Cristiana Eugenia Ana Grigorescu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cristiana Eugenia Ana Grigorescu has a total of 292 co-authors. Here are the top co-authors by number of shared publications:
O. Monnereau
Madirel, Aix Marseille Universite, Marseille, France
14 shared publicationsR. Notonier
Aix-Marseille Université , Centrale Marseille, CNRS, Fédération Sciences Chimiques Marseille (FR 1739) - PRATIM, 13000 Marseille , France
12 shared publications- Ileana Cristina Vasiliu
National Institute of R&D for Optoelectronics INOE 2000
11 shared publications - Ana-Maria Iordache
Optospintronics Department, National Institute of Research and Development for Optoelectronics, INOE 2000, 409 Atomistilor, 077125 Magurele, Romania
9 shared publications - Constantin Logofatu
National Institute for Materials Physics
9 shared publications H.J. Trodahl
9 shared publications
Latest Publications
- Open Access
Bone–Ti-Alloy Interaction in Hip Arthroplasty of Patients with Diabetes, Dyslipidaemia, and Kidney Dysfunction: Three Case Reports and Brief Review
Background and Objectives: Organ dysfunctions affect the quality of bone and body fluids. This case report seeks links between the underlying conditions of three patients undergoing hip arthroplasty (HA) with uncemented implants, the quality of their bones, and their Ti-6Al-4V orthopaedic implants, on different time spans. Femoral stems are investigated. A brief review supports our findings. Materials and Methods: Cases: two women (F1 35+, F2 80+), and one man (M 65+), all having diabetes, dyslipidaemia, and kidney dysfunction. Samples: a segment of a broken 7-year-old stem, bone with a metallic layer, soft tissue, segments of one spare stem, and synthetic plasma enriched with glucose and urea according to the biochemistry tests of the respective patients. Vast studies show that cholesterol influences bone quality only. The stem pieces were ultrasonicated for 7 h at 37 °C in synthetic plasma. Scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and profilometry investigated the Ti-alloy samples, electrochemistry analysed the post-sonication plasma, and histopathology examination was performed on the soft tissue remnants on the broken stem. Results: EDX show that all stem samples are Ti-6Al-4V with minute additions of other elements and hydroxyapatite (HAp) coating. SEM and profilometry analysis are consistent for the roughness in the outer layers of the stems. Electrochemistry on the bone fragment shows migration of vanadium during the 6 months since fracture to revision for M. Conclusions: Stems in altered synthetic plasma are affected by glucose and urea. Metal migration from the prostheses can occur through the chemical interactions between body fluids with abnormal biochemistry and the orthopaedic prostheses, favoured by cracks and concurring with wear following friction during usual movements. Cholesterol influences on the bone quality.
Open AccessBone–Ti-Alloy Interaction in Hip Arthroplasty of Patients with Diabetes, Dyslipidaemia, and Kidney Dysfunction: Three Case Reports and Brief Review
Background and Objectives: Organ dysfunctions affect the quality of bone and body fluids. This case report seeks links between the underlying conditions of three patients undergoing hip arthroplasty (HA) with uncemented implants, the quality of their bones, and their Ti-6Al-4V orthopaedic implants, on different time spans. Femoral stems are investigated. A brief review supports our findings. Materials and Methods: Cases: two women (F1 35+, F2 80+), and one man (M 65+), all having diabetes, dyslipidaemia, and kidney dysfunction. Samples: a segment of a broken 7-year-old stem, bone with a metallic layer, soft tissue, segments of one spare stem, and synthetic plasma enriched with glucose and urea according to the biochemistry tests of the respective patients. Vast studies show that cholesterol influences bone quality only. The stem pieces were ultrasonicated for 7 h at 37 °C in synthetic plasma. Scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and profilometry investigated the Ti-alloy samples, electrochemistry analysed the post-sonication plasma, and histopathology examination was performed on the soft tissue remnants on the broken stem. Results: EDX show that all stem samples are Ti-6Al-4V with minute additions of other elements and hydroxyapatite (HAp) coating. SEM and profilometry analysis are consistent for the roughness in the outer layers of the stems. Electrochemistry on the bone fragment shows migration of vanadium during the 6 months since fracture to revision for M. Conclusions: Stems in altered synthetic plasma are affected by glucose and urea. Metal migration from the prostheses can occur through the chemical interactions between body fluids with abnormal biochemistry and the orthopaedic prostheses, favoured by cracks and concurring with wear following friction during usual movements. Cholesterol influences on the bone quality.
