Tanzila Noushin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tanzila Noushin has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Shawana Tabassum
The University of Texas at Tyler,Electrical Engineering,Tyler,TX,USA
7 shared publications- Shawana Tabassum
The University of Texas at Tyler
5 shared publications - Jinwon Jeong
Baylor University
3 shared publications Nafize Ishtiaque Hossain
Department of Electrical Engineering, The University of Texas at Tyler, Tyler, TX, USA
3 shared publications- Jeong-Bong Lee
Department of Electrical and Computer Engineering, Baylor University, Waco, TX 76798, USA
2 shared publications - Muhammad Luqman Haider
The University of Texas at Dallas
2 shared publications
Latest Publications
- 1 September 2026
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Letters
- Vol.Ā 10 Ā (9) , 2505004
A Laser-Induced Graphene-Based Flexible Strain Sensor Using Tri-Ethylene Glycol/PDMS Composite
- 1 September 2026
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Letters
- Vol.Ā 10 Ā (9) , 2505004
A Laser-Induced Graphene-Based Flexible Strain Sensor Using Tri-Ethylene Glycol/PDMS Composite
- Open Access
- 19 July 2026
- Published byĀ ElsevierĀ inĀ SSRN Electronic Journal
Toward Non-Invasive Diagnosis of Interstitial Cystitis: A Single-Chip Multiplexed Urine Biosensor for VEGF and IL-1α Detection
Levated urinary levels of interleukin-1 α (IL-1α) and vascular endothelial growth factor (VEGF) have been reported in patients with interstitial cystitis (IC) relative to other inflammatory bladder diseases, highlighting their potential as biomarkers for disease diagnosis and therapeutic monitoring. No compact platform for the concurrent detection of these two IC-associated biomarkers in a urine matrix has been reported to date. Here, we present a single-chip multiplexed electrochemical biosensor for the simultaneous quantification of IL-1α and VEGF in artificial urine. The device was fabricated on a glass substrate using a combination of e-beam evaporation and screen-printing techniques. It exhibited dynamic detection ranges of 1ā1,000 pg/mL for VEGF and 0.01ā100 pg/mL for IL-1α, with limits of detection of 10 fg/mL and 1 fg/mL and response times of 20 s and 15 s, respectively. The biosensor demonstrated reproducibility with a relative standard deviation (RSD) below 3%, selectivity against common urinary interferents, including 0.5 mM glucose and 80 nM nitrite, and no measurable cross-reactivity between sensing channels. Repeatability testing across four consecutive calibration runs yielded an RSD below 0.1%. The platform further exhibited reversible responses over four ascendingādescending concentration cycles, minimal signal drift during 12 h of continuous operation (overall RSD ā 0.6%), and stable performance over seven days (overall RSD = 1%). The capability to quantitatively monitor IL-1α and VEGF in real time using a single analytical platform supports its potential application in IC diagnosis, disease progression monitoring, and evaluation of therapeutic response at the point of care.
- 19 July 2026
- Published byĀ ElsevierĀ inĀ SSRN Electronic Journal
Open AccessToward Non-Invasive Diagnosis of Interstitial Cystitis: A Single-Chip Multiplexed Urine Biosensor for VEGF and IL-1α Detection
Levated urinary levels of interleukin-1 α (IL-1α) and vascular endothelial growth factor (VEGF) have been reported in patients with interstitial cystitis (IC) relative to other inflammatory bladder diseases, highlighting their potential as biomarkers for disease diagnosis and therapeutic monitoring. No compact platform for the concurrent detection of these two IC-associated biomarkers in a urine matrix has been reported to date. Here, we present a single-chip multiplexed electrochemical biosensor for the simultaneous quantification of IL-1α and VEGF in artificial urine. The device was fabricated on a glass substrate using a combination of e-beam evaporation and screen-printing techniques. It exhibited dynamic detection ranges of 1ā1,000 pg/mL for VEGF and 0.01ā100 pg/mL for IL-1α, with limits of detection of 10 fg/mL and 1 fg/mL and response times of 20 s and 15 s, respectively. The biosensor demonstrated reproducibility with a relative standard deviation (RSD) below 3%, selectivity against common urinary interferents, including 0.5 mM glucose and 80 nM nitrite, and no measurable cross-reactivity between sensing channels. Repeatability testing across four consecutive calibration runs yielded an RSD below 0.1%. The platform further exhibited reversible responses over four ascendingādescending concentration cycles, minimal signal drift during 12 h of continuous operation (overall RSD ā 0.6%), and stable performance over seven days (overall RSD = 1%). The capability to quantitatively monitor IL-1α and VEGF in real time using a single analytical platform supports its potential application in IC diagnosis, disease progression monitoring, and evaluation of therapeutic response at the point of care.
