Lukas Burger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lukas Burger has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Sandy Engelhardt
Heidelberg University Hospital
3 shared publications - Alexander Meyer
Charité – Universitätsmedizin Berlin, corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin , Charitéplatz 1, Berlin 10117
2 shared publications Andreas Leha
DZHK (German Centre for Cardiovascular Research), Partner Site Lower Saxony, Göttingen, Germany
2 shared publications- Anja Hennemuth
Deutsches Herzzentrum der Charite
2 shared publications - Clemens Scherer
Department of Medicine I, LMU University Hospital, LMU Munich, Munich, Germany
2 shared publications - Eike Nagel
Institute for Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, Goethe University Frankfurt, Germany (E.N.).
2 shared publications
Latest Publications
- Open Access
- 4 June 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (1) , 203-204
Correction: Multi-modal dataset creation for federated learning with DICOM-structured reports
- 4 June 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (1) , 203-204
Open AccessCorrection: Multi-modal dataset creation for federated learning with DICOM-structured reports
- Open Access
- 3 February 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (3) , 485-495
Multi-modal dataset creation for federated learning with DICOM-structured reports
Purpose Federated training is often challenging on heterogeneous datasets due to divergent data storage options, inconsistent naming schemes, varied annotation procedures, and disparities in label quality. This is particularly evident in the emerging multi-modal learning paradigms, where dataset harmonization including a uniform data representation and filtering options are of paramount importance. Methods DICOM-structured reports enable the standardized linkage of arbitrary information beyond the imaging domain and can be used within Python deep learning pipelines with . Building on this, we developed an open platform for data integration with interactive filtering capabilities, thereby simplifying the process of creation of patient cohorts over several sites with consistent multi-modal data. Results In this study, we extend our prior work by showing its applicability to more and divergent data types, as well as streamlining datasets for federated training within an established consortium of eight university hospitals in Germany. We prove its concurrent filtering ability by creating harmonized multi-modal datasets across all locations for predicting the outcome after minimally invasive heart valve replacement. The data include imaging and waveform data (i.e., computed tomography images, electrocardiography scans) as well as annotations (i.e., calcification segmentations, and pointsets), and metadata (i.e., prostheses and pacemaker dependency). Conclusion Structured reports bridge the traditional gap between imaging systems and information systems. Utilizing the inherent DICOM reference system arbitrary data types can be queried concurrently to create meaningful cohorts for multi-centric data analysis. The graphical interface as well as example structured report templates are available at https://github.com/Cardio-AI/fl-multi-modal-dataset-creation.
- 3 February 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (3) , 485-495
Open AccessMulti-modal dataset creation for federated learning with DICOM-structured reports
Purpose Federated training is often challenging on heterogeneous datasets due to divergent data storage options, inconsistent naming schemes, varied annotation procedures, and disparities in label quality. This is particularly evident in the emerging multi-modal learning paradigms, where dataset harmonization including a uniform data representation and filtering options are of paramount importance. Methods DICOM-structured reports enable the standardized linkage of arbitrary information beyond the imaging domain and can be used within Python deep learning pipelines with . Building on this, we developed an open platform for data integration with interactive filtering capabilities, thereby simplifying the process of creation of patient cohorts over several sites with consistent multi-modal data. Results In this study, we extend our prior work by showing its applicability to more and divergent data types, as well as streamlining datasets for federated training within an established consortium of eight university hospitals in Germany. We prove its concurrent filtering ability by creating harmonized multi-modal datasets across all locations for predicting the outcome after minimally invasive heart valve replacement. The data include imaging and waveform data (i.e., computed tomography images, electrocardiography scans) as well as annotations (i.e., calcification segmentations, and pointsets), and metadata (i.e., prostheses and pacemaker dependency). Conclusion Structured reports bridge the traditional gap between imaging systems and information systems. Utilizing the inherent DICOM reference system arbitrary data types can be queried concurrently to create meaningful cohorts for multi-centric data analysis. The graphical interface as well as example structured report templates are available at https://github.com/Cardio-AI/fl-multi-modal-dataset-creation.
- Open Access
- 4 May 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (6) , 1109-1118
Comparative evaluation of three commercially available markerless depth sensors for close-range use in surgical simulation
Purpose: Minimally invasive surgeries have restricted surgical ports, demanding a high skill level from the surgeon. Surgical simulation potentially reduces this steep learning curve and additionally provides quantitative feedback. Markerless depth sensors show great promise for quantification, but most such sensors are not designed for accurate reconstruction of complex anatomical forms in close-range. Methods: This work compares three commercially available depth sensors, namely the Intel D405, D415, and the Stereolabs Zed-Mini in the range of 12–20 cm, for use in surgical simulation. Three environments are designed that closely mimic surgical simulation, comprising planar surfaces, rigid objects, and mitral valve models of silicone and realistic porcine tissue. The cameras are evaluated on Z-accuracy, temporal noise, fill rate, checker distance, point cloud comparisons, and visual inspection of surgical scenes, across several camera settings. Results: The Intel cameras show sub-mm accuracy in most static environments. The D415 fails in reconstructing valve models, while the Zed-Mini provides lesser temporal noise and higher fill rate. The D405 could reconstruct anatomical structures like the mitral valve leaflet and a ring prosthesis, but performs poorly for reflective surfaces like surgical tools and thin structures like sutures. Conclusion: If a high temporal resolution is needed and lower spatial resolution is acceptable, the Zed-Mini is the best choice, whereas the Intel D405 is the most suited for close-range applications. The D405 shows potential for applications like deformable registration of surfaces, but is not yet suitable for applications like real-time tool tracking or surgical skill assessment.
- 4 May 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (6) , 1109-1118
Open AccessComparative evaluation of three commercially available markerless depth sensors for close-range use in surgical simulation
Purpose: Minimally invasive surgeries have restricted surgical ports, demanding a high skill level from the surgeon. Surgical simulation potentially reduces this steep learning curve and additionally provides quantitative feedback. Markerless depth sensors show great promise for quantification, but most such sensors are not designed for accurate reconstruction of complex anatomical forms in close-range. Methods: This work compares three commercially available depth sensors, namely the Intel D405, D415, and the Stereolabs Zed-Mini in the range of 12–20 cm, for use in surgical simulation. Three environments are designed that closely mimic surgical simulation, comprising planar surfaces, rigid objects, and mitral valve models of silicone and realistic porcine tissue. The cameras are evaluated on Z-accuracy, temporal noise, fill rate, checker distance, point cloud comparisons, and visual inspection of surgical scenes, across several camera settings. Results: The Intel cameras show sub-mm accuracy in most static environments. The D415 fails in reconstructing valve models, while the Zed-Mini provides lesser temporal noise and higher fill rate. The D405 could reconstruct anatomical structures like the mitral valve leaflet and a ring prosthesis, but performs poorly for reflective surfaces like surgical tools and thin structures like sutures. Conclusion: If a high temporal resolution is needed and lower spatial resolution is acceptable, the Zed-Mini is the best choice, whereas the Intel D405 is the most suited for close-range applications. The D405 shows potential for applications like deformable registration of surfaces, but is not yet suitable for applications like real-time tool tracking or surgical skill assessment.