- Open Access
- 25 September 2025
- Published by MDPI AG in Preprints.org
Bone-Ti Alloys Interaction in Hip Arthroplasty of Patients with Diabetes, Dyslipidaemia, and Kidney Dysfunction: Three Case Report and Brief Review
Background and Objectives: Great efforts in orthopaedic surgery have been devoted to the ad-vancement in prosthetics, with a focus on various materials with enhanced mechanical, physical, and chemical properties, geometries of implants, and their surface morphology. A considerable in-terest relates to interfaces with the bone tissues, and their surroundings, e.g., body fluids, building interaction with the living body. Organ dysfunctions effect the quality of bone. The objective of the study is to find interconnections between the underlying conditions of patients, the quality of their bones, and their orthopaedic implants, on different time spans. We refer to femoral stems only. Materials and Methods: We report on three cases, two women (F1 aged over 35, and F2 aged over 80), and one man (M aged over 65), with diabetes, dyslipidaemia, and kidney dysfunction, under-going HA with uncemented Ti-alloy implants. The samples examined were: a segment of a broken Ti-alloy stem (7 years old), biological remnants on it (bone with a metallic layer, 1.75 cm2 and 2.53 g, and soft tissue, 1.50cm2 and 1.098 g), segments of two spare stems, and synthetic plasma enriched with glucose, urea, and cholesterol (according to the biochemistry tests of the respective patients). The stem pieces, 20 x 11 x 6.56 mm3, were immersed in the corresponding synthetic plasma at 38 C and ultrasonicated for 7h. Scanning electron microscopy and energy dispersive X-ray spectroscopy were employed to investigate the Ti-alloy stem samples, and electrochemistry - to adequately explore the plasma left after sonication (50µL/sample) of each sample. Histopatho-logical examination was performed on the soft tissue remnants on the broken stem. Results: EDX spectra have shown that all femoral stem samples are of Ti-6Al-4V, with various additions of C, Fe, Si, Zr, coated with hydroxyapatite. The electrochemistry study shows that the metallic layer on the bone fragment was caused by migration of vanadium during the 6 months since fracture to re-vision for M. That finding agrees with analysis of prosthetic vanadium concentration in se-rum/plasma after 6 months, as recently reported by other authors. Conclusions: The reactivity of the stems in altered synthetic plasma is given by the presence of glucose and urea, whereas choles-terol influences on bone quality only. The histopathological analysis shows severe panniculitis and myositis. Numerous neutrophils intermixed by macrophages, and a few lymphocytes, are present, supporting the abundance of small new capillaries (granulation tissue). Metal migration from the prostheses can occur through the chemical interactions between body fluids with abnor-mal biochemistry and the compounds building the orthopaedic prostheses, having however in mind that chemical corrosion, and wear resulting from friction during usual movements of the body, are competing mechanisms, especially through effects like surface cracks. Even though Ti-alloys are fully biocompatible, diabetes, dyslipidaemia, and renal dysfunction alter the bone-implant interface because of dramatically weakened and frail bones, no matter the age, and sex. Therefore, for those patients with complex conditions, it can be anticipated a shorter lifetime of implants till revision than in healthier ones. A brief review supports our experimental findings.
