YTYuan-Po Tu

Yuan-Po Tu

*This is an algorithmically generated author record based on publicly available information.

Yuan-Po Tu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    COVID-19 Antigen Results Correlate with the Quantity of Replication-Competent SARS-CoV-2 in a Cross-Sectional Study of Ambulatory Adults during the Delta Wave

    by Yuan-Po Tu, Christopher Green, Linhui Hao, Alexander L. Greninger, Jennifer F. Morton, Heather A. Sights, Michael Gale, Paul K. Drain

    Do rapid antigen test results correlate with replication-competent severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (i.e., infectious) virus? In this cross-sectional diagnostic study of 626 adults, the sensitivity of the antigen test to identify replication-competent SARS-CoV-2 was 63.6% in asymptomatic and 91.0% in symptomatic participants. Viral culture titers were the highest at the onset of symptoms and rapidly declined by 7 days after symptom onset.


  • Houston We Have a Problem: Ground Zero for the US Coronavirus Outbreak

    by Yuan-Po Tu

    I looked at my messages and noticed I had missed a call from the county's health district epidemiologist. I wondered what she was calling about but wasn't too worried. As the contact person for infectious disease at our clinic, it was not unusual for me to receive communication from the health department. When she answered the phone, I jokingly asked her what she had to report late on a Friday. What she said next changed our world: two days previously, a patient in our clinic had tested positive for coronavirus (COVID-19).

  • Open Access

    Relative Sensitivity of ID NOW and RT-PCR for Detection of SARS-CoV-2 in an Ambulatory Population: Clinical Evaluation, Systematic Review and Meta-analysis

    by Yuan-Po Tu, Jameel Z Iqbal, Timothy Joseph Oleary

    Importance: The SARS-CoV-2 (COVID-19) virus has infected over 65 million people worldwide and caused over one and half million deaths. Definitive diagnosis and treatment require laboratory confirmation, which is generally based upon Reverse-Transcription Polymerase Chain Reaction (RT-PCR) tests carried out in a high-complexity laboratory. The Abbott ID NOW platform provides fast results but has been criticized for low sensitivity. Objective: To determine the sensitivity of SARS-CoV-2 detection by ID NOW in an ambulatory population presenting for initial diagnostic testing. Design: Consecutive patients presenting at the Febrile Upper Respiratory Infection clinics and other clinics at The Everett Clinic between April 8th and 22nd, 2020 provided two nasal swab samples, which were tested for SARS-CoV-2 using the ID NOW platform and an RT-PCR platform. Patients were excluded if they were unable to demonstrate an understanding of the study, unwilling to commit to having all samples collected, had a history of nosebleed in the past 24 hours, nasal surgery in the past two weeks, chemotherapy treatment with documented low platelet and low white blood cell counts, or acute facial trauma. The sensitivity for each platform was compared with a composite reference standard based upon all tests. In addition, a systematic review (subset of review CRD420202044410 registered on PROSPERO) was conducted using papers identified by searching PubMed, bioRxiv and medRxiv for investigations in which at least 20 subjects were simultaneously tested using ID NOW and RT-PCR, and which appeared between January 1, 2020 and August 16, 2020. Bias was assessed using the QUADAS2 instrument. Meta-analysis was conducted in which the results of this evaluation were combined with those of results from the systematic review to estimate the performance of ID NOW by comparison with RT-PCR. Results: The study enrolled 785 symptomatic patients, 21 of whom tested positive for SARS-CoV-2 by both the ID NOW and RT-PCR assays, and 2 of whom tested positive only with the RT-PCR assay. In addition, the study enrolled 189 asymptomatic patients, none of whom tested positive by either ID NOW or RT-PCR. An invalid ID NOW assay result was reported for 9 subjects (2 asymptomatic, 7 symptomatic), all of whom tested negative by RT-PCR. Thus, the positive percent agreement between the ID NOW assay and the RT-PCR assay was 91.3%, and the negative percent agreement was 100%. The meta-analysis, which included the results of this evaluation together with results from our systematic review, allows us to estimate the sensitivity of the ID NOW assay to be 84% (95% CI 55-96%), and identifies patients with viral loads most likely to be associated with transmissible infections. Discussion: This clinical study and meta-analysis show that although the ID NOW platform is not as sensitive as RT-PCR for identification of SARS-CoV-2, it nevertheless provides a high positive and negative predictive value in many populations. Conclusions are limited by the relatively small sizes of many of the studies included in the systematic review and meta-analysis, together with the heterogeneity of populations enrolled and nucleic acid amplification tests utilized for comparison.


