TATheodor Abart

Theodor Abart

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Theodor Abart has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing Left Ventricular Assist Device Usability: A Comparative Simulation Study of CorWave and HeartMate 3 Peripherals

    by Gregor Widhalm, Theodor Abart, Katharina Ebenberger, Angelika Berger, Roxana Moayedifar, Daniel Zimpfer, Julia Riebandt, Michael Wagner, Thomas Schlöglhofer

    Left ventricular assist devices (LVADs) improve outcomes but often compromise quality of life (QoL) due to usability issues with wearables. This study compared the usability of CorWave LVAD (CW) peripherals prototypes to HeartMate 3 LVAD (HM3) peripherals through a cross-sectional, simulation-based approach involving LVAD-naive laypeople, and heart transplantation (HTX) patients post-LVAD support. Simulations encompassed six tasks, measuring initial success rates, duration to success, pump-off time, and a post-scenario survey. Forty-six untrained participants (16 CW vs. 30 HM3; 12.5% vs. 20% female, p = 0.69; 56.2% vs. 50.0% HTX patients, p = 0.76) completed 276 scenarios. The CW cohort demonstrated superior initial success rates (92.7% vs. 80.6%, p = 0.008). Battery exchanges (in normal and dim light, within carry bag) were completed twice as quickly for CW users ( p ≤ 0.001). Although controller exchange success rates were comparable, the duration to success and pump-off times were doubled for the HM3 cohort ( p ≤ 0.005). During the “connection to AC power” scenario, HM3 subjects experienced higher complexity, as the CW cohort achieved 5× lower duration to success and 3× higher initial success rates ( p ≤ 0.001). Survey responses favored CW cable lengths (92.9% vs. 69.0%, p = 0.001). This study highlights the advantages of CW’s user-centered design, which may enhance QoL and safety for future LVAD patients.


  • Open Access

    Human Factors Evaluation of HeartMate 3 Left Ventricular Assist Device Peripherals: An Eye Tracking Supported Simulation Study

    by Gregor Widhalm, Theodor Abart, Moritz Noeske, Lisa Kumer, Katharina Ebenberger, Clemens Atteneder, Angelika Berger, Günther Laufer, Dominik Wiedemann, Daniel Zimpfer, et al.

    Background: Despite recent design improvements, human factors issues continue to challenge left ventricular assist device (LVAD) therapy. The aim of this study was to evaluate user experience of former non-HeartMate 3 (HM3) LVAD patients post heart transplantation (HTX) and laypersons (LP) with HM3 LVAD peripherals in simulated everyday and emergency scenarios. Methods: This single center cohort study included untrained HTX and LP. Seven scenarios, including battery exchanges (without alarm, advisory alarm, dim light, consolidated bag), change of power supply, driveline dis-/reconnection and controller exchange were simulated. Subjects’ gaze behavior was recorded using eye tracking technology. Success rate, pump-off-time, duration to success (DTS), percental fixation duration per areas of interest and post-scenario-survey results were defined as outcome measures. Results: Thirty subjects completed 210 scenarios, initially solving 82.4% (HTX vs. LP, p = 1.00). Changing power supply revealed highest complexity (DTS = 251 ± 93s, p = 0.76): 26.7% succeeded at first attempt (p = 0.68), 56.7% at second attempt, with significantly more LP failing (p = 0.04), resulting in 10 hazards from driveline disconnections (pump-off-time 2-118s, p = 0.25). Comparison on initial success showed differences in fixation durations for seven areas of interest (p < 0.037). Decreasing DTS during battery exchanges (p < 0.001) indicate high learnability. Exchanging batteries within the bag took longer (median DTS = 75.0 (IQR = 45.0)s, p = 0.09), especially in elderly subjects (r = 0.61, p < 0.001). Subjects with less initial success were more afraid of making mistakes (p = 0.048). Conclusion: This eye tracking based human factors study provided insights into user experiences in handling HM3 peripherals. It highlights unintuitive and hazardous characteristics, providing guidance for future user-centered design of LVAD wearables.