William B. Salloom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William B. Salloom has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Elizabeth A. Strickland
Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, USA
3 shared publications - Hari M. Bharadwaj
Department of Communication Science and Disorders, University of Pittsburgh, Pittsburgh, PA, USA
3 shared publications Elizabeth A. Strickland
Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
1 shared publicationHari Bharadwaj
Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
1 shared publicationKristen Wade
Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
1 shared publication
Latest Publications
- Open Access
- 25 November 2025
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 26 (6) , 671-697
The Effects of Broadband Elicitor Duration on Transient-Evoked Otoacoustic Emissions and a Psychoacoustic Measure of Gain Reduction
Purpose: Measures of the human medial olivocochlear reflex (MOCR) typically rely on long duration (> 100 ms) or continuously presented broadband elicitors. MOCR gain reduction measured by otoacoustic emissions (OAE) exhibits multiple time constants, including in the hundreds of milliseconds, when elicited by broadband noise. Psychoacoustic studies of gain reduction have largely adopted these elicitor characteristics, but less is known about how broadband elicitor duration affects auditory perception. Additionally, the literature on the relationship between psychoacoustic and OAE measures of gain reduction has yielded mixed results, which is counterintuitive if both measures reflect the same mechanism. In this study, the effects of ipsilateral broadband elicitor duration were evaluated using forward masking psychoacoustic and transient-evoked OAE (TEOAE) paradigms in individuals with normal hearing (N = 19; m = 7, f = 12). Methods: Ipsilateral pink broadband noise was used as the elicitor in both experiments, presented at 50 dB SPL (50–800 ms) for the psychoacoustic measures and 50 dB FPL (50–400 ms) for the TEOAE measures. Gain reduction was quantified as the change in signal threshold (2 kHz) and the change in TEOAE level (1/3rd-octave band centered at 2 kHz) with and without the presence of the elicitor. Results: The average time constants for psychoacoustic and TEOAE gain reduction were similarly short (< 100 ms), with near-maximal effects observed for elicitor durations of 200 ms. However, individual comparisons of TEOAE and psychoacoustic gain reduction revealed mixed results. Potential factors contributing to this discrepancy are discussed. Conclusion: The human MOCR reduces cochlear gain on relatively short time scales (< 100 ms) with ipsilateral broadband elicitors.
- 25 November 2025
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 26 (6) , 671-697
Open AccessThe Effects of Broadband Elicitor Duration on Transient-Evoked Otoacoustic Emissions and a Psychoacoustic Measure of Gain Reduction
Purpose: Measures of the human medial olivocochlear reflex (MOCR) typically rely on long duration (> 100 ms) or continuously presented broadband elicitors. MOCR gain reduction measured by otoacoustic emissions (OAE) exhibits multiple time constants, including in the hundreds of milliseconds, when elicited by broadband noise. Psychoacoustic studies of gain reduction have largely adopted these elicitor characteristics, but less is known about how broadband elicitor duration affects auditory perception. Additionally, the literature on the relationship between psychoacoustic and OAE measures of gain reduction has yielded mixed results, which is counterintuitive if both measures reflect the same mechanism. In this study, the effects of ipsilateral broadband elicitor duration were evaluated using forward masking psychoacoustic and transient-evoked OAE (TEOAE) paradigms in individuals with normal hearing (N = 19; m = 7, f = 12). Methods: Ipsilateral pink broadband noise was used as the elicitor in both experiments, presented at 50 dB SPL (50–800 ms) for the psychoacoustic measures and 50 dB FPL (50–400 ms) for the TEOAE measures. Gain reduction was quantified as the change in signal threshold (2 kHz) and the change in TEOAE level (1/3rd-octave band centered at 2 kHz) with and without the presence of the elicitor. Results: The average time constants for psychoacoustic and TEOAE gain reduction were similarly short (< 100 ms), with near-maximal effects observed for elicitor durations of 200 ms. However, individual comparisons of TEOAE and psychoacoustic gain reduction revealed mixed results. Potential factors contributing to this discrepancy are discussed. Conclusion: The human MOCR reduces cochlear gain on relatively short time scales (< 100 ms) with ipsilateral broadband elicitors.
- Open Access
- 12 August 2025
- Published by Springer Nature in Research Square
The effects of broadband elicitor duration on transient-evoked otoacoustic emissions and a psychoacoustic measure of gain reduction
Purpose: Measures of the human medial olivocochlear reflex (MOCR) typically rely on long duration (>100 ms) or continuously presented broadband elicitors. MOCR gain reduction measured by otoacoustic emissions (OAE) exhibits multiple time constants, including in the hundreds of milliseconds, when elicited by broadband noise. Psychoacoustic studies of gain reduction have largely adopted these elicitor characteristics, but less is known about how broadband elicitor duration affects auditory perception. Additionally, the literature on the relationship between psychoacoustic and OAE measures of gain reduction has yielded mixed results, which is counterintuitive if both measures reflect the same mechanism. In this study, the effects of ipsilateral broadband elicitor duration were evaluated using forward masking psychoacoustic and transient-evoked OAE (TEOAE) paradigms in individuals with normal hearing (N = 19; m = 7, f = 12). Methods: Ipsilateral pink broadband noise was used as the elicitor in both experiments, presented at 50 dB SPL (50-800 ms) for the psychoacoustic measures and 50 dB FPL (50-400 ms) for the TEOAE measures. Gain reduction was quantified as the change in signal threshold (2 kHz) and the change in TEOAE level (1/3rd-octave band centered at 2 kHz) with and without the presence of the elicitor. Results: The average time constants for psychoacoustic and TEOAE gain reduction were similarly short (<100 ms), with near-maximal effects observed for elicitor durations of 200 ms. However, individual comparisons of TEOAE and psychoacoustic gain reduction revealed mixed results. Potential factors contributing to this discrepancy are discussed. Conclusion: The human MOCR reduces cochlear gain on relatively short time scales (<100 ms) with ipsilateral broadband elicitors.