- 9 September 2025
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Letters
- Vol.Ā 9 Ā (10) , 1-4
Dual-Mode Detection of Urinary Chemokine and Ion Imbalance of BPS/IC Patients Toward Therapeutic Efficacy Assessment
Bladder pain syndrome/interstitial cystitis (BPS/IC) is a chronic urological condition characterized by pelvic pain and urinary urgency, often misdiagnosed due to symptom overlap with other analogous disorders. The absence of specific, noninvasive biomarkers complicates its diagnosis and hinders effective monitoring of disease progression and therapeutic response. C-C motif chemokine ligand 5 (CCL5) is recognized as a potential inflammatory biomarker for BPS/IC, while urinary potassium (K+) levels reflect epithelial barrier dysfunction. In this letter, we present a novel screen-printed, low-cost, and rapid electrochemical sensor for simultaneous point-of-care detection of CCL5 and K+ in urine samples. The sensor employs immunosensing and ion-selective membrane strategies to achieve excellent sensitivity, selectivity, and operational stability, having a low detection limit of 60 fg/mL and 80 pM for CCL5 and K+ ion sensing electrodes. The dual-detection approach offers valuable insights into both inflammatory status and urothelial integrity, holds promise for early diagnosis and therapeutic strategy with improved patient stratification, and real-time personalized monitoring in BPS/IC.
- 9 September 2025
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Letters
- Vol.Ā 9 Ā (10) , 1-4
Dual-Mode Detection of Urinary Chemokine and Ion Imbalance of BPS/IC Patients Toward Therapeutic Efficacy Assessment
Bladder pain syndrome/interstitial cystitis (BPS/IC) is a chronic urological condition characterized by pelvic pain and urinary urgency, often misdiagnosed due to symptom overlap with other analogous disorders. The absence of specific, noninvasive biomarkers complicates its diagnosis and hinders effective monitoring of disease progression and therapeutic response. C-C motif chemokine ligand 5 (CCL5) is recognized as a potential inflammatory biomarker for BPS/IC, while urinary potassium (K+) levels reflect epithelial barrier dysfunction. In this letter, we present a novel screen-printed, low-cost, and rapid electrochemical sensor for simultaneous point-of-care detection of CCL5 and K+ in urine samples. The sensor employs immunosensing and ion-selective membrane strategies to achieve excellent sensitivity, selectivity, and operational stability, having a low detection limit of 60 fg/mL and 80 pM for CCL5 and K+ ion sensing electrodes. The dual-detection approach offers valuable insights into both inflammatory status and urothelial integrity, holds promise for early diagnosis and therapeutic strategy with improved patient stratification, and real-time personalized monitoring in BPS/IC.
- 31 October 2023
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Journal
- Vol.Ā 25 Ā (15) , 27777-27790
Tattoo-Like Flexible Ethylene Sensor for Plant Stress Monitoring in Real-Time
This paper presents a flexible tattoo sensor for real-time monitoring of gaseous ethylene released from plant leaves. To the best of our knowledge, this is the first reported plant tattoo sensor that can measure and monitor a plant hormone in situ . The tattoo sensor can be easily installed on leaves and removed when required using a stick-and-peel mechanism. Furthermore, temperature and humidity sensors were incorporated to correct the ethylene measurements based on the specific microclimate of the leaf. All sensors were chemiresistive in nature, causing variations in resistance as a result of changes in temperature, humidity, or ethylene. The ethylene sensor demonstrated a sensitivity of 0.6295 kΩ/ppm and a limit of detection of 0.13 ppm. The measurements were processed by an onboard data logger, transmitted wirelessly to the cloud, and accessed on a smartphone. Plants were subjected to multiple stressors, including water, temperature, and dark stressors, and the real-time ethylene measurements were recorded with the tattoo sensor. A statistically significant difference, characterized by p values less than 0.05, was observed between different types of stresses. Roll-to-roll fabrication of these tattoos will enable their large-scale implementation in greenhouses and agricultural fields.
