Hüseyin Yakar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hüseyin Yakar has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hamza Kasar
Department of Anatomy, Faculty of Medicine, Selçuk University, Konya, Turkey
2 shared publications - İsMail Kaya
Niğde Ömer Halisdemir Üniversitesi
2 shared publications - Mehmet Selcuk
Department of Anatomy, Faculty of Medicine, Niğde Ömer Halisdemir University, Niğde, Turkey
2 shared publications - Murat Inci
First and Emergency Aid Program, Department of Medical Services and Techniques, Ermenek Uysal and Hasan Kalan Vocational School of Health Services, Karamanoglu Mehmetbey University, Karaman, Turkey
2 shared publications - Enes Kesen
Kocaeli University, Faculty of Engineering, Department of Computer Engineering, Kocaeli, Turkey
1 shared publication
Latest Publications
- 2 November 2026
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 48 (1) , 277
Age-related morphometric and morphological differences in the external aperture of the carotid canal: a retrospective study
- 2 November 2026
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 48 (1) , 277
Age-related morphometric and morphological differences in the external aperture of the carotid canal: a retrospective study
- Open Access
- 5 August 2025
- Published by Dynamic Medical Theories in Dynamic Medical Theories
- Vol. 1 (2) , 62-67
Digital Anatomy of The Mental Foramen: Morphometric Evaluation Based on Multidedector CT Imaging
Aim: This study aims to analyze the morphological characteristics of the mental foramen (MF) in multidetector computed tomography (MDCT) images, thereby reducing the risk of complications in mandibular surgery and anesthesia for dental professionals. Material and method: MDCT images of a total of 300 patients (150 males, 150 females) aged 18-60 years were retrospectively analyzed. Images were acquired in axial and coronal planes with a minimum of 0.5 mm slices. The horizontal (MFh) and vertical (MFv) lengths of the MF and the distances to the alveolar crest (MF-UBM) and mandibular base (MF-LMB) were measured bilaterally. Statistically analyzed. Results: The mean age of the individuals was 32.02±11.77 years and the age difference between genders was not statistically significant (p>0.05). Mean MFv (right 3.27±0.62 mm, left 3.20±0.69 mm) and MFh (right 3.14±0.81 mm, left 3.16±0.85 mm) values were found. All MF measurements were significantly larger in males than females (p0.05). There was a weak, significant negative correlation (r=-0.114, p=0.049) between age and vertical length of the left MF (LMFv). Conclusion: The precise localization and dimensions of the MF are critical to reduce the risk of neurovascular injury in dental procedures. Our findings revealed that MF sizes were larger in men, but did not differ significantly overall by age and side. This information may aid in safer dental procedure planning. Keywords: Mandible, mental foramen, multidetector computed tomography, morphometry.
- 5 August 2025
- Published by Dynamic Medical Theories in Dynamic Medical Theories
- Vol. 1 (2) , 62-67
Open AccessDigital Anatomy of The Mental Foramen: Morphometric Evaluation Based on Multidedector CT Imaging
Aim: This study aims to analyze the morphological characteristics of the mental foramen (MF) in multidetector computed tomography (MDCT) images, thereby reducing the risk of complications in mandibular surgery and anesthesia for dental professionals. Material and method: MDCT images of a total of 300 patients (150 males, 150 females) aged 18-60 years were retrospectively analyzed. Images were acquired in axial and coronal planes with a minimum of 0.5 mm slices. The horizontal (MFh) and vertical (MFv) lengths of the MF and the distances to the alveolar crest (MF-UBM) and mandibular base (MF-LMB) were measured bilaterally. Statistically analyzed. Results: The mean age of the individuals was 32.02±11.77 years and the age difference between genders was not statistically significant (p>0.05). Mean MFv (right 3.27±0.62 mm, left 3.20±0.69 mm) and MFh (right 3.14±0.81 mm, left 3.16±0.85 mm) values were found. All MF measurements were significantly larger in males than females (p0.05). There was a weak, significant negative correlation (r=-0.114, p=0.049) between age and vertical length of the left MF (LMFv). Conclusion: The precise localization and dimensions of the MF are critical to reduce the risk of neurovascular injury in dental procedures. Our findings revealed that MF sizes were larger in men, but did not differ significantly overall by age and side. This information may aid in safer dental procedure planning. Keywords: Mandible, mental foramen, multidetector computed tomography, morphometry.
