Jevrem Stojanović
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jevrem Stojanović has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ana Protić
Department of Drug Analysis, University of Belgrade-Faculty of Pharmacy, Vojvode Stepe 450, 11221 Belgrade, Serbia
10 shared publications - Biljana Otašević
Department of Drug Analysis, University of Belgrade-Faculty of Pharmacy, Vojvode Stepe 450, 11221 Belgrade, Serbia
9 shared publications - Anđelija Malenović
University of Belgrade - Faculty of Pharmacy, Department of Drug Analysis, Vojvode Stepe 450, Belgrade, Serbia
7 shared publications - Mira Zečević
Department of Drug Analysis, University of Belgrade-Faculty of Pharmacy, Vojvode Stepe 450, 11221 Belgrade, Serbia
6 shared publications - Dragana Ranđelović
Institute for Technology of Nuclear and Other Mineral Raw Materials, Belgrade, Serbia
2 shared publications - Huseinatu Osman
Department of Drug Analysis, University of Belgrade-Faculty of Pharmacy, Vojvode Stepe 450, 11221 Belgrade, Serbia
2 shared publications
Latest Publications
- Open Access
A Multivariate Approach to the Simultaneous Spectrophotometric Determination of Perindopril Erbumine, Amlodipine Besylate and Indapamide in Fixed-Dose Combination
Spectrophotometry offers the advantage of low cost and less time consumption, making it still attractive as a method of analysis, especially when coupled with multivariate calibration models. This enhancement solves the majority of the drawbacks of UV–VIS spectrophotometry, which have to do with the entangled spectra of complex mixtures. In this study, a multivariate model was developed and validated for the determination of perindopril erbumine, amlodipine besylate and indapamide, addressing previously unresolved challenges by systematically covering three fixed-dose combinations with differing component ratios and by achieving accuracy suitable for the assay determination. The experimental plan involved a Taguchi orthogonal array design with three factors at five levels. In order to create multivariate calibration models, principal component regression, partial least squares and concentration residual augmented least squares regression algorithms were tested. Principal component regression combined with a genetic algorithm for feature selection was chosen as the optimal model based on prediction performance estimated by nested cross-validation with cluster-based sample splitting. The developed method was also evaluated for its environmentally friendly potential while the analytical method validation procedure confirmed its applicability for the assay testing of the fixed-dose drug combination.
Open AccessA Multivariate Approach to the Simultaneous Spectrophotometric Determination of Perindopril Erbumine, Amlodipine Besylate and Indapamide in Fixed-Dose Combination
Spectrophotometry offers the advantage of low cost and less time consumption, making it still attractive as a method of analysis, especially when coupled with multivariate calibration models. This enhancement solves the majority of the drawbacks of UV–VIS spectrophotometry, which have to do with the entangled spectra of complex mixtures. In this study, a multivariate model was developed and validated for the determination of perindopril erbumine, amlodipine besylate and indapamide, addressing previously unresolved challenges by systematically covering three fixed-dose combinations with differing component ratios and by achieving accuracy suitable for the assay determination. The experimental plan involved a Taguchi orthogonal array design with three factors at five levels. In order to create multivariate calibration models, principal component regression, partial least squares and concentration residual augmented least squares regression algorithms were tested. Principal component regression combined with a genetic algorithm for feature selection was chosen as the optimal model based on prediction performance estimated by nested cross-validation with cluster-based sample splitting. The developed method was also evaluated for its environmentally friendly potential while the analytical method validation procedure confirmed its applicability for the assay testing of the fixed-dose drug combination.
- Open Access
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Sesija 12 ,p. 84
Integration of chiral chromatography with machine learning algorithms for retention and enantioselectivity prediction on ovomucoid chiral stationary phase
The mechanisms responsible for enantiorecognition in chiral chromatography are highly complex, and efforts to better understand them have intensified over the past decades. Many uncertainties remain, including the need for numerous "trial-and-error" experiments, questionable separation efficiency, and poor reproducibility of results. The integration of chiral chromatography with the methodology of machine learning algorithms represents modern attempts to solve and overcome these shortcomings, through gradual transition from the traditional approach "trial-and-error" to the application of intelligent approaches that use available data for predicting retention and enantioseparation. In this research, artificial neural networks were used for mixed modelling of the retention behavior and enantioselectivity on the ovomucoid chiral stationary phase for 50 chiral analytes with different structural and physicochemical characteristics. The experimental results were obtained by performing the central composite design with 18 experimental points, in which the acetonitrile content in the mobile phase, the pH value and the concentration of ammonium chloride in the aqueous part of the mobile phase were varied. In addition to the chromatographic parameters, a carefully selected 35 molecular descriptors were used as input data for modeling. Output variables were logarithmically transformed - to predict retention t r and enantioselectivity α and Δtr. The strength of the predictive networks performance was estimated based on the obtained R2 and RMSE values for the training, validation and test set. The obtained models showed good performance for output log TR - R2training>0.90, R2CV>0.80, R2test>0.90, and slightly lower for log α - R2training>0.75, R2CV>0.60, R2test>0.75 and for Δtr - R2training>0.85, R2 CV>0.75, R2test>0.80.