- 31 October 2023
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Journal
- Vol.Ā 25 Ā (15) , 27777-27790
Tattoo-Like Flexible Ethylene Sensor for Plant Stress Monitoring in Real-Time
This paper presents a flexible tattoo sensor for real-time monitoring of gaseous ethylene released from plant leaves. To the best of our knowledge, this is the first reported plant tattoo sensor that can measure and monitor a plant hormone in situ . The tattoo sensor can be easily installed on leaves and removed when required using a stick-and-peel mechanism. Furthermore, temperature and humidity sensors were incorporated to correct the ethylene measurements based on the specific microclimate of the leaf. All sensors were chemiresistive in nature, causing variations in resistance as a result of changes in temperature, humidity, or ethylene. The ethylene sensor demonstrated a sensitivity of 0.6295 kΩ/ppm and a limit of detection of 0.13 ppm. The measurements were processed by an onboard data logger, transmitted wirelessly to the cloud, and accessed on a smartphone. Plants were subjected to multiple stressors, including water, temperature, and dark stressors, and the real-time ethylene measurements were recorded with the tattoo sensor. A statistically significant difference, characterized by p values less than 0.05, was observed between different types of stresses. Roll-to-roll fabrication of these tattoos will enable their large-scale implementation in greenhouses and agricultural fields.
- 29 October 2023
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Real-Time Monitoring of Inflammation in Metabolic Syndrome with Electrochemical Detection of Tyramine Level in Urine
This work reports on an innovative and cost-effective screen-printed biosensor, designed for rapid and realtime detection of tyramine levels in urine and continuous monitoring of metabolic syndrome in patients with diabetes mellitus and atherosclerotic cardiovascular disease at the point-of-care. Tyramine levels displayed a significant inverse correlation with various biomarkers of inflammation and cardiometabolic risk factors such as blood pressure and body mass index. In addition, a low level of tyramine has been found to be associated with the proinflammatory state in metabolic syndrome. The developed sensor exhibited remarkable electrocatalytic activity toward tyramine detection within two linear concentration range of 1ā500 nM, and 1ā200 μM, with limit-of-detection of 0.039 μM, and a response time of 14 seconds. With a remarkable sensitivity, reproducibility, and stability performance, this device possesses the potential to enable early diagnosis of severe clinical conditions associated with tyramine levels in urine and effectively monitor, manage, and ensure healthcare in any resource-limited settings.
- 29 October 2023
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Real-Time Monitoring of Inflammation in Metabolic Syndrome with Electrochemical Detection of Tyramine Level in Urine
This work reports on an innovative and cost-effective screen-printed biosensor, designed for rapid and realtime detection of tyramine levels in urine and continuous monitoring of metabolic syndrome in patients with diabetes mellitus and atherosclerotic cardiovascular disease at the point-of-care. Tyramine levels displayed a significant inverse correlation with various biomarkers of inflammation and cardiometabolic risk factors such as blood pressure and body mass index. In addition, a low level of tyramine has been found to be associated with the proinflammatory state in metabolic syndrome. The developed sensor exhibited remarkable electrocatalytic activity toward tyramine detection within two linear concentration range of 1ā500 nM, and 1ā200 μM, with limit-of-detection of 0.039 μM, and a response time of 14 seconds. With a remarkable sensitivity, reproducibility, and stability performance, this device possesses the potential to enable early diagnosis of severe clinical conditions associated with tyramine levels in urine and effectively monitor, manage, and ensure healthcare in any resource-limited settings.
- Top Cited PapersOpen Access
Road Map of Semiconductor Metal-Oxide-Based Sensors: A Review
Identifying disease biomarkers and detecting hazardous, explosive, flammable, and polluting gases and chemicals with extremely sensitive and selective sensor devices remains a challenging and time-consuming research challenge. Due to their exceptional characteristics, semiconducting metal oxides (SMOxs) have received a lot of attention in terms of the development of various types of sensors in recent years. The key performance indicators of SMOx-based sensors are their sensitivity, selectivity, recovery time, and steady response over time. SMOx-based sensors are discussed in this review based on their different properties. Surface properties of the functional material, such as its (nano)structure, morphology, and crystallinity, greatly influence sensor performance. A few examples of the complicated and poorly understood processes involved in SMOx sensing systems are adsorption and chemisorption, charge transfers, and oxygen migration. The future prospects of SMOx-based gas sensors, chemical sensors, and biological sensors are also discussed.
