Nour. T. Abdel-Ghani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nour. T. Abdel-Ghani has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Mostafa Ahmed Samy
Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
1 shared publication - Muhammed Abdel-Hamied Abdel-Tawab
Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert Einstein Allee, 11, 89081 Ulm, Germany
1 shared publication - Rasha Mohamed El Nashar
Chemistry Department, Faculty of Science, Cairo University, Egypt
1 shared publication
Latest Publications
- Open Access
- 27 April 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (5) , 262
Application of Molecularly Imprinted Microelectrode as a Promising Point-of-Care Biosensor for Alanine Aminotransferase Enzyme
Alanine amino transaminase (ALT) is an enzyme that can be used as a biomarker for liver injury and other diseases. In this work, we report the development of the first microelectrode based on a molecularly imprinted pyruvate oxidase enzyme to be applied as an electrochemical biosensor for ALT detection. The biosensor is based on pyruvate oxidase enzyme (POx), imprinted using 4-aminophenol (functional monomer-on-platinum microelectrode modified (PME)) with platinum nanoparticles and 4-aminoantypirine (4-AAP)/sodium pyruvate as an electrochemical indicator. The operational conditions of the biosensor were optimized and characterized morphologically using scanning electron microscopy (SEM) and electrochemically using electrochemical impedance spectroscopy (EIS). The biosensor was found to have a fast response towards ALT within a linear range of 25–700 U/L and a limit of detection of 2.97 U/L. The biosensor did not exhibit cross-reactivity towards other tested enzymes, including nicotinamide adenine dinucleotide (Beta-NAD), catalase (CAT), glutathione peroxidase (GPx), and L-glutathione reduced (GSH) enzymes. The biosensor was efficiently applied for the assay of ALT in plasma samples; with recovery values ranging from 99.80–103.82% and RSD of values 0.27–2.01% and these results were found to be comparable to those of the reference diagnostic kits, without any need for complicated procedures or protein extraction. In addition to being highly sensitive, low cost, and portable, the use of microelectrodes allows the application of the proposed sensor for point-of-care diagnostics of liver function and online monitoring of ALT levels in hospitalized patients without the need for withdrawing samples, which indicates the promising applicability of the presented ALT sensor for point-of-care diagnostics.
- 27 April 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (5) , 262
Open AccessApplication of Molecularly Imprinted Microelectrode as a Promising Point-of-Care Biosensor for Alanine Aminotransferase Enzyme
Alanine amino transaminase (ALT) is an enzyme that can be used as a biomarker for liver injury and other diseases. In this work, we report the development of the first microelectrode based on a molecularly imprinted pyruvate oxidase enzyme to be applied as an electrochemical biosensor for ALT detection. The biosensor is based on pyruvate oxidase enzyme (POx), imprinted using 4-aminophenol (functional monomer-on-platinum microelectrode modified (PME)) with platinum nanoparticles and 4-aminoantypirine (4-AAP)/sodium pyruvate as an electrochemical indicator. The operational conditions of the biosensor were optimized and characterized morphologically using scanning electron microscopy (SEM) and electrochemically using electrochemical impedance spectroscopy (EIS). The biosensor was found to have a fast response towards ALT within a linear range of 25–700 U/L and a limit of detection of 2.97 U/L. The biosensor did not exhibit cross-reactivity towards other tested enzymes, including nicotinamide adenine dinucleotide (Beta-NAD), catalase (CAT), glutathione peroxidase (GPx), and L-glutathione reduced (GSH) enzymes. The biosensor was efficiently applied for the assay of ALT in plasma samples; with recovery values ranging from 99.80–103.82% and RSD of values 0.27–2.01% and these results were found to be comparable to those of the reference diagnostic kits, without any need for complicated procedures or protein extraction. In addition to being highly sensitive, low cost, and portable, the use of microelectrodes allows the application of the proposed sensor for point-of-care diagnostics of liver function and online monitoring of ALT levels in hospitalized patients without the need for withdrawing samples, which indicates the promising applicability of the presented ALT sensor for point-of-care diagnostics.