Guang Zeng
Guang Zeng has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Jun Zhu
Wuyi University 22 Dongcheng Village
4 shared publicationsGuanling Li
School of Applied Physics and Materials
3 shared publicationsGuiru Li
Wuyi University 22 Dongcheng Village
3 shared publications- Guoxing Sun
University of Macau Avenida da Universidade
3 shared publications - Yue Xin
School of Applied Physics and Materials Wuyi University Jiangmen P.R. China
3 shared publications Shousen Chen
School of Applied Physics and Materials, Wuyi University, 22 Dongcheng Village, Jiangmen 529020, Guangdong, China
2 shared publications
Latest Publications
- 7 September 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (37) , 12535-12545
3D Direct-Ink-Writing Eutectogel with Programmable Architecture for Multimodal Wearable Interfaces in Personalized Rehabilitation
Here, we report a 3D-printable eutectogel with programmable architectures for multimodal rehabilitation interfaces. The eutectogel is fabricated via polymerization of acrylamide in a ternary deep eutectic solvent, with carbomer and carbon nanotubes incorporated to optimize the rheology, mechanical robustness, and ion/electron conductive network. The optimized formulation possesses mechanical compliance, fatigue resistance, high conductivity, and antifreezing/dehydration properties, while it supports high-fidelity 3D direct ink writing. By programming device architectures, the eutectogel is printed into capacitive pressure sensors, resistive strain sensors, and a Morse-Code touch interface. The pressure sensor shows a sensitivity of 1.01 kPa–1, a detection limit of 29 Pa, and a range of ∼1 MPa, while the strain sensor achieves a gauge factor of 2.17. The eutectogel can also function as a bioelectrode for stable electromyography and electrocardiography signals acquisition. These integrated modules enable motion tracking, physiological monitoring, and active emergency feedback for personalized rehabilitation.
- 7 September 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (37) , 12535-12545
3D Direct-Ink-Writing Eutectogel with Programmable Architecture for Multimodal Wearable Interfaces in Personalized Rehabilitation
Here, we report a 3D-printable eutectogel with programmable architectures for multimodal rehabilitation interfaces. The eutectogel is fabricated via polymerization of acrylamide in a ternary deep eutectic solvent, with carbomer and carbon nanotubes incorporated to optimize the rheology, mechanical robustness, and ion/electron conductive network. The optimized formulation possesses mechanical compliance, fatigue resistance, high conductivity, and antifreezing/dehydration properties, while it supports high-fidelity 3D direct ink writing. By programming device architectures, the eutectogel is printed into capacitive pressure sensors, resistive strain sensors, and a Morse-Code touch interface. The pressure sensor shows a sensitivity of 1.01 kPa–1, a detection limit of 29 Pa, and a range of ∼1 MPa, while the strain sensor achieves a gauge factor of 2.17. The eutectogel can also function as a bioelectrode for stable electromyography and electrocardiography signals acquisition. These integrated modules enable motion tracking, physiological monitoring, and active emergency feedback for personalized rehabilitation.
- 20 November 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (48) , 33073-33082
Melamine Foam Functionalized with a Plastic-Crystal Electrolyte for Advanced Iontronic Pressure Sensors
Iontronic pressure sensors (IPSs) with foam-based microstructures have exhibited greatly enhanced sensitivity compared with other types of IPSs. Nevertheless, ion leakage and limited structural compressibility prevent them from achieving satisfactory stability and a broad pressure range. Herein, a novel IL-like plastic-crystal electrolyte (PCE) is introduced into a polymeric melamine foam (MF) skeleton to prepare an ionic dielectric layer for IPS. The incorporation of PCE not only produces an extra EDL capacitance contribution but also promotes the structural compressibility of the dielectric layer. Consequently, the MF/PCE sensor exhibits a high sensitivity of 0.16 kPa-1 within 1.0 MPa and a relatively high sensitivity of 0.08 kPa-1 within the ultrabroad pressure range of 1.0-2.8 MPa. Owing to the solid state of PCE at ambient conditions and its good compatibility with MF, the composite film does not experience any ion leakage or solid detachment issues, even at large compression pressures. Therefore, the resultant MF/PCE sensor exhibits remarkable durability over 8300 cycles at a large pressure of 85 kPa. The MF/PCE sensor is successfully applied to assess yoga pose accuracy and detect plantar pressure distributions. Our MF/PCE sensor displays great promise in human motion detection and provides an economic and convenient method for real-time sports performance monitoring.
