D. V. Ten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
D. V. Ten has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandr V. Mitronin
Russian University of Medicine
1 shared publication - Andrey Sannikov
National University of Science and Technology “MISIS
1 shared publication - Andrey V. Koltygin
Casting Department, National University of Science and Technology “MISiS”, Leninskiy pr. 4, 119049 Moscow, Russia
1 shared publication - D. A. Ostanina
Russian University of Medicine
1 shared publication - D. S. Rozhkova
National University of Science and Technology “MISIS
1 shared publication - E. A. Lazarev
PJSC «UEC-Kuznetsov
1 shared publication
Latest Publications
- Open Access
- 5 October 2026
- Published by Khabadze ZS in Эндодонтия Today
Experimental rationale for the selection of rotary NiTi instruments for mechanical preparation of calcified root canals
INTRODUCTION. Mechanical preparation of calcified and partially obliterated root canals is associated with an increased risk of locking and fracture of rotary NiTi instruments. The resistance of NiTi instruments to mechanical loading is determined by the combined influence of the NiTi alloy type and the geometric features of the working part. PURPOSE. To provide an experimental rationale for the selection criteria of rotary NiTi instruments for mechanical preparation of calcified root canals based on a comparative laboratory assessment of torsional resistance and the design parameters of the working part of rotary file systems. MATERIALS AND METHODS. The study comprised two stages. At the first stage, torsional testing was performed on 45 instruments divided into three groups of 15 specimens each: E-Flex Path Blue instruments manufactured from thermally treated Blue NiTi alloy (group IA), PathFile instruments manufactured from conventional NiTi alloy (group IB), and E-Flex Path Gold instruments manufactured from thermally treated Gold NiTi alloy (group IC). Maximum torque and angle of rotation at fracture were determined. At the second stage, scanning electron microscopy and morphometric analysis were used to evaluate the apical portion of the working part, cross-sectional geometry, and the inner-to-outer diameter ratio ( K D ) of the PathFile (group IIA), SoCo Plus (group IIB), and Scout RaCe (group IIC) instrument systems at the D 0 and D 3 levels. RESULTS. The maximum torque of the group IB specimens was 2.50±0.12 N⋅cm and was 2.08 and 2.45 times higher than the corresponding values in groups IC and IA, respectively. The greatest angle of rotation at fracture was recorded for the group IA instruments (540±45°), followed by group IC (455±40°), whereas the lowest value was observed in group IB (390±35°; p < 0.001). The instruments differed in the geometry of the apical working part and cross-sectional shape. The highest K D values were recorded for the group IIB specimens: 0.51 at the D 0 level and 0.74 at the D 3 level. CONCLUSIONS. The findings support the use of maximum torque, angle of rotation at fracture, and the geometric characteristics of the apical portion as criteria for the differentiated selection of rotary NiTi instruments for the preparation of calcified root canals, taking into account the risk of torsional locking and the characteristics of the mineralized obstruction.
- 5 October 2026
- Published by Khabadze ZS in Эндодонтия Today
Open AccessExperimental rationale for the selection of rotary NiTi instruments for mechanical preparation of calcified root canals
INTRODUCTION. Mechanical preparation of calcified and partially obliterated root canals is associated with an increased risk of locking and fracture of rotary NiTi instruments. The resistance of NiTi instruments to mechanical loading is determined by the combined influence of the NiTi alloy type and the geometric features of the working part. PURPOSE. To provide an experimental rationale for the selection criteria of rotary NiTi instruments for mechanical preparation of calcified root canals based on a comparative laboratory assessment of torsional resistance and the design parameters of the working part of rotary file systems. MATERIALS AND METHODS. The study comprised two stages. At the first stage, torsional testing was performed on 45 instruments divided into three groups of 15 specimens each: E-Flex Path Blue instruments manufactured from thermally treated Blue NiTi alloy (group IA), PathFile instruments manufactured from conventional NiTi alloy (group IB), and E-Flex Path Gold instruments manufactured from thermally treated Gold NiTi alloy (group IC). Maximum torque and angle of rotation at fracture were determined. At the second stage, scanning electron microscopy and morphometric analysis were used to evaluate the apical portion of the working part, cross-sectional geometry, and the inner-to-outer diameter ratio ( K D ) of the PathFile (group IIA), SoCo Plus (group IIB), and Scout RaCe (group IIC) instrument systems at the D 0 and D 3 levels. RESULTS. The maximum torque of the group IB specimens was 2.50±0.12 N⋅cm and was 2.08 and 2.45 times higher than the corresponding values in groups IC and IA, respectively. The greatest angle of rotation at fracture was recorded for the group IA instruments (540±45°), followed by group IC (455±40°), whereas the lowest value was observed in group IB (390±35°; p < 0.001). The instruments differed in the geometry of the apical working part and cross-sectional shape. The highest K D values were recorded for the group IIB specimens: 0.51 at the D 0 level and 0.74 at the D 3 level. CONCLUSIONS. The findings support the use of maximum torque, angle of rotation at fracture, and the geometric characteristics of the apical portion as criteria for the differentiated selection of rotary NiTi instruments for the preparation of calcified root canals, taking into account the risk of torsional locking and the characteristics of the mineralized obstruction.
