Temel Buyuklimanli
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Temel Buyuklimanli has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Charles W. Magee
Eurofins EAG Laboratories 1 , 104 Windsor Center Drive, Suite 101, East Windsor, New Jersey 08520
2 shared publications - Austin Gregory
Center for Pulsed Power and Power Electronics, Texas Tech University , Lubbock, Texas 79409, USA
1 shared publication - Balaji Raghothamachar
Stony Brook University
1 shared publication - D. Christopher Braddock
Department of Chemistry, Imperial College London, Molecular Sciences Research Hub, White City Campus, 82 Wood Lane, London W12 0BZ, U.K.
1 shared publication Daryl Key
1 shared publicationEdward Letts
1 shared publication
Latest Publications
- Open Access
- 27 August 2024
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 362, 89-96
Characterization of Growth Sectors in Gallium Nitride Substrate Wafers
During crystal growth processes, growth sectors are formed due to growth along different crystallographic directions. Although the crystal structure in the different growth sectors is unchanged, strain induced topography contrast is observed by synchrotron X-ray topography. In this study, synchrotron monochromatic beam X-ray topography (SMBXT), synchrotron X-ray plane wave topography (SXPWT), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and secondary ion mass spectrometry (SIMS) are used to characterize growth sectors in gallium nitride (GaN) substrate wafers grown by patterned hydride vapor phase epitaxy (HVPE). The SMBXT images reveal the boundaries of {0001} and {1122} type growth sectors. Strain maps generated from SXPWT shows that the out-of-plane strains in different growth sectors have a difference of the order of 10-5. SEM images from SE2 signal shows no contrast of growth sector boundaries while images from Robinson detector (RBSD) show different growth sectors as different grey scale contrast, indicating a strain effect. SIMS analysis shows that the different oxygen impurity levels in the growth sectors, which is the origin of the strain. A formation mechanism of growth sectors in patterned HVPE grown GaN wafers is proposed.
- 27 August 2024
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 362, 89-96
Open AccessCharacterization of Growth Sectors in Gallium Nitride Substrate Wafers
During crystal growth processes, growth sectors are formed due to growth along different crystallographic directions. Although the crystal structure in the different growth sectors is unchanged, strain induced topography contrast is observed by synchrotron X-ray topography. In this study, synchrotron monochromatic beam X-ray topography (SMBXT), synchrotron X-ray plane wave topography (SXPWT), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and secondary ion mass spectrometry (SIMS) are used to characterize growth sectors in gallium nitride (GaN) substrate wafers grown by patterned hydride vapor phase epitaxy (HVPE). The SMBXT images reveal the boundaries of {0001} and {1122} type growth sectors. Strain maps generated from SXPWT shows that the out-of-plane strains in different growth sectors have a difference of the order of 10-5. SEM images from SE2 signal shows no contrast of growth sector boundaries while images from Robinson detector (RBSD) show different growth sectors as different grey scale contrast, indicating a strain effect. SIMS analysis shows that the different oxygen impurity levels in the growth sectors, which is the origin of the strain. A formation mechanism of growth sectors in patterned HVPE grown GaN wafers is proposed.
- 22 July 2023
- Published by Elsevier in Journal of Crystal Growth
- Vol. 621
Resistivity of manganese doped GaN grown by near equilibrium ammonothermal (NEAT) method
- 22 July 2023
- Published by Elsevier in Journal of Crystal Growth
- Vol. 621
Resistivity of manganese doped GaN grown by near equilibrium ammonothermal (NEAT) method
- Open Access
- 26 June 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 41 (4)
Erratum: “Secondary ion mass spectrometry quantification: Do you remember when a factor of 2 was good enough?” [J. Vac. Sci. Technol. B 41, 030803 (2023)]
Figure 3 in Ref. 1 has the curve labels in the legend reversed. The correct labeling of the curves is in the figure below. The error is only in this figure, and
- 26 June 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 41 (4)
Open AccessErratum: “Secondary ion mass spectrometry quantification: Do you remember when a factor of 2 was good enough?” [J. Vac. Sci. Technol. B 41, 030803 (2023)]
Figure 3 in Ref. 1 has the curve labels in the legend reversed. The correct labeling of the curves is in the figure below. The error is only in this figure, and
- Open Access
- 20 April 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 41 (3)
Secondary ion mass spectrometry quantification: Do you remember when a factor of 2 was good enough?
Well, do you remember when a factor of 2 was good enough? Probably, not unless you have been around secondary ion mass spectrometry (SIMS) since the early 1960s, like one of us has been. This paper will give many references back to the early days of quantification when a local thermal equilibrium model was used to obtain the first results that were accurate to within a factor of 2, but only 60% of the time. It only worked for bulk silicate matrixes. People were not even using SIMS on semiconductors in those days. Several early references showing profiles of ion implants in Si will be referenced, but it was not until 1980 that the first paper was published that explicitly showed how to use ion implants as SIMS standards. People were using ion implants as standards before 1980, but only in limited cases, and with no formal published equations specifying how to use them. But, the samples for which ion implants were used as standards were for dilute concentrations in a single matrix, which had a uniform matrix composition with depth. The rest of the paper will show how we at Eurofins EAG Laboratories tackled the problem of quantification of both major and minor elements in nonuniform, multi-element matrices with continuously graded composition changes using point-by-point CORrected-SIMS. These include SiGe heterostructure bipolar transistors, AlGaAs vertical cavity surface emitting lasers, and B plasma-implanted poly-silicon gates.
