GBG. Baulieu

G. Baulieu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


G. Baulieu has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Characterization of aluminum microwave SQUID multiplexers for CE ν NS detection

    by J Amidei, A Armatol, C Augier, L Bailly-Salins, G Baulieu, L Bergé, J Billard, J Blé, G Brenot, G Bres, et al.

    We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ( μ MUX) prototype for transition-edge sensor readout in the Ricochet experiment. The device consists of aluminum coplanar-waveguide resonators and RF superconducting quantum interference devices with Dolan-style Al/AlO x /Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1–1.5 μ Φ 0 / Hz . With flux-ramp modulation, low-frequency 1 / f noise is suppressed, and the flux sensitivity is around 3–4 μ Φ 0 / Hz , corresponding to a current sensitivity of 24–33 pA / Hz at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier between the μ MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3–0.6 μ Φ 0 / Hz and an effective system noise temperature below 1K. These results establish aluminum μ MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

  • Open Access

    Characterization of mini-CryoCube detectors from the RICOCHET experiment commissioning at the Institut Laue-Langevin

    by A. Armatol, C. Augier, L. Bailly-Salins, G. Baulieu, L. Bergé, J. Billard, J. Blé, G. Bres, J-.L. Bret, A. Broniatowski, et al.

    The experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-g germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 14 ( 3 ) events / ( kg day keV ) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% confidence level limit on the nuclear recoil background of < 9 events / ( kg day keV ) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events / ( kg day keV ) . The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Collaboration with upgraded detectors.


  • Open Access

    Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

    by A. Hayrapetyan, A. Tumasyan, W. Adam, J.W. Andrejkovic, T. Bergauer, S. Chatterjee, K. Damanakis, M. Dragicevic, M. Friedl, E. Frühwirth, et al.

    Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.


  • Top Cited Papers
    Open Access

    Development of the CMS detector for the CERN LHC Run 3

    by A. Hayrapetyan, A. Tumasyan, W. Adam, J.W. Andrejkovic, B. Arnold, H. Bergauer, T. Bergauer, S. Chatterjee, K. Damanakis, M. Dragicevic, et al.

    Since the initial data taking of the CERN LHC, the CMS experiment has undergone substantial upgrades and improvements. This paper discusses the CMS detector as it is configured for the third data-taking period of the CERN LHC, Run 3, which started in 2022. The entire silicon pixel tracking detector was replaced. A new powering system for the superconducting solenoid was installed. The electronics of the hadron calorimeter was upgraded. All the muon electronic systems were upgraded, and new muon detector stations were added, including a gas electron multiplier detector. The precision proton spectrometer was upgraded. The dedicated luminosity detectors and the beam loss monitor were refurbished. Substantial improvements to the trigger, data acquisition, software, and computing systems were also implemented, including a new hybrid CPU/GPU farm for the high-level trigger.


  • Open Access

    Gravity in the local Universe: Density and velocity fields using CosmicFlows-4

    by H. M. Courtois, A. Dupuy, D. Guinet, G. Baulieu, F. Ruppin, P. Brenas

    This article publicly releases 3D reconstructions of the local Universe gravitational field below z = 0.8 that were computed using the CosmicFlows-4 (CF4) catalog of 56 000 galaxy distances and its subsample of 1008 supernovae distances. The article also provides measurements of the growth rate of structure using the pairwise correlation of radial peculiar velocities fσ8 = 0.38(±0.04) (ungrouped CF4), fσ8 = 0.36(±0.05) (grouped CF4), fσ8 = 0.30(±0.06) (supernovae), and of the bulk flow in the 3D-reconstructed local Universe 230 ± 136 km s1 at 300 h100−1 Mpc of distance from thes observer. The exploration of 10 000 reconstructions has led to the conclusion that the distances delivered by the CF4 catalog are compatible with a Hubble constant of H0 = 74.5 ± 0.1 (grouped CF4), H0 = 75.0 ± 0.35 (ungrouped CF4), and H0 = 75.5 ± 0.95 (CF4 supernovae subsample).