- 25 September 2025
- Published by MDPI AG in Preprints.org
Open AccessBone-Ti Alloys Interaction in Hip Arthroplasty of Patients with Diabetes, Dyslipidaemia, and Kidney Dysfunction: Three Case Report and Brief Review
Background and Objectives: Great efforts in orthopaedic surgery have been devoted to the ad-vancement in prosthetics, with a focus on various materials with enhanced mechanical, physical, and chemical properties, geometries of implants, and their surface morphology. A considerable in-terest relates to interfaces with the bone tissues, and their surroundings, e.g., body fluids, building interaction with the living body. Organ dysfunctions effect the quality of bone. The objective of the study is to find interconnections between the underlying conditions of patients, the quality of their bones, and their orthopaedic implants, on different time spans. We refer to femoral stems only. Materials and Methods: We report on three cases, two women (F1 aged over 35, and F2 aged over 80), and one man (M aged over 65), with diabetes, dyslipidaemia, and kidney dysfunction, under-going HA with uncemented Ti-alloy implants. The samples examined were: a segment of a broken Ti-alloy stem (7 years old), biological remnants on it (bone with a metallic layer, 1.75 cm2 and 2.53 g, and soft tissue, 1.50cm2 and 1.098 g), segments of two spare stems, and synthetic plasma enriched with glucose, urea, and cholesterol (according to the biochemistry tests of the respective patients). The stem pieces, 20 x 11 x 6.56 mm3, were immersed in the corresponding synthetic plasma at 38 C and ultrasonicated for 7h. Scanning electron microscopy and energy dispersive X-ray spectroscopy were employed to investigate the Ti-alloy stem samples, and electrochemistry - to adequately explore the plasma left after sonication (50µL/sample) of each sample. Histopatho-logical examination was performed on the soft tissue remnants on the broken stem. Results: EDX spectra have shown that all femoral stem samples are of Ti-6Al-4V, with various additions of C, Fe, Si, Zr, coated with hydroxyapatite. The electrochemistry study shows that the metallic layer on the bone fragment was caused by migration of vanadium during the 6 months since fracture to re-vision for M. That finding agrees with analysis of prosthetic vanadium concentration in se-rum/plasma after 6 months, as recently reported by other authors. Conclusions: The reactivity of the stems in altered synthetic plasma is given by the presence of glucose and urea, whereas choles-terol influences on bone quality only. The histopathological analysis shows severe panniculitis and myositis. Numerous neutrophils intermixed by macrophages, and a few lymphocytes, are present, supporting the abundance of small new capillaries (granulation tissue). Metal migration from the prostheses can occur through the chemical interactions between body fluids with abnor-mal biochemistry and the compounds building the orthopaedic prostheses, having however in mind that chemical corrosion, and wear resulting from friction during usual movements of the body, are competing mechanisms, especially through effects like surface cracks. Even though Ti-alloys are fully biocompatible, diabetes, dyslipidaemia, and renal dysfunction alter the bone-implant interface because of dramatically weakened and frail bones, no matter the age, and sex. Therefore, for those patients with complex conditions, it can be anticipated a shorter lifetime of implants till revision than in healthier ones. A brief review supports our experimental findings.
- Open Access
Performance Assessment of Three Similar Dental Restorative Composite Materials via Raman Spectroscopy Supported by Complementary Methods Such as Hardness and Density Measurements
(1) Background: A widespread problem in oral health is cavities produced by cariogenic bacteria that consume fermentable carbohydrates and lower pH to 5.5–6.5, thus extracting Ca2+ and phosphate ions (PO43−) from teeth. Dental restorative materials based on polymers are used to fill the gaps in damaged teeth, but their properties are different from those of dental enamel. Therefore, a question is raised about the similarity between dental composites and natural teeth in terms of density and hardness. (2) Methods: We have used Raman spectroscopy and density and microhardness measurements to compare physical characteristics of several restorative dental composites at different polymerization intervals. (3) Results: XRVHerculite®, Optishade®, and VertiseFlow® showed the very different characteristics of the physical properties following four polymerization intervals. Of the three composites, OptiShade showed the highest polymerization rate. (4) Conclusions: Only fully polymerized composites can be used in teeth restoring, because incomplete polymerization would result in cracks, pitting, and lead finally to failure.
