Prince Kwabena Gyekye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Prince Kwabena Gyekye has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
C. Schandorf
3 shared publicationsG. Emi-Reynolds
Radiation Protection Institute, Ghana Atomic Energy Commission, Accra, Ghana
3 shared publications- Emmanuel Ofori Darko
Environmental Protection and Waste Management Centre, Radiation Protection Institute, Ghana Atomic Energy Commission, Legon, P. O. Box LG 80, Accra, Ghana
2 shared publications Geoffrey Emi-Reynolds
School of Nuclear and Allied Sciences, University of Ghana, P.O. Box AE 1, Atomic, Accra, Ghana
2 shared publicationsM. Boadu
Ghana Atomic Energy Commission, Radiological and Medical Sciences Research Institute, PO Box LG80, Legon, Accra , Ghana
2 shared publications- A. R. Awudu
Environmental Protection and Waste Management Centre, Radiation Protection Institute, Ghana Atomic Energy Commission, Legon, P. O. Box LG 80, Accra, Ghana
1 shared publication
Latest Publications
- 12 August 2024
- Published by Springer Nature in Health and Technology
- Vol. 14 (6) , 1167-1174
Dose prediction model and cancer risk estimation as quality check in multi-detector computed tomography
- 12 August 2024
- Published by Springer Nature in Health and Technology
- Vol. 14 (6) , 1167-1174
Dose prediction model and cancer risk estimation as quality check in multi-detector computed tomography
- 28 April 2023
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 54 (2) , 335-342
Dose and secondary cancer-risk estimation of patients undergoing high dose rate intracavitary gynaecological brachytherapy
- 28 April 2023
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 54 (2) , 335-342
Dose and secondary cancer-risk estimation of patients undergoing high dose rate intracavitary gynaecological brachytherapy
- 28 February 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 185 (3) , 351-354
PRELIMINARY STAFF DOSE ASSESSMENT FOR COMMON FLUOROSCOPY GUIDED PROCEDURES AT KORLE-BU TEACHING HOSPITAL, ACCRA, GHANA
Preliminary studies on effective and eye lens doses of six Radiologists, four Cardiologists have been conducted for a period of 3 months. Electronic dosemeters positioned under and over lead apron of staff were used for the dosimetry. The estimated effective dose per month to Cardiologist and Radiologist were 0.01–0.07 mSv and 0.03–0.14 mSv, respectively. The estimated eye lens doses per month to Cardiologists and Radiologists were also 0.15–0.30 mSv and 0.53–3.39 mSv, respectively. The effective doses per month to staff were below the ICRP acceptable limit of 1.67 mSv/month but the upper limit of the range of estimated eye lens dose exceeded the ICRP acceptable limit by a factor of 2. Regular use of protective goggles and consistent eye lens dose monitoring is encouraged at the hospital for dose optimization.
- 28 February 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 185 (3) , 351-354
PRELIMINARY STAFF DOSE ASSESSMENT FOR COMMON FLUOROSCOPY GUIDED PROCEDURES AT KORLE-BU TEACHING HOSPITAL, ACCRA, GHANA
Preliminary studies on effective and eye lens doses of six Radiologists, four Cardiologists have been conducted for a period of 3 months. Electronic dosemeters positioned under and over lead apron of staff were used for the dosimetry. The estimated effective dose per month to Cardiologist and Radiologist were 0.01–0.07 mSv and 0.03–0.14 mSv, respectively. The estimated eye lens doses per month to Cardiologists and Radiologists were also 0.15–0.30 mSv and 0.53–3.39 mSv, respectively. The effective doses per month to staff were below the ICRP acceptable limit of 1.67 mSv/month but the upper limit of the range of estimated eye lens dose exceeded the ICRP acceptable limit by a factor of 2. Regular use of protective goggles and consistent eye lens dose monitoring is encouraged at the hospital for dose optimization.