- Open Access
- 15 January 2025
- Published by LookUs Bilisim A.S. in Medical Records
- Vol. 7 (1) , 31-37
Comparative Analysis of Lateral Radiography and Magnetic Resonance Imaging in the Diagnosis of Lumbar Disc Herniation
Aim: This article investigates the use of X-ray as a cost-effective and feasible alternative to magnetic resonance imaging (MRI) for diagnosing lumbar disc herniation (LDH), a common condition with significant economic impact. Material and Method: We assessed the diagnostic efficacy of lumbar lateral radiography (LLR) in identifying LDH. The study cohort formed from patients, presenting with lumbalgia or lumbosciatalgia. Participants who gave consent and had both MRI and LLR within a one-month period were included. Data normality was evaluated, employing the Kolmogorov-Smirnov test for nonparametric data. Variables were represented as means ± standard deviation, analyzed using the Wilcoxon test, with a p-value of less than 0.05 indicating statistical significance. Results: The study involved 436 patients, 56.8% female and 43.2% male, ranging in age from 18 to 75 years. No significant gender, age, or Body Mass Index (BMI)-related differences were observed in the presence of LDH on radiographs. However, significant differences were noted at the L5-S1 and L4-L5 levels. The LLR showed a sensitivity of 94%, specificity of 95%, and a high agreement of 96.7% among evaluators. Conclusion: Study concludes that LLR achieves a diagnostic success rate comparable to Lumbar MRI for most LDH cases. Notably, it is crucial to employ LLR even in patients presenting with "red flag" signs. LLR stands out as a cost-effective and rapid diagnostic alternative in the assessment of LDH. Nonetheless, it is important to acknowledge that MRI continues to be indispensable in more complex cases or for patients exhibiting specific clinical symptoms.
- 15 January 2025
- Published by LookUs Bilisim A.S. in Medical Records
- Vol. 7 (1) , 31-37
Open AccessComparative Analysis of Lateral Radiography and Magnetic Resonance Imaging in the Diagnosis of Lumbar Disc Herniation
Aim: This article investigates the use of X-ray as a cost-effective and feasible alternative to magnetic resonance imaging (MRI) for diagnosing lumbar disc herniation (LDH), a common condition with significant economic impact. Material and Method: We assessed the diagnostic efficacy of lumbar lateral radiography (LLR) in identifying LDH. The study cohort formed from patients, presenting with lumbalgia or lumbosciatalgia. Participants who gave consent and had both MRI and LLR within a one-month period were included. Data normality was evaluated, employing the Kolmogorov-Smirnov test for nonparametric data. Variables were represented as means ± standard deviation, analyzed using the Wilcoxon test, with a p-value of less than 0.05 indicating statistical significance. Results: The study involved 436 patients, 56.8% female and 43.2% male, ranging in age from 18 to 75 years. No significant gender, age, or Body Mass Index (BMI)-related differences were observed in the presence of LDH on radiographs. However, significant differences were noted at the L5-S1 and L4-L5 levels. The LLR showed a sensitivity of 94%, specificity of 95%, and a high agreement of 96.7% among evaluators. Conclusion: Study concludes that LLR achieves a diagnostic success rate comparable to Lumbar MRI for most LDH cases. Notably, it is crucial to employ LLR even in patients presenting with "red flag" signs. LLR stands out as a cost-effective and rapid diagnostic alternative in the assessment of LDH. Nonetheless, it is important to acknowledge that MRI continues to be indispensable in more complex cases or for patients exhibiting specific clinical symptoms.
- 28 April 2023
- Published by Elsevier in World Neurosurgery
- Vol. 175, e1197-e1209
Low-Cost 3-D-Printer–Assisted Personalized Cranioplasty Treatment: A Case Series of 14 Consecutive Patients
- 28 April 2023
- Published by Elsevier in World Neurosurgery
- Vol. 175, e1197-e1209
Low-Cost 3-D-Printer–Assisted Personalized Cranioplasty Treatment: A Case Series of 14 Consecutive Patients