Open AccessPerformance Assessment of Three Similar Dental Restorative Composite Materials via Raman Spectroscopy Supported by Complementary Methods Such as Hardness and Density Measurements
(1) Background: A widespread problem in oral health is cavities produced by cariogenic bacteria that consume fermentable carbohydrates and lower pH to 5.5–6.5, thus extracting Ca2+ and phosphate ions (PO43−) from teeth. Dental restorative materials based on polymers are used to fill the gaps in damaged teeth, but their properties are different from those of dental enamel. Therefore, a question is raised about the similarity between dental composites and natural teeth in terms of density and hardness. (2) Methods: We have used Raman spectroscopy and density and microhardness measurements to compare physical characteristics of several restorative dental composites at different polymerization intervals. (3) Results: XRVHerculite®, Optishade®, and VertiseFlow® showed the very different characteristics of the physical properties following four polymerization intervals. Of the three composites, OptiShade showed the highest polymerization rate. (4) Conclusions: Only fully polymerized composites can be used in teeth restoring, because incomplete polymerization would result in cracks, pitting, and lead finally to failure.
- Open Access
The Characteristics of Light (TiCrAl0.5NbCu)CxNy High-Entropy Coatings Deposited Using a HiPIMS/DCMS Technique
Multi-component high-entropy (TiCrAl0.5NbCu)CxNy coatings targeting applications requiring medium-to-high friction and wear-resistant surfaces were fabricated through the co-sputtering of elemental targets in an Ar + CH4 + N2 reactive atmosphere using a hybrid HiPIMS/DCMS technique. Two sets of samples were fabricated: (a) (TiCrAl0.5NbCu)Cx high-entropy carbides (HEC) and (b) (TiCrAl0.5NbCu)CxN0.13 high-entropy carbonitrides (HECN), 0 ≤ x ≤ 0.48. The structural, mechanical, tribological, and corrosion resistance properties were thoroughly investigated. The metallic sample exhibits a single BCC structure that changes to FCC via an intermediary amorphous phase through the addition of C or N to the content of the films. The crystallinity of the FCC phases is enhanced and the density of the films decreases down to 5.5 g/cm3 through increasing the carbon fraction up to 48%. The highest hardness of about 16.9 GPa and the lowest wear rate of about 5.5 × 10−6 mm3/Nm are presented by the samples with the largest carbon content, x = 0.48. We found a very good agreement between the evolution of H/E and H3/E2 parameters with carbon content and the tribological behavior of the coatings. The best corrosion resistance was presented by the low-carbon carbonitride samples, showing a charge transfer resistivity of about 3 × 108 Ω∙cm, which is more than three times larger than that of the metallic HEA. The best tribological characteristics for envisioned application were presented by (TiCrAl0.5NbCu)C0.3N0.13, showing a coefficient of friction of 0.43 and a wear rate of about 7.7 × 10−6 mm3/Nm.
Open AccessThe Characteristics of Light (TiCrAl0.5NbCu)CxNy High-Entropy Coatings Deposited Using a HiPIMS/DCMS Technique
Multi-component high-entropy (TiCrAl0.5NbCu)CxNy coatings targeting applications requiring medium-to-high friction and wear-resistant surfaces were fabricated through the co-sputtering of elemental targets in an Ar + CH4 + N2 reactive atmosphere using a hybrid HiPIMS/DCMS technique. Two sets of samples were fabricated: (a) (TiCrAl0.5NbCu)Cx high-entropy carbides (HEC) and (b) (TiCrAl0.5NbCu)CxN0.13 high-entropy carbonitrides (HECN), 0 ≤ x ≤ 0.48. The structural, mechanical, tribological, and corrosion resistance properties were thoroughly investigated. The metallic sample exhibits a single BCC structure that changes to FCC via an intermediary amorphous phase through the addition of C or N to the content of the films. The crystallinity of the FCC phases is enhanced and the density of the films decreases down to 5.5 g/cm3 through increasing the carbon fraction up to 48%. The highest hardness of about 16.9 GPa and the lowest wear rate of about 5.5 × 10−6 mm3/Nm are presented by the samples with the largest carbon content, x = 0.48. We found a very good agreement between the evolution of H/E and H3/E2 parameters with carbon content and the tribological behavior of the coatings. The best corrosion resistance was presented by the low-carbon carbonitride samples, showing a charge transfer resistivity of about 3 × 108 Ω∙cm, which is more than three times larger than that of the metallic HEA. The best tribological characteristics for envisioned application were presented by (TiCrAl0.5NbCu)C0.3N0.13, showing a coefficient of friction of 0.43 and a wear rate of about 7.7 × 10−6 mm3/Nm.