- 31 May 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 393-397
OPTIMISATION OF SCATTER RADIATION TO STAFF DURING CT-FLUOROSCOPY: MONTE CARLO STUDIES
Studies have shown that there is high radiation exposure to medical staff during computed tomography fluoroscopy (CTF)–guided procedures. This study aims to investigate staff dose reduction techniques considering the CTF gantry positioning in the room and room dimensions in addition to the conventional use of thyroid collars, aprons and eye goggles. A Toshiba Aquilion One 640 slice CT scanner and CTF room were modelled using SimpleGeo. Standing and supine adult mesh phantoms were used to represent the staff and patient. The models were spatially put together on one platform using VOXEL2MCNP. Based on this, MCNPX input files were generated for the studies. CTF gantry and staff positions, and CTF room size were varied for different scenarios. Effective, eye lens and thyroid dose to staff were estimated for each scenario. Additional means of possible dose reduction with respect to positioning of the CTF device and room layout are discussed.
- 31 May 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 393-397
OPTIMISATION OF SCATTER RADIATION TO STAFF DURING CT-FLUOROSCOPY: MONTE CARLO STUDIES
Studies have shown that there is high radiation exposure to medical staff during computed tomography fluoroscopy (CTF)–guided procedures. This study aims to investigate staff dose reduction techniques considering the CTF gantry positioning in the room and room dimensions in addition to the conventional use of thyroid collars, aprons and eye goggles. A Toshiba Aquilion One 640 slice CT scanner and CTF room were modelled using SimpleGeo. Standing and supine adult mesh phantoms were used to represent the staff and patient. The models were spatially put together on one platform using VOXEL2MCNP. Based on this, MCNPX input files were generated for the studies. CTF gantry and staff positions, and CTF room size were varied for different scenarios. Effective, eye lens and thyroid dose to staff were estimated for each scenario. Additional means of possible dose reduction with respect to positioning of the CTF device and room layout are discussed.
- Open Access
- 1 January 2013
- Published by Medknow in Journal of Medical Physics
- Vol. 38 (4) , 185-8
Radiation dose estimation of patients undergoing lumbar spine radiography
Radiation dose to organs of 100 adult patients undergoing lumbar spine (LS) radiography at a University Hospital have been assessed. Free in air kerma measurement using an ionization chamber was used for the patient dosimetry. Organ and effective dose to the patients were estimated using PCXMC (version 1.5) software. The organs that recorded significant dose due to LS radiography were lungs, stomach, liver, adrenals, kidney, pancreas, spleen, galbladder, and the heart. It was observed that the stomach recorded the highest dose (48.2 ± 1.2 μGy) for LS anteroposterior (AP). The spleen also recorded the highest dose (41.2 ± 0.5 μGy) for LS lateral (LAT). The mean entrance surface air kerma (ESAK) of LS LAT (122.2 μGy) was approximately twice that of LS AP (76.3 μGy), but the effective dose for both examinations were approximately the same (LS LAT = 8.6 μSv and LS AP = 10.4 μSv). The overall stochastic health effect of radiation to patients due to LS radiography in the University Hospital is independent of the projection of the examination (AP or LAT).
- 1 January 2013
- Published by Medknow in Journal of Medical Physics
- Vol. 38 (4) , 185-8
Open AccessRadiation dose estimation of patients undergoing lumbar spine radiography
Radiation dose to organs of 100 adult patients undergoing lumbar spine (LS) radiography at a University Hospital have been assessed. Free in air kerma measurement using an ionization chamber was used for the patient dosimetry. Organ and effective dose to the patients were estimated using PCXMC (version 1.5) software. The organs that recorded significant dose due to LS radiography were lungs, stomach, liver, adrenals, kidney, pancreas, spleen, galbladder, and the heart. It was observed that the stomach recorded the highest dose (48.2 ± 1.2 μGy) for LS anteroposterior (AP). The spleen also recorded the highest dose (41.2 ± 0.5 μGy) for LS lateral (LAT). The mean entrance surface air kerma (ESAK) of LS LAT (122.2 μGy) was approximately twice that of LS AP (76.3 μGy), but the effective dose for both examinations were approximately the same (LS LAT = 8.6 μSv and LS AP = 10.4 μSv). The overall stochastic health effect of radiation to patients due to LS radiography in the University Hospital is independent of the projection of the examination (AP or LAT).
