Eckhard Lüpfert
Eckhard Lüpfert has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Benedikt Kölsch
Institute of Solar Research, German Aerospace Center (DLR), Linder Höhe, 51147 Cologne, Germany
3 shared publications - Rafael López-Martín
Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas image/svg+xml
2 shared publications - Sonja Kallio
Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) image/svg+xml
2 shared publications Adrian Schischmanow
1 shared publicationAndré Choinowski
1 shared publication- Anna Chiara Tizzoni
National Agency for New Technologies, Energy and Sustainable Economic Development image/svg+xml
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 4
Molten Salt Technology: A Flexible Outlook for Power-Gas Interconnection
To achieve a climate-neutral energy system, the inherent intermittency of renewable energy sources (RES) must be addressed with advanced storage solutions. Molten salt (MS)-based thermal energy storage (TES) systems are a promising option, distinguished by their high thermal stability, favorable thermophysical properties, and proven scalability in Concentrated Solar Power (CSP) plants. In this paper the authors present the findings of the Joint Research Activity within the EU-funded SALTOpower project, which seeks to advance MS technologies for future integrated energy systems. The research investigates three main areas: the characterization and optimization of MS mixtures; their deployment in Carnot Battery (CB) systems; and their integration into industrial and thermochemical processes for renewable fuel production. Special attention is given to matching MS compositions with specific power cycles (e.g., Rankine and supercritical CO2 Brayton) to maximize system efficiency and reduce levelized costs. Furthermore, the study explores the application of MS-driven heat in Power-to-X (P2X) and Heat-to-X (H2X) pathways, including the production of hydrogen and syngas, thereby enabling crucial cross-sectoral energy integration. By bridging electricity, heat, and fuel domains, MS technologies can act as energy hub integrating electrical, thermal, and chemical energy vectors. Conseguentlythey emerge as a key element for resilient, low-carbon energy infrastructures, in full alignment with the European Union’s strategic objectives for sustainability and energy integration.
- 23 October 2026
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 4
Open AccessMolten Salt Technology: A Flexible Outlook for Power-Gas Interconnection
To achieve a climate-neutral energy system, the inherent intermittency of renewable energy sources (RES) must be addressed with advanced storage solutions. Molten salt (MS)-based thermal energy storage (TES) systems are a promising option, distinguished by their high thermal stability, favorable thermophysical properties, and proven scalability in Concentrated Solar Power (CSP) plants. In this paper the authors present the findings of the Joint Research Activity within the EU-funded SALTOpower project, which seeks to advance MS technologies for future integrated energy systems. The research investigates three main areas: the characterization and optimization of MS mixtures; their deployment in Carnot Battery (CB) systems; and their integration into industrial and thermochemical processes for renewable fuel production. Special attention is given to matching MS compositions with specific power cycles (e.g., Rankine and supercritical CO2 Brayton) to maximize system efficiency and reduce levelized costs. Furthermore, the study explores the application of MS-driven heat in Power-to-X (P2X) and Heat-to-X (H2X) pathways, including the production of hydrogen and syngas, thereby enabling crucial cross-sectoral energy integration. By bridging electricity, heat, and fuel domains, MS technologies can act as energy hub integrating electrical, thermal, and chemical energy vectors. Conseguentlythey emerge as a key element for resilient, low-carbon energy infrastructures, in full alignment with the European Union’s strategic objectives for sustainability and energy integration.
- Open Access
- 16 October 2026
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 4
Condition Monitoring of Flexible Connectors at PTCs
Continuous condition monitoring of critical components in parabolic trough collector (PTC) power plants is crucial for transitioning from traditional reactive maintenance strategies to more efficient predictive maintenance approaches. Predictive maintenance reduces component failures and decreases operation and maintenance costs [1]. The failures and ruptures in flexible pipe connectors PTC can lead to severe consequences, such as leakage and environmental harm [2]. This study focuses on the role of measured forces and torques in enhancing the condition monitoring and maintenance strategies of the flexible pipe connectors. An accelerated life-cycle testing of a set of two connectors until a failure is performed in a test facility. The load cells under the swivel joints are used to measure the forces and torques on the swivel joints. The force analysis was performed and results showed an increase around 5 to 10% in the force amplitude 1000 cycles before the failure. Additionally, the force amplitude increased significantly 200 cycles before the failure. The results proved that the load-based condition monitoring is feasible and effective approach to monitor flexible pipe connectors at PTC.
- 16 October 2026
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 4
Open AccessCondition Monitoring of Flexible Connectors at PTCs
Continuous condition monitoring of critical components in parabolic trough collector (PTC) power plants is crucial for transitioning from traditional reactive maintenance strategies to more efficient predictive maintenance approaches. Predictive maintenance reduces component failures and decreases operation and maintenance costs [1]. The failures and ruptures in flexible pipe connectors PTC can lead to severe consequences, such as leakage and environmental harm [2]. This study focuses on the role of measured forces and torques in enhancing the condition monitoring and maintenance strategies of the flexible pipe connectors. An accelerated life-cycle testing of a set of two connectors until a failure is performed in a test facility. The load cells under the swivel joints are used to measure the forces and torques on the swivel joints. The force analysis was performed and results showed an increase around 5 to 10% in the force amplitude 1000 cycles before the failure. Additionally, the force amplitude increased significantly 200 cycles before the failure. The results proved that the load-based condition monitoring is feasible and effective approach to monitor flexible pipe connectors at PTC.