- 20 November 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (48) , 33073-33082
Melamine Foam Functionalized with a Plastic-Crystal Electrolyte for Advanced Iontronic Pressure Sensors
Iontronic pressure sensors (IPSs) with foam-based microstructures have exhibited greatly enhanced sensitivity compared with other types of IPSs. Nevertheless, ion leakage and limited structural compressibility prevent them from achieving satisfactory stability and a broad pressure range. Herein, a novel IL-like plastic-crystal electrolyte (PCE) is introduced into a polymeric melamine foam (MF) skeleton to prepare an ionic dielectric layer for IPS. The incorporation of PCE not only produces an extra EDL capacitance contribution but also promotes the structural compressibility of the dielectric layer. Consequently, the MF/PCE sensor exhibits a high sensitivity of 0.16 kPa-1 within 1.0 MPa and a relatively high sensitivity of 0.08 kPa-1 within the ultrabroad pressure range of 1.0-2.8 MPa. Owing to the solid state of PCE at ambient conditions and its good compatibility with MF, the composite film does not experience any ion leakage or solid detachment issues, even at large compression pressures. Therefore, the resultant MF/PCE sensor exhibits remarkable durability over 8300 cycles at a large pressure of 85 kPa. The MF/PCE sensor is successfully applied to assess yoga pose accuracy and detect plantar pressure distributions. Our MF/PCE sensor displays great promise in human motion detection and provides an economic and convenient method for real-time sports performance monitoring.
- 17 June 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (26) , 38532-38544
Supertough, Healable, Self-Adhesive, and Antibacterial Eutectogels for Sensitive Strain Sensors
Recently, eutectogels featuring the superiority of high ionic conductivity, good biocompatibility, and environmental stability have emerged as one of the most promising materials for fabricating flexible sensors. Nevertheless, the development of eutectogels with high toughness, self-healing, self-adhesion, and antibacterial properties simultaneously remains challenging. Herein, hydrophobic association eutectogels composed of poly(acrylic acid) (PAA) as the main polymer backbone, lauryl methacrylate/sodium dodecyl sulfate (LMA/SDS) as a micellar cross-linker, and choline chloride (ChCl)/protocatechuic acid (PCA)/water as the ternary deep eutectic solvent (t-DES) have been successfully synthesized. Owing to the reversible hydrophobic association and hydrogen bonding in gels, the eutectogels give an excellent toughness of 17.77 MJ/m3, an ultrahigh fracture strain of 4776%, and a desirable self-healing property. Furthermore, due to the incorporation of PCA with choline chloride (ChCl), the eutectogels demonstrate remarkable self-adhesion and antimicrobial performance. The eutectogels also possess desirable harsh environmental tolerance properties owing to the strong hydrogen-bonding networks in t-DES. The strain sensors prepared by eutectogels show the highest gauge factor (GF) of 62.8 and a wide detection range (3000%), which can be used to detect human motion even in low-temperature environments. This study will facilitate the progress of supertough and multifunctional eutectogels in wearable electronics.
- 17 June 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (26) , 38532-38544
Supertough, Healable, Self-Adhesive, and Antibacterial Eutectogels for Sensitive Strain Sensors
Recently, eutectogels featuring the superiority of high ionic conductivity, good biocompatibility, and environmental stability have emerged as one of the most promising materials for fabricating flexible sensors. Nevertheless, the development of eutectogels with high toughness, self-healing, self-adhesion, and antibacterial properties simultaneously remains challenging. Herein, hydrophobic association eutectogels composed of poly(acrylic acid) (PAA) as the main polymer backbone, lauryl methacrylate/sodium dodecyl sulfate (LMA/SDS) as a micellar cross-linker, and choline chloride (ChCl)/protocatechuic acid (PCA)/water as the ternary deep eutectic solvent (t-DES) have been successfully synthesized. Owing to the reversible hydrophobic association and hydrogen bonding in gels, the eutectogels give an excellent toughness of 17.77 MJ/m3, an ultrahigh fracture strain of 4776%, and a desirable self-healing property. Furthermore, due to the incorporation of PCA with choline chloride (ChCl), the eutectogels demonstrate remarkable self-adhesion and antimicrobial performance. The eutectogels also possess desirable harsh environmental tolerance properties owing to the strong hydrogen-bonding networks in t-DES. The strain sensors prepared by eutectogels show the highest gauge factor (GF) of 62.8 and a wide detection range (3000%), which can be used to detect human motion even in low-temperature environments. This study will facilitate the progress of supertough and multifunctional eutectogels in wearable electronics.
