Chenyang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chenyang Liu has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Jing Cai
The Hong Kong Polytechnic University
7 shared publications - Tian Li
The Hong Kong Polytechnic University
5 shared publications - Wen Li
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, China
4 shared publications Haonan Xiao
Department of Radiation Oncology and Physics, Shandong Cancer Hospital and Institute, Huaiyin District, Jinan, 250117, CHINA
3 shared publicationsPeng Cao
Department of Diagnostic Radiology, The University of Hong Kong, 999077, Hong Kong Special Administrative Region of China
3 shared publicationsVictor Ho-Fun Lee
Department of Clinical Oncology, Queen Mary Hospital, 999077, Hong Kong Special Administrative Region of China
3 shared publications
Latest Publications
- 3 August 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 114, 104240
Self-supervised reconstruction framework via motion- and physics-informed learning for four-dimensional magnetic resonance fingerprinting
- 3 August 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 114, 104240
Self-supervised reconstruction framework via motion- and physics-informed learning for four-dimensional magnetic resonance fingerprinting
- Open Access
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
Motion-robust magnetic resonance fingerprinting (MR-MRF) for quantitative liver cancer imaging
Objective: This study aims to develop a motion-robust magnetic resonance fingerprinting (MR-MRF) technique for liver cancer imaging to eliminate the need for breath-hold scanning. Approach: To mitigate respiratory motion artifacts in free-breathing abdominal MRF, the MR-MRF technique comprising two core components. First, respiratory motion is modeled by applying an isotropic total variation (TV)-regularized registration algorithm between a target end-of-exhalation (EOE) phase and three motion phases. Second, motion-resolved tissue property maps are reconstructed using a low-rank total variation (LRTV) optimization framework, which incorporates the estimated inter-phase motion to align all acquired MRF dynamics to the EOE phase. MR-MRF is evaluated by 22 patients (mean age, 62 years ± 10 [SD]; 15 males and 7 females) with hepatocellular carcinoma. Radiologist’s blinded assessment and organ boundary sharpness measurements are performed to evaluate the image quality of MR-MRF-derived tissue maps. The test-retest tissue quantification repeatability is assessed by two consecutive MRF scans with distinct breathing patterns. Paired Student’s t-test is used for statistical significance analysis with a p-value threshold of 0.05. Main results: MR-MRF achieved successful reconstruction of motion-resolved tissue maps at EOE phase, with blinded radiologist assessment yielding an average score of 3 (moderate quality - sufficient for diagnosis) for overall image impression. The FWHM of organ boundaries in MR-MRF-derived tissue maps is 3.1mm ± 1.7mm, significantly lower than motion-blurred tissue maps (9.9mm ± 3.4mm, p-value<0.0001). Test-retest analysis demonstrated good repeatability: liver coefficient of variation was 5.5% ± 7.1% (T1), 8.2% ± 4.4% (T2), and 5.0% ± 2.0% (PD), with excellent linear agreement (R² = 0.96, 0.80, and 0.85 for T1, T2, and PD, respectively). Significance: This study establishes the technical foundation of MR-MRF to achieve repeatable and quantitative liver T1/T2/PD mapping under free-breathing conditions at 3T. The results validate the feasibility of addressing respiratory motion in abdominal multi-parametric quantitative MRI.
