Thanh-Trung Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thanh-Trung Nguyen has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Ngoc-Tam Bui
Innovative Global Program, Shibaura Institute of Technology, Saitama, Japan
4 shared publications Tam Bui
Shibaura Institute of Technology
4 shared publicationsHa Pham
Hanoi University of Industry
3 shared publicationsHuy Nguyen
Ha Noi University of Science and Technology
2 shared publicationsNgoc-Linh Tao
School of Mechanical Engineering, Hanoi University of Science and Technology, VIETNAM
2 shared publicationsQuang M. Ha
Hanoi University of Science and Technology
2 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by Frontiers Media SA in Frontiers in Sports and Active Living
- Vol. 8, 1973846
A quaternion-based, transmission-scheduled multi-IMU system for low-cost lower-limb joint-angle measurement: bench validation against an encoder up to the Cardan singularity, and wireless protocol benchmarking
Wearable inertial measurement unit (IMU) networks are an affordable alternative to optical motion capture for lower-limb measurement in sport, physical activity, and rehabilitation outside the laboratory, but two problems limit their kinematic signal: the reference-frame dependence of joint angles formed by differencing Euler angles from separate sensors, and frame-level desynchronisation caused by unscheduled wireless transmission. We developed and evaluated a four-node wireless IMU system addressing both. Joint angles were computed from the relative orientation quaternion between adjacent segments. This removes the dependence on a common global heading, but a singularity re-enters when an angle sequence is extracted, and here the reported joint angle is itself that singular rotation, reaching 88.4 deg in magnitude at end-range. Transport was reorganised as a deterministic, master-driven slotted protocol over ESP-NOW: a hardware-timer broadcast trigger carried a shared sequence number and timestamp, each node replied after a fixed per-node slot delay of 1.2 + 2.5k ms, and serialisation was moved out of the receive callback. Joint-angle accuracy was validated on a mechanical rig against a 600 pulses-per-revolution encoder; no human data were collected. Communication was benchmarked over paired 300 s recordings of the proposed protocol and a queue-based baseline. Against the encoder, root-mean-square error was 1.12, 0.79, and 0.86 deg for the three IMU pairs, with a bias of +0.70, +0.52, and +0.46 deg and 95% limits of agreement no wider than 3.4 deg. Cross-correlation placed the end-to-end latency at 44 ms; compensating for it left the bias unchanged and halved the standard deviation of the difference. Relative to the baseline, the proposed protocol raised the complete-frame rate from 97.20% to 99.99% while increasing the trigger rate from 20 to 50 Hz, cut duplicate packets from 16.13% to 0.31%, and reduced median per-second latency jitter from 26.5–35.5 ms to 3.4–4.9 ms. Scheduling, however, acts on transmission, not acquisition: the nodes sample on free-running loops, and their acquisition instants within a frame differed by a median of 9.0 ms. The transport layer is therefore deterministic and the bench estimation chain accurate, while acquisition-time skew limits joint-angle measurement during fast movement.
- 9 November 2026
- Published by Frontiers Media SA in Frontiers in Sports and Active Living
- Vol. 8, 1973846
Open AccessA quaternion-based, transmission-scheduled multi-IMU system for low-cost lower-limb joint-angle measurement: bench validation against an encoder up to the Cardan singularity, and wireless protocol benchmarking
Wearable inertial measurement unit (IMU) networks are an affordable alternative to optical motion capture for lower-limb measurement in sport, physical activity, and rehabilitation outside the laboratory, but two problems limit their kinematic signal: the reference-frame dependence of joint angles formed by differencing Euler angles from separate sensors, and frame-level desynchronisation caused by unscheduled wireless transmission. We developed and evaluated a four-node wireless IMU system addressing both. Joint angles were computed from the relative orientation quaternion between adjacent segments. This removes the dependence on a common global heading, but a singularity re-enters when an angle sequence is extracted, and here the reported joint angle is itself that singular rotation, reaching 88.4 deg in magnitude at end-range. Transport was reorganised as a deterministic, master-driven slotted protocol over ESP-NOW: a hardware-timer broadcast trigger carried a shared sequence number and timestamp, each node replied after a fixed per-node slot delay of 1.2 + 2.5k ms, and serialisation was moved out of the receive callback. Joint-angle accuracy was validated on a mechanical rig against a 600 pulses-per-revolution encoder; no human data were collected. Communication was benchmarked over paired 300 s recordings of the proposed protocol and a queue-based baseline. Against the encoder, root-mean-square error was 1.12, 0.79, and 0.86 deg for the three IMU pairs, with a bias of +0.70, +0.52, and +0.46 deg and 95% limits of agreement no wider than 3.4 deg. Cross-correlation placed the end-to-end latency at 44 ms; compensating for it left the bias unchanged and halved the standard deviation of the difference. Relative to the baseline, the proposed protocol raised the complete-frame rate from 97.20% to 99.99% while increasing the trigger rate from 20 to 50 Hz, cut duplicate packets from 16.13% to 0.31%, and reduced median per-second latency jitter from 26.5–35.5 ms to 3.4–4.9 ms. Scheduling, however, acts on transmission, not acquisition: the nodes sample on free-running loops, and their acquisition instants within a frame differed by a median of 9.0 ms. The transport layer is therefore deterministic and the bench estimation chain accurate, while acquisition-time skew limits joint-angle measurement during fast movement.
