ITİlknur Tanboga

İlknur Tanboga

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


İlknur Tanboga has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Efficacy of MTAD solution and Er:YAG laser in smear layer removal from extracted root canals: a sem evaluation.

    by Işıl Kalyoncu, Figen Eren Gi̇ray, Basak Durmus, Yildiz Gari̇p Berker, İ̇lknur Tanboğa

    Objective: The aim of this study was to compare the efficacy of MTAD (a mixture of a tetracycline isomer, an acid, and a detergent), Er:YAG laser, 17% EDTA, and 5.25% NaOCl in removing the smear layer from the surface of instrumented root canals. Materials and Methods: Various organic acids, instruments and lasers have been used to remove the smear layer from the surface of instrumented root canals. Twenty-eight extracted maxillary and mandibular incisors were prepared with rotary files. The teeth were randomly allocated to four treatment groups for final irrigation as follows: (1) 17% EDTA (followed by NaOCl), (2) 5.25% NaOCl, (3) Er:YAG laser, and (4) MTAD. All teeth were processed for scanning electron microscopy (SEM) and the removal of the smear layer was examined in the apical, middle and coronal thirds. Results: At coronal location, NaOCl(2.2±0.4) group had significantly higher scores than MTAD(0.0±0.0), EDTA(0.6±0.4) and Er:YAG laser(0.6±0.4) groups (p<0.001, p=0.039, and p=0.039, respectively). At the middle third, NaOCl(2.6±0.5) scores were significantly higher than MTAD(0.0±0.0) and EDTA(0.8±0.4) groups (p<0.001 and p=0.036 respectively). At apical MTAD (0.4±0.3) group had significantly better scores (p<0.001). Conclusion: The results of this suggest that MTAD is an effective final irrigator agent, particularly in the apical segment of the root canal, which presents challenges during cleaning.

  • Open Access

    Effects of Er,Cr:Ysgg Laser on Microleakage of a Self-Etch Adhesive System

    by Muesser Ahu Durhan, Sirin Guner Onur, Figen Eren Gi̇ray, İlknur Tanboga

    Objectives: The purpose of this in-vitro study was to evaluate the microleakage of a self-etch dentin adhesive system in cavities prepared by a conventional dental bur and an Er,Cr:YSGG laser.Materials and Methods: Forty extracted premolar teeth were selected randomly. Standardized Class V cavity preparations were placed in the buccal and lingual surfaces using a bur and an Er,Cr:YSGG laser. Eighty preparations were randomly assigned to 4 groups of 20 samples each and restored as follows: (G1, Control group) Bur; (G2) Bur + Laser etch; (G3) Er,Cr:YSGG laser; (G4) Er,Cr:YSGG laser + Laser etch. The cavities were restored with a self-etch adhesive system (GC, Unifil Bond) and composite resin (GC, Gradia). The preparations were sectioned buccolingually into three parts and scored for microleakage using a light stereoscope. The data were analyzed with Mann-Whitney U test, and Chi-squared test was used for comparisons across groups. Results: In all groups, there was higher microleakage in the gingival margin than in the occlusal margin. In the control group (G1), the lowest microleakage values were obtained in all the cavities. In comparison among the groups, statistically significant microleakage values were obtained in the occlusal margins. Significantly high microleakage was observed in G4 in comparison to G1 and G3 (p = 0.001, p = 0.003). Conclusions: Preparation and etching by using an Er,Cr:YSGG laser does not decrease microleakage, but this may also be due to the properties of the self-etch adhesive. Further clinical research and long-term follow-ups are needed to analyze the findings in more detail.