Hasti Nourzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hasti Nourzadeh has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Humberto Cabrera
MLab, STI Unit, The Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, 34151 Trieste, Italy
1 shared publication - Maria Liz Crespo
The Abdus Salam International Centre for Theoretical Physics
1 shared publication - Maryam Lotfi
Department of Physics, Shahid Beheshti University 1 , Evin, Tehran 19839-69411, Iran
1 shared publication - Masoomeh Dashtdar
Shahid Beheshti University
1 shared publication
Latest Publications
- Open Access
- 1 May 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (5)
The phase range extension and accuracy improvement in Fresnel biprism-based digital holography microscopy
We report a highly stable and affordable dual-wavelength digital holographic microscopy system based on common-path geometry. A Fresnel biprism is used to create an off-axis geometry, and two diode laser sources with different wavelengths λ1 = 532 nm and λ2 = 650 nm generate the dual-wavelength compound hologram. In order to extend the measurement range, the phase distribution is obtained using a synthetic wavelength Λ1 = 2930.5 nm. Furthermore, to improve the system's temporal stability and reduce speckle noise, a shorter wavelength (Λ2 = 292.5 nm) is used. The feasibility of the proposed configuration is validated by the experimental results obtained with Molybdenum trioxide, Paramecium, and red blood cell specimens.
- 1 May 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (5)
Open AccessThe phase range extension and accuracy improvement in Fresnel biprism-based digital holography microscopy
We report a highly stable and affordable dual-wavelength digital holographic microscopy system based on common-path geometry. A Fresnel biprism is used to create an off-axis geometry, and two diode laser sources with different wavelengths λ1 = 532 nm and λ2 = 650 nm generate the dual-wavelength compound hologram. In order to extend the measurement range, the phase distribution is obtained using a synthetic wavelength Λ1 = 2930.5 nm. Furthermore, to improve the system's temporal stability and reduce speckle noise, a shorter wavelength (Λ2 = 292.5 nm) is used. The feasibility of the proposed configuration is validated by the experimental results obtained with Molybdenum trioxide, Paramecium, and red blood cell specimens.