MÇMehmet Nur Çetin

Mehmet Nur Çetin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mehmet Nur Çetin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats

    by Mehmet Nur Çetin, Yusuf Sinan Şirin, Doğukan Polat, Batuhan Neyse, Latif Emrah Yanmaz

    Rebound tonometry is widely used for measuring intraocular pressure (IOP) in cats; however, differences in clinical tonometer measurement configuration may contribute to variability in recorded values. This prospective repeated‐measures study compared IOP measurements obtained using horizontal and vertical Tonovet Plus clinical measurement configurations in 32 client‐owned, systemically and ophthalmologically normal conscious cats. Intraocular pressure was measured in the right eye while the probe was directed toward the center of the cornea and positioned 4–8 mm from the corneal surface. The order of horizontal and vertical configurations was randomized for each cat. Measurements were obtained by one experienced veterinary ophthalmologist and a trained student operator group. In the primary linear mixed‐effects analysis accounting for repeated measurements within cats, horizontal configuration was associated with an estimated 2.41‐mmHg higher IOP than vertical configuration ( β = 2.41 mmHg; 95% CI, 1.39–3.44; p < 0.001). The configuration‐associated difference was also observed separately for the experienced instructor (mean difference, 2.81 mmHg; 95% CI, 1.91–3.71; p < 0.001) and across the trained student operator group (2.00 mmHg; 95% CI, 0.81–3.19; p = 0.002). These findings indicate that horizontal and vertical Tonovet Plus clinical measurement configurations may yield different IOP values in conscious cats. As configuration changes may affect instrument handling, restraint, head positioning, and animal responses, the difference cannot be attributed solely to tonometer orientation or mechanics. Consistent configuration is therefore recommended when comparing serial IOP measurements in cats. Further controlled studies are needed to distinguish mechanical, ergonomic, and other examination‐related mechanisms.

  • Radiological and Neurological Evaluation of Vertebral Fractures or Luxations Stabilized with a Polyaxial Screw-Rod System in Dogs: A Ten-Case Series

    by Mehmet Nur Çetin, Yusuf Sinan Sirin

    The purpose of this study was to determine the stabilization of thoracolumbar vertebral fractures or luxations in dogs with a polyaxial screw rod system and its neurological and radiographic data. Ten dogs with thoracolumbar spinal instability were included in the study. Information on medical history, breed, sex, age, body weight, etiology of injury, presence of concomitant injuries, and timing of surgical intervention was recorded for each dog included in the study. General and orthopedic examinations were performed to exclude non-neurological lesions. Neurological (preoperative, immediate postoperative, 1st week, 3rd week) and radiographic (preoperative, immediate postoperative, 1st week, 3rd week) examination data of each dog were recorded and evaluated. The most affected areas were the T3-L3 level in 5 cases and the L4-L7 level in 5 cases. The mean time to surgery was recorded as 23.4 hours. Screws were placed unilaterally in 4 cases and bilaterally in 6 cases. Radiologically, successful screw placement and significant dislocation reduction (92.75%) were achieved in all cases. Neurological improvement was observed, even in cases without deep pain sensation. In addition, 80% improvement was reported in urinary functions. No implant loosening or loss of alignment was observed in any case. All cases remained in the hospital for 21 days. At the 6- month follow-up after surgery, the clinical outcome was 'excellent' in 3 cases, 'functional' in 5 cases and 'poor' in 2 cases. Polyaxial screw-rod systems are a safe and effective stabilization option in the surgical treatment of acute vertebral trauma in dogs.

  • Radiological and Neurological Evaluation of Vertebral Fracture and Luxation Patterns in Cats: A Retrospective Study: 36 Cases (2023-2024).

    by Mehmet Nur Çetin, Yusuf Sirin

    The aim of this retrospective study was to describe vertebral fractures and luxations in cats radiologically and neurologically and to evaluate their correlation with the severity of spinal cord injury. Thirty-six cats were included in the study. Etiology, neurological status and radiographic appearances were evaluated. In the neurological examination, 23 cats (63.8%) exhibited upper motor neuron signs, while the other 13 (36.2%) showed lower motor neuron signs. Based on the Modified Frankel Scale used for neurological grading, 23 cases (63.8%) were recorded as 'grade 0,' while 13 cases (36.2%) were recorded as 'grade 2.' The most frequently affected region was the T3-L3 region in 26 cases (72.2%), followed by the L4-L7 region in 9 cases (25%) and the C6-Th2 region in 1 case (2.8%). According to the Modified Spinal Trauma Scale, wedge compression fracture was the most common lesion. In cats, the caudal vertebral segment was displaced more dorsally. Evaluation of vertebral canal dislocation revealed that the degree of dislocation varied between 0% and 30% in 14 cases and between 50% and 100% in 22 cases. At the same time, a significant relationship was revealed between deep pain sensation and the degree of dislocation. This study demonstrates the importance of radiological findings and neurological examination in determining the prognosis after spinal trauma in cats.