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Sesija 12 ,p. 84
Open AccessIntegration of chiral chromatography with machine learning algorithms for retention and enantioselectivity prediction on ovomucoid chiral stationary phase
The mechanisms responsible for enantiorecognition in chiral chromatography are highly complex, and efforts to better understand them have intensified over the past decades. Many uncertainties remain, including the need for numerous "trial-and-error" experiments, questionable separation efficiency, and poor reproducibility of results. The integration of chiral chromatography with the methodology of machine learning algorithms represents modern attempts to solve and overcome these shortcomings, through gradual transition from the traditional approach "trial-and-error" to the application of intelligent approaches that use available data for predicting retention and enantioseparation. In this research, artificial neural networks were used for mixed modelling of the retention behavior and enantioselectivity on the ovomucoid chiral stationary phase for 50 chiral analytes with different structural and physicochemical characteristics. The experimental results were obtained by performing the central composite design with 18 experimental points, in which the acetonitrile content in the mobile phase, the pH value and the concentration of ammonium chloride in the aqueous part of the mobile phase were varied. In addition to the chromatographic parameters, a carefully selected 35 molecular descriptors were used as input data for modeling. Output variables were logarithmically transformed - to predict retention t r and enantioselectivity α and Δtr. The strength of the predictive networks performance was estimated based on the obtained R2 and RMSE values for the training, validation and test set. The obtained models showed good performance for output log TR - R2training>0.90, R2CV>0.80, R2test>0.90, and slightly lower for log α - R2training>0.75, R2CV>0.60, R2test>0.75 and for Δtr - R2training>0.85, R2 CV>0.75, R2test>0.80.
- Open Access
- 1 January 2026
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 91 (00) , 13
Embracing green chromatography principles in perindopril, amlodipine and indapamide drug mixture analysis using β-cyclodextrin modified mobile phase
Raising the level of environmental awareness in the field of liquid chromatography is considered indispensable while the use of ?-cyclodextrin in a mobile phase is promising strategy in this regard. This study presents a method development in lined with ICH Q14 regulatory requirements for introducing sustainability and method life-cycle management to separate components of a cardiovascular multi-drug tablet formulation. At the beginning, the analytical method target profile was defined, separation of perindopril, amlodipine, and indapamide in a shortest possible analytical run time. Following risk analysis pointed out that the mobile phase constituents represent the critical method parameters affecting the chromatographic analyses. Design of experiments methodology and Desirability function calculation was employed to simultaneously optimize the levels of concentration of ?-cyclodextrin solution, pH value and acetonitrile content in the mobile phase investigated in the ranges 5-15 mM, 4.0-6.0 and 20-30% (v/v), respectively. The optimal chromatographic conditions consisted of 10 mM ?-cyclodextrin (pH 5.4) and acetonitrile in the ratio 70:30 (v/v), 2 mL min-1 flow rate, RP-18e column kept at 25?C, 215 nm detection wavelength, and 10 ?L injection volume. The eco-friendliness of the method was assessed using the AGREE tool indicating a green and sustainable method was successfully developed.