- 20 April 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 41 (3)
Open AccessSecondary ion mass spectrometry quantification: Do you remember when a factor of 2 was good enough?
Well, do you remember when a factor of 2 was good enough? Probably, not unless you have been around secondary ion mass spectrometry (SIMS) since the early 1960s, like one of us has been. This paper will give many references back to the early days of quantification when a local thermal equilibrium model was used to obtain the first results that were accurate to within a factor of 2, but only 60% of the time. It only worked for bulk silicate matrixes. People were not even using SIMS on semiconductors in those days. Several early references showing profiles of ion implants in Si will be referenced, but it was not until 1980 that the first paper was published that explicitly showed how to use ion implants as SIMS standards. People were using ion implants as standards before 1980, but only in limited cases, and with no formal published equations specifying how to use them. But, the samples for which ion implants were used as standards were for dilute concentrations in a single matrix, which had a uniform matrix composition with depth. The rest of the paper will show how we at Eurofins EAG Laboratories tackled the problem of quantification of both major and minor elements in nonuniform, multi-element matrices with continuously graded composition changes using point-by-point CORrected-SIMS. These include SiGe heterostructure bipolar transistors, AlGaAs vertical cavity surface emitting lasers, and B plasma-implanted poly-silicon gates.
- 3 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 29 (11) , 1181-1183
Screening of Oxide/GaAs Interfaces for MOSFET Applications
Photoluminescence intensity (PL-I) data are presented for 22 dielectric/GaAs systems investigated for MOSFET applications. The PL-I technique has been identified as a most useful and reliable tool for screening dielectric/GaAs interfaces and has been instrumental in the identification of a device quality dielectric/GaAs interface: in situ deposited Ga2O3 on GaAs. The early discovery of such an interface has allowed us to focus resources and to succeed to manufacture GaAs MOSFETs which perform in line with theoretical model predictions after more than 40 years of failed attempts. It is strongly recommended to extend the technique to the investigation of CMOS relevant channel materials such as InGaAs.
- 3 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 29 (11) , 1181-1183
Screening of Oxide/GaAs Interfaces for MOSFET Applications
Photoluminescence intensity (PL-I) data are presented for 22 dielectric/GaAs systems investigated for MOSFET applications. The PL-I technique has been identified as a most useful and reliable tool for screening dielectric/GaAs interfaces and has been instrumental in the identification of a device quality dielectric/GaAs interface: in situ deposited Ga2O3 on GaAs. The early discovery of such an interface has allowed us to focus resources and to succeed to manufacture GaAs MOSFETs which perform in line with theoretical model predictions after more than 40 years of failed attempts. It is strongly recommended to extend the technique to the investigation of CMOS relevant channel materials such as InGaAs.
- 7 August 2001
- Published by American Physical Society (APS) in Physical Review B
- Vol. 64 (8) , 085316
Quantitative measurement of the surface silicon interstitial boundary condition and silicon interstitial injection into silicon during oxidation
During the oxidation of silicon, interstitials are generated at the oxidizing surface and diffuse into the silicon. Boron diffusion was used to map the local interstitial supersaturation, the ratio of interstitial concentration to the equilibrium concentration of interstitials versus the distance above buried layers during oxidation. The average interstitial supersaturation at the silicon surface, extrapolated from the depth profiles was ∼25 and ∼13 for 750 °C and 850 °C, respectively. Using the measured interstitial concentration at the surface, the silicon interstitial injection into the silicon is calculated for oxidation at 750 °C and 850 °C. Finally, it is found that the surface boundary condition remains relatively fixed for an interstitial injection rate ranging over four orders of magnitude.- 7 August 2001
- Published by American Physical Society (APS) in Physical Review B
- Vol. 64 (8) , 085316
Quantitative measurement of the surface silicon interstitial boundary condition and silicon interstitial injection into silicon during oxidation
During the oxidation of silicon, interstitials are generated at the oxidizing surface and diffuse into the silicon. Boron diffusion was used to map the local interstitial supersaturation, the ratio of interstitial concentration to the equilibrium concentration of interstitials versus the distance above buried layers during oxidation. The average interstitial supersaturation at the silicon surface, extrapolated from the depth profiles was ∼25 and ∼13 for 750 °C and 850 °C, respectively. Using the measured interstitial concentration at the surface, the silicon interstitial injection into the silicon is calculated for oxidation at 750 °C and 850 °C. Finally, it is found that the surface boundary condition remains relatively fixed for an interstitial injection rate ranging over four orders of magnitude.