Geovanna Maribel Herrera Herrera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Geovanna Maribel Herrera Herrera has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Katherine Pamela Valencia Pasquel
Hospital Pediátrico Baca Ortiz. Quito, Ecuador
1 shared publication - María Gabriela Romero Rodríguez
Universidad Nacional de Chimborazo, Riobamba, Ecuador
1 shared publication - Robinson Adrián Rumiguano Jiménez
Servicio de Fisioterapia Intensiva, Centro cardiorrespiratorio Resphyairway. Quito, Ecuador
1 shared publication - Stalin Javier Caiza Lema
Universidad Técnica de Ambato
1 shared publication - Victoria Estefanía Espín Pastor
Universidad Técnica de Ambato, Facultad ciencias de la salud, Carrera de Fisioterapia Ambato, Ecuador
1 shared publication
Latest Publications
- Open Access
- 26 April 2023
- Published by Salud, Ciencia y Tecnologia in Salud, Ciencia y Tecnología
- Vol. 3, 331
Relationship of static and dynamic inspiratory muscle strength
Background: the non-invasive evaluation of the inspiratory muscles strength makes it possible to detect their weakness globally. The use of digital or aneroid manometers to determine the inspiratory force can be taken by a static technique, known as pymometry, obtaining the maximum inspiratory pressure. However, equipment such as PowerBreathe is also used to obtain the strength index, which is considered a dynamic technique. Methods: the present work is a cross-sectional cohort study, focused on analyzing the inspiratory muscle force in a static and dynamic way in healthy subjects, using a non-clinical digital manometer Ht - 18909 compared with a PowerBreathe equipment. The study was conducted in 23 healthy volunteer patients with a mean age of 19 years. Results: Inspiratory force measurements for both instruments reached a mean of 57,5 cmH2O and 55,3 cmH2O (SD 16,38 – 14,91) when taken with manometry and PowerBreathe equipment respectively, the correlation by calculating of the ICC with a reliability of 95 %, was 0,87, having a high level of agreement or similarity between the measures. Conclusions: It was concluded that there are no significant differences when measuring the inspiratory force when using both devices that estimate the force statically and dynamically
- 26 April 2023
- Published by Salud, Ciencia y Tecnologia in Salud, Ciencia y Tecnología
- Vol. 3, 331
Open AccessRelationship of static and dynamic inspiratory muscle strength
Background: the non-invasive evaluation of the inspiratory muscles strength makes it possible to detect their weakness globally. The use of digital or aneroid manometers to determine the inspiratory force can be taken by a static technique, known as pymometry, obtaining the maximum inspiratory pressure. However, equipment such as PowerBreathe is also used to obtain the strength index, which is considered a dynamic technique. Methods: the present work is a cross-sectional cohort study, focused on analyzing the inspiratory muscle force in a static and dynamic way in healthy subjects, using a non-clinical digital manometer Ht - 18909 compared with a PowerBreathe equipment. The study was conducted in 23 healthy volunteer patients with a mean age of 19 years. Results: Inspiratory force measurements for both instruments reached a mean of 57,5 cmH2O and 55,3 cmH2O (SD 16,38 – 14,91) when taken with manometry and PowerBreathe equipment respectively, the correlation by calculating of the ICC with a reliability of 95 %, was 0,87, having a high level of agreement or similarity between the measures. Conclusions: It was concluded that there are no significant differences when measuring the inspiratory force when using both devices that estimate the force statically and dynamically