- Open Access
Spectro-Electrochemical Properties of A New Non-Enzymatic Modified Working Electrode Used for Histamine Assessment in the Diagnosis of Food Poisoning
We successfully prepared a non-enzymatic sensor based on a graphene-thiophene composite for histamine detection. The self-assembling properties of the thiophene onto Au support and the high electrical conductivity of graphene encouraged the choice of this type of composite. The composite was deposited via electrochemical polymerization onto the Au layer of a screen-printed microelectrode. The electropolymerization and electrochemical detection of histamine were both achieved by cyclic voltammetry. Two types of electrolytes were used for the electrochemical detection: (a) phosphate buffer solution (PBS), which showed low-intensity redox peaks for histamine; and (b) trichloroacetic acid (TCA) 0.01 M, which showed improved results over PBS and did not damage the microelectrode. For the concentration range of 100–200 mg/kg, the sensor shows a linear regression pattern for the oxidation peak fitted on the equation Ipa = 123.412 + 0.49933 x, with R2 = 0.94178. The lowest limit of detection was calculated to be 13.8 mg/kg and the limit of quantification was calculated at 46 mg/kg. These results are important since by monitoring the amount of histamine in a food product, early onset of spoilage can be easily detected, thus reducing foodborne poisoning and food waste (by recycling products that are still edible).Open AccessSpectro-Electrochemical Properties of A New Non-Enzymatic Modified Working Electrode Used for Histamine Assessment in the Diagnosis of Food Poisoning
We successfully prepared a non-enzymatic sensor based on a graphene-thiophene composite for histamine detection. The self-assembling properties of the thiophene onto Au support and the high electrical conductivity of graphene encouraged the choice of this type of composite. The composite was deposited via electrochemical polymerization onto the Au layer of a screen-printed microelectrode. The electropolymerization and electrochemical detection of histamine were both achieved by cyclic voltammetry. Two types of electrolytes were used for the electrochemical detection: (a) phosphate buffer solution (PBS), which showed low-intensity redox peaks for histamine; and (b) trichloroacetic acid (TCA) 0.01 M, which showed improved results over PBS and did not damage the microelectrode. For the concentration range of 100–200 mg/kg, the sensor shows a linear regression pattern for the oxidation peak fitted on the equation Ipa = 123.412 + 0.49933 x, with R2 = 0.94178. The lowest limit of detection was calculated to be 13.8 mg/kg and the limit of quantification was calculated at 46 mg/kg. These results are important since by monitoring the amount of histamine in a food product, early onset of spoilage can be easily detected, thus reducing foodborne poisoning and food waste (by recycling products that are still edible). - Open Access
- 3 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2675
Current Innovative Methods of Fetal pH Monitoring—A Brief Review
In this study, we explore the “why?”, and “how?”, monitoring the pH of the fetal scalp is used, and show its limitations. In addition, we review the development of new devices based on the modern physics and nanomaterials serving this topic. Most of the works we found in our search have focused on improving the prognostic of fetal heart rate monitoring, because it is the “golden standard” in determining fetal distress. Although the best-known screening method, it can only provide limited information about the actual status of the fetus. The best predictive assessment, with the highest reproducibility, states that a normal fetal heart rate is indicative of a healthy baby. However, its excellent sensitivity is much reduced when identifying the actual “distress”. This is when second-line monitoring methods come into play to guide the diagnostics and direct the obstetrician towards an action plan. Although a historic method, fetal scalp pH sampling is still under review as to its efficiency and place in the current obstetrics. Continuous surveillance of the fetal parameters is important, especially for the fetuses undergoing intrauterine growth restricted (IUGR). Since fetal scalp blood sampling is still under research and is a randomized controlled trial, which compares the relevance of pH and lactates to the obstetrical situation, the maternal-fetal medicine could greatly benefit from the introduction of engineered nanomedicines to the field.
