Lei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lei Zhang has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
Jia Yang
Shanghai Jiao Tong Univ, Sch Med, Shanghai Gen Hosp, Dept Radiol, Shanghai, Peoples R China
3 shared publicationsQian Luo
Shanghai General Hospital of Shanghai Jiao Tong University School of Medicine
3 shared publications- Yi Zhang
Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
3 shared publications - Fang Liu
Department of Endocrinology and Metabolism, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 201620, China
2 shared publications - Xin-Xing Hu
Shanghai Jiao Tong Univ, Sch Med, Shanghai Gen Hosp, Dept Radiol, Shanghai, Peoples R China
2 shared publications - Yi Zhang
Shanghai General Hospital of Shanghai Jiao Tong University School of Medicine
2 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (2) , 164
Comprehensive cardiac magnetic resonance imaging in patients with idiopathic premature ventricular contractions: role of feature-tracking strain and T1/T2 mapping in detecting subclinical myocardial dysfunction
Original Article Comprehensive cardiac magnetic resonance imaging in patients with idiopathic premature ventricular contractions: role of feature-tracking strain and T1/T2 mapping in detecting subclinical myocardial dysfunction Jia Yang, Yi Zhang, Qinqin Yu, Xinxing Hu, Qian Luo, Lei Zhang
- 1 February 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (2) , 164
Open AccessComprehensive cardiac magnetic resonance imaging in patients with idiopathic premature ventricular contractions: role of feature-tracking strain and T1/T2 mapping in detecting subclinical myocardial dysfunction
Original Article Comprehensive cardiac magnetic resonance imaging in patients with idiopathic premature ventricular contractions: role of feature-tracking strain and T1/T2 mapping in detecting subclinical myocardial dysfunction Jia Yang, Yi Zhang, Qinqin Yu, Xinxing Hu, Qian Luo, Lei Zhang
- Open Access
- 25 November 2025
- Published by Springer Nature in Research Square
Early cardiac involvement in patients with hyperthyroidism identified by multiparametric cardiovascular magnetic resonance imaging
Background: Hyperthyroidism is reportedly associated with increased cardiovascular risk and heart failure. However, a definite association between hyperthyroidism and cardiomyopathy has not been reported. This study aimed to analyze alterations in myocardial tissue characteristics and strain, and to fill the knowledge gap about identifying early cardiac involvement in patients with hyperthyroidism. Methods: In this single center retrospective study, forty-one patients in the hyperthyroid state with a clinically indicated cardiac magnetic resonance (CMR) (and thus: 1≥ marker of cardiac involvement cardiac symptoms, electrocardiograph abnormalities or elevated cardiac biomarkers) and thirty-one healthy controls underwent CMR imaging. Results : The myocardial native T1 value was significantly higher in the hyperthyroidism group compared with the control group (1301.8 ± 38.5 vs. 1270.0 ± 19.6 ms; P<0.001). The left ventricular T2 value, global myocardial strain, myocardial mass, and ejection fraction (LVEF) was similar in hyperthyroidism and control patients. In the hyperthyroidism group, ECV fraction was significantly correlated with free triiodothyronine (FT3) levels (r=0.498, p=0.002) and total triiodothyronine (TT3) levels (r=0.408, p=0.012). Native T1 values>1284 ms could distinguish patients with hyperthyroidism from healthy controls, with a sensitivity of 78% and a specificity of 80.6%. Conclusions: Hyperthyroidism with normal myocardial strain exhibits increased native T1 value and ECV fraction, indicative of myocardial extracellular interstitial expansion, which is associated with serum triiodothyronine levels. T1 mapping may be an early marker of myocardial involvement in patients with hyperthyroidism.
