retina
- Vol. 41 (8) , 1618-1626
RETINAL SURFACE WRINKLING AS AN INDICATOR FOR INTERNAL LIMITING MEMBRANE PEELING DURING VITRECTOMY FOR RETINAL DETACHMENT
Purpose: To assess the validity of retinal surface wrinkling (RSW) as an indicator to select patients relevant for internal limiting membrane peeling during vitrectomy for rhegmatogenous retinal detachment, to prevent postoperative visual decline due to epiretinal membrane growth. Methods: This was a prospective, interventional case series of 78 consecutive eyes that underwent initial vitrectomy to repair rhegmatogenous retinal detachments and were followed for 6 months. The presence/absence of RSW was evaluated presurgically on en face optical coherence tomographic images. The internal limiting membrane was peeled if RSW was identified. The main outcome measure was the prevalence of postsurgical epiretinal membrane growth that caused a visual decline of 0.2 or more in logarithm of the minimum angle of resolution unit. Results: The internal limiting membrane was peeled for RSW appearance in 22 eyes (28.2%). Mild epiretinal membranes developed in 8 of the 56 internal limiting membrane–unpeeled eyes (10.3% of total, 6 eyes at stage 1 in the classification of Govetto); however, visual decline occurred in none of them with the mean visual acuity of these 8 eyes maintained at −0.08 ± 0.11 in logarithm of the minimum angle of resolution (≈20/16). Conclusion: Visual decline due to epiretinal membrane growth after rhegmatogenous retinal detachment repair was entirely prevented by peeling the internal limiting membrane in about 30% of cases selected for the presence of RSW.
- 30 December 2020
- Published by Wolters Kluwer Health in Retina
- Vol. 41 (8) , 1618-1626
Open AccessRETINAL SURFACE WRINKLING AS AN INDICATOR FOR INTERNAL LIMITING MEMBRANE PEELING DURING VITRECTOMY FOR RETINAL DETACHMENT
Purpose: To assess the validity of retinal surface wrinkling (RSW) as an indicator to select patients relevant for internal limiting membrane peeling during vitrectomy for rhegmatogenous retinal detachment, to prevent postoperative visual decline due to epiretinal membrane growth. Methods: This was a prospective, interventional case series of 78 consecutive eyes that underwent initial vitrectomy to repair rhegmatogenous retinal detachments and were followed for 6 months. The presence/absence of RSW was evaluated presurgically on en face optical coherence tomographic images. The internal limiting membrane was peeled if RSW was identified. The main outcome measure was the prevalence of postsurgical epiretinal membrane growth that caused a visual decline of 0.2 or more in logarithm of the minimum angle of resolution unit. Results: The internal limiting membrane was peeled for RSW appearance in 22 eyes (28.2%). Mild epiretinal membranes developed in 8 of the 56 internal limiting membrane–unpeeled eyes (10.3% of total, 6 eyes at stage 1 in the classification of Govetto); however, visual decline occurred in none of them with the mean visual acuity of these 8 eyes maintained at −0.08 ± 0.11 in logarithm of the minimum angle of resolution (≈20/16). Conclusion: Visual decline due to epiretinal membrane growth after rhegmatogenous retinal detachment repair was entirely prevented by peeling the internal limiting membrane in about 30% of cases selected for the presence of RSW.
- Open Access
- 11 September 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition
We conducted a one-year prospective, multicenter study to assess clinical outcomes after implantation of segmented, rotationally asymmetric multifocal intraocular lenses (IOLs) with +1.5 diopters (D) near addition. In this phase III clinical trial, 120 eyes of 65 patients undergoing phacoemulsification and implantation of Lentis Comfort LS-313 MF15 (Oculentis GmbH) were included. The ophthalmological examinations were performed before and 1 day, 1 week, 1, 3, 6, 9, and 12 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were measured. A defocus curve was obtained and patients were asked about the severity of photic phenomena. Postoperative distance and intermediate visual acuity was excellent, with UDVA, CDVA, UIVA, and DCIVA of approximately 20/20, 20/16, 20/25, 20/25 were attained, respectively. The level of near visual acuity was lower; UNVA and DCNVA remained at around 20/60 and 20/70, respectively. The defocus curve indicated that postoperative uncorrected visual acuity of 20/25 and 20/40 was obtained at as close as 67 cm and 50 cm, respectively. Contrast sensitivity was within the normal range, with a minimal level of subjective symptoms and high patient satisfaction. The rotationally asymmetric multifocal IOLs with +1.5 D near addition provided excellent distance and intermediate vision, but near vision was not enough for reading small prints. Contrast sensitivity was high, with very low incidences of photic phenomena and a high level of patient satisfaction.
- 11 September 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
Open AccessOne-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition
We conducted a one-year prospective, multicenter study to assess clinical outcomes after implantation of segmented, rotationally asymmetric multifocal intraocular lenses (IOLs) with +1.5 diopters (D) near addition. In this phase III clinical trial, 120 eyes of 65 patients undergoing phacoemulsification and implantation of Lentis Comfort LS-313 MF15 (Oculentis GmbH) were included. The ophthalmological examinations were performed before and 1 day, 1 week, 1, 3, 6, 9, and 12 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were measured. A defocus curve was obtained and patients were asked about the severity of photic phenomena. Postoperative distance and intermediate visual acuity was excellent, with UDVA, CDVA, UIVA, and DCIVA of approximately 20/20, 20/16, 20/25, 20/25 were attained, respectively. The level of near visual acuity was lower; UNVA and DCNVA remained at around 20/60 and 20/70, respectively. The defocus curve indicated that postoperative uncorrected visual acuity of 20/25 and 20/40 was obtained at as close as 67 cm and 50 cm, respectively. Contrast sensitivity was within the normal range, with a minimal level of subjective symptoms and high patient satisfaction. The rotationally asymmetric multifocal IOLs with +1.5 D near addition provided excellent distance and intermediate vision, but near vision was not enough for reading small prints. Contrast sensitivity was high, with very low incidences of photic phenomena and a high level of patient satisfaction.