- Open Access
- 1 January 2012
- Published by Medknow in Journal of Medical Physics
- Vol. 37 (2) , 112-6
Cancer incidence risks to patients due to hysterosalpingography
Cancer incidence estimates and dosimetry of 120 patients undergoing hysterosalpingography (HSG) without screening at five rural hospitals and with screening using image intensifier-TV at an urban hospital have been studied. Free in air kerma measurements were taken for patient dosimetry. Using PCXMC version 1.5, organ and effective doses to patients were estimated. Incidence of cancer of the ovary, colon, bladder and uterus due to radiation exposure were estimated using biological effects of ionising radiation committee VII excess relative risk models. The effective dose to patients was estimated to be 0.20 ± 0.03 mSv and 0.06 ± 0.01 mSv for procedures with and without screening, respectively. The average number of exposures for both procedures, 2.5, and screening time of 48.1 s were recorded. Screening time contributed majority of the patient doses due to HSG; therefore, it should be optimised as much as possible. Of all the cancers considered, the incidence of cancer of the bladder for patients undergoing HSG procedures is more probable.
- 1 January 2012
- Published by Medknow in Journal of Medical Physics
- Vol. 37 (2) , 112-6
Open AccessCancer incidence risks to patients due to hysterosalpingography
Cancer incidence estimates and dosimetry of 120 patients undergoing hysterosalpingography (HSG) without screening at five rural hospitals and with screening using image intensifier-TV at an urban hospital have been studied. Free in air kerma measurements were taken for patient dosimetry. Using PCXMC version 1.5, organ and effective doses to patients were estimated. Incidence of cancer of the ovary, colon, bladder and uterus due to radiation exposure were estimated using biological effects of ionising radiation committee VII excess relative risk models. The effective dose to patients was estimated to be 0.20 ± 0.03 mSv and 0.06 ± 0.01 mSv for procedures with and without screening, respectively. The average number of exposures for both procedures, 2.5, and screening time of 48.1 s were recorded. Screening time contributed majority of the patient doses due to HSG; therefore, it should be optimised as much as possible. Of all the cancers considered, the incidence of cancer of the bladder for patients undergoing HSG procedures is more probable.
- 11 May 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 149 (2) , 216-221
Radiological assessment of the structural shielding adequacy of the radiotherapy facility at Korle-Bu Teaching Hospital, Accra, Ghana
A (60)Co radiotherapy source with an initial activity of 185 TBq has exhausted its useful half-life and has been replaced with a 222 TBq (60)Co source at the Korle-Bu Teaching Hospital; a radiological assessment was performed to ascertain the shielding integrity of the facility. Dose rate at selected critical positions were calculated for the old and new sources. Dose rate measurements were also performed at these critical locations for the new source. The dose rates at all the critical locations of the public and staff access areas were within the recommended dose rate limit of 0.5 and 7.5 µSv h(-1) for the public and controlled area, respectively. The concrete biological shielding at the facility at the moment is adequate enough to attenuate the gamma photons from the new 222 TBq (60)Co source. High dose rates were recorded at the entrance to the treatment room, it is therefore recommended that optimisation of procedures should be encouraged to restrict activities in this area.
- 11 May 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 149 (2) , 216-221
Radiological assessment of the structural shielding adequacy of the radiotherapy facility at Korle-Bu Teaching Hospital, Accra, Ghana
A (60)Co radiotherapy source with an initial activity of 185 TBq has exhausted its useful half-life and has been replaced with a 222 TBq (60)Co source at the Korle-Bu Teaching Hospital; a radiological assessment was performed to ascertain the shielding integrity of the facility. Dose rate at selected critical positions were calculated for the old and new sources. Dose rate measurements were also performed at these critical locations for the new source. The dose rates at all the critical locations of the public and staff access areas were within the recommended dose rate limit of 0.5 and 7.5 µSv h(-1) for the public and controlled area, respectively. The concrete biological shielding at the facility at the moment is adequate enough to attenuate the gamma photons from the new 222 TBq (60)Co source. High dose rates were recorded at the entrance to the treatment room, it is therefore recommended that optimisation of procedures should be encouraged to restrict activities in this area.