- 25 November 2025
- Published by Springer Nature in Research Square
Open AccessEarly cardiac involvement in patients with hyperthyroidism identified by multiparametric cardiovascular magnetic resonance imaging
Background: Hyperthyroidism is reportedly associated with increased cardiovascular risk and heart failure. However, a definite association between hyperthyroidism and cardiomyopathy has not been reported. This study aimed to analyze alterations in myocardial tissue characteristics and strain, and to fill the knowledge gap about identifying early cardiac involvement in patients with hyperthyroidism. Methods: In this single center retrospective study, forty-one patients in the hyperthyroid state with a clinically indicated cardiac magnetic resonance (CMR) (and thus: 1≥ marker of cardiac involvement cardiac symptoms, electrocardiograph abnormalities or elevated cardiac biomarkers) and thirty-one healthy controls underwent CMR imaging. Results : The myocardial native T1 value was significantly higher in the hyperthyroidism group compared with the control group (1301.8 ± 38.5 vs. 1270.0 ± 19.6 ms; P<0.001). The left ventricular T2 value, global myocardial strain, myocardial mass, and ejection fraction (LVEF) was similar in hyperthyroidism and control patients. In the hyperthyroidism group, ECV fraction was significantly correlated with free triiodothyronine (FT3) levels (r=0.498, p=0.002) and total triiodothyronine (TT3) levels (r=0.408, p=0.012). Native T1 values>1284 ms could distinguish patients with hyperthyroidism from healthy controls, with a sensitivity of 78% and a specificity of 80.6%. Conclusions: Hyperthyroidism with normal myocardial strain exhibits increased native T1 value and ECV fraction, indicative of myocardial extracellular interstitial expansion, which is associated with serum triiodothyronine levels. T1 mapping may be an early marker of myocardial involvement in patients with hyperthyroidism.
- Open Access
- 2 June 2025
- Published by Frontiers Media SA in Frontiers in Endocrinology
- Vol. 16, 1566029
Early cardiac involvement in patients with hyperthyroidism evaluated by cardiac magnetic resonance feature tracking
Background: This study aimed to investigate the feasibility of quantitative assessment of myocardial injury in the early stages of the disease by myocardial strain in patients with hyperthyroidism.Methods and results: A total of 45 individuals in the hyperthyroid state with at least one index of cardiac involvement (e.g., cardiac symptoms, abnormal electrocardiogram, or abnormal cardiac biomarkers) and 26 healthy controls were subjected to cardiovascular magnetic resonance (CMR) to assess the left ventricular (LV) volumetry, LV mass index (LVMi), LV ejection fraction (LVEF), myocardial strain, and the total (TEF), passive (PEF), and active (AEF) left atrial (LA) emptying fractions. Patients with hyperthyroidism were classified into two categories according to the presence (n = 5) or absence (n = 40) of atrial fibrillation (AF). The LA reservoir, conduit, and booster strains were significantly impaired in all patients with hyperthyroidism (all p < 0.01). In contrast, the LA and LV ejection fractions, LVMi, and LV myocardial strain showed no significant differences between the cases without AF and the healthy controls (all p > 0.05). The LA-AEF and LVEF were significantly decreased in the hyperthyroidism cases with AF compared with the hyperthyroidism cases without AF, although no significant differences in the LA-TEF, PEF, and LVMi were detected. The receiver operating characteristic (ROC) curve analysis revealed superior diagnostic value for the LA reservoir strain, which distinguished hyperthyroidism cases from normal subjects with a sensitivity of 80.8% and a specificity of 80%.Conclusions: The LA strain reliably differentiates early cardiac involvement between patients with hyperthyroidism and healthy controls, whereas volumetric parameters and ventricular myocardial strain fail to do so.
- 2 June 2025
- Published by Frontiers Media SA in Frontiers in Endocrinology
- Vol. 16, 1566029
Open AccessEarly cardiac involvement in patients with hyperthyroidism evaluated by cardiac magnetic resonance feature tracking
Background: This study aimed to investigate the feasibility of quantitative assessment of myocardial injury in the early stages of the disease by myocardial strain in patients with hyperthyroidism.Methods and results: A total of 45 individuals in the hyperthyroid state with at least one index of cardiac involvement (e.g., cardiac symptoms, abnormal electrocardiogram, or abnormal cardiac biomarkers) and 26 healthy controls were subjected to cardiovascular magnetic resonance (CMR) to assess the left ventricular (LV) volumetry, LV mass index (LVMi), LV ejection fraction (LVEF), myocardial strain, and the total (TEF), passive (PEF), and active (AEF) left atrial (LA) emptying fractions. Patients with hyperthyroidism were classified into two categories according to the presence (n = 5) or absence (n = 40) of atrial fibrillation (AF). The LA reservoir, conduit, and booster strains were significantly impaired in all patients with hyperthyroidism (all p < 0.01). In contrast, the LA and LV ejection fractions, LVMi, and LV myocardial strain showed no significant differences between the cases without AF and the healthy controls (all p > 0.05). The LA-AEF and LVEF were significantly decreased in the hyperthyroidism cases with AF compared with the hyperthyroidism cases without AF, although no significant differences in the LA-TEF, PEF, and LVMi were detected. The receiver operating characteristic (ROC) curve analysis revealed superior diagnostic value for the LA reservoir strain, which distinguished hyperthyroidism cases from normal subjects with a sensitivity of 80.8% and a specificity of 80%.Conclusions: The LA strain reliably differentiates early cardiac involvement between patients with hyperthyroidism and healthy controls, whereas volumetric parameters and ventricular myocardial strain fail to do so.