Top Cited PapersOpen AccessRoad Map of Semiconductor Metal-Oxide-Based Sensors: A Review
Identifying disease biomarkers and detecting hazardous, explosive, flammable, and polluting gases and chemicals with extremely sensitive and selective sensor devices remains a challenging and time-consuming research challenge. Due to their exceptional characteristics, semiconducting metal oxides (SMOxs) have received a lot of attention in terms of the development of various types of sensors in recent years. The key performance indicators of SMOx-based sensors are their sensitivity, selectivity, recovery time, and steady response over time. SMOx-based sensors are discussed in this review based on their different properties. Surface properties of the functional material, such as its (nano)structure, morphology, and crystallinity, greatly influence sensor performance. A few examples of the complicated and poorly understood processes involved in SMOx sensing systems are adsorption and chemisorption, charge transfers, and oxygen migration. The future prospects of SMOx-based gas sensors, chemical sensors, and biological sensors are also discussed.
- 5 May 2023
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Journal
- Vol.Ā 24 Ā (6) , 7253-7263
Kirigami-Shaped Dual-Functional Strain and Temperature Sensors for Monitoring Body Movements and Hyperthermia Toward Physiotherapy Applications
Multifunctional sensors find widespread applications in wearable healthcare, Internet-of-Things, environmental monitoring, and human-machine interactions, yet they suffer from reduced stretchability, durability, wearability, and enhanced signal crosstalk. This work presents a new kirigami-shaped dual-functional patch that integrates both strain and temperature sensors in a single platform. The kirigami architecture allows out-of-plane deformation of the sensors enabling them to conform to different body parts. The sensing regions are functionalized with gold nanoparticle-decorated multi-walled carbon nanotubes that provide highly sensitive and repeatable performance. The strain sensor has a gauge factor of around 220 at 0.12% bending strain and the temperature sensor shows a sensitivity of 0.0278 kΩ °C -1 . Additionally, the sensor demonstrates an ultra-high stretchability for an applied tensile strain of up to 180%. The sensors can precisely monitor the dynamic bending of different joints in the body and temperature as well as decouple the strain and temperature measurements in response to dual stimuli. Furthermore, the sensors are interfaced with an Internet-of-Things platform that allows wireless transmission of body motion and temperature measurements to the cloud. The versatile nature of the sensing patch holds great promise for continuous monitoring of the progress in physiotherapy so that recovery can be tracked in real-time and appropriate intervention measures can be applied.
- 5 May 2023
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Journal
- Vol.Ā 24 Ā (6) , 7253-7263
Kirigami-Shaped Dual-Functional Strain and Temperature Sensors for Monitoring Body Movements and Hyperthermia Toward Physiotherapy Applications
Multifunctional sensors find widespread applications in wearable healthcare, Internet-of-Things, environmental monitoring, and human-machine interactions, yet they suffer from reduced stretchability, durability, wearability, and enhanced signal crosstalk. This work presents a new kirigami-shaped dual-functional patch that integrates both strain and temperature sensors in a single platform. The kirigami architecture allows out-of-plane deformation of the sensors enabling them to conform to different body parts. The sensing regions are functionalized with gold nanoparticle-decorated multi-walled carbon nanotubes that provide highly sensitive and repeatable performance. The strain sensor has a gauge factor of around 220 at 0.12% bending strain and the temperature sensor shows a sensitivity of 0.0278 kΩ °C -1 . Additionally, the sensor demonstrates an ultra-high stretchability for an applied tensile strain of up to 180%. The sensors can precisely monitor the dynamic bending of different joints in the body and temperature as well as decouple the strain and temperature measurements in response to dual stimuli. Furthermore, the sensors are interfaced with an Internet-of-Things platform that allows wireless transmission of body motion and temperature measurements to the cloud. The versatile nature of the sensing patch holds great promise for continuous monitoring of the progress in physiotherapy so that recovery can be tracked in real-time and appropriate intervention measures can be applied.
- 30 October 2022
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Kirigami-patterned IoT-enabled Smart Anklet to Aid Physiotherapy of Patients with Foot Injury
Flexible strain sensors have great potential in wearable applications, yet it is challenging to achieve the desired sensitivity, stretchability, reversibility, durability, and skin conformity. This work reports a kirigami- structured strain sensor in the shape of an anklet, which was modified with gold decorated multi-walled carbon nanotubes and passivated with ecoflex. The proposed sensor depicted an ultra-high stretchability for an applied strain up to 180%. The extremely high sensitivity and the Internet-of- Things interface enable the real-time monitoring of ankle strain of injured patients undergoing rehabilitation.