- 10 August 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 142 (2-4) , 88-91
Inter-comparison of safety culture within selected practices in Ghana utilising ionising radiation
The safety culture of selected practices and facilities in Ghana utilising radiation sources or radiation emitting devices has been assessed using a performance indicator, which provided status information on management and operating staff commitment to safety. The questionnaire was based on the following broad areas: general safety considerations, safety policy at the facility level, safety practices at the facility level, definition of responsibility, staff training, safety of the physical structure of the facility and the emergency plans. The analysis showed that the percentage levels of commitment to safety for the respective practices are as follows: conventional radiography, 23.3–90.0 %; research reactor, 73.3 %; gamma irradiation facility, 53.3 %; radiotherapy, 76.7 %; X-ray scanner, 80.0 %; gamma scanner, 76.7 %; industrial radiography 86.7 % and nuclear density practice, 78 %. None of the practices or facilities was able to satisfy all the requirements that will ensure a 100 % level of safety culture.
- 10 August 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 142 (2-4) , 88-91
Inter-comparison of safety culture within selected practices in Ghana utilising ionising radiation
The safety culture of selected practices and facilities in Ghana utilising radiation sources or radiation emitting devices has been assessed using a performance indicator, which provided status information on management and operating staff commitment to safety. The questionnaire was based on the following broad areas: general safety considerations, safety policy at the facility level, safety practices at the facility level, definition of responsibility, staff training, safety of the physical structure of the facility and the emergency plans. The analysis showed that the percentage levels of commitment to safety for the respective practices are as follows: conventional radiography, 23.3–90.0 %; research reactor, 73.3 %; gamma irradiation facility, 53.3 %; radiotherapy, 76.7 %; X-ray scanner, 80.0 %; gamma scanner, 76.7 %; industrial radiography 86.7 % and nuclear density practice, 78 %. None of the practices or facilities was able to satisfy all the requirements that will ensure a 100 % level of safety culture.
- 1 September 2009
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 136 (3) , 203-208
Patient dose assessment due to fluoroscopic exposure for some selected fluoroscopic procedures in Ghana
Organ and effective doses to 90 patients undergoing some selected fluoroscopic examinations at the Korle-Bu Teaching Hospital were estimated using the Monte Carlo-based program (PCXMC version 1.5). Radiation dose was estimated from free-in-air measurements. The mean effective doses were found to be 0.29 ± 0.07, 0.84 ± 0.13, 3.15 ± 0.44, 6.24 ± 0.70 and 0.38 ± 0.05 mSv for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations, respectively. The dose area product was estimated to be 3.55 ± 0.95, 16.44 ± 2.60, 50.81 ± 7.04, 99.69 ± 10.85 and 9.32 ± 0.99 Gy cm2 for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations, respectively. Optimisation of procedures is required for barium enema and barium meal examinations.
- 1 September 2009
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 136 (3) , 203-208
Patient dose assessment due to fluoroscopic exposure for some selected fluoroscopic procedures in Ghana
Organ and effective doses to 90 patients undergoing some selected fluoroscopic examinations at the Korle-Bu Teaching Hospital were estimated using the Monte Carlo-based program (PCXMC version 1.5). Radiation dose was estimated from free-in-air measurements. The mean effective doses were found to be 0.29 ± 0.07, 0.84 ± 0.13, 3.15 ± 0.44, 6.24 ± 0.70 and 0.38 ± 0.05 mSv for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations, respectively. The dose area product was estimated to be 3.55 ± 0.95, 16.44 ± 2.60, 50.81 ± 7.04, 99.69 ± 10.85 and 9.32 ± 0.99 Gy cm2 for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations, respectively. Optimisation of procedures is required for barium enema and barium meal examinations.