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
Open AccessMotion-robust magnetic resonance fingerprinting (MR-MRF) for quantitative liver cancer imaging
Objective: This study aims to develop a motion-robust magnetic resonance fingerprinting (MR-MRF) technique for liver cancer imaging to eliminate the need for breath-hold scanning. Approach: To mitigate respiratory motion artifacts in free-breathing abdominal MRF, the MR-MRF technique comprising two core components. First, respiratory motion is modeled by applying an isotropic total variation (TV)-regularized registration algorithm between a target end-of-exhalation (EOE) phase and three motion phases. Second, motion-resolved tissue property maps are reconstructed using a low-rank total variation (LRTV) optimization framework, which incorporates the estimated inter-phase motion to align all acquired MRF dynamics to the EOE phase. MR-MRF is evaluated by 22 patients (mean age, 62 years ± 10 [SD]; 15 males and 7 females) with hepatocellular carcinoma. Radiologist’s blinded assessment and organ boundary sharpness measurements are performed to evaluate the image quality of MR-MRF-derived tissue maps. The test-retest tissue quantification repeatability is assessed by two consecutive MRF scans with distinct breathing patterns. Paired Student’s t-test is used for statistical significance analysis with a p-value threshold of 0.05. Main results: MR-MRF achieved successful reconstruction of motion-resolved tissue maps at EOE phase, with blinded radiologist assessment yielding an average score of 3 (moderate quality - sufficient for diagnosis) for overall image impression. The FWHM of organ boundaries in MR-MRF-derived tissue maps is 3.1mm ± 1.7mm, significantly lower than motion-blurred tissue maps (9.9mm ± 3.4mm, p-value<0.0001). Test-retest analysis demonstrated good repeatability: liver coefficient of variation was 5.5% ± 7.1% (T1), 8.2% ± 4.4% (T2), and 5.0% ± 2.0% (PD), with excellent linear agreement (R² = 0.96, 0.80, and 0.85 for T1, T2, and PD, respectively). Significance: This study establishes the technical foundation of MR-MRF to achieve repeatable and quantitative liver T1/T2/PD mapping under free-breathing conditions at 3T. The results validate the feasibility of addressing respiratory motion in abdominal multi-parametric quantitative MRI.
- Open Access
- 28 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235025
Enhanced 4D diffusion-weighted PROPELLER echo-planar imaging with collaborative blade reconstruction
Objective. Four-dimensional diffusion-weighted imaging (4D-DWI) offers enhanced soft-tissue contrast for image-guided radiotherapy (IGRT) compared to conventional 4D-magnetic resonance imaging. However, its clinical application has been hindered by geometric distortion or prolonged acquisition times. This study introduces an improved respiratory-correlated 4D-DWI technique to address these critical limitations. Approach. The proposed 4D-DW-PROP-EPI-JBCR technique consists of four stages: data acquisition, coil sensitivity and phase error maps estimation, retrospective data sorting, and a joint-blade collaborative reconstruction (JBCR) step. We evaluated its performance against the previous 4D-DW-PROPELLER-EPI using both simulations and in vivo experiments. Evaluation metrics included k -space uniformity requirements, point spread function (PSF) quality, minimum required sampling factor (SF), image quality, geometric fidelity, and acquisition time. Image quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity (SSIM), high-frequency error norm (HFEN), and signal-to-noise ratio (SNR); geometric fidelity was evaluated via Dice similarity coefficient (DSC) and Hausdorff distance (HD). Paired t -tests were used for metric comparisons, with statistical significance set at P < 0.05. Main results. Compared to 4D-DW-PROPELLER-EPI, the proposed 4D-DW-PROP-EPI-JBCR eliminated the requirement for strict k -space uniformity while achieving enhanced PSFs with fewer acquisitions. Additionally, 4D-DW-PROP-EPI-JBCR yielded significant improvements in image quality compared to 4D-DW-PROPELLER-EPI across all key metrics: SSIM (0.83–0.92 vs 0.81–0.90, P < 0.05), PSNR (20.56–25.20 vs 20.24–24.48, P < 0.05), HFEN (0.49–0.678 vs 0.52–0.80, P < 0.05), and SNR (31.1–32.6 dB vs 28.6–29.5 dB, P < 0.05). It also exhibited excellent geometric fidelity, as evidenced by DSC (0.90 ± 0.03) and HD (2.37 ± 1.12). Notably, these performance gains were achieved with an SF of 1.9 per diffusion direction, compared to the SF of 2.4 for 4D-DW-PROPELLER-EPI. Significance. By enabling distortion-free respiratory-correlated 4D-DWI and reducing SF by more than 20% compared to 4D-DW-PROPELLER-EPI, the 4D-DW-PROP-EPI-JBCR technique markedly improves the clinical utility of 4D-DWI for abdominal IGRT.