  • Open Access

    Stabilisation of thoracolumbar vertebral fractures and luxations in cats with a polyaxial screw/rod system

    by M. N. Çetin, Y. S. Şirin

    Objectives: The purpose of this study was to determine clinical and neurological data on the stabilisation of thoracolumbar region fractures or luxations in cats with the polyaxial screw rod system. Materials and Methods: The study included 16 cats with thoracic and/or lumbar fractures, luxations and/or instability. Data recorded for each patient included history, cause of vertebral fractures and dislocations, concurrent injury, time to surgery, neurologic examination and neurologic grading preoperatively and postoperatively (postoperatively, week 1, week 3 and month 6), surgical treatment, preoperative x‐ray and postoperative computed tomography imaging findings. Results: The region with the most localized lesions was T3‐L3 in ten cases and L4‐L7 in six cases. Polyaxial screws were placed unilaterally in 13 cases and bilaterally in three cases. A total of 50 polyaxial screws were placed in all cases. Of these, 44 polyaxial screws were placed optimally, four polyaxial screws were breached (screw diameter breach <2 mm) and two screws were broken. Broken screws did not require any revisions. Although 11 of the cases showed improvement in terms of neurological grading, no improvement was observed in five cases. The clinical outcome was excellent in four cases, functional in six cases and poor in six cases. Clinical Significance: The polyaxial screw rod system described here is a potential option for stabilization of thoracolumbar vertebrae in cats.


  • Open Access

    Evaluation of a New Non‐Mydriatic Handheld Fundus Camera for Fundus Imaging in Cats: A Retrospective Study: 208 Cases (2023–2024)

    by Özlem Şengöz Şirin, Mehmet Nur Çetin, Muhammed Yusuf Şirin

    Background: In small animals such as cats, fundus imaging plays a critical role in early diagnosis of eye diseases and monitoring of treatment processes. Traditional methods usually require dilation of the pupil, which in some cases may require anaesthesia or cause discomfort for the animals. In recent years, non‐mydriatic fundus cameras, especially with the development of handheld models, offer a new alternative that simplifies this process. These cameras allow high‐quality fundus images to be obtained without the need for pupil dilation. This helps veterinarians save time and resources during examinations, while also providing a less stressful experience for the animals. Objectives: Evaluation of the use and image quality of the new non‐mydriatic handheld fundus camera (Aurora, Optomed, Oulu, Finland) for fundus imaging in cats. Methods: Fundus photographs of 208 cats were obtained using a handheld, non‐mydriatic fundus camera. Undilated colour images of each eye centred on the optic disc were taken in a dimly lit room using a non‐mydriatic fundus camera. The image acquisition protocol consisted in a single 50° colour photo centred on the cats optic disc. Images were evaluated for normal and pathological fundus. In addition, the obtained fundus images were evaluated in terms of centration, clarity and visible range parameters, with the quality score of each parameter varying between 2 (excellent) and 0 (ungradable). Results: Although 204 of 208 cats had a normal fundus, four cats had retinal pathology. The optic disc was defined as well‐centred in 412 of 416 eyes, partially centred in 3 eyes and not centred in 1 eye. Fundus vessels were clearly visible in 409 eyes, recognisable in 6 eyes and not recognisable in 1 eye. The entire image was visible in 413 eyes; more than 80% of the image was visible in 2 eyes, and less than 80% of the image was visible in 1 eye. The mean image quality scores for image centration, clarity and visible range were 1.99, 1.98 and 1.99, respectively, in 416 eyes. Conclusions: The evaluated fundus camera appears to be suitable for use in fundus imaging in non‐dilated eyes of cats, and the quality of the images obtained is significantly satisfactory.


  • Open Access

    The Usefulness of the HASTE Sequence in the Diagnosis of Spinal Diseases in Dogs and Cats

    by Mehmet Nur Çetin, Yusuf Sirin, Batuhan Neyse

    Single-shot turbo spin-echo sequences are dense T2-weighted sequences that are well suited for evaluating the subarachnoid space. In T2-weighted fast spin-echo sequences routinely used in spinal magnetic resonance (MR) imaging, the subarachnoid space is poorly distinguished from the surrounding epidural fat, which may lead to the under detection of neurological disorders. We aimed to determine the utility of the Half-ourier single-shot turbo spin-echo (HASTE) sequence in the diagnosis of neurological disorders in dogs and cats and the agreement between the HASTE sequence and T2 sequences. The study included 17 patients (cats and dogs) with suspected neurological disorders and an indication for magnetic resonance imaging. One observer was initially asked to interpret T2-weighted images only and then T2-weighted and HASTE sequences together. The MR images were anonymized and no signal, history, or clinical information was provided. Without the HASTE sequence, the observer recognized 71% of the neurological disorders. With the addition of the HASTE sequence, the observer recognized 100% of the neurological disorders. After the addition of the HASTE sequence, the observer was able to make a more accurate diagnosis with a difference of 29%. In addition, according to the results obtained, a moderate to good diagnostic agreement was found between T2-weighted and T2-weighted + HASTE sequences. Without the HASTE sequence, the observer was able to localize 89% of the lesions. With the addition of the HASTE sequence, the observer was able to localize 100% of the lesions, the difference of 11% was not statistically significant (P=0.15). In conclusion, our study has shown that the acquisition of single-shot fast spin-echo sequences in addition to standard T2-weighted fast spin-echo sequences provides more accurate detection of neurological disorders and provides advantages in terms of localization of neurological disorders.