- Open Access
- 25 April 2023
- Published by National University of Science and Technology MISiS in Izvestiya Vuzov. Tsvetnaya Metallurgiya (Proceedings of Higher Schools. Nonferrous Metallurgy)
- No. 2,p. 15-28
Analysis of the slurry and ceramic properties for investment casting obtained with domestic colloidal silica binders
The quality of cast parts produced by investment casting is largely determined by the quality of the ceramic molds. Currently, aircraft and engine building enterprises are switching to an environmentally friendly colloidal silica binders for the manufacture of ceramic molds. In this work, the dynamic and relative viscosity of slurries prepared using fused silica powder and colloidal silica binders of the VT13-02U (Vakuumteh LLC), Stavroform VS (Polymet LLC), UltraCast One + and UltraCast Prime (both Technopark LLC) manufacturers were determined. It is shown that the slurries prepared on the considered binders have similar viscosity values, and in their rheological properties they are close to Newtonian liquids. The values of dynamic and relative viscosity at a binder content of 400 mL per 1 kg of fused silica powder were ~732 mPa·s and ~380 s, respectively. With an increase in the binder content to 600 mL per 1 kg of fused silica powder, the dynamic and relative viscosity decreased to ~70 mPa·s and ~16 s, respectively. An equation was also found that relates the dynamic viscosity determined using a rotational viscometer and the relative viscosity determined using the VZ-4 viscosimeter. The mechanical properties were determined during three-point bending tests on ceramic samples obtained using slurries on the above-mentioned colloidal silica binders and fused silica stucco. Samples obtained on binders VT13-02U, Stavroform VS and UltraCast One+ showed very similar bending strength values, namely 3.5–4.3 MPa after drying and 5.8–6.1 MPa after firing. Due to the presence of a polymer addition in the binder, the ceramic samples obtained on the UltraCast Prime binder had higher values of bending strength after drying and after firing – 6.4 and 7.2 MPa, respectively. It was also shown that with an increase in the viscosity of the slurry and a decrease in the fraction of fused silica stucco, the strength of the samples increases. The lowest surface roughness was observed for samples obtained with UltraCast grade binders.
- 25 April 2023
- Published by National University of Science and Technology MISiS in Izvestiya Vuzov. Tsvetnaya Metallurgiya (Proceedings of Higher Schools. Nonferrous Metallurgy)
- No. 2,p. 15-28
Open AccessAnalysis of the slurry and ceramic properties for investment casting obtained with domestic colloidal silica binders
The quality of cast parts produced by investment casting is largely determined by the quality of the ceramic molds. Currently, aircraft and engine building enterprises are switching to an environmentally friendly colloidal silica binders for the manufacture of ceramic molds. In this work, the dynamic and relative viscosity of slurries prepared using fused silica powder and colloidal silica binders of the VT13-02U (Vakuumteh LLC), Stavroform VS (Polymet LLC), UltraCast One + and UltraCast Prime (both Technopark LLC) manufacturers were determined. It is shown that the slurries prepared on the considered binders have similar viscosity values, and in their rheological properties they are close to Newtonian liquids. The values of dynamic and relative viscosity at a binder content of 400 mL per 1 kg of fused silica powder were ~732 mPa·s and ~380 s, respectively. With an increase in the binder content to 600 mL per 1 kg of fused silica powder, the dynamic and relative viscosity decreased to ~70 mPa·s and ~16 s, respectively. An equation was also found that relates the dynamic viscosity determined using a rotational viscometer and the relative viscosity determined using the VZ-4 viscosimeter. The mechanical properties were determined during three-point bending tests on ceramic samples obtained using slurries on the above-mentioned colloidal silica binders and fused silica stucco. Samples obtained on binders VT13-02U, Stavroform VS and UltraCast One+ showed very similar bending strength values, namely 3.5–4.3 MPa after drying and 5.8–6.1 MPa after firing. Due to the presence of a polymer addition in the binder, the ceramic samples obtained on the UltraCast Prime binder had higher values of bending strength after drying and after firing – 6.4 and 7.2 MPa, respectively. It was also shown that with an increase in the viscosity of the slurry and a decrease in the fraction of fused silica stucco, the strength of the samples increases. The lowest surface roughness was observed for samples obtained with UltraCast grade binders.