Na Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Na Hu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chuanting Li
Department of Radiology, Shandong Provincial Hospital, Shandong University, Jinan, China
1 shared publication - G. Song
Department of Radiology (G.S.), Shandong Province Qianfoshan Hospital, Jinan, China
1 shared publication - Han Xu
Department of Radiology (H.X., R.G., C.L.)
1 shared publication - Jinye Li
From the Departments of Radiology (J.L., L.S., N.H., T.X., L.W., R.G.)
1 shared publication - L. Li
Medical Service (L.L.), Shandong Provincial ENT Hospital, Shandong University, Jinan, China
1 shared publication - Lei Chen
Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital, Shandong University
1 shared publication
Latest Publications
- Open Access
- 22 September 2026
- Published by Taylor & Francis in Annals of Medicine
- Vol. 58 (1)
Characteristics and prognostic assessment of acute low-frequency sensorineural hearing loss: a retrospective analysis of 546 cases
Acute low-frequency sensorineural hearing loss (ALHL), first defined by Abe in 1982 [1], refers to hearing loss primarily due to low-frequency impairment with preserved medium and high-frequency he...
- 22 September 2026
- Published by Taylor & Francis in Annals of Medicine
- Vol. 58 (1)
Open AccessCharacteristics and prognostic assessment of acute low-frequency sensorineural hearing loss: a retrospective analysis of 546 cases
Acute low-frequency sensorineural hearing loss (ALHL), first defined by Abe in 1982 [1], refers to hearing loss primarily due to low-frequency impairment with preserved medium and high-frequency he...
- Open Access
- 27 April 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (5) , 595-601
A Novel MR Imaging Sequence of 3D-ZOOMit Real Inversion-Recovery Imaging Improves Endolymphatic Hydrops Detection in Patients with Ménière Disease
BACKGROUND AND PURPOSE: The detection rate of premortem MR imaging endolymphatic hydrops is lower than that of postmortem endolymphatic hydrops in Ménière disease, indicating that current MR imaging techniques may underestimate endolymphatic hydrops. Therefore, we prospectively investigated whether a novel high-resolution MR imaging technique, the 3D zoomed imaging technique with parallel transmission real inversion-recovery (3D-ZOOMit real IR), would improve the detection of endolymphatic hydrops compared with conventional 3D TSE inversion-recovery with real reconstruction. MATERIALS AND METHODS: Fifty patients with definite unilateral Ménière disease were enrolled and underwent 3D-ZOOMit real IR and 3D TSE inversion-recovery with real reconstruction 6 hours after IV gadolinium injection. The endo- and perilymph spaces were scored separately. The contrast-to-noise ratio, SNR, and signal intensity ratio of the 2 sequences were respectively calculated and compared. The presence of endolymphatic hydrops was evaluated. RESULTS: The endolymphatic space in the cochlea and vestibule was better visualized with 3D-ZOOMit real IR than with conventional 3D TSE inversion-recovery with real reconstruction (P < .001). There were differences between the 2 sequences in the evaluation of no cochlear hydrops and cochlear hydrops (both, P < .017). All contrast-to-noise ratio, SNR, and signal intensity ratio values of 3D-ZOOMit real IR images were statistically higher than those of conventional 3D TSE inversion-recovery with real reconstruction (all, P < .001). CONCLUSIONS: The 3D-ZOOMit real IR sequences are superior to conventional 3D TSE inversion-recovery with real reconstruction sequences in visualizing the endolymphatic space, detecting endolymphatic hydrops, and discovering contrast permeability.
- 27 April 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (5) , 595-601
Open AccessA Novel MR Imaging Sequence of 3D-ZOOMit Real Inversion-Recovery Imaging Improves Endolymphatic Hydrops Detection in Patients with Ménière Disease
BACKGROUND AND PURPOSE: The detection rate of premortem MR imaging endolymphatic hydrops is lower than that of postmortem endolymphatic hydrops in Ménière disease, indicating that current MR imaging techniques may underestimate endolymphatic hydrops. Therefore, we prospectively investigated whether a novel high-resolution MR imaging technique, the 3D zoomed imaging technique with parallel transmission real inversion-recovery (3D-ZOOMit real IR), would improve the detection of endolymphatic hydrops compared with conventional 3D TSE inversion-recovery with real reconstruction. MATERIALS AND METHODS: Fifty patients with definite unilateral Ménière disease were enrolled and underwent 3D-ZOOMit real IR and 3D TSE inversion-recovery with real reconstruction 6 hours after IV gadolinium injection. The endo- and perilymph spaces were scored separately. The contrast-to-noise ratio, SNR, and signal intensity ratio of the 2 sequences were respectively calculated and compared. The presence of endolymphatic hydrops was evaluated. RESULTS: The endolymphatic space in the cochlea and vestibule was better visualized with 3D-ZOOMit real IR than with conventional 3D TSE inversion-recovery with real reconstruction (P < .001). There were differences between the 2 sequences in the evaluation of no cochlear hydrops and cochlear hydrops (both, P < .017). All contrast-to-noise ratio, SNR, and signal intensity ratio values of 3D-ZOOMit real IR images were statistically higher than those of conventional 3D TSE inversion-recovery with real reconstruction (all, P < .001). CONCLUSIONS: The 3D-ZOOMit real IR sequences are superior to conventional 3D TSE inversion-recovery with real reconstruction sequences in visualizing the endolymphatic space, detecting endolymphatic hydrops, and discovering contrast permeability.