- 28 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235025
Open AccessEnhanced 4D diffusion-weighted PROPELLER echo-planar imaging with collaborative blade reconstruction
Objective. Four-dimensional diffusion-weighted imaging (4D-DWI) offers enhanced soft-tissue contrast for image-guided radiotherapy (IGRT) compared to conventional 4D-magnetic resonance imaging. However, its clinical application has been hindered by geometric distortion or prolonged acquisition times. This study introduces an improved respiratory-correlated 4D-DWI technique to address these critical limitations. Approach. The proposed 4D-DW-PROP-EPI-JBCR technique consists of four stages: data acquisition, coil sensitivity and phase error maps estimation, retrospective data sorting, and a joint-blade collaborative reconstruction (JBCR) step. We evaluated its performance against the previous 4D-DW-PROPELLER-EPI using both simulations and in vivo experiments. Evaluation metrics included k -space uniformity requirements, point spread function (PSF) quality, minimum required sampling factor (SF), image quality, geometric fidelity, and acquisition time. Image quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity (SSIM), high-frequency error norm (HFEN), and signal-to-noise ratio (SNR); geometric fidelity was evaluated via Dice similarity coefficient (DSC) and Hausdorff distance (HD). Paired t -tests were used for metric comparisons, with statistical significance set at P < 0.05. Main results. Compared to 4D-DW-PROPELLER-EPI, the proposed 4D-DW-PROP-EPI-JBCR eliminated the requirement for strict k -space uniformity while achieving enhanced PSFs with fewer acquisitions. Additionally, 4D-DW-PROP-EPI-JBCR yielded significant improvements in image quality compared to 4D-DW-PROPELLER-EPI across all key metrics: SSIM (0.83–0.92 vs 0.81–0.90, P < 0.05), PSNR (20.56–25.20 vs 20.24–24.48, P < 0.05), HFEN (0.49–0.678 vs 0.52–0.80, P < 0.05), and SNR (31.1–32.6 dB vs 28.6–29.5 dB, P < 0.05). It also exhibited excellent geometric fidelity, as evidenced by DSC (0.90 ± 0.03) and HD (2.37 ± 1.12). Notably, these performance gains were achieved with an SF of 1.9 per diffusion direction, compared to the SF of 2.4 for 4D-DW-PROPELLER-EPI. Significance. By enabling distortion-free respiratory-correlated 4D-DWI and reducing SF by more than 20% compared to 4D-DW-PROPELLER-EPI, the 4D-DW-PROP-EPI-JBCR technique markedly improves the clinical utility of 4D-DWI for abdominal IGRT.
- 25 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (1) , 100-109
Model Generalizability Investigation for GFCE-MRI Synthesis in NPC Radiotherapy Using Multi-Institutional Patient-Based Data Normalization
Recently, deep learning has been demonstrated to be feasible in eliminating the use of gadolinium-based contrast agents (GBCAs) through synthesizing gadolinium-free contrast-enhanced MRI (GFCE-MRI) from contrast-free MRI sequences, pro-viding the community with an alternative to get rid of GBCAs-associated safety issues in patients. Nevertheless, generalizability assessment of the GFCE-MRI model has been largely challenged by the high inter-institutional heterogeneity of MRI data, on top of the scarcity of multi-institutional data itself. Although various data normalization methods have been adopted in previous studies to address the heterogeneity issue, it has been limited to single-institutional investigation and there is no standard normalization approach presently. In this study, we aimed at investigating gener-alizability of GFCE-MRI model using data from seven institutions by manipulating heterogeneity of training MRI data under five popular normalization approaches. Three state-of-the-art neural networks were applied to map from T1-weighted and T2-weighted MRI to contrast-enhanced MRI (CE-MRI) for GFCE-MRI synthesis in patients with nasopharyngeal carcinoma. MRI data from three institutions were used separately to generate three uni-institution models and jointly for a tri-institution model. The five normalization methods were applied to normalize the training and testing data of each model. MRI data from the remaining four institutions served as external cohorts for model generalizability assessment. Quality of GFCE-MRI was quantitatively evaluated against ground-truth CE-MRI using mean absolute error (MAE) and peak signal-to-noise ratio (PSNR). Results showed that performance of all uni-institution models remarkably dropped on the external cohorts. By contrast, model trained using multi-institutional data with Z-Score normalization yielded the best model generalizability improvement.