  • Evaluation of blink parameters obtained by electrical stimulation in general anaesthetised dogs

    by Mehmet Nur Çetin, Yusuf Sirin

    The aim of this study was to evaluate the relationship between the blink reflex and general anesthesia in dogs. Dogs brought for castration or ovariohysterectomy without any other problems were included in the study. In dogs anesthetized for the surgical procedure, anesthesia was kept constant at 2.9 MAC. Following the procedure, the supramaximal electrical stimulation was applied to the supraorbital nerve for every 0.1 MAC value decline, beginning at 2.9 end tidal MAC, and blink parameters were recorded from both orbicularis oculi muscles. The latency, amplitude, duration, and differential latency values of blink parameters obtained independently of MAC under general anesthesia were revealed. At the same time, it was also determined which blink parameters were obtained in which MAC value range. Previous studies have shown that the R2 and RC are highly affected by the level of consciousness, and the RC disappears under general anaesthesia. The R2 value was most commonly obtained between 1.1 and 1.0 MAC, but the dogs did not respond to any stimulus when the R2 value was obtained. However, since previous studies have shown that the level of consciousness affects R2 values, it was assumed that surgical anesthesia may have disappeared in the MAC ranges where this value was measured. The MAC value from which the RC value was obtained was found to be 0.88, and it was assumed that it could be accepted as the average MAC value at which the effect of general anesthesia was eliminated for dogs.

  • Open Access

    Treatment of hemihydranencephaly in a cat with ventriculoperitoneal shunt

    by Mehmet Nur Çetin, Yusuf Sirin, Muhammed Yusuf Şirin, Batuhan Neyse

    Hemihydranencephaly is extremely rare in cats. In this case report, the aim is to share data on the diagnosis and treatment of a hemihydranencephaly in a cat. This case report is for an 1 year old, 3 kg, male, Scottish fold cat. The cat was brought in by its owner with behavioural changes and decreased activity since birth. Cranial nerve examination revealed that threat reflex and lateral palpebral reflex were decreased and corneal reflex was delayed. Spinal reflex examination revealed a decreased patellar reflex and proprioceptive deficit in all extremities in the postural reaction test. As a result of the tests, a cranial lesion was suspected. Magnetic resonance imaging revealed that the right cerebral hemisphere and ependyma were absent and instead were filled with fluid. In light of the findings, the patient was diagnosed with a hemihydranencephaly. Furosemide, and prednisone were used for medical treatment. However, despite a week of medical treatment, no improvement was observed. Ventriculoperitoneal shunt placement was preferred as the surgical method. Although all of the patient's neurological findings did not disappear in the postoperative period, they improved. A cat with haemihydraocephaly was successfully treated with ventriculoperitoneal shunt for the first time.

  • Open Access

    Chiari-like malformation in a cat

    by Mehmet Nur Çeti̇n, Batuhan Neyse, Yusuf Si̇ri̇n, Büşranur Kılıç Yıldız

    Chiari-like malformations are rare in cats. In this case report, the aim is to share data on the diagnosis and treatment of a Chiari-like malformation in a cat. This case report is for an 8-month-old, 3 kg, female, mixed-breed cat. The cat was brought in by its owner with complaints of seizures and weakness in the hind limb. Clinical and neurological examination revealed signs of ataxic gait, tetraparesis, allodynia, and decreased corneal reflexes. As a result of the examinations, a cranial or cervical lesion was suspected. Magnetic resonance imaging revealed findings such as ventriculomegaly, cerebellar herniation, medullary kinking, syringomyelia, and decreased cerebrospinal fluid flow at the first cervical level. Computed tomography revealed the absence of atlantooccipital overlap. In light of the findings, the patient was diagnosed with a Chiari-like malformation. Phenobarbital, gabapentin, furosemide, and prednisone were used for medical treatment. However, despite a week of medical treatment, no improvement was observed. Foramen magnum decompression was preferred as the operation method and titanium mesh was used to prevent scar tissue formation. The patient, whose condition improved in the postoperative period, died one week later due to aspiration pneumonia.

  • Open Access

    Right aortic arch with megaesophagus in a jack russel dog and diagnosis with contrast fluoroscopy

    by Yusuf Sirin, Muhammed Yusuf Şirin, Mehmet Nur Çetin

    The material of this case report was a 4-month-old Jack Russel female dog brought to Burdur Mehmet Akif Ersoy University Veterinary Faculty Animal Hospital with the complaint of vomiting. Anamnesis revealed that the patient had chronic vomiting, cough, and respiratory distress following food intake. As a result of examinations, it was determined that the patient had a congenital right aortic arch-type vascular ring anomaly and related megaesophagus. Treatment consisted of a surgical procedure followed by medical therapy. This case report demonstrated that fluoroscopy-guided contrast-enhanced angiography can be used to diagnose vascular ring anomaly.