- Open Access
- 1 March 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (3) , 2119-2131
Comparative analysis of U-Mamba and no new U-Net for the detection and segmentation of esophageal cancer in contrast-enhanced computed tomography images
Background: Radiomics research in esophageal cancer (EC) has made considerable advancements. However, manual segmentation, which is relied upon in clinical and scientific workflows, remains time-consuming and inconsistent. This study aimed to develop and validate a deep learning (DL) model for the automatic detection and segmentation of EC lesions in contrast-enhanced computed tomography (CT) images. Methods: We retrospectively collected the CT data of patients with EC confirmed by pathology from January 2017 to September 2021 at three hospitals and from individuals with a healthy esophagus. Manual labeling of EC lesions was conducted, and DL networks [no new U-Net (nnU-Net) and U-Mamba] were trained for automatic segmentation. An optimal threshold volume for EC lesion detection was determined and integrated into the postprocessing module. The performance of DL models was evaluated in internal, external, and thin-slice image test cohorts and compared with diagnoses by radiologists. The sensitivity, specificity, accuracy, Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated. Results: A total of 871 patients (564 males) were included, with a median age of 67 years. DL models exhibited no significant difference from radiologists’ diagnoses (P>0.05). Median DSC values for the internal, external, and thin-slice cohorts were 0.795, 0.811, and 0.797, respectively, with a corresponding HD of 9.733 mm, 7.860 mm, and 8.168 mm. An intraclass correlation coefficient greater than 0.7 was observed for 97.2% of the radiomic features extracted from thin-slice images. Conclusions: The DL methods demonstrated exceptional sensitivity and robustness in EC detection and segmentation on contrast-enhanced CT images, not only reducing missed EC diagnoses but also providing radiologists with consistent lesion annotations.
- 1 March 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (3) , 2119-2131
Open AccessComparative analysis of U-Mamba and no new U-Net for the detection and segmentation of esophageal cancer in contrast-enhanced computed tomography images
Background: Radiomics research in esophageal cancer (EC) has made considerable advancements. However, manual segmentation, which is relied upon in clinical and scientific workflows, remains time-consuming and inconsistent. This study aimed to develop and validate a deep learning (DL) model for the automatic detection and segmentation of EC lesions in contrast-enhanced computed tomography (CT) images. Methods: We retrospectively collected the CT data of patients with EC confirmed by pathology from January 2017 to September 2021 at three hospitals and from individuals with a healthy esophagus. Manual labeling of EC lesions was conducted, and DL networks [no new U-Net (nnU-Net) and U-Mamba] were trained for automatic segmentation. An optimal threshold volume for EC lesion detection was determined and integrated into the postprocessing module. The performance of DL models was evaluated in internal, external, and thin-slice image test cohorts and compared with diagnoses by radiologists. The sensitivity, specificity, accuracy, Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated. Results: A total of 871 patients (564 males) were included, with a median age of 67 years. DL models exhibited no significant difference from radiologists’ diagnoses (P>0.05). Median DSC values for the internal, external, and thin-slice cohorts were 0.795, 0.811, and 0.797, respectively, with a corresponding HD of 9.733 mm, 7.860 mm, and 8.168 mm. An intraclass correlation coefficient greater than 0.7 was observed for 97.2% of the radiomic features extracted from thin-slice images. Conclusions: The DL methods demonstrated exceptional sensitivity and robustness in EC detection and segmentation on contrast-enhanced CT images, not only reducing missed EC diagnoses but also providing radiologists with consistent lesion annotations.