- 1 January 2026
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 91 (00) , 13
Open AccessEmbracing green chromatography principles in perindopril, amlodipine and indapamide drug mixture analysis using β-cyclodextrin modified mobile phase
Raising the level of environmental awareness in the field of liquid chromatography is considered indispensable while the use of ?-cyclodextrin in a mobile phase is promising strategy in this regard. This study presents a method development in lined with ICH Q14 regulatory requirements for introducing sustainability and method life-cycle management to separate components of a cardiovascular multi-drug tablet formulation. At the beginning, the analytical method target profile was defined, separation of perindopril, amlodipine, and indapamide in a shortest possible analytical run time. Following risk analysis pointed out that the mobile phase constituents represent the critical method parameters affecting the chromatographic analyses. Design of experiments methodology and Desirability function calculation was employed to simultaneously optimize the levels of concentration of ?-cyclodextrin solution, pH value and acetonitrile content in the mobile phase investigated in the ranges 5-15 mM, 4.0-6.0 and 20-30% (v/v), respectively. The optimal chromatographic conditions consisted of 10 mM ?-cyclodextrin (pH 5.4) and acetonitrile in the ratio 70:30 (v/v), 2 mL min-1 flow rate, RP-18e column kept at 25?C, 215 nm detection wavelength, and 10 ?L injection volume. The eco-friendliness of the method was assessed using the AGREE tool indicating a green and sustainable method was successfully developed.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Poster pre,p. 38-39
Comparing overlapping mean response, desirability functions, and analytical quality by design approaches to the optimization of chaotropic chromatography method for the separation of citalopram and its impurities
Traditional approaches to multicriteria optimization, including desirability functions and overlapping mean responses (OMRs), are not aligned with definition of design space in ICH Q14 because they do not provide a measure of quality assurance, i.e., the probability that critical quality attributes (CQAs) meet acceptance limits [1]. Furthermore, these approaches neglect uncertainty of the model coefficient estimates and correlation of the regression residuals [2]. The aim of this work was to evaluate how such theoretical differences affect the optimization results using the example of a stability-indicating method for citalopram tablets. In this case, the retention factor of impurity A (k) and the resolution between citalopram and impurity E (Rs) were selected as CQAs with the following acceptance limits: k > 1 and RS > 2. Critical parameters of the analytical method were acetonitrile content, perchlorate concentration in the mobile phase, and column temperature. The region obtained by OMR, the region where the global desirability function exceeded 0.6, and the design space derived by Bayesian analysis were compared. Two-dimensional contour plots showed that the optimal regions obtained by traditional approaches largely overlapped with the design space. This can be explained by the low correlation of the residuals (-0.26) and the low standard errors of the model coefficients (0.0015-0.0240). Since there is no available software to determine the design space according to ICH Q14, a possible alternative is to report the measures of parameters uncertainty and residual correlation along with traditional optimization results, providing an additional measure of analytical method quality.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Poster pre,p. 38-39
Comparing overlapping mean response, desirability functions, and analytical quality by design approaches to the optimization of chaotropic chromatography method for the separation of citalopram and its impurities
Traditional approaches to multicriteria optimization, including desirability functions and overlapping mean responses (OMRs), are not aligned with definition of design space in ICH Q14 because they do not provide a measure of quality assurance, i.e., the probability that critical quality attributes (CQAs) meet acceptance limits [1]. Furthermore, these approaches neglect uncertainty of the model coefficient estimates and correlation of the regression residuals [2]. The aim of this work was to evaluate how such theoretical differences affect the optimization results using the example of a stability-indicating method for citalopram tablets. In this case, the retention factor of impurity A (k) and the resolution between citalopram and impurity E (Rs) were selected as CQAs with the following acceptance limits: k > 1 and RS > 2. Critical parameters of the analytical method were acetonitrile content, perchlorate concentration in the mobile phase, and column temperature. The region obtained by OMR, the region where the global desirability function exceeded 0.6, and the design space derived by Bayesian analysis were compared. Two-dimensional contour plots showed that the optimal regions obtained by traditional approaches largely overlapped with the design space. This can be explained by the low correlation of the residuals (-0.26) and the low standard errors of the model coefficients (0.0015-0.0240). Since there is no available software to determine the design space according to ICH Q14, a possible alternative is to report the measures of parameters uncertainty and residual correlation along with traditional optimization results, providing an additional measure of analytical method quality.