- Open Access
- 14 July 2026
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 4
Predictive Maintenance of Flexible Pipe Connectors in Parabolic Trough Collectors Using Artificial Neural Networks
In parabolic trough solar power plants, flexible pipe connectors, specifically Rotation and Expansion Performing Assemblies (REPAs), are critical yet failure-prone components due to their exposure to thermal cycling, mechanical stress, and harsh environmental conditions. This study focuses on the Rotary Flex Hose Assembly (RFHA), one common REPA type. Unexpected RFHA malfunctions, such as leaks in swivel joints, can lead to costly downtime and safety hazards. Despite regular preventive maintenance, current strategies often fail to anticipate such failures early enough to prevent disruption. This study investigates whether vibration analysis, combined with machine learning, can provide early warnings of RFHA degradation. A convolutional neural network (CNN) was trained to detect pre-failure conditions using spectrogram comparisons derived from high-frequency vibration data collected during an accelerated life-cycle test campaign. Structural Similarity Index (SSIM) values were used to quantify differences between twin RFHA vibration patterns over time. The model successfully predicted failures up to 1,000 cycles in advance, equivalent to more than two years of lead time in field operation, achieving an overall accuracy of 0.93 and a precision of 1.0, indicating that all predicted failure events were correct and no false positive alarms were generated. These results demonstrate that SSIM-based vibration comparison and CNN classification can provide a robust foundation for predictive maintenance of RFHAs, offering a scalable solution for enhancing the reliability of CSP plant operation.
- 14 July 2026
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 4
Open AccessPredictive Maintenance of Flexible Pipe Connectors in Parabolic Trough Collectors Using Artificial Neural Networks
In parabolic trough solar power plants, flexible pipe connectors, specifically Rotation and Expansion Performing Assemblies (REPAs), are critical yet failure-prone components due to their exposure to thermal cycling, mechanical stress, and harsh environmental conditions. This study focuses on the Rotary Flex Hose Assembly (RFHA), one common REPA type. Unexpected RFHA malfunctions, such as leaks in swivel joints, can lead to costly downtime and safety hazards. Despite regular preventive maintenance, current strategies often fail to anticipate such failures early enough to prevent disruption. This study investigates whether vibration analysis, combined with machine learning, can provide early warnings of RFHA degradation. A convolutional neural network (CNN) was trained to detect pre-failure conditions using spectrogram comparisons derived from high-frequency vibration data collected during an accelerated life-cycle test campaign. Structural Similarity Index (SSIM) values were used to quantify differences between twin RFHA vibration patterns over time. The model successfully predicted failures up to 1,000 cycles in advance, equivalent to more than two years of lead time in field operation, achieving an overall accuracy of 0.93 and a precision of 1.0, indicating that all predicted failure events were correct and no false positive alarms were generated. These results demonstrate that SSIM-based vibration comparison and CNN classification can provide a robust foundation for predictive maintenance of RFHAs, offering a scalable solution for enhancing the reliability of CSP plant operation.
- Open Access
- 28 June 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 95
Application of a combination of innovative non-destructive measurement techniques for structural, energetic and safety analysis of buildings
- 28 June 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 95
Open AccessApplication of a combination of innovative non-destructive measurement techniques for structural, energetic and safety analysis of buildings
- Open Access
- 13 February 2024
- Published by Wiley in Energy Technology
- Vol. 12 (5)
Integrated Concentrating Solar/Photovoltaic Hybrid Concepts—Technological Discussion, Energy Yield, and Cost Considerations
Concentrating solar thermal (CST) technologies are a sustainable way to produce high‐temperature heat. Four concepts of integrating photovoltaics (PV) into CST plants, namely Rear‐PV, PV‐Mirror, bifacial PV‐Mirror and Spillage‐concentrating PV (CPV), are compared and the technological and economic outcome is discussed. The concepts are presented for the use with solar tower systems, but can also be applied to other configurations. In this work, parameters for each concept to quantify annual energy production and investment costs are derived. It is determined that implementing Rear‐PV, PV‐Mirror, bifacial PV‐Mirror, and Spillage‐CPV in a concentrating solar power tower plant leads to an additional energy yield as high as 23%, 29%, 40%, and 36%, respectively, on the same mirror aperture size. For the concepts of the Rear‐PV, PV‐Mirror, and bifacial PV‐Mirror, maximum allowable cost per aperture area can be 3.0, 4.8, and 5.7 times the cost of conventional mirrors, to reach a break‐even of the specific investment cost per annually produced energy. Such values are considered to be achievable for PV‐Mirror and bifacial PV‐Mirror, but not for Rear‐PV. For Spillage‐CPV, a break‐even of investment cost can be achieved if installed in areas with spillage radiation flux exceeding ≈350 kWm−2at peak.
