Min Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Min Hu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Haifeng Dong
Beihang University
2 shared publications - Hangfei Ye
Beihang University
2 shared publications - Chenlu Xu
Beihang University
1 shared publication - Weiming Jiang
School of Instrumentation Science and Opto-Electronics Engineering, Beihang University 1 , Beijing 100191, China
1 shared publication Yuanxing Liu
Beijing Institute of Aerospace Control Devices 2 , Beijing 100094, China
1 shared publication
Latest Publications
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
A compact unshielded optically pumped magnetic gradiometer
Optically pumped magnetic gradiometers (OPG) play a crucial role in applications such as magnetic anomaly detection and biomagnetic measurements. This study classifies current OPG into four types based on their differential modes: voltage, frequency, optical rotation, and magnetic field differential modes. We introduce the concept of inherent common mode rejection ratio (CMRR) and analyze the discrepancy between the inherent CMRR and the measured CMRR, as well as the upper limit of inherent CMRR. We point out that although the magnetic field differential method has the potential to increase the inherent CMRR by a factor of 1 + A(s)F(s), where A(s) and F(s) represent the forward and feedback channel complex gain, respectively, the often-overlooked difference between feedback gains between channels may impose a practical limit on the achievable inherent CMRR. We designed and fabricated a compact, unshielded OPG with a specially designed scheme to minimize the distance between the sensing head and the magnetic source. The measurement results demonstrate gradient sensitivity of 0.36 pT/cm/Hz with a CMRR of 8178@1 Hz in a shielded environment and 5 pT/cm/Hz with a CMRR of 1200@1 Hz in an unshielded environment.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
A compact unshielded optically pumped magnetic gradiometer
Optically pumped magnetic gradiometers (OPG) play a crucial role in applications such as magnetic anomaly detection and biomagnetic measurements. This study classifies current OPG into four types based on their differential modes: voltage, frequency, optical rotation, and magnetic field differential modes. We introduce the concept of inherent common mode rejection ratio (CMRR) and analyze the discrepancy between the inherent CMRR and the measured CMRR, as well as the upper limit of inherent CMRR. We point out that although the magnetic field differential method has the potential to increase the inherent CMRR by a factor of 1 + A(s)F(s), where A(s) and F(s) represent the forward and feedback channel complex gain, respectively, the often-overlooked difference between feedback gains between channels may impose a practical limit on the achievable inherent CMRR. We designed and fabricated a compact, unshielded OPG with a specially designed scheme to minimize the distance between the sensing head and the magnetic source. The measurement results demonstrate gradient sensitivity of 0.36 pT/cm/Hz with a CMRR of 8178@1 Hz in a shielded environment and 5 pT/cm/Hz with a CMRR of 1200@1 Hz in an unshielded environment.
- Open Access
- 25 April 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (16)
Small scale magnetic field source detection using recessed atomic vapor cell
With the development of high spatial resolution spin image and magnetic field distribution measurement in atomic vapor cell, one can localize the position and calculate the magnetic moment of the field source around the cell. However, traditional cubic or spherical vapor cell can only measure the magnetic field distribution on one side of the field source, which limits the precision of the field inversion results. Here, we use a recessed atomic vapor cell to obtain field distribution around the source, which is positioned at the center of the cell. The magnetic field distributions around five sides of the field source are measured using movable stages and digital micro-mirror device. We combine the Levenberg–Marquardt algorithm with a genetic algorithm as the magnetic source localization algorithm to realize a quick global search as well as a precise local extreme point search. We obtain a spatial resolution of 219.2 × 387.0 × 451.5 μ m 3 and a magnetic field sensitivity of 0.06 nT / Hz 1 / 2 in a volume pixel of 0.0383 mm 3. The error in the localization of the magnetic source is 1.295 mm in the x direction, 185 μ m in the y direction, and 40 μ m in the z direction. The field distribution measurement method using recessed atomic vapor cell and related inversion algorithm demonstrated here have great potential applications in small scale field source detection of biology and materials science.
- 25 April 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (16)
Open AccessSmall scale magnetic field source detection using recessed atomic vapor cell
With the development of high spatial resolution spin image and magnetic field distribution measurement in atomic vapor cell, one can localize the position and calculate the magnetic moment of the field source around the cell. However, traditional cubic or spherical vapor cell can only measure the magnetic field distribution on one side of the field source, which limits the precision of the field inversion results. Here, we use a recessed atomic vapor cell to obtain field distribution around the source, which is positioned at the center of the cell. The magnetic field distributions around five sides of the field source are measured using movable stages and digital micro-mirror device. We combine the Levenberg–Marquardt algorithm with a genetic algorithm as the magnetic source localization algorithm to realize a quick global search as well as a precise local extreme point search. We obtain a spatial resolution of 219.2 × 387.0 × 451.5 μ m 3 and a magnetic field sensitivity of 0.06 nT / Hz 1 / 2 in a volume pixel of 0.0383 mm 3. The error in the localization of the magnetic source is 1.295 mm in the x direction, 185 μ m in the y direction, and 40 μ m in the z direction. The field distribution measurement method using recessed atomic vapor cell and related inversion algorithm demonstrated here have great potential applications in small scale field source detection of biology and materials science.