- Open Access
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Poster pre,p. 40-41
Preliminary chemometric assisted spectrophotometric analysis of multi-component pharmaceutical formulation
Multidrug analysis presents significant challenges due to the intricate nature of compounds. Chemometrics and multivariate methods effectively mitigate spectral interference encountered in spectrophotometric techniques for pharmaceutical quantification. This research aimed to employ UV spectrophotometric measurements coupled with chemometrics for both qualitative and quantitative analysis of three active pharmaceutical substances: perindopril erbumine, amlodipine besylate, and indapamide. The experimental design was constructed using Design Expert 11.0 (Stat Ease, USA), employing a 5-level-3-factor design. The wavelength range was from 200 to 400 nm, the speed is set at 800 nm/min, and the step size is precisely set at 1.280 nm, with a slit width of 1.5 nm. Stock solutions were prepared in a 50/50 mixture of ethanol-distilled water. Subsequently, working solutions were diluted with distilled water to achieve a concentration range of 10-50 µg/mL for the three active pharmaceutical ingredients. Spectral data was collected using a Cintra 202 UV spectrophotometer (GBC, Australia), equipped with Cintral software version 2.2. The UV spectral overlapping was recorded and disentangled employing Partial Least Square (PLS) coupled with Genetic Algorithm (GA). This methodology was selected due to its remarkable ability to reduce the number of variables to those that possess predictive capabilities, thereby optimizing the model accuracy and repeatability. The developed method presents a cost-effective and time-efficient alternative to the conventional HPLC standard method.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Poster pre,p. 40-41
Open AccessPreliminary chemometric assisted spectrophotometric analysis of multi-component pharmaceutical formulation
Multidrug analysis presents significant challenges due to the intricate nature of compounds. Chemometrics and multivariate methods effectively mitigate spectral interference encountered in spectrophotometric techniques for pharmaceutical quantification. This research aimed to employ UV spectrophotometric measurements coupled with chemometrics for both qualitative and quantitative analysis of three active pharmaceutical substances: perindopril erbumine, amlodipine besylate, and indapamide. The experimental design was constructed using Design Expert 11.0 (Stat Ease, USA), employing a 5-level-3-factor design. The wavelength range was from 200 to 400 nm, the speed is set at 800 nm/min, and the step size is precisely set at 1.280 nm, with a slit width of 1.5 nm. Stock solutions were prepared in a 50/50 mixture of ethanol-distilled water. Subsequently, working solutions were diluted with distilled water to achieve a concentration range of 10-50 µg/mL for the three active pharmaceutical ingredients. Spectral data was collected using a Cintra 202 UV spectrophotometer (GBC, Australia), equipped with Cintral software version 2.2. The UV spectral overlapping was recorded and disentangled employing Partial Least Square (PLS) coupled with Genetic Algorithm (GA). This methodology was selected due to its remarkable ability to reduce the number of variables to those that possess predictive capabilities, thereby optimizing the model accuracy and repeatability. The developed method presents a cost-effective and time-efficient alternative to the conventional HPLC standard method.
- Open Access
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Poster pre,p. 36-37
Comparison of different approaches to the design space computation: Example of stability-indicating method for citalopram tablets
Based on the ICH Q14 definition, design space for analytical methods can be described as a subset of investigated experimental conditions for which it can be demonstrated, with sufficient probability, that method fulfills predefined criteria [1]. The response distribution should be simulated and the experimental conditions, for which the probability that the critical quality attributes (CQAs) are within acceptance region is above the desired quality level (p), should be included in the design space. Monte-Carlo simulations, bootstrapping, and Bayesian analysis [2] can be applied, with the last approach preferred as it accounts for both model parameter uncertainty and data correlations [3]. This study aimed to investigate differences between the three approaches to derive the design space for a chromatographic stability-indicating method for citalopram tablets. Retention of impurity A (k) and resolution between citalopram and impurity E (Rs) were selected as CQAs (Y), while acetonitrile content, perchlorate concentration in the mobile phase, and column temperature were critical process parameters (X). The acceptance region for CQAs was set as 𝑆𝑆 = {(𝑘𝑘,𝑅𝑅𝑠𝑠):𝑘𝑘 > 1, 𝑅𝑅𝑠𝑠 > 2} and the design space as DS = {x∈𝜒𝜒|𝑃𝑃(Y∈𝑆𝑆)≥𝜋𝜋} with p = 0.9. Contour plots showing the dependence of the probability on acetonitrile content and column temperature at five different perchlorate concentrations showed no significant differences, which can be attributed to the low uncertainty of the model parameters (0.0015-0.0240) and weak correlation of regression residuals (-0.26). A wider range of parameter uncertainties, residual correlations, etc. need to be investigated to determine areas of practical equivalence of the examined approaches.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Poster pre,p. 36-37
Open AccessComparison of different