David Q. Le
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Q. Le has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Alan Gatrell
Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Durham, North Carolina, United States of America
2 shared publications- Andrew H. Hoang
School of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA, USA; Center for Image-Guided Neurosurgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA; Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
2 shared publications - Arian Azarang
Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, USA
2 shared publications - Frauke Tillmans
Divers Alert Network
2 shared publications - Rachel M. Lance
Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Durham, North Carolina, United States of America
2 shared publications - Virginie Papadopoulou
Department of Radiology, The University of North Carolina at Chapel Hill, NC, USA
2 shared publications
Latest Publications
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (7) , 879-888
Microvascular Ultrasound Imaging in the Neonatal Brain: From Advanced Doppler to Super-Resolution
In imaging the neonatal brain, overcoming the diffraction limit to conventional ultrasound is required to achieve images of sufficient spatial resolution. Super-resolution imaging uses ultrasound localization microscopy to image inert microbubble contrast at high frame rates, allowing exquisite detail and flow information on intracranial vessels. However, this is a mainly research-based modality. In contrast, advanced Doppler techniques, which do not require contrast, offer flow imaging far better than that of conventional Doppler, and are readily available in the clinical setting. We discuss the pros and cons of both modalities, and the promising applications of both in the clinical setting with a series of case-examples.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (7) , 879-888
Microvascular Ultrasound Imaging in the Neonatal Brain: From Advanced Doppler to Super-Resolution
In imaging the neonatal brain, overcoming the diffraction limit to conventional ultrasound is required to achieve images of sufficient spatial resolution. Super-resolution imaging uses ultrasound localization microscopy to image inert microbubble contrast at high frame rates, allowing exquisite detail and flow information on intracranial vessels. However, this is a mainly research-based modality. In contrast, advanced Doppler techniques, which do not require contrast, offer flow imaging far better than that of conventional Doppler, and are readily available in the clinical setting. We discuss the pros and cons of both modalities, and the promising applications of both in the clinical setting with a series of case-examples.
- Open Access
- 27 April 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (4) , e0284922
An open-source framework for synthetic post-dive Doppler ultrasound audio generation
Doppler ultrasound (DU) measurements are used to detect and evaluate venous gas emboli (VGE) formed after decompression. Automated methodologies for assessing VGE presence using signal processing have been developed on varying real-world datasets of limited size and without ground truth values preventing objective evaluation. We develop and report a method to generate synthetic post-dive data using DU signals collected in both precordium and subclavian vein with varying degrees of bubbling matching field-standard grading metrics. This method is adaptable, modifiable, and reproducible, allowing for researchers to tune the produced dataset for their desired purpose. We provide the baseline Doppler recordings and code required to generate synthetic data for researchers to reproduce our work and improve upon it. We also provide a set of pre-made synthetic post-dive DU data spanning six scenarios representing the Spencer and Kisman-Masurel (KM) grading scales as well as precordial and subclavian DU recordings. By providing a method for synthetic post-dive DU data generation, we aim to improve and accelerate the development of signal processing techniques for VGE analysis in Doppler ultrasound.
- 27 April 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (4) , e0284922
Open AccessAn open-source framework for synthetic post-dive Doppler ultrasound audio generation
Doppler ultrasound (DU) measurements are used to detect and evaluate venous gas emboli (VGE) formed after decompression. Automated methodologies for assessing VGE presence using signal processing have been developed on varying real-world datasets of limited size and without ground truth values preventing objective evaluation. We develop and report a method to generate synthetic post-dive data using DU signals collected in both precordium and subclavian vein with varying degrees of bubbling matching field-standard grading metrics. This method is adaptable, modifiable, and reproducible, allowing for researchers to tune the produced dataset for their desired purpose. We provide the baseline Doppler recordings and code required to generate synthetic data for researchers to reproduce our work and improve upon it. We also provide a set of pre-made synthetic post-dive DU data spanning six scenarios representing the Spencer and Kisman-Masurel (KM) grading scales as well as precordial and subclavian DU recordings. By providing a method for synthetic post-dive DU data generation, we aim to improve and accelerate the development of signal processing techniques for VGE analysis in Doppler ultrasound.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (5) , 1436-1446
Deep Learning-Based Venous Gas Emboli Grade Classification in Doppler Ultrasound Audio Recordings
Objective: Doppler ultrasound (DU) is used to detect venous gas emboli (VGE) post dive as a marker of decompression stress for diving physiology research as well as new decompression procedure validation to minimize decompression sickness risk. In this paper, we propose the first deep learning model for VGE grading in DU audio recordings. Methods: A database of real-world data was assembled and labeled for the purpose of developing the algorithm, totaling 274 recordings comprising both subclavian and precordial measurements. Synthetic data was also generated by acquiring baseline DU signals from human volunteers and superimposing laboratory-acquired DU signals of bubbles flowing in a tissue mimicking material. A novel squeeze-and-excitation deep learning model was designed to effectively classify recordings on the 5-class Spencer scoring system used by trained human raters. Results: On the real-data test set, we show that synthetic data pretraining achieves average ordinal accuracy of 84.9% for precordial and 90.4% for subclavian DU which is a 24.6% and 26.2% increase over training with real-data and time-series augmentation only. The weighted kappa coefficients of agreement between the model and human ground truth were 0.74 and 0.69 for precordial and subclavian respectively, indicating substantial agreement similar to human inter-rater agreement for this type of data. Conclusion: The present work demonstrates the first application of deep-learning for DU VGE grading using a combination of synthetic and real-world data. Significance: The proposed method can contribute to accelerating DU analysis for decompression research.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (5) , 1436-1446
Deep Learning-Based Venous Gas Emboli Grade Classification in Doppler Ultrasound Audio Recordings
Objective: Doppler ultrasound (DU) is used to detect venous gas emboli (VGE) post dive as a marker of decompression stress for diving physiology research as well as new decompression procedure validation to minimize decompression sickness risk. In this paper, we propose the first deep learning model for VGE grading in DU audio recordings. Methods: A database of real-world data was assembled and labeled for the purpose of developing the algorithm, totaling 274 recordings comprising both subclavian and precordial measurements. Synthetic data was also generated by acquiring baseline DU signals from human volunteers and superimposing laboratory-acquired DU signals of bubbles flowing in a tissue mimicking material. A novel squeeze-and-excitation deep learning model was designed to effectively classify recordings on the 5-class Spencer scoring system used by trained human raters. Results: On the real-data test set, we show that synthetic data pretraining achieves average ordinal accuracy of 84.9% for precordial and 90.4% for subclavian DU which is a 24.6% and 26.2% increase over training with real-data and time-series augmentation only. The weighted kappa coefficients of agreement between the model and human ground truth were 0.74 and 0.69 for precordial and subclavian respectively, indicating substantial agreement similar to human inter-rater agreement for this type of data. Conclusion: The present work demonstrates the first application of deep-learning for DU VGE grading using a combination of synthetic and real-world data. Significance: The proposed method can contribute to accelerating DU analysis for decompression research.