DWDongjian Wu

Dongjian Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dongjian Wu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Mingjian Sun

    Harbin Institute of Technology

    5 shared publications
  • Haokun Zhang

    Harbin Institute of Technology,Department of Control Science and Engineering,Harbin,China

    2 shared publications
  • Kaicheng Yu

    Harbin Institute of Technology, Weihai,Department of Control Science and Engineering,Weihai,China

    2 shared publications
  • Xiaojing Gong

    Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences

    2 shared publications
  • Yi Shen

    Department of Control Science and Engineering Harbin Institute of Technology Harbin Heilongjiang China

    2 shared publications
  • Chengbo Liu

    Research Laboratory for Biomedical Optics and Molecular Imaging, Shenzhen Key Laboratory for Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China

    1 shared publication

Latest Publications

  • Dynamic Registration-Based Photoacoustic Endoscopic Temperature Imaging for Precision Interventional Thermal Therapy and Monitoring

    by Dongjian Wu, Kaicheng Yu, Haokun Zhang, Rui Hua, Jianwu Zhu, Xiaojing Gong, Mingjian Sun

    Atherosclerosis is a major cause of cardiovascular disease. Photothermal ablation provides a minimally invasive therapeutic approach but remains constrained by the lack of reliable temperature monitoring. Conventional thermometry provides only single-point readings and is easily affected by contact and flow, limiting spatial accuracy. Although array-based photoacoustic thermometry allows non-contact detection, it remains bulky and unsuitable for catheter integration. This study realizes real-time intravascular temperature imaging and monitoring through dynamic registration-corrected photoacoustic endoscopy (PETI-DRC). The system employs a miniaturized dual-modality catheter achieving photoacoustic/ultrasound imaging and angularly registered temperature mapping compatible with clinical interventions. Experiments on phantoms and ex vivo rabbit aortas quantitatively verified frame registration accuracy and temperature estimation reliability through comparison with thermocouple references and microscopic validation. Results show improved inter-frame consistency (average SSIM = 0.9684) and high temperature accuracy (RMSE = 0.65 °C), enabling stable reconstruction of angularly registered temperature images and reliable tracking of thermal dynamics for real-time temperature monitoring. This method provides accurate thermal feedback for safer and more effective photothermal therapy and offers a promising direction for future intravascular interventions.

  • Real‐Time, Tissue‐Adaptive Photoacoustic Thermometry for Precision Endoscopic Thermal Therapy

    by Dongjian Wu, Qingrong Xia, Kaicheng Yu, Yiming Ma, Haokun Zhang, Riqiang Lin, Yi Shen, Xiaojing Gong, Puxiang Lai, Mingjian Sun

    Atherosclerosis is a major cause of cardiovascular diseases, and photothermal ablation offers a minimally invasive alternative but is limited by unreliable thermal monitoring. Conventional probes such as thermocouples and fiber‐optic sensors are direct lesion‐contact probes, providing only point or surface measurements with slow response and failing to capture spatial distributions. Meanwhile, current photoacoustic (PA) thermometry relies on bulky arrays and possesses inadequate resolution for small lesions, which is incompatible with catheter applications. Here, this work achieves real‐time intravascular temperature monitoring through photoacoustic endoscopic thermometry with spatially adaptive weighting (PAET‐SAW). Using a miniaturized single‐element transducer with rotational pullback scanning for 3D acquisition, our PAET system enables dual‐modality imaging with real‐time feedback. Phantom and ex vivo validations demonstrate reliable thermometry at 20 Hz with ≤ 0.68°C error and a ∼2 s faster response than thermocouples. Simulated therapeutic experiments further confirm that PAET‐SAW‐guided monitoring reduces excessive thermal dose and suppresses overshoot, underscoring strong clinical potential for precision intravascular interventions.


  • Open Access

    The application of multi-combinatorial approach in sensitivity improvement of lipid photoacoustic imaging

    by Yi Tan, Dongjian Wu, Xiatian Wang, Chengbo Liu, Mingjian Sun, Xiaojing Gong, Zhihua Xie

    The photoacoustic imaging of lipid is intrinsically constrained by the feeble nature of endogenous lipid signals, posing a persistent sensitivity challenge that demands innovative solutions. Although adopting high-efficiency excitation and detection elements may improve the imaging sensitivity to a certain extent, the application of the elements is inevitably subject to various limitations in practical applications, particularly during in vivo imaging and endoscopic imaging. In this study, we propose a multi-combinatorial approach to enhance the sensitivity of lipid photoacoustic imaging. The approach involves wavelet transform processing of one-dimensional A-line signals, gradient-based denoising of two-dimensional B-scan images, and finally, three-dimensional spatial weighted averaging of the data processed by the previous two steps. This method not only significantly improves the signal-to-noise ratio (SNR) in distinguished feature regions of the image by around 10 dB, but also efficiently extracts weak signals with no distinct features in the original image. After processing with this method, the images acquired under single scanning were compared with those obtained under multiple scanning. The results showed highly consistent image features, with the structural similarity index increasing from 0.2 to 0.8, confirming the accuracy and reliability of the multi-combinatorial approach.