- 25 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (1) , 100-109
Model Generalizability Investigation for GFCE-MRI Synthesis in NPC Radiotherapy Using Multi-Institutional Patient-Based Data Normalization
Recently, deep learning has been demonstrated to be feasible in eliminating the use of gadolinium-based contrast agents (GBCAs) through synthesizing gadolinium-free contrast-enhanced MRI (GFCE-MRI) from contrast-free MRI sequences, pro-viding the community with an alternative to get rid of GBCAs-associated safety issues in patients. Nevertheless, generalizability assessment of the GFCE-MRI model has been largely challenged by the high inter-institutional heterogeneity of MRI data, on top of the scarcity of multi-institutional data itself. Although various data normalization methods have been adopted in previous studies to address the heterogeneity issue, it has been limited to single-institutional investigation and there is no standard normalization approach presently. In this study, we aimed at investigating gener-alizability of GFCE-MRI model using data from seven institutions by manipulating heterogeneity of training MRI data under five popular normalization approaches. Three state-of-the-art neural networks were applied to map from T1-weighted and T2-weighted MRI to contrast-enhanced MRI (CE-MRI) for GFCE-MRI synthesis in patients with nasopharyngeal carcinoma. MRI data from three institutions were used separately to generate three uni-institution models and jointly for a tri-institution model. The five normalization methods were applied to normalize the training and testing data of each model. MRI data from the remaining four institutions served as external cohorts for model generalizability assessment. Quality of GFCE-MRI was quantitatively evaluated against ground-truth CE-MRI using mean absolute error (MAE) and peak signal-to-noise ratio (PSNR). Results showed that performance of all uni-institution models remarkably dropped on the external cohorts. By contrast, model trained using multi-institutional data with Z-Score normalization yielded the best model generalizability improvement.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (1) , 162-174
Coarse–Super-Resolution–Fine Network (CoSF-Net): A Unified End-to-End Neural Network for 4D-MRI With Simultaneous Motion Estimation and Super-Resolution
Four-dimensional magnetic resonance imaging (4D-MRI) is an emerging technique for tumor motion management in image-guided radiation therapy (IGRT). However, current 4D-MRI suffers from low spatial resolution and strong motion artifacts owing to the long acquisition time and patients’ respiratory variations. If not managed properly, these limitations can adversely affect treatment planning and delivery in IGRT. In this study, we developed a novel deep learning framework called the coarse–super-resolution–fine network (CoSF-Net) to achieve simultaneous motion estimation and super-resolution within a unified model. We designed CoSF-Net by fully excavating the inherent properties of 4D-MRI, with consideration of limited and imperfectly matched training datasets. We conducted extensive experiments on multiple real patient datasets to assess the feasibility and robustness of the developed network. Compared with existing networks and three state-of-the-art conventional algorithms, CoSF-Net not only accurately estimated the deformable vector fields between the respiratory phases of 4D-MRI but also simultaneously improved the spatial resolution of 4D-MRI, enhancing anatomical features and producing 4D-MR images with high spatiotemporal resolution.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (1) , 162-174
Coarse–Super-Resolution–Fine Network (CoSF-Net): A Unified End-to-End Neural Network for 4D-MRI With Simultaneous Motion Estimation and Super-Resolution
Four-dimensional magnetic resonance imaging (4D-MRI) is an emerging technique for tumor motion management in image-guided radiation therapy (IGRT). However, current 4D-MRI suffers from low spatial resolution and strong motion artifacts owing to the long acquisition time and patients’ respiratory variations. If not managed properly, these limitations can adversely affect treatment planning and delivery in IGRT. In this study, we developed a novel deep learning framework called the coarse–super-resolution–fine network (CoSF-Net) to achieve simultaneous motion estimation and super-resolution within a unified model. We designed CoSF-Net by fully excavating the inherent properties of 4D-MRI, with consideration of limited and imperfectly matched training datasets. We conducted extensive experiments on multiple real patient datasets to assess the feasibility and robustness of the developed network. Compared with existing networks and three state-of-the-art conventional algorithms, CoSF-Net not only accurately estimated the deformable vector fields between the respiratory phases of 4D-MRI but also simultaneously improved the spatial resolution of 4D-MRI, enhancing anatomical features and producing 4D-MR images with high spatiotemporal resolution.
