Jason L. Kost
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jason L. Kost has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alain R. Berdoz
Naval Research Laboratory, Code 7130, Washington, DC 20375
1 shared publication - Brian H. Houston
Physical Acoustics Branch (Code 7130), Naval Research Laboratory, Washington, USA
1 shared publication - Daniel L. Amon
Naval Research Laboratory, Code 7130, Washington, DC 20375
1 shared publication - Harry J. Simpson
Naval Res. Lab., Code 7130, 4555 Overlook Ave., Washington, DC 20375-5320
1 shared publication - Kevin Co
Laboratoire Structures, Propriétés et Modélisation des Solides, CentraleSupélec, Université Paris-Saclay, 91190 Gif-sur-Yvette, France
1 shared publication - Konrad Bussmann
US Naval Research Laboratory 2 , Washington, DC 02375, USA
1 shared publication
Latest Publications
- Open Access
High Isolation, Double-Clamped, Magnetoelectric Microelectromechanical Resonator Magnetometer
Magnetoelectric (ME)-based magnetometers have garnered much attention as they boast ultra-low-power systems with a small form factor and limit of detection in the tens of picotesla. The highly sensitive and low-power electric readout from the ME sensor makes them attractive for near DC and low-frequency AC magnetic fields as platforms for continuous magnetic signature monitoring. Among multiple configurations of the current ME magnetic sensors, most rely on exploiting the mechanically resonant characteristics of a released ME microelectromechanical system (MEMS) in a heterostructure device. Through optimizing the resonant device configuration, we design and fabricate a fixed–fixed resonant beam structure with high isolation compared to previous designs operating at ~800 nW of power comprised of piezoelectric aluminum nitride (AlN) and magnetostrictive (Co1-xFex)-based thin films that are less susceptible to vibration while providing similar characteristics to ME-MEMS cantilever devices. In this new design of double-clamped magnetoelectric MEMS resonators, we have also utilized thin films of a new iron–cobalt–hafnium alloy (Fe0.5Co0.5)0.92Hf0.08 that provides a low-stress, high magnetostrictive material with an amorphous crystalline structure and ultra-low magnetocrystalline anisotropy. Together, the improvements of this sensor design yield a magnetic field sensitivity of 125 Hz/mT when released in a compressive state. The overall detection limit of these sensors using an electric field drive and readout are presented, and noise sources are discussed. Based on these results, design parameters for future ME MEMS field sensors are discussed.
Open AccessHigh Isolation, Double-Clamped, Magnetoelectric Microelectromechanical Resonator Magnetometer
Magnetoelectric (ME)-based magnetometers have garnered much attention as they boast ultra-low-power systems with a small form factor and limit of detection in the tens of picotesla. The highly sensitive and low-power electric readout from the ME sensor makes them attractive for near DC and low-frequency AC magnetic fields as platforms for continuous magnetic signature monitoring. Among multiple configurations of the current ME magnetic sensors, most rely on exploiting the mechanically resonant characteristics of a released ME microelectromechanical system (MEMS) in a heterostructure device. Through optimizing the resonant device configuration, we design and fabricate a fixed–fixed resonant beam structure with high isolation compared to previous designs operating at ~800 nW of power comprised of piezoelectric aluminum nitride (AlN) and magnetostrictive (Co1-xFex)-based thin films that are less susceptible to vibration while providing similar characteristics to ME-MEMS cantilever devices. In this new design of double-clamped magnetoelectric MEMS resonators, we have also utilized thin films of a new iron–cobalt–hafnium alloy (Fe0.5Co0.5)0.92Hf0.08 that provides a low-stress, high magnetostrictive material with an amorphous crystalline structure and ultra-low magnetocrystalline anisotropy. Together, the improvements of this sensor design yield a magnetic field sensitivity of 125 Hz/mT when released in a compressive state. The overall detection limit of these sensors using an electric field drive and readout are presented, and noise sources are discussed. Based on these results, design parameters for future ME MEMS field sensors are discussed.
- Open Access
- 1 January 2019
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 145 (1) , EL90-EL96
Demonstration of a quasi-monostatic autonomous underwater vehicle based high duty cycle active sonar
The feasibility of resolving target returns within receive signals collected by a continuously transmitting quasi-monostatic, broadband, autonomous underwater vehicle (AUV) based sonar is explored. Theoretical studies supported by experimental results suggest that it is possible to capture the source-to-receiver coupling response and target scattering with sufficient fidelity during the continuous transmission to enable detection and (potentially) classification processing. Demonstrations focused upon the detection of a bottomed target object at sea using transmit signals with duty cycles of 60% and 100% indicate that such an approach is feasible for a representative AUV-based side looking sonar system operating in shallow water.
- 1 January 2019
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 145 (1) , EL90-EL96
Open AccessDemonstration of a quasi-monostatic autonomous underwater vehicle based high duty cycle active sonar
The feasibility of resolving target returns within receive signals collected by a continuously transmitting quasi-monostatic, broadband, autonomous underwater vehicle (AUV) based sonar is explored. Theoretical studies supported by experimental results suggest that it is possible to capture the source-to-receiver coupling response and target scattering with sufficient fidelity during the continuous transmission to enable detection and (potentially) classification processing. Demonstrations focused upon the detection of a bottomed target object at sea using transmit signals with duty cycles of 60% and 100% indicate that such an approach is feasible for a representative AUV-based side looking sonar system operating in shallow water.