MHMaximilian J. Huber

Maximilian J. Huber

*This is an algorithmically generated author record based on publicly available information.

Maximilian J. Huber has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Online Coupling of Field-Flow Fractionation with Raman Microspectroscopy Enables the Advanced Study of Nanoplastics Directly in Food

    by Stefano Giordani, Maximilian J. Huber, Isabel S. Jüngling, Andrea Zattoni, Barbara Roda, Pierluigi Reschiglian, Valentina Marassi, Natalia P. Ivleva

    The detection and understanding of the behavior of nanoplastics (NPLs) in complex (in)organic systems is a growing concern and one of the major challenges in analytical chemistry today. Current analytical methods are limited in terms of sample flexibility and automation, often require laborious pretreatment, and usually only provide limited information about the presence of NPLs without assessing the behavior of the plastics in the matrix. Coupling an asymmetrical flow field-flow fractionation multidetector (AF4-MD) platform with Raman microspectroscopy (RM) represents a significant advancement in the field, offering a novel approach that combines the advantages of a highly flexible, automatable, and informative analytical system (AF4-MD) with a detector able to chemically identify NPLs (RM). Up to now, this pioneering technique has only been used to study different nanoparticles in an aqueous environment. Here, for the first time, we report the application of an AF4-MD-RM platform to detect NPLs in a real unprocessed matrix. The developed approach allowed for the separation, selective detection, and multiparametric characterization of milk components and NPLs (polystyrene, PS beads, 100-500 nm) in a short analytical time without sample pretreatment, while providing PS detection threshold values compatible with those of the currently exploited quantification approaches. These beyond the state-of-the-art results were proved with orthogonal techniques and highlight the game-changing potential of AF4-MD-RM for a straightforward detection of NPLs in complex matrices and the characterization of NPL-matrix interactions.


  • Open Access

    Studying the degradation of bulk PTFE into microparticles via SP ICP-MS: a systematically developed method for the detection of F-containing particles

    by Raquel Gonzalez de Vega, Thebny Thaíse Moro, Bernhard Grüner, Tatiane de Andrade Maranhão, Maximilian J. Huber, Natalia P. Ivleva, Etienne Skrzypek, Jörg Feldmann, David Clases

    Investigating the degradation of PTFE in seawater after UV radiation by SP ICP-MS via F and C analysis.


  • Open Access

    Multi-Parameter Analysis of Nanoplastics in Flow: Taking Advantage of High Sensitivity and Time Resolution Enabled by Stimulated Raman Scattering

    by Maximilian J. Huber, Liron Zada, Natalia P. Ivleva, Freek Ariese

    Here, we demonstrate the detection of nanoplastics (NPLs) in flow with stimulated Raman scattering (SRS) for the first time. NPLs (plastic particles <1000 nm) have recently been detected in different environmental samples and personal care products. However, their characterization is still an analytical challenge. Multiple parameters, including size, chemical composition, and concentration (particle number and mass), need to be determined. In an earlier paper, online field flow fractionation (FFF)-Raman analysis with optical trapping was shown to be a promising tool for the detection of particles in this size range. SRS, which is based on the enhancement of a vibrational transition by the matching energy difference of two laser beams, would allow for much more sensitive detection and, hence, much shorter acquisition times compared to spontaneous Raman microspectroscopy (RM). Here, we show the applicability of SRS for the flow-based analysis of individual, untrapped NPLs. It was possible to detect polyethylene (PE), polystyrene (PS), and poly(methyl methacrylate) (PMMA) beads with diameters of 100-5000 nm. The high time resolution of 60.5 mu s allows us to detect individual signals per particle and to correlate the number of detected particles to the injected mass concentration. Furthermore, due to the high time resolution, optically trapped beads could be distinguished from untrapped beads by their peak shapes. The SRS wavenumber settings add chemical selectivity to the measurement. Whereas optical trapping is necessary for the flow-based detection of particles by spontaneous RM, the current study demonstrates that SRS can detect particles in a flow without trapping. Additionally, the mean particle size could be estimated using the mean width (duration) and intensity of the SRS signals.