- 15 March 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (13) , 5425-5434
Liquid Metal Composite Organohydrogel Based on Water-Soluble Starch Stabilizer with Supertoughness, Self-Healing, and Harsh-Environmental Tolerance for an Advanced Strain Sensor
In this work, a supertough, self-healable, and extreme-environment-tolerable liquid metal (LM) composite organohydrogel was fabricated by dispersing LM particles (LMPs) with water-soluble starch (WS) and leveraging multilevel hydrogen-bonding interactions. Attributed to the cooperation of the strong dual-hydrogen bonds and weak monohydrogen bonds, the organohydrogel obtained an outstanding tensile strength of 2.0 ± 0.13 MPa and toughness of 16.0 ± 1.0 MJ m-3, as well as desirable self-healing ability. The organohydrogel strain sensor has a high gauge factor (GF) of 15.08 along with a large detection range (0-1159%), demonstrating its outstanding sensitivity. It was successfully applied for manipulator gesture detection in harsh environments, showing excellent detection resolution and sensing stability in a wide temperature range (-20 to 50 °C). This work provides a new avenue for preparing multifunctional LM composite gels, showing great promise for next-generation wearable electronics.
- 15 March 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (13) , 5425-5434
Liquid Metal Composite Organohydrogel Based on Water-Soluble Starch Stabilizer with Supertoughness, Self-Healing, and Harsh-Environmental Tolerance for an Advanced Strain Sensor
In this work, a supertough, self-healable, and extreme-environment-tolerable liquid metal (LM) composite organohydrogel was fabricated by dispersing LM particles (LMPs) with water-soluble starch (WS) and leveraging multilevel hydrogen-bonding interactions. Attributed to the cooperation of the strong dual-hydrogen bonds and weak monohydrogen bonds, the organohydrogel obtained an outstanding tensile strength of 2.0 ± 0.13 MPa and toughness of 16.0 ± 1.0 MJ m-3, as well as desirable self-healing ability. The organohydrogel strain sensor has a high gauge factor (GF) of 15.08 along with a large detection range (0-1159%), demonstrating its outstanding sensitivity. It was successfully applied for manipulator gesture detection in harsh environments, showing excellent detection resolution and sensing stability in a wide temperature range (-20 to 50 °C). This work provides a new avenue for preparing multifunctional LM composite gels, showing great promise for next-generation wearable electronics.
- 24 April 2023
- Published by Wiley in Journal of the Society for Information Display
- Vol. 31 (8) , 522-528
The effect of the crystallization of indium tin oxide on indium tin oxide wet etching based on gate line with the structure of copper/indium tin oxide
In thin film transistor‐liquid crystal display (TFT‐LCD), the copper/indium tin oxide (Cu/ITO) layer was often used to be gate line. In this event, the patterning of ITO is necessary and important. However, the high temperature generated during Cu deposition will cause ITO to crystallize, which is not conducive to ITO etching. In this paper, the ITO films prepared by radio frequency (RF) magnetron sputtering were annealed according to the monitoring results of production line to simulate and study the effect of crystallization on the etching properties of ITO film. When the annealing temperature was less than 200°C, no large size grains were detected in ITO films, and the ITO films could be easily etched by etchant. However, the ITO films transformed from amorphous structure to polycrystalline structure after being annealed more than 200°C. After wet etching experiments, the polycrystalline ITO films could be hardly removed by etchant. The X‐ray photoelectron spectroscopy (XPS) results showed that high temperature annealing induced a large amount of Sn4+ on ITO films surface. The Sn4+ was difficult to be dissolved by acid under normal conditions, which might be the most important factors that led to the greatly decreased etching rate for polycrystalline ITO films.
- 24 April 2023
- Published by Wiley in Journal of the Society for Information Display
- Vol. 31 (8) , 522-528
The effect of the crystallization of indium tin oxide on indium tin oxide wet etching based on gate line with the structure of copper/indium tin oxide
In thin film transistor‐liquid crystal display (TFT‐LCD), the copper/indium tin oxide (Cu/ITO) layer was often used to be gate line. In this event, the patterning of ITO is necessary and important. However, the high temperature generated during Cu deposition will cause ITO to crystallize, which is not conducive to ITO etching. In this paper, the ITO films prepared by radio frequency (RF) magnetron sputtering were annealed according to the monitoring results of production line to simulate and study the effect of crystallization on the etching properties of ITO film. When the annealing temperature was less than 200°C, no large size grains were detected in ITO films, and the ITO films could be easily etched by etchant. However, the ITO films transformed from amorphous structure to polycrystalline structure after being annealed more than 200°C. After wet etching experiments, the polycrystalline ITO films could be hardly removed by etchant. The X‐ray photoelectron spectroscopy (XPS) results showed that high temperature annealing induced a large amount of Sn4+ on ITO films surface. The Sn4+ was difficult to be dissolved by acid under normal conditions, which might be the most important factors that led to the greatly decreased etching rate for polycrystalline ITO films.