- 13 February 2024
- Published by Wiley in Energy Technology
- Vol. 12 (5)
Open AccessIntegrated Concentrating Solar/Photovoltaic Hybrid Concepts—Technological Discussion, Energy Yield, and Cost Considerations
Concentrating solar thermal (CST) technologies are a sustainable way to produce high‐temperature heat. Four concepts of integrating photovoltaics (PV) into CST plants, namely Rear‐PV, PV‐Mirror, bifacial PV‐Mirror and Spillage‐concentrating PV (CPV), are compared and the technological and economic outcome is discussed. The concepts are presented for the use with solar tower systems, but can also be applied to other configurations. In this work, parameters for each concept to quantify annual energy production and investment costs are derived. It is determined that implementing Rear‐PV, PV‐Mirror, bifacial PV‐Mirror, and Spillage‐CPV in a concentrating solar power tower plant leads to an additional energy yield as high as 23%, 29%, 40%, and 36%, respectively, on the same mirror aperture size. For the concepts of the Rear‐PV, PV‐Mirror, and bifacial PV‐Mirror, maximum allowable cost per aperture area can be 3.0, 4.8, and 5.7 times the cost of conventional mirrors, to reach a break‐even of the specific investment cost per annually produced energy. Such values are considered to be achievable for PV‐Mirror and bifacial PV‐Mirror, but not for Rear‐PV. For Spillage‐CPV, a break‐even of investment cost can be achieved if installed in areas with spillage radiation flux exceeding ≈350 kWm−2at peak.
- 27 April 2023
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 22 (4) , 357-365
Air leakage detection in building façades by combining lock-in thermography with blower excitation
Air leakage in building envelopes is responsible for a large portion of the building’s heating and cooling requirements. Therefore, fast and reliable detection of leaks is crucial for improving energy efficiency. This paper presents a new approach to determining air leakages in a building’s envelope from the outside, combining lock-in thermography and thermal excitation by a blower door system. The blower creates a periodic overpressure within the building, inducing periodic temperature variations of the surfaces near the leaks on the outside surface, the façade. With the temperature variations excited at a known frequency, Fourier transforms of the time-series of the thermal images at the excitation frequency result in amplitude and phase images highlighting the areas affected by leaks. Periodic excitation and detection by an IR camera is known as lock-in thermography and is widely used to characterise semiconductor devices and in non-destructive testing. Excitation is usually achieved by optical, electrical, or mechanical energy input. For this work, measurements of outside façades have been performed with three excitation cycles of a period of 40 s at a 75 Pa pressure difference, leading to a total measurement time of only 2 min. Measurements have been performed with air temperature differences of 5 to 7 K at highly variable conditions of irradiance, wind, and cloud cover. The measurements show higher detection quality and less impact from changing ambient conditions than the state-of-the-art differential infrared thermography measurements. With the method highlighting the variations in the amplitude image only at the excitation frequency, variations caused by environmental effects are filtered out. A temperature difference as low as a few Kelvin is therefore sufficient, and large façades can be examined from the outside. This amplitude image is already clearer than an image created with differential thermography. A further reduction of unwanted artefacts in the image is demonstrated using phase-weighing of the amplitude by scalar product.
- 27 April 2023
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 22 (4) , 357-365
Air leakage detection in building façades by combining lock-in thermography with blower excitation
Air leakage in building envelopes is responsible for a large portion of the building’s heating and cooling requirements. Therefore, fast and reliable detection of leaks is crucial for improving energy efficiency. This paper presents a new approach to determining air leakages in a building’s envelope from the outside, combining lock-in thermography and thermal excitation by a blower door system. The blower creates a periodic overpressure within the building, inducing periodic temperature variations of the surfaces near the leaks on the outside surface, the façade. With the temperature variations excited at a known frequency, Fourier transforms of the time-series of the thermal images at the excitation frequency result in amplitude and phase images highlighting the areas affected by leaks. Periodic excitation and detection by an IR camera is known as lock-in thermography and is widely used to characterise semiconductor devices and in non-destructive testing. Excitation is usually achieved by optical, electrical, or mechanical energy input. For this work, measurements of outside façades have been performed with three excitation cycles of a period of 40 s at a 75 Pa pressure difference, leading to a total measurement time of only 2 min. Measurements have been performed with air temperature differences of 5 to 7 K at highly variable conditions of irradiance, wind, and cloud cover. The measurements show higher detection quality and less impact from changing ambient conditions than the state-of-the-art differential infrared thermography measurements. With the method highlighting the variations in the amplitude image only at the excitation frequency, variations caused by environmental effects are filtered out. A temperature difference as low as a few Kelvin is therefore sufficient, and large façades can be examined from the outside. This amplitude image is already clearer than an image created with differential thermography. A further reduction of unwanted artefacts in the image is demonstrated using phase-weighing of the amplitude by scalar product.