  • Open Access

    Studying the degradation of bulk PTFE into microparticles via SP ICP-MS: A systematically developed method for the detection of F-containing particles

    by Raquel Gonzalez de Vega, Thebny Thaíse Moro, Bernhard Grüner, Tatiane de Andrade Maranhão, Maximilian Huber, Natalia Ivleva, Etienne Skrzypek, Jörg Feldmann, David Clases

    Fluoropolymers, such as polytetrafluoroethylene (PTFE), have unique properties, which enable versatile applications in industry and make them useful for various consumer products. However, it is known that these polymers degrade over time and form small particles with possible implications for environment and health. Building on previous reports for the detection of Fluorine (F) via inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) using a Barium-based modifier, this study presents a design of experiments approach (DoE), which optimised plasma parameters, ion optics, mass filtering and collision/reaction cell conditions systematically. The resulting method was capable to detect micro-scaled PTFE particles and to determine number concentrations as well as size distributions. Validation was carried out in two steps: First, micro-scaled PTFE standards were characterised via microscopy and Raman spectroscopy and second, carbon-selective single particle (SP) ICP-MS was employed to corroborate results obtained via the F-selective method. The developed method has a high utility to characterise the degradation of bulk PTFE into microplastics, which was demonstrated in an environmentally focussed proof-of-concept study. Here, bulk PTFE material was stirred in simulated seawater under UV-light illumination for 6 days. After this incubation period a microplastic number concentration of 2.35 x 105 F-based particles per gram immersed bulk PTFE was detected. PTFE particles had a mean mass and size of 28 pg and 2.7 µm, respectively.

  • Top Cited Papers
    Open Access

    Physicochemical characterization and quantification of nanoplastics: applicability, limitations and complementarity of batch and fractionation methods

    by Maximilian J. Huber, Natalia P. Ivleva, Andy M. Booth, Irina Beer, Ivana Bianchi, Roland Drexel, Otmar Geiss, Dora Mehn, Florian Meier, Alicja Molska, et al.

    A comprehensive physicochemical characterization of heterogeneous nanoplastic (NPL) samples remains an analytical challenge requiring a combination of orthogonal measurement techniques to improve the accuracy and robustness of the results. Here, batch methods, including dynamic light scattering (DLS), nanoparticle tracking analysis (NTA), tunable resistive pulse sensing (TRPS), transmission electron microscopy (TEM), and scanning electron microscopy (SEM), as well as separation/fractionation methods such as centrifugal liquid sedimentation (CLS) and field-flow fractionation (FFF)–multi-angle light scattering (MALS) combined with pyrolysis gas chromatography mass spectrometry (pyGC–MS) or Raman microspectroscopy (RM) were evaluated for NPL size, shape, and chemical composition measurements and for quantification. A set of representative/test particles of different chemical natures, including (i) polydisperse polyethylene (PE), (ii) (doped) polystyrene (PS) NPLs, (iii) titanium dioxide, and (iv) iron oxide nanoparticles (spherical and elongated), was used to assess the applicability and limitations of the selected methodologies. Particle sizes and number-based concentrations obtained by orthogonal batch methods (DLS, NTA, TRPS) were comparable for monodisperse spherical samples, while higher deviations were observed for polydisperse, agglomerated samples and for non-spherical particles, especially for light scattering methods. CLS and TRPS offer further insight with increased size resolution, while detailed morphological information can be derived by electron microscopy (EM)–based approaches. Combined techniques such as FFF coupled to MALS and RM can provide complementary information on physical and chemical properties by online measurements, while pyGC–MS analysis of FFF fractions can be used for the identification of polymer particles (vs. inorganic particles) and for their offline (semi)quantification. However, NPL analysis in complex samples will continue to present a serious challenge for the evaluated techniques without significant improvements in sample preparation. Graphical abstract