- 12 August 2025
- Published by Springer Nature in Research Square
Open AccessThe effects of broadband elicitor duration on transient-evoked otoacoustic emissions and a psychoacoustic measure of gain reduction
Purpose: Measures of the human medial olivocochlear reflex (MOCR) typically rely on long duration (>100 ms) or continuously presented broadband elicitors. MOCR gain reduction measured by otoacoustic emissions (OAE) exhibits multiple time constants, including in the hundreds of milliseconds, when elicited by broadband noise. Psychoacoustic studies of gain reduction have largely adopted these elicitor characteristics, but less is known about how broadband elicitor duration affects auditory perception. Additionally, the literature on the relationship between psychoacoustic and OAE measures of gain reduction has yielded mixed results, which is counterintuitive if both measures reflect the same mechanism. In this study, the effects of ipsilateral broadband elicitor duration were evaluated using forward masking psychoacoustic and transient-evoked OAE (TEOAE) paradigms in individuals with normal hearing (N = 19; m = 7, f = 12). Methods: Ipsilateral pink broadband noise was used as the elicitor in both experiments, presented at 50 dB SPL (50-800 ms) for the psychoacoustic measures and 50 dB FPL (50-400 ms) for the TEOAE measures. Gain reduction was quantified as the change in signal threshold (2 kHz) and the change in TEOAE level (1/3rd-octave band centered at 2 kHz) with and without the presence of the elicitor. Results: The average time constants for psychoacoustic and TEOAE gain reduction were similarly short (<100 ms), with near-maximal effects observed for elicitor durations of 200 ms. However, individual comparisons of TEOAE and psychoacoustic gain reduction revealed mixed results. Potential factors contributing to this discrepancy are discussed. Conclusion: The human MOCR reduces cochlear gain on relatively short time scales (<100 ms) with ipsilateral broadband elicitors.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3062 (1)
The effect of broadband elicitor duration on transient-evoked otoacoustic emissions and a psychoacoustic measure of gain reduction
Physiological and psychoacoustic studies of the medial olivocochlear reflex (MOCR) in humans have often relied on long elicitors (> 100-ms). This is largely
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3062 (1)
The effect of broadband elicitor duration on transient-evoked otoacoustic emissions and a psychoacoustic measure of gain reduction
Physiological and psychoacoustic studies of the medial olivocochlear reflex (MOCR) in humans have often relied on long elicitors (> 100-ms). This is largely
- Open Access
- 1 April 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (4) , 2482
The effects of broadband elicitor duration on a psychoacoustic measure of cochlear gain reduction
Physiological and psychoacoustic studies of the medial olivocochlear reflex (MOCR) in humans have often relied on long duration elicitors (>100 ms). This is largely due to previous research using otoacoustic emissions (OAEs) that found multiple MOCR time constants, including time constants in the 100s of milliseconds, when elicited by broadband noise. However, the effect of the duration of a broadband noise elicitor on similar psychoacoustic tasks is currently unknown. The current study measured the effects of ipsilateral broadband noise elicitor duration on psychoacoustic gain reduction estimated from a forward-masking paradigm. Analysis showed that both masker type and elicitor duration were significant main effects, but no interaction was found. Gain reduction time constants were ∼46 ms for the masker present condition and ∼78 ms for the masker absent condition (ranging from ∼29 to 172 ms), both similar to the fast time constants reported in the OAE literature (70–100 ms). Maximum gain reduction was seen for elicitor durations of ∼200 ms. This is longer than the 50-ms duration which was found to produce maximum gain reduction with a tonal on-frequency elicitor. Future studies of gain reduction may use 150–200 ms broadband elicitors to maximally or near-maximally stimulate the MOCR.
- 1 April 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (4) , 2482
Open AccessThe effects of broadband elicitor duration on a psychoacoustic measure of cochlear gain reduction
Physiological and psychoacoustic studies of the medial olivocochlear reflex (MOCR) in humans have often relied on long duration elicitors (>100 ms). This is largely due to previous research using otoacoustic emissions (OAEs) that found multiple MOCR time constants, including time constants in the 100s of milliseconds, when elicited by broadband noise. However, the effect of the duration of a broadband noise elicitor on similar psychoacoustic tasks is currently unknown. The current study measured the effects of ipsilateral broadband noise elicitor duration on psychoacoustic gain reduction estimated from a forward-masking paradigm. Analysis showed that both masker type and elicitor duration were significant main effects, but no interaction was found. Gain reduction time constants were ∼46 ms for the masker present condition and ∼78 ms for the masker absent condition (ranging from ∼29 to 172 ms), both similar to the fast time constants reported in the OAE literature (70–100 ms). Maximum gain reduction was seen for elicitor durations of ∼200 ms. This is longer than the 50-ms duration which was found to produce maximum gain reduction with a tonal on-frequency elicitor. Future studies of gain reduction may use 150–200 ms broadband elicitors to maximally or near-maximally stimulate the MOCR.