- 3 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2675
Open AccessCurrent Innovative Methods of Fetal pH Monitoring—A Brief Review
In this study, we explore the “why?”, and “how?”, monitoring the pH of the fetal scalp is used, and show its limitations. In addition, we review the development of new devices based on the modern physics and nanomaterials serving this topic. Most of the works we found in our search have focused on improving the prognostic of fetal heart rate monitoring, because it is the “golden standard” in determining fetal distress. Although the best-known screening method, it can only provide limited information about the actual status of the fetus. The best predictive assessment, with the highest reproducibility, states that a normal fetal heart rate is indicative of a healthy baby. However, its excellent sensitivity is much reduced when identifying the actual “distress”. This is when second-line monitoring methods come into play to guide the diagnostics and direct the obstetrician towards an action plan. Although a historic method, fetal scalp pH sampling is still under review as to its efficiency and place in the current obstetrics. Continuous surveillance of the fetal parameters is important, especially for the fetuses undergoing intrauterine growth restricted (IUGR). Since fetal scalp blood sampling is still under research and is a randomized controlled trial, which compares the relevance of pH and lactates to the obstetrical situation, the maternal-fetal medicine could greatly benefit from the introduction of engineered nanomedicines to the field.
- Open Access
- 26 October 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2593
Graphene-Based Sensor for the Detection of Cortisol for Stress Level Monitoring and Diagnostics
In this work, we study the sensing properties of multi-layer graphene combined with pyrrole in order to elaborate low-cost, high-sensitive material for cortisol detection. Graphene nanoplatelets and pyrrole were dispersed in a solution containing 1M HNO3 by using a powerful ultrasound probe for 10 min, then centrifuged for 30 min at 4000 rpm; polymerization was performed by cyclic voltammetry. The graphene–pyrrole composite was tested to ultra-low levels of cortisol in artificial saliva, consistent to the levels excreted in human salivary samples. The composite was further investigated by Raman spectroscopy and we modeled the interaction between the sensitive layer and cortisol using MarvinBeans software. It shows a good sensitivity for salivary values of cortisol cyclic voltammetry being able to detect a level down to 0.5 ng/mL cortisol.
- 26 October 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2593
Open AccessGraphene-Based Sensor for the Detection of Cortisol for Stress Level Monitoring and Diagnostics
In this work, we study the sensing properties of multi-layer graphene combined with pyrrole in order to elaborate low-cost, high-sensitive material for cortisol detection. Graphene nanoplatelets and pyrrole were dispersed in a solution containing 1M HNO3 by using a powerful ultrasound probe for 10 min, then centrifuged for 30 min at 4000 rpm; polymerization was performed by cyclic voltammetry. The graphene–pyrrole composite was tested to ultra-low levels of cortisol in artificial saliva, consistent to the levels excreted in human salivary samples. The composite was further investigated by Raman spectroscopy and we modeled the interaction between the sensitive layer and cortisol using MarvinBeans software. It shows a good sensitivity for salivary values of cortisol cyclic voltammetry being able to detect a level down to 0.5 ng/mL cortisol.