- 12 October 2024
- Published by Wiley in Laser & Photonics Reviews
- Vol. 19 (8)
Highly Efficient Slow‐Light Mach–Zehnder Modulator Achieving 0.21 V cm Efficiency with Bandwidth Surpassing 110 GHz
High‐speed electro‐optic modulators are key components in modern communication networks and various applications that require chip‐scale modulation with large bandwidth, high modulation efficiency, and compact footprint. However, fundamental trade‐offs make it challenging to achieve these metrics simultaneously, and thus new methodologies must be explored. To this end, a Mach–Zehnder modulator harnessing slow‐light waveguides and capacitively loaded slow‐wave electrodes are presented on silicon‐nitride‐loaded lithium niobate on an insulator platform. The increased group index and reduced microwave loss significantly improve the modulation efficiency. With the 1‐mm‐length modulation section, a low half‐wave voltage length product Vπ·L of 0.21 V cm is obtained, which is one order of magnitude smaller than that of conventional thin film lithium niobate Mach–Zehnder modulators, and a modulation bandwidth of surpassing 110 GHz is achieved. The digital signal processor‐free non‐return‐to‐zero signal and eight‐level pulse amplitude modulation signal of up to 180 and 300 Gbps, respectively, are generated by the modulator, which provides ultra‐large bandwidth, ultra‐high efficiency, and a compact solution for next‐generation electro‐optic systems.
- 12 October 2024
- Published by Wiley in Laser & Photonics Reviews
- Vol. 19 (8)
Highly Efficient Slow‐Light Mach–Zehnder Modulator Achieving 0.21 V cm Efficiency with Bandwidth Surpassing 110 GHz
High‐speed electro‐optic modulators are key components in modern communication networks and various applications that require chip‐scale modulation with large bandwidth, high modulation efficiency, and compact footprint. However, fundamental trade‐offs make it challenging to achieve these metrics simultaneously, and thus new methodologies must be explored. To this end, a Mach–Zehnder modulator harnessing slow‐light waveguides and capacitively loaded slow‐wave electrodes are presented on silicon‐nitride‐loaded lithium niobate on an insulator platform. The increased group index and reduced microwave loss significantly improve the modulation efficiency. With the 1‐mm‐length modulation section, a low half‐wave voltage length product Vπ·L of 0.21 V cm is obtained, which is one order of magnitude smaller than that of conventional thin film lithium niobate Mach–Zehnder modulators, and a modulation bandwidth of surpassing 110 GHz is achieved. The digital signal processor‐free non‐return‐to‐zero signal and eight‐level pulse amplitude modulation signal of up to 180 and 300 Gbps, respectively, are generated by the modulator, which provides ultra‐large bandwidth, ultra‐high efficiency, and a compact solution for next‐generation electro‐optic systems.
- Open Access
- 1 November 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (6) , 741-752
A model incorporating clinicopathologic and liver imaging reporting and data system-based magnetic resonance imaging features to identify hepatocellular carcinoma in LR-M observations
PURPOSE To evaluate the predictive value of a combination model of Liver Imaging Reporting and Data System (LI-RADS)-based magnetic resonance imaging (MRI) and clinicopathologic features to identify atypical hepatocellular carcinoma (HCC) in LI-RADS category M (LR-M) observations. METHODS A total of 105 patients with HCC based on surgery or biopsy who underwent preoperative MRI were retrospectively reviewed in the training group from hospital-1 between December 2016 and November 2020. The LI-RADS-based MRI features and clinicopathologic data were compared between LR-M HCC and non-HCC groups. Univariate and least absolute shrinkage and selection operator regression analyses were used to select the features. Binary logistic regression analysis was then conducted to estimate potential predictors of atypical HCC. A predictive nomogram was established based on the combination of MRI and clinicopathologic features and further validated using an independent external set of data from hospital-2. RESULTS Of 113 observations from 105 patients (mean age, 61 years; 77 men) in the training set, 47 (41.59%) were classified as LR-M HCC. Following multivariate analysis, aspartate aminotransferase >40 U/L [odds ratio (OR): 4.65], alpha-fetoprotein >20 ng/mL (OR: 13.04), surface retraction (OR: 0.16), enhancing capsule (OR: 5.24), blood products in mass (OR: 8.2), and iso/hypoenhancement on delayed phase (OR: 10.26) were found to be independently correlated with LR-M HCC. The corresponding area under the curve for a combined model-based nomogram was 0.95 in the training patients (n = 113) and 0.90 in the validation cohort (n = 53). CONCLUSION The combined model incorporating clinicopathologic and MRI features demonstrated a satisfactory prediction result for LR-M HCC.