- Open Access
- 30 January 2026
- Published by Wiley in Journal of Robotics
- Vol. 2026 (1)
Knowledge Frameworks in Lower Limb Rehabilitation Robots
With the increasing global incidence of strokes, the demand for the development of rehabilitation robots for poststroke patients is very high. However, the development of rehabilitation robots for poststroke patients is a complex issue. To effectively engage in research in this field, one needs to be equipped with a vast amount of knowledge related to biomechanics, medical treatment, robotic systems, and control systems. For new developers entering this field, it will be a significant challenge, requiring an understanding of various interdisciplinary areas. Therefore, the aim of this research is to systematically evaluate the interdisciplinary knowledge areas used in the development of lower limb rehabilitation robots for poststroke patients. This study will assess several fundamental areas of knowledge, including human biomechanics, anthropometry, stroke pathology, treatment methods, lower limb rehabilitation robotic systems, safety issues, and clinical trials for the system. Additionally, this research will discuss some potential development directions in this field. Through this study, essential knowledge content necessary for the development of lower limb rehabilitation robots will be provided.
- 30 January 2026
- Published by Wiley in Journal of Robotics
- Vol. 2026 (1)
Open AccessKnowledge Frameworks in Lower Limb Rehabilitation Robots
With the increasing global incidence of strokes, the demand for the development of rehabilitation robots for poststroke patients is very high. However, the development of rehabilitation robots for poststroke patients is a complex issue. To effectively engage in research in this field, one needs to be equipped with a vast amount of knowledge related to biomechanics, medical treatment, robotic systems, and control systems. For new developers entering this field, it will be a significant challenge, requiring an understanding of various interdisciplinary areas. Therefore, the aim of this research is to systematically evaluate the interdisciplinary knowledge areas used in the development of lower limb rehabilitation robots for poststroke patients. This study will assess several fundamental areas of knowledge, including human biomechanics, anthropometry, stroke pathology, treatment methods, lower limb rehabilitation robotic systems, safety issues, and clinical trials for the system. Additionally, this research will discuss some potential development directions in this field. Through this study, essential knowledge content necessary for the development of lower limb rehabilitation robots will be provided.
- 5 October 2025
- Published by Springer Nature
- p. 391-401
Proposed Control Methods for Knee Rehabilitation Robot for Stroke Survivors
- 5 October 2025
- Published by Springer Nature
- p. 391-401
Proposed Control Methods for Knee Rehabilitation Robot for Stroke Survivors
- 5 October 2025
- Published by Springer Nature
- p. 403-411
Evaluating Surface Electromyography Signal of Flexor Digitorum Superficialis Muscle
- 5 October 2025
- Published by Springer Nature
- p. 403-411
Evaluating Surface Electromyography Signal of Flexor Digitorum Superficialis Muscle
- Open Access
- 15 May 2025
- Published by STMIK Dharma Wacana in International Journal of Artificial Intelligence Research
- Vol. 9 (1)
Research on the Application of Artificial Intelligence in Hand Rehabilitation by Estimating Hand Grip Force using EMG Data
The human hand is a complex and functionally significant anatomical structure, playing a critical role in daily activities, communication, and professional tasks. Any impairment due to injury, neurological disorders, or musculoskeletal diseases can severely affect an individual's quality of life. Conditions such as stroke-induced hemiparesis, arthritis, carpal tunnel syndrome, and tendon injuries often necessitate rehabilitation to restore function, minimize pain, and prevent secondary complications. Traditional rehabilitation approaches, while beneficial, generally follow a standardized methodology, failing to account for individual variations in muscle strength, neuroplasticity, and adaptive capacity.Modern rehabilitation methods leverage advanced technologies such as electromyography (EMG) and hand grip force measurement to enhance therapy effectiveness. Additionally, artificial intelligence (AI) applications, particularly Long Short-Term Memory (LSTM) networks and Transformer models, have emerged as promising tools for personalized rehabilitation. These models analyze EMG signals to predict hand movement intentions, enabling adaptive rehabilitation strategies tailored to individual needs. This study focuses on the construction of a real-time EMG signal acquisition system and uses them as input to LSTM and Transformer models to compare and analyze the performance of the two types of models. By demonstrating the superiority of applying AI for personalization over the general AI approach, this study highlights the potential of AI in hand rehabilitation in particular and healthcare in general with its ability to specialize for each individual patient.