- Open Access
- 17 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (8) , 1993
Raman Spectroscopy as Spectral Tool for Assessing the Degree of Conversion after Curing of Two Resin-Based Materials Used in Restorative Dentistry
(1) Background: The treatment of dental cavities and restoration of tooth shape requires specialized materials with specific clinical properties, including being easy to model, light-cured, having a natural color, reduced shrinkage, a hardness similar to hydroxyapatite, and no leakage. The dimensional stability of resin composite materials is affected by polymerization shrinkage, degree of conversion (number of π carbon bonds converted into σ ones), thermal contraction and expansion, and interactions with an aqueous environment. (2) Methods: The materials used in our investigation were two composite resins with similar polymer matrices, but different filler (micro/nano filler). To evaluate the properties of samples, we employed the pycnometer technique (pycnometer from Paul Marienfeld Gmbh, Lauda-Königshofen, Germany), RAMAN spectroscopy technique (MiniRam Equipment from B&W Tek Inc., Plainsboro Township, NJ, USA; 785 nm laser source), SEM and EDX (FEI Inspect S.). (3) Results: The size of the filler plays an important role in the polymerization: for the pycnometric results, the larger particle filler (Sample 1) seems to undergo a rapid polymerization during the 45 s curing, while the nanoparticle filer (Sample 2) needs additional curing time to fully polymerize. This is related to a much larger porosity, as proved by SEM images. The lower degree of conversion, as obtained by Raman spectroscopy, in the same geometry means that the same volume is probed for both samples, but Sample 1 is more porous, which means less amount of polymer is probed for Sample 1. (4) Conclusions: For the two composites, we obtained a degree of conversion of 59% for Sample 1 and 93% for Sample 2, after 45 s of curing.
- 17 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (8) , 1993
Open AccessRaman Spectroscopy as Spectral Tool for Assessing the Degree of Conversion after Curing of Two Resin-Based Materials Used in Restorative Dentistry
(1) Background: The treatment of dental cavities and restoration of tooth shape requires specialized materials with specific clinical properties, including being easy to model, light-cured, having a natural color, reduced shrinkage, a hardness similar to hydroxyapatite, and no leakage. The dimensional stability of resin composite materials is affected by polymerization shrinkage, degree of conversion (number of π carbon bonds converted into σ ones), thermal contraction and expansion, and interactions with an aqueous environment. (2) Methods: The materials used in our investigation were two composite resins with similar polymer matrices, but different filler (micro/nano filler). To evaluate the properties of samples, we employed the pycnometer technique (pycnometer from Paul Marienfeld Gmbh, Lauda-Königshofen, Germany), RAMAN spectroscopy technique (MiniRam Equipment from B&W Tek Inc., Plainsboro Township, NJ, USA; 785 nm laser source), SEM and EDX (FEI Inspect S.). (3) Results: The size of the filler plays an important role in the polymerization: for the pycnometric results, the larger particle filler (Sample 1) seems to undergo a rapid polymerization during the 45 s curing, while the nanoparticle filer (Sample 2) needs additional curing time to fully polymerize. This is related to a much larger porosity, as proved by SEM images. The lower degree of conversion, as obtained by Raman spectroscopy, in the same geometry means that the same volume is probed for both samples, but Sample 1 is more porous, which means less amount of polymer is probed for Sample 1. (4) Conclusions: For the two composites, we obtained a degree of conversion of 59% for Sample 1 and 93% for Sample 2, after 45 s of curing.