- 1 November 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (6) , 741-752
Open AccessA model incorporating clinicopathologic and liver imaging reporting and data system-based magnetic resonance imaging features to identify hepatocellular carcinoma in LR-M observations
PURPOSE To evaluate the predictive value of a combination model of Liver Imaging Reporting and Data System (LI-RADS)-based magnetic resonance imaging (MRI) and clinicopathologic features to identify atypical hepatocellular carcinoma (HCC) in LI-RADS category M (LR-M) observations. METHODS A total of 105 patients with HCC based on surgery or biopsy who underwent preoperative MRI were retrospectively reviewed in the training group from hospital-1 between December 2016 and November 2020. The LI-RADS-based MRI features and clinicopathologic data were compared between LR-M HCC and non-HCC groups. Univariate and least absolute shrinkage and selection operator regression analyses were used to select the features. Binary logistic regression analysis was then conducted to estimate potential predictors of atypical HCC. A predictive nomogram was established based on the combination of MRI and clinicopathologic features and further validated using an independent external set of data from hospital-2. RESULTS Of 113 observations from 105 patients (mean age, 61 years; 77 men) in the training set, 47 (41.59%) were classified as LR-M HCC. Following multivariate analysis, aspartate aminotransferase >40 U/L [odds ratio (OR): 4.65], alpha-fetoprotein >20 ng/mL (OR: 13.04), surface retraction (OR: 0.16), enhancing capsule (OR: 5.24), blood products in mass (OR: 8.2), and iso/hypoenhancement on delayed phase (OR: 10.26) were found to be independently correlated with LR-M HCC. The corresponding area under the curve for a combined model-based nomogram was 0.95 in the training patients (n = 113) and 0.90 in the validation cohort (n = 53). CONCLUSION The combined model incorporating clinicopathologic and MRI features demonstrated a satisfactory prediction result for LR-M HCC.
- Open Access
- 6 October 2023
- Published by Baishideng Publishing Group Inc. in World Journal of Clinical Cases
- Vol. 11 (28) , 6698-6706
Value of ultrasound guided biopsy combined with Xpert Mycobacterium tuberculosis/resistance to rifampin assay in the diagnosis of chest wall tuberculosis
The thoracic wall lesions, particularly chest wall tuberculosis, and chest wall tumors and other pyogenic wall and actinomycetes infections, almost always present as a diagnostic challenge. To explore the value of ultrasound-guided biopsy combined with the Xpert Mycobacterium tuberculosis/resistance to rifampin (MTB/RIF) assay to diagnose chest wall tuberculosis. We performed a retrospective study of patients with chest wall lesions from March 2018 to March 2021. All patients received the ultrasound-guided biopsy for pathology examination, acid-fast Bacillus staining, mycobacterial culture, and Xpert MTB/RIF analysis. The sensitivity, specificity, and area under the curve (AUC) were calculated for these diagnostic tests, either individually or combined. Rifampicin resistance results were compared between the mycobacterial culture and the Xpert MTB/RIF assay. In 31 patients with the chest wall lesion biopsy, 22 patients were diagnosed with chest wall tuberculosis. Of them, 3, 6, and 21 patients tested positive for mycobacterial culture, acid-fast stain, and Xpert MTB/RIF assay, respectively. The rifampicin resistance results of the 3 culture-positive patients were consistent with their Xpert MTB/RIF assay results. When considering the sensitivity, specificity, and AUC value, the Xpert MTB/RIF assay (95.5%, 88.9%, and 0.92, respectively) was a better choice than the acid-fast Bacillus stain (27.3%, 100.0%, and 0.64, respectively) and mycobacterial culture (13.6%, 100.0%, 0.57, respectively). No complications were reported during the procedure. Ultrasound guided biopsy combined with Xpert MTB/RIF has high value in the diagnosis of chest wall tuberculosis, and can also detect rifampicin resistance.