- 30 October 2022
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Kirigami-patterned IoT-enabled Smart Anklet to Aid Physiotherapy of Patients with Foot Injury
Flexible strain sensors have great potential in wearable applications, yet it is challenging to achieve the desired sensitivity, stretchability, reversibility, durability, and skin conformity. This work reports a kirigami- structured strain sensor in the shape of an anklet, which was modified with gold decorated multi-walled carbon nanotubes and passivated with ecoflex. The proposed sensor depicted an ultra-high stretchability for an applied strain up to 180%. The extremely high sensitivity and the Internet-of- Things interface enable the real-time monitoring of ankle strain of injured patients undergoing rehabilitation.
- 29 September 2022
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Letters
- Vol.Ā 6 Ā (10) , 1-4
Flexible Sensor Suite Integrated Into Textile for Calcium Ion and Fall Detection
Studies show that excessive loss of sweat calcium is associated with deterioration of bone mineral density in young athletes during vigorous intensity exercise. Low levels of bone mineral density cause a higher risk of bone fracture, meaning a single fall can be devastating. This work reports a smart compression sock that detects calcium levels in sweat and simultaneously scans for a fall and alerts the user accordingly. The sock is washable, and the device is removable using a Velcro pad attached to the inner side of the sock. An electrochemical sensor detects the calcium levels, while a tri-axial accelerometer detects a fall event. When paired with a fall detection algorithm, the accelerometer quickly determines if a fall has occurred based on the differential acceleration. The calcium and fall detection units are interfaced with a microcontroller that sends the information to a user interface platform via the Blynk IoT cloud. If the calcium level is above/below the critical value or a fall is detected, a notification along with the user's GPS location is sent to authorized emergency contacts so that the user can be attended immediately. In addition, the electronic components were soldered onto a flexible printed circuit board. Such an integrated flexible system will allow continuous monitoring of athletes to drive just-in-time intervention.
- 29 September 2022
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Sensors Letters
- Vol.Ā 6 Ā (10) , 1-4
Flexible Sensor Suite Integrated Into Textile for Calcium Ion and Fall Detection
Studies show that excessive loss of sweat calcium is associated with deterioration of bone mineral density in young athletes during vigorous intensity exercise. Low levels of bone mineral density cause a higher risk of bone fracture, meaning a single fall can be devastating. This work reports a smart compression sock that detects calcium levels in sweat and simultaneously scans for a fall and alerts the user accordingly. The sock is washable, and the device is removable using a Velcro pad attached to the inner side of the sock. An electrochemical sensor detects the calcium levels, while a tri-axial accelerometer detects a fall event. When paired with a fall detection algorithm, the accelerometer quickly determines if a fall has occurred based on the differential acceleration. The calcium and fall detection units are interfaced with a microcontroller that sends the information to a user interface platform via the Blynk IoT cloud. If the calcium level is above/below the critical value or a fall is detected, a notification along with the user's GPS location is sent to authorized emergency contacts so that the user can be attended immediately. In addition, the electronic components were soldered onto a flexible printed circuit board. Such an integrated flexible system will allow continuous monitoring of athletes to drive just-in-time intervention.
- 17 June 2022
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
IoT based Smart Helmet for Automated and Multi-parametric Monitoring of Underground Minersā Health Hazards
Safety has always been a concern for underground miners or construction site workers in general. The recent growth of the Internet of Things (IoT) and its applications has paved the way to monitor and track the safety of workers in real-time. This paper reports the design and development of an IoT-based smart helmet for real-time monitoring of the health and safety of workers in underground mines. The smart helmet was comprised of an array of ambient and flexible body sensors, which were wirelessly connected to the cloud via the LoRaWAN protocol, thereby establishing communication with the control room. The effectiveness and performance of this smart helmet were tested and analyzed.
- 17 June 2022
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
IoT based Smart Helmet for Automated and Multi-parametric Monitoring of Underground Minersā Health Hazards
Safety has always been a concern for underground miners or construction site workers in general. The recent growth of the Internet of Things (IoT) and its applications has paved the way to monitor and track the safety of workers in real-time. This paper reports the design and development of an IoT-based smart helmet for real-time monitoring of the health and safety of workers in underground mines. The smart helmet was comprised of an array of ambient and flexible body sensors, which were wirelessly connected to the cloud via the LoRaWAN protocol, thereby establishing communication with the control room. The effectiveness and performance of this smart helmet were tested and analyzed.