- Open Access
- 14 December 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2350
Uterine Artery Embolization Combined with Subsequent Suction Evacuation as Low-Risk Treatment for Cesarean Scar Pregnancy
Objective: The aim of this study is to propose a standardized management of care for patients diagnosed with cesarean scar pregnancy (CSP). There are two types of CSP: Type 1 (on the scar) vs. type 2 (in the niche). To date there is no international standard to predict the extent of invasion or the optimal management of CSP. Materials and methods: We used intramuscular methotrexate injection followed by uterine artery embolization combined with suction evacuation as a conservative approach for the treatment of seven patients diagnosed with CSP. Our inclusion criteria, to be satisfied simultaneously, were established as follows: (1) patients with CSP; (2) early gestational age ≤ 9 weeks, and (3) written consent of the proposed treatment of the patient. Results: This course of treatment produced a positive outcome in all cases. We did not have any complications (e.g., emergency hysterectomy, perforation of the uterine cavity, severe hemorrhage, or endometritis) during the procedures or in the follow-up. The most important predictors of successful management are early diagnosis of CSP and orientation of the invasive trophoblast opposite to the scar. Conclusions: The main finding from this series of cases is that associating systemic methotrexate and uterine artery embolization provides efficient and low-risk management of CSP. This treatment regime is adequate for both types of CSPs. We consider that early localization diagnosis of pregnancy following a cesarean delivery is mandatory for CSP morbidity prevention.
- 14 December 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2350
Open AccessUterine Artery Embolization Combined with Subsequent Suction Evacuation as Low-Risk Treatment for Cesarean Scar Pregnancy
Objective: The aim of this study is to propose a standardized management of care for patients diagnosed with cesarean scar pregnancy (CSP). There are two types of CSP: Type 1 (on the scar) vs. type 2 (in the niche). To date there is no international standard to predict the extent of invasion or the optimal management of CSP. Materials and methods: We used intramuscular methotrexate injection followed by uterine artery embolization combined with suction evacuation as a conservative approach for the treatment of seven patients diagnosed with CSP. Our inclusion criteria, to be satisfied simultaneously, were established as follows: (1) patients with CSP; (2) early gestational age ≤ 9 weeks, and (3) written consent of the proposed treatment of the patient. Results: This course of treatment produced a positive outcome in all cases. We did not have any complications (e.g., emergency hysterectomy, perforation of the uterine cavity, severe hemorrhage, or endometritis) during the procedures or in the follow-up. The most important predictors of successful management are early diagnosis of CSP and orientation of the invasive trophoblast opposite to the scar. Conclusions: The main finding from this series of cases is that associating systemic methotrexate and uterine artery embolization provides efficient and low-risk management of CSP. This treatment regime is adequate for both types of CSPs. We consider that early localization diagnosis of pregnancy following a cesarean delivery is mandatory for CSP morbidity prevention.
- Open Access
Functionalized Carbon Nanotubes for Chemical Sensing: Electrochemical Detection of Hydrogen Isotopes
In this study, we propose a palladium-functionalized CNT composite working as a sensitive material to evaluate the deuterium concentration in aqueous samples. The sensitive material was prepared by the deposition of Pd nanoparticles onto MWCNT–OH by the micellization process. A modified electrode was prepared by drop casting 60 μL of Pd-decorated MWCNT suspension on a clean glassy carbon electrode surface. The sensing behavior was investigated in a series of deuterium-enriched solutions ranging from 25 to 10,000 ppm. We performed cyclic voltammetry and impedance spectroscopy studies on the samples. The process is quasi-reversible with the reduction curve more pronounced than the oxidation curve, which indicates a low tendency to desorption for the hydrogen atoms.
Open AccessFunctionalized Carbon Nanotubes for Chemical Sensing: Electrochemical Detection of Hydrogen Isotopes
In this study, we propose a palladium-functionalized CNT composite working as a sensitive material to evaluate the deuterium concentration in aqueous samples. The sensitive material was prepared by the deposition of Pd nanoparticles onto MWCNT–OH by the micellization process. A modified electrode was prepared by drop casting 60 μL of Pd-decorated MWCNT suspension on a clean glassy carbon electrode surface. The sensing behavior was investigated in a series of deuterium-enriched solutions ranging from 25 to 10,000 ppm. We performed cyclic voltammetry and impedance spectroscopy studies on the samples. The process is quasi-reversible with the reduction curve more pronounced than the oxidation curve, which indicates a low tendency to desorption for the hydrogen atoms.