- 27 April 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , 493-504
Respiratory-Correlated 4-Dimensional Magnetic Resonance Fingerprinting for Liver Cancer Radiation Therapy Motion Management
- 27 April 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , 493-504
Respiratory-Correlated 4-Dimensional Magnetic Resonance Fingerprinting for Liver Cancer Radiation Therapy Motion Management
- Open Access
- 16 June 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-10
Building reliable radiomic models using image perturbation
Radiomic model reliability is a central premise for its clinical translation. Presently, it is assessed using test–retest or external data, which, unfortunately, is often scarce in reality. Therefore, we aimed to develop a novel image perturbation-based method (IPBM) for the first of its kind toward building a reliable radiomic model. We first developed a radiomic prognostic model for head-and-neck cancer patients on a training (70%) and evaluated on a testing (30%) cohort using C-index. Subsequently, we applied the IPBM to CT images of both cohorts (Perturbed-Train and Perturbed-Test cohort) to generate 60 additional samples for both cohorts. Model reliability was assessed using intra-class correlation coefficient (ICC) to quantify consistency of the C-index among the 60 samples in the Perturbed-Train and Perturbed-Test cohorts. Besides, we re-trained the radiomic model using reliable RFs exclusively (ICC > 0.75) to validate the IPBM. Results showed moderate model reliability in Perturbed-Train (ICC: 0.565, 95%CI 0.518–0.615) and Perturbed-Test (ICC: 0.596, 95%CI 0.527–0.670) cohorts. An enhanced reliability of the re-trained model was observed in Perturbed-Train (ICC: 0.782, 95%CI 0.759–0.815) and Perturbed-Test (ICC: 0.825, 95%CI 0.782–0.867) cohorts, indicating validity of the IPBM. To conclude, we demonstrated capability of the IPBM toward building reliable radiomic models, providing community with a novel model reliability assessment strategy prior to prospective evaluation.
- 16 June 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-10
Open AccessBuilding reliable radiomic models using image perturbation
Radiomic model reliability is a central premise for its clinical translation. Presently, it is assessed using test–retest or external data, which, unfortunately, is often scarce in reality. Therefore, we aimed to develop a novel image perturbation-based method (IPBM) for the first of its kind toward building a reliable radiomic model. We first developed a radiomic prognostic model for head-and-neck cancer patients on a training (70%) and evaluated on a testing (30%) cohort using C-index. Subsequently, we applied the IPBM to CT images of both cohorts (Perturbed-Train and Perturbed-Test cohort) to generate 60 additional samples for both cohorts. Model reliability was assessed using intra-class correlation coefficient (ICC) to quantify consistency of the C-index among the 60 samples in the Perturbed-Train and Perturbed-Test cohorts. Besides, we re-trained the radiomic model using reliable RFs exclusively (ICC > 0.75) to validate the IPBM. Results showed moderate model reliability in Perturbed-Train (ICC: 0.565, 95%CI 0.518–0.615) and Perturbed-Test (ICC: 0.596, 95%CI 0.527–0.670) cohorts. An enhanced reliability of the re-trained model was observed in Perturbed-Train (ICC: 0.782, 95%CI 0.759–0.815) and Perturbed-Test (ICC: 0.825, 95%CI 0.782–0.867) cohorts, indicating validity of the IPBM. To conclude, we demonstrated capability of the IPBM toward building reliable radiomic models, providing community with a novel model reliability assessment strategy prior to prospective evaluation.