  • Open Access

    Polyester Nasal Swabs Collected in a Dry Tube are a Robust and Inexpensive, Minimal Self-Collection Kit for SARS-CoV-2 Testing

    by Leah R. Padgett, Lauren A. Kennington, Charlotte L. Ahls, Delini K. Samarasinghe, Yuan-Po Tu, Michelle L. Wallander, James S. Elliott, Douglas Rains

    Background: Polyester nasal swabs stored in saline or in a dry tube were evaluated as an alternative to foam nasal swabs for SARS-CoV-2 testing by reverse transcription quantitative polymerase chain reaction (RT-qPCR) since they may be inexpensively manufactured at high capacity.Methods: Surrogate clinical specimens were prepared by inoculating foam and polyester nasal swabs with residual SARS-CoV-2 positive clinical specimens diluted in porcine or human matrix. Dry swab elution with phosphate buffered saline (PBS) was evaluated by vortex, swab swirling, and passive methodologies. Surrogate and clinical nasal specimen stability were evaluated at refrigerated (4°C) and elevated temperatures (40°C for 12 hours, 32°C hold) through 72 hours.Results: Polyester swabs demonstrated equivalent performance to foam swabs for detection of low and high SARS-CoV-2 viral loads. Dry swab elution performed with PBS and mechanical disruption by vortex resulted in nearly complete quantitative recovery of virus. Dry polyester and foam surrogate specimens were stable through 72 hours both when refrigerated and after high temperature excursion, which simulated specimen transport without cold chain. Similarly, clinical specimens collected with polyester swabs and stored dry were stable through 72 hours in the presence and absence of cold chain. Polyester surrogate specimens stored in saline were stable through 72 hours refrigerated but only through 48 hours at elevated temperatures.Conclusions: Polyester nasal swabs stored in dry collection tubes comprise a robust and inexpensive self-collection method for SARS-CoV-2 viral load testing, which is stable under conditions required for home collection and shipment to the laboratory.


  • Open Access

    A comparison of health care worker-collected foam and polyester nasal swabs in convalescent COVID-19 patients

    by Brian Hart, Yuan-Po Tu, Rachel Jennings, Prateek Verma, Leah R Padgett, Douglas Rains, Deneen Vojta, Ethan M Berke

    Background: The exponential growth of COVID-19 cases and testing has created supply shortages at various points in the testing workflow. As of April 15, 2020 FDA recommendations only allowed for the use of nasopharyngeal, flocked mid turbinate, or foam nasal swabs, all of which are in very low supply. Polyester swabs are more readily available and mass producible. We compare the performance of polyester and foam swabs stored in different transport media. Methods: Both polyester and foam nasal swabs were collected from convalescent COVID-19 patients at a single visit. Using the foam nasal swabs as the comparator, sensitivity of the polyester swabs in each media were calculated, three by three tables were constructed to measure concordance, and cycle threshold (Ct) values were compared. Findings: 126 visits had polyester and foam swabs stored in viral transport media (VTM), 51 had polyester and foam swabs stored in saline, and 63 had a foam swab in VTM and a polyester swab stored in a dry tube. Using nasal foam swabs as a comparator, polyester nasal swabs had a sensitivity of 86·5% when both samples were stored in VTM, 86·7% when both samples were stored in saline, and 72·4% when the polyester swab was stored dry and the foam swab was stored in VTM. Polyester and foam Ct values from the same visit were correlated, but polyester swabs showed decreased performance for cases with a viral load near the detection threshold and higher Ct values on average. Interpretation: Polyester nasal swabs showed a reduction in performance from foam nasal swabs, but may still provide a viable sample collection method given the current supply shortages and public health emergency. Funding: Laboratory testing was conducted with financial support from Thermo Fisher Scientific.


  • Open Access

    Patient-collected tongue, nasal, and mid-turbinate swabs for SARS-CoV-2 yield equivalent sensitivity to health care worker collected nasopharyngeal swabs

    by Yuan-Po Tu, Rachel Jennings, Brian Hart, Gerald Cangelosi, Rachel Wood, Kevin Wehber, Prateek Verma, Deneen Vojta, Ethan M Berke

    Background: Current testing for SARS-CoV-2 requires health care workers to collect a nasopharyngeal (NP) sample from a patient. NP sampling requires the use of personal protective equipment that are in limited supply, is uncomfortable for the patient, and reduces clinical efficiency. This study explored the equivalency of patient-collected tongue, anterior nares (nasal), and mid-turbinate (MT) samples to health care worker-collected NP samples for detecting SARS-CoV-2. Methods: Patients presenting to five urgent care facilities with symptoms indicative of an upper respiratory infection provided self-collected samples from three anatomic sites along with a health care worker-collected NP sample. Using NP as the comparator, sensitivities and one-sided 95% confidence intervals for the tongue, nasal, and MT samples for detection of SARS-CoV-2 were calculated. Results: The sensitivity for detecting SARS-CoV-2 in patient-collected tongue, nasal, and mid-turbinate samples was 89.8% (95% CI: 80.2 -100.0), 94.0 (95% CI: 84.6-100.0) and 96.2 (95% CI: 87.7-100.0), respectively. Among samples yielding positive results, cycle threshold (Ct) values (a measure of viral load) had correlation coefficients of 0.48, 0.78, and 0.86 between the NP samples and the tongue, nasal, and MT samples, respectively. Conclusions: Patient-collected nasal and MT samples demonstrated high sensitivity for SARS-CoV-2 detection using health care worker-collected NP samples as the comparator. Among patients testing positive with NP samples, nasal and MT Ct values demonstrated high correlations with those Ct values of the NP samples. Patient-collected nasal or MT sampling may improve efficiency for COVID-19 testing while reducing the risk of exposure of the health workforce.