Klaudia Malisz

Klaudia Malisz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Klaudia Malisz has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Voltage and Deposition Time on Surface Morphology, Mechanical Performance, and Corrosion Resistance of Chitosan–Nanohydroxyapatite Coatings

    by Klaudia Malisz-Rudzińska, Joanna Sypniewska, Marlena Grodzicka, Aleksandra Mirowska, Aleksandra Mielewczyk-Gryń, Beata Świeczko-Żurek, Alina Sionkowska

    This study investigates the damage behavior and surface integrity of chitosan–nanohydroxyapatite (CS/nHAp) composite coatings, along with their corrosion resistance and wettability, which directly affect their biological performance in vivo. The coatings were deposited on Ti13Zr13Nb and stainless steel using electrophoretic deposition (EPD) at various voltages and deposition times. Surface topography, morphology, composition, and roughness were characterized using microscopic techniques, while wettability, corrosion resistance, and mechanical properties were assessed. Three-point bending tests were performed to determine coating behavior under mechanical deformation. Hydrophilic, homogeneous CS/nHAp coatings were successfully deposited without visible cracks on the surface. Coatings deposited at 10 V exhibited higher corrosion potentials compared to uncoated titanium alloy. Mechanical testing showed that coatings deposited at 10 V were significantly harder than those deposited at 20 V. The CS/nHAp20_5 coating exhibited moderate hardness (0.33 ± 0.06 GPa), the lowest Young’s modulus (12.7 ± 1.4 GPa), increased flexibility, and good adhesion, without delamination during bending tests. These results demonstrate that by modifying deposition parameters, it is possible to adjust the mechanical and protective properties of CS/nHAp coatings for potential application of the developed coating in vascular stents.

  • Design of bioactive chitosan-adenosine composite coatings for vascular stents

    by Klaudia Malisz-Rudzińska, Gilles Pécastaings, Alicja Braczko, Barbara Kutryb-Zając, Marlena Grodzicka, Jérémy Guitard, Dorota Bociaga, Bartłomiej Mirowski, Beata Świeczko-Żurek, Marcin Hellmann


  • Open Access

    Study of nanohydroxyapatite composites loaded with gentamicin sulfate and silver nanoparticles

    by Klaudia Malisz, Beata Świeczko – Żurek, Jakub Karczewski, Aleksandra Mirowska, Anna Pałubicka


  • Open Access

    Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters

    by Klaudia Malisz, Beata Świeczko-Żurek, Jean-Marc Olive, Grzegorz Gajowiec, Gilles Pecastaings, Aleksandra Laska, Alina Sionkowska

    The aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy (EDS), Atomic Force Microscopy (AFM), optical profilometer, drop shape analyzer, and a nanoscratch tester. All of the coatings are homogeneous without any agglomerates. When low voltage (10 V) was used, the coatings were uniform and continuous regardless of the deposition time. The increase in voltage resulted in the formation of cracks in the coatings. The wettability test shows the hydrophilic behavior of the coatings and the mean contact angle values are in the range of 20–37°. The coatings showed excellent adhesion to the substrate. The application of a maximum force of 400 mN did not cause delamination in most coatings. It is concluded that the optimal coating for orthopedic implants (such as hip joint implants, knee joint implants or facial elements) is obtained at 10 V and 5 min because of its homogeneity, and a contact angle that promotes osseointegration and great adhesion to the substrate.


  • Research of chitosan coatings deposited by electrophoretic deposition method at various voltage and time parameters

    by Klaudia Malisz, Beata Świeczko-Żurek, Jean-Marc Olive, Gilles Pecastaings, Alina Sionkowska, Aleksandra Laska, Grzegorz Gajowiec


  • Open Access

    Antimicrobial and Antiproliferative Coatings for Stents in Veterinary Medicine—State of the Art and Perspectives

    by Szymon Graczyk, Robert Pasławski, Arkadiusz Grzeczka, Urszula Pasławska, Beata Świeczko-Żurek, Klaudia Malisz, Ketul Popat, Alina Sionkowska, Patrycja Golińska, Mahendra Rai

    Microbial colonization in veterinary stents poses a significant and concerning issue in veterinary medicine. Over time, these pathogens, particularly bacteria, can colonize the stent surfaces, leading to various complications. Two weeks following the stent insertion procedure, the colonization becomes observable, with the aggressiveness of bacterial growth directly correlating with the duration of stent placement. Such microbial colonization can result in infections and inflammations, compromising the stent’s efficacy and, subsequently, the animal patient’s overall well-being. Managing and mitigating the impact of these pathogens on veterinary stents is a crucial challenge that veterinarians and researchers are actively addressing to ensure the successful treatment and recovery of their animal patients. In addition, irritation of the tissue in the form of an inserted stent can lead to overgrowth of granulation tissue, leading to the closure of the stent lumen, as is most often the case in the trachea. Such serious complications after stent placement require improvements in the procedures used to date. In this review, antibacterial or antibiofilm strategies for several stents used in veterinary medicine have been discussed based on the current literature and the perspectives have been drawn. Various coating strategies such as coating with hydrogel, antibiotic, or other antimicrobial agents have been reviewed.


  • Open Access

    Graphene Production and Biomedical Applications: A Review

    by Klaudia Malisz, Beata Świeczko-Żurek

    Graphene is a two-dimensional nanomaterial composed of carbon atoms with sp2 hybrid orbitals. Both graphene and graphene-based composite have gained broad interest among researchers because of their outstanding physiochemical, mechanical, and biological properties. Graphene production techniques are divided into top-down and bottom-up synthesis methods, of which chemical vapor deposition (CVD) is the most popular. The biomedical applications of graphene and its composite include its use in sensors, implantology, and gene and drug delivery. They can be used for tissue engineering, anticancer therapies, and as antimicrobial agents in implant application. The biocompatibility of graphene-based nanomaterials enables their use in the field of biomedicine. This article reviews the properties of graphene, the methods used to produce it, the challenges associated with its use, and the potential applications of this material in biomedicine, regenerative medicine, and drug delivery systems.


  • Open Access

    Preparation and Characterization of Diamond-like Carbon Coatings for Biomedical Applications—A Review

    by Klaudia Malisz, Beata Świeczko-Żurek, Alina Sionkowska

    Diamond-like carbon (DLC) films are generally used in biomedical applications, mainly because of their tribological and chemical properties that prevent the release of substrate ions, extend the life cycle of the material, and promote cell growth. The unique properties of the coating depend on the ratio of the sp3/sp2 phases, where the sp2 phase provides coatings with a low coefficient of friction and good electrical conductivity, while the share of the sp3 phase determines the chemical inertness, high hardness, and resistance to tribological wear. DLC coatings are characterized by high hardness, low coefficient of friction, high corrosion resistance, and biocompatibility. These properties make them attractive as potential wear-resistant coatings in many compelling applications, including optical, mechanical, microelectronic, and biomedical applications. Another great advantage of DLC coatings is that they can be deposited at low temperatures on a variety of substrates and can thus be used to coat heat-sensitive materials, such as polymers. Coating deposition techniques are constantly being improved; techniques based on vacuum environment reactions are mainly used, such as physical vapor deposition (PVD) and chemical vapor deposition (CVD). This review summarizes the current knowledge and research regarding diamond-like carbon coatings.