Yoshitake Nakayama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yoshitake Nakayama has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Hiroko Nakaoka
Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan
3 shared publications - Kohki Takaguchi
Department of Healthy Cities and Built Environment, Chiba University, Chiba, Japan
3 shared publications - Kayo Tsumura
Center for Preventive Medical Sciences, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba-shi, Chiba, 263-8522, Japan
2 shared publications - Norimichi Suzuki
Center for Preventive Medical Sciences, Chiba University, Chiba 263-8522, Japan
2 shared publications - Akifumi Eguchi
Department of Sustainable Health Science, Chiba University Center for Preventive Medical Sciences, Chiba, Japan
1 shared publication Chisato Mori
Center for Preventive Medical Sciences, Chiba University, Chiba, Japan
1 shared publication
Latest Publications
- Open Access
The Relationship Between Ventilation and Building-Related Symptoms in Modern High-Performance Japanese Houses: A Cross-Sectional Study Using Building-Specification Data
Ventilation plays a key role in maintaining indoor air quality and reducing building-related symptoms (BRSs). Although prior studies suggest that ventilation volume and system type may influence BRSs, few have examined their combined effects in residential settings. This cross-sectional study investigated associations between ventilation volume, system type, and BRSs among 3970 residents of newly built detached houses in Japan. Data were collected in two waves in 2023, and the ventilation volume per floor area and per person was calculated from building specifications. BRSs were assessed using the MM040EA Sick House Syndrome questionnaire and analyzed using binary logistic regression stratified by system type. In air supply and exhaust systems, higher ventilation volume per person was linked to a lower prevalence of general symptoms (OR = 0.46). In exhaust-only systems, greater ventilation volume was positively associated with mucosal irritation symptoms (OR = 1.60). These findings highlight the complex relationship between ventilation and health and emphasize the importance of system type. Although air quality parameters were not measured directly, the results provide evidence based on building specifications, thereby offering insight to refine building codes, guide post-occupancy assessments, and inform preventive public health policy.
Open AccessThe Relationship Between Ventilation and Building-Related Symptoms in Modern High-Performance Japanese Houses: A Cross-Sectional Study Using Building-Specification Data
Ventilation plays a key role in maintaining indoor air quality and reducing building-related symptoms (BRSs). Although prior studies suggest that ventilation volume and system type may influence BRSs, few have examined their combined effects in residential settings. This cross-sectional study investigated associations between ventilation volume, system type, and BRSs among 3970 residents of newly built detached houses in Japan. Data were collected in two waves in 2023, and the ventilation volume per floor area and per person was calculated from building specifications. BRSs were assessed using the MM040EA Sick House Syndrome questionnaire and analyzed using binary logistic regression stratified by system type. In air supply and exhaust systems, higher ventilation volume per person was linked to a lower prevalence of general symptoms (OR = 0.46). In exhaust-only systems, greater ventilation volume was positively associated with mucosal irritation symptoms (OR = 1.60). These findings highlight the complex relationship between ventilation and health and emphasize the importance of system type. Although air quality parameters were not measured directly, the results provide evidence based on building specifications, thereby offering insight to refine building codes, guide post-occupancy assessments, and inform preventive public health policy.
- Open Access
- 4 May 2023
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (19) , 8532-8546
Sampling method for house dust using a mop and determination of OPFRs, phthalates, and alternative plasticisers in house dust
Semi-volatile organic compounds (SVOCs), such as phthalates and organophosphate flame retardants (OPFRs), are used in plastic products and electrical and electronic applications as plasticisers or flame retardants. There has been a growing concern that exposure to SVOCs can have an adverse impact on human health. Several large-scale epidemiological studies employ the sampling of house dust using household vacuum cleaners as the standard method. However, in this method, house dust samples might be contaminated by flame retardants and plasticisers because of the presence of these chemicals in the plastic materials of cleaners. Therefore, this study aimed to develop a low-cost, easy-to-distribute sampling method to collect house dust using a mop and analyse OPFRs, phthalate esters, and alternative plasticisers in house dust. Our findings show that the proposed mop sampling method can be easily distributable and lower contamination from a sampling tool. Moreover, the proposed house dust sampling method is extremely useful for a large-scale survey such as a cohort study.
- 4 May 2023
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (19) , 8532-8546
Open AccessSampling method for house dust using a mop and determination of OPFRs, phthalates, and alternative plasticisers in house dust
Semi-volatile organic compounds (SVOCs), such as phthalates and organophosphate flame retardants (OPFRs), are used in plastic products and electrical and electronic applications as plasticisers or flame retardants. There has been a growing concern that exposure to SVOCs can have an adverse impact on human health. Several large-scale epidemiological studies employ the sampling of house dust using household vacuum cleaners as the standard method. However, in this method, house dust samples might be contaminated by flame retardants and plasticisers because of the presence of these chemicals in the plastic materials of cleaners. Therefore, this study aimed to develop a low-cost, easy-to-distribute sampling method to collect house dust using a mop and analyse OPFRs, phthalate esters, and alternative plasticisers in house dust. Our findings show that the proposed mop sampling method can be easily distributable and lower contamination from a sampling tool. Moreover, the proposed house dust sampling method is extremely useful for a large-scale survey such as a cohort study.
- 6 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 501-502
A Study on Emotion Estimation by Non-contact Sensing for Telework Life
In this study, we construct a system for estimating emotional states by sensing indoor environments for teleworking life, and conducted experimental evaluations. As a result, our method can estimate emotions with more than 80% accuracy by using multiple types of sensors and Random Forest or Gradient Boosting Decision Tree as machine learning models.
- 6 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 501-502
A Study on Emotion Estimation by Non-contact Sensing for Telework Life
In this study, we construct a system for estimating emotional states by sensing indoor environments for teleworking life, and conducted experimental evaluations. As a result, our method can estimate emotions with more than 80% accuracy by using multiple types of sensors and Random Forest or Gradient Boosting Decision Tree as machine learning models.