- 6 October 2023
- Published by Baishideng Publishing Group Inc. in World Journal of Clinical Cases
- Vol. 11 (28) , 6698-6706
Open AccessValue of ultrasound guided biopsy combined with Xpert Mycobacterium tuberculosis/resistance to rifampin assay in the diagnosis of chest wall tuberculosis
The thoracic wall lesions, particularly chest wall tuberculosis, and chest wall tumors and other pyogenic wall and actinomycetes infections, almost always present as a diagnostic challenge. To explore the value of ultrasound-guided biopsy combined with the Xpert Mycobacterium tuberculosis/resistance to rifampin (MTB/RIF) assay to diagnose chest wall tuberculosis. We performed a retrospective study of patients with chest wall lesions from March 2018 to March 2021. All patients received the ultrasound-guided biopsy for pathology examination, acid-fast Bacillus staining, mycobacterial culture, and Xpert MTB/RIF analysis. The sensitivity, specificity, and area under the curve (AUC) were calculated for these diagnostic tests, either individually or combined. Rifampicin resistance results were compared between the mycobacterial culture and the Xpert MTB/RIF assay. In 31 patients with the chest wall lesion biopsy, 22 patients were diagnosed with chest wall tuberculosis. Of them, 3, 6, and 21 patients tested positive for mycobacterial culture, acid-fast stain, and Xpert MTB/RIF assay, respectively. The rifampicin resistance results of the 3 culture-positive patients were consistent with their Xpert MTB/RIF assay results. When considering the sensitivity, specificity, and AUC value, the Xpert MTB/RIF assay (95.5%, 88.9%, and 0.92, respectively) was a better choice than the acid-fast Bacillus stain (27.3%, 100.0%, and 0.64, respectively) and mycobacterial culture (13.6%, 100.0%, 0.57, respectively). No complications were reported during the procedure. Ultrasound guided biopsy combined with Xpert MTB/RIF has high value in the diagnosis of chest wall tuberculosis, and can also detect rifampicin resistance.
- Open Access
- 1 September 2023
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (9) , 5676-5687
Quantification of bone quality and distribution of the proximal humerus with dual-energy computed tomography
Background: The proximal humerus is a common site of osteoporotic fractures, and bone quality is a predictor of surgical reduction quality. Dual-energy computed tomography (DECT) is assuming an increasingly important role in the quantification of bone mineral density (BMD) due it is ability to perform three-material decomposition. We aimed to analyze the bone quality and distribution of the proximal humerus with DECT quantitatively. Methods: Sixty-five consecutive patients (average age 49.5±15.2 years; male: female ratio 32:33) without proximal humerus fractures who had undergone DECT were retrospectively selected. The humeral head was divided into 4 regions on a cross section in the medial plane between the greater tuberosity and the surgical neck. The quantitative parameters, including virtual noncalcium (VNCa) value, computed tomography value of calcium (CaCT), computed tomography value of mixed-energy images (regular CT value) (rCT), and relative calcium density (rCaD), were measured. The correlations between the quantitative parameters and age and body mass index (BMI) were analyzed, and the correlations of age, sex, BMI, region of the humeral head, and VNCa value on CaCT were evaluated. Results: The differences in CaCT, rCT, and rCaD between the 4 regions of proximal humerus were statistically significant (P0.05). Multivariable linear regression analysis indicated that sex, age, BMI, regions, and VNCa were significant (PConclusions: The concentration of calcium was the densest in the posteromedial region of proximal humerus, and the VNCa value of DECT may be used for quantifying the BMD of the proximal humerus.
- 1 September 2023
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (9) , 5676-5687
Open AccessQuantification of bone quality and distribution of the proximal humerus with dual-energy computed tomography
Background: The proximal humerus is a common site of osteoporotic fractures, and bone quality is a predictor of surgical reduction quality. Dual-energy computed tomography (DECT) is assuming an increasingly important role in the quantification of bone mineral density (BMD) due it is ability to perform three-material decomposition. We aimed to analyze the bone quality and distribution of the proximal humerus with DECT quantitatively. Methods: Sixty-five consecutive patients (average age 49.5±15.2 years; male: female ratio 32:33) without proximal humerus fractures who had undergone DECT were retrospectively selected. The humeral head was divided into 4 regions on a cross section in the medial plane between the greater tuberosity and the surgical neck. The quantitative parameters, including virtual noncalcium (VNCa) value, computed tomography value of calcium (CaCT), computed tomography value of mixed-energy images (regular CT value) (rCT), and relative calcium density (rCaD), were measured. The correlations between the quantitative parameters and age and body mass index (BMI) were analyzed, and the correlations of age, sex, BMI, region of the humeral head, and VNCa value on CaCT were evaluated. Results: The differences in CaCT, rCT, and rCaD between the 4 regions of proximal humerus were statistically significant (P0.05). Multivariable linear regression analysis indicated that sex, age, BMI, regions, and VNCa were significant (PConclusions: The concentration of calcium was the densest in the posteromedial region of proximal humerus, and the VNCa value of DECT may be used for quantifying the BMD of the proximal humerus.
- 26 April 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 164, 110848
Relationship between diffuse fibrosis assessed by CMR and depressed myocardial strain in different stages of heart failure
- 26 April 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 164, 110848
Relationship between diffuse fibrosis assessed by CMR and depressed myocardial strain in different stages of heart failure
- Open Access
- 15 December 2022
- Published by Wiley in Orthopaedic Surgery
- Vol. 15 (8) , 2025-2032
A Novel and Open Classification Emphasizing on Osteoligamentous Complex for Distal Clavicle Fractures
ObjectiveCurrent X-ray-based classification methods cannot describe all distal clavicle fracture (DCF) patterns, especially the osteoligamentous injury pattern of DCFs. We aimed to develop a novel classification based on the osteoligamentous injury pattern of the DCFs and investigated its reliability. MethodsAll DCFs from January 2017 to January 2022 were respectively screened and 45 cases (mean age 20-78; male 31, female 14) met the including criteria and were enrolled. Based on their Zanca view X-ray radiograph and three-dimensional CT construction images, we analyzed the osteoligamentous injury pattern of each case, particularly the acromioclavicular (AC) and coracoclavicular ligaments and their bone attachment. Then we developed a novel classification method, five types in total, sorting all DCFs according to their lesion manifestations of osteoligamentous complex. Also, we investigated the inter- and intra-observer reliability using kappa value. ResultsA novel classification method for DCF was developed, manifesting the avulsion or rupture of conoid and trapezoid ligaments, and involvement of AC joint. Forty-five cases of DCFs were included in this study. Among them, 11 (24.4%) were Type 1 fracture, three (6.7%) cases were Type 2, six cases (13.3%) were Type 3, 21 (46.7%) were Type 4, four (8.9%) were Type 5. Kappa values for inter-observer agreement were 0.57 after first evaluation and 0.61 after second evaluation. Intra-observer agreement was 0.72 for experienced shoulder specialist and 0.63 for radiologist. ConclusionThis new classification method is reliable to use, supplementary to current classification systems, and emphasizes on the osteoligamentous complex injury when opting for the treatment.
- 15 December 2022
- Published by Wiley in Orthopaedic Surgery
- Vol. 15 (8) , 2025-2032
Open AccessA Novel and Open Classification Emphasizing on Osteoligamentous Complex for Distal Clavicle Fractures
ObjectiveCurrent X-ray-based classification methods cannot describe all distal clavicle fracture (DCF) patterns, especially the osteoligamentous injury pattern of DCFs. We aimed to develop a novel classification based on the osteoligamentous injury pattern of the DCFs and investigated its reliability. MethodsAll DCFs from January 2017 to January 2022 were respectively screened and 45 cases (mean age 20-78; male 31, female 14) met the including criteria and were enrolled. Based on their Zanca view X-ray radiograph and three-dimensional CT construction images, we analyzed the osteoligamentous injury pattern of each case, particularly the acromioclavicular (AC) and coracoclavicular ligaments and their bone attachment. Then we developed a novel classification method, five types in total, sorting all DCFs according to their lesion manifestations of osteoligamentous complex. Also, we investigated the inter- and intra-observer reliability using kappa value. ResultsA novel classification method for DCF was developed, manifesting the avulsion or rupture of conoid and trapezoid ligaments, and involvement of AC joint. Forty-five cases of DCFs were included in this study. Among them, 11 (24.4%) were Type 1 fracture, three (6.7%) cases were Type 2, six cases (13.3%) were Type 3, 21 (46.7%) were Type 4, four (8.9%) were Type 5. Kappa values for inter-observer agreement were 0.57 after first evaluation and 0.61 after second evaluation. Intra-observer agreement was 0.72 for experienced shoulder specialist and 0.63 for radiologist. ConclusionThis new classification method is reliable to use, supplementary to current classification systems, and emphasizes on the osteoligamentous complex injury when opting for the treatment.