- 15 May 2025
- Published by STMIK Dharma Wacana in International Journal of Artificial Intelligence Research
- Vol. 9 (1)
Open AccessResearch on the Application of Artificial Intelligence in Hand Rehabilitation by Estimating Hand Grip Force using EMG Data
The human hand is a complex and functionally significant anatomical structure, playing a critical role in daily activities, communication, and professional tasks. Any impairment due to injury, neurological disorders, or musculoskeletal diseases can severely affect an individual's quality of life. Conditions such as stroke-induced hemiparesis, arthritis, carpal tunnel syndrome, and tendon injuries often necessitate rehabilitation to restore function, minimize pain, and prevent secondary complications. Traditional rehabilitation approaches, while beneficial, generally follow a standardized methodology, failing to account for individual variations in muscle strength, neuroplasticity, and adaptive capacity.Modern rehabilitation methods leverage advanced technologies such as electromyography (EMG) and hand grip force measurement to enhance therapy effectiveness. Additionally, artificial intelligence (AI) applications, particularly Long Short-Term Memory (LSTM) networks and Transformer models, have emerged as promising tools for personalized rehabilitation. These models analyze EMG signals to predict hand movement intentions, enabling adaptive rehabilitation strategies tailored to individual needs. This study focuses on the construction of a real-time EMG signal acquisition system and uses them as input to LSTM and Transformer models to compare and analyze the performance of the two types of models. By demonstrating the superiority of applying AI for personalization over the general AI approach, this study highlights the potential of AI in hand rehabilitation in particular and healthcare in general with its ability to specialize for each individual patient.
- 1 May 2024
- Published by Springer Nature
- p. 235-245
Systematic Design of a Sitting-Type Lower Limb Rehabilitation Robot for Stroke Patient
- 1 May 2024
- Published by Springer Nature
- p. 235-245
Systematic Design of a Sitting-Type Lower Limb Rehabilitation Robot for Stroke Patient
- 1 May 2024
- Published by Springer Nature
- p. 125-133
Proposing Method to Solve Kinematics Problem of a Lower Limb Rehabilitation Robot
- 1 May 2024
- Published by Springer Nature
- p. 125-133
Proposing Method to Solve Kinematics Problem of a Lower Limb Rehabilitation Robot
- Open Access
- 1 January 2024
- Published by Wiley in Journal of Robotics
- Vol. 2024 (1)
Combination of Dynamic Movement Primitives and Recurrent Neural Network to Solve Kinematics and Motion Planning Problems of an Exoskeleton‐Based Rehabilitation Robot
In the field of robotics, especially in exoskeleton‐based rehabilitation robots, motion planning is an important problem. An effective motion trajectory must ensure naturalness and similarity to daily human movements. In this study, the researchers proposed using the dynamic movement primitives (DMPs) method to create trajectories similar to the actual trajectories of daily human activities. Subsequently, the study proposed and constructed a recurrent neural network (RNN) model to solve the inverse kinematics (IK) problem. This model was trained using a large dataset generated from the DMP algorithm mentioned earlier. The IK results applied to simulations on the upper limb exoskeleton robot of Vietnam (UExosVN) under development showed that the obtained trajectories have high accuracy and stability, suitable for control and similar in form to the desired trajectories. The study conducted experiments with two activities of daily living (ADL), namely the playing ball task and drinking water task. The errors in joint variables for the IK problem are all under 1°, except for joint five, which does not significantly impact the robot’s end‐point accuracy. The shape similarity level in the predicted trajectory compared to the test data is mostly above 0.75. The combined approach of DMP and RNN provides a potential solution for designing motion trajectories for rehabilitation robots.
- 1 January 2024
- Published by Wiley in Journal of Robotics
- Vol. 2024 (1)
Open AccessCombination of Dynamic Movement Primitives and Recurrent Neural Network to Solve Kinematics and Motion Planning Problems of an Exoskeleton‐Based Rehabilitation Robot
In the field of robotics, especially in exoskeleton‐based rehabilitation robots, motion planning is an important problem. An effective motion trajectory must ensure naturalness and similarity to daily human movements. In this study, the researchers proposed using the dynamic movement primitives (DMPs) method to create trajectories similar to the actual trajectories of daily human activities. Subsequently, the study proposed and constructed a recurrent neural network (RNN) model to solve the inverse kinematics (IK) problem. This model was trained using a large dataset generated from the DMP algorithm mentioned earlier. The IK results applied to simulations on the upper limb exoskeleton robot of Vietnam (UExosVN) under development showed that the obtained trajectories have high accuracy and stability, suitable for control and similar in form to the desired trajectories. The study conducted experiments with two activities of daily living (ADL), namely the playing ball task and drinking water task. The errors in joint variables for the IK problem are all under 1°, except for joint five, which does not significantly impact the robot’s end‐point accuracy. The shape similarity level in the predicted trajectory compared to the test data is mostly above 0.75. The combined approach of DMP and RNN provides a potential solution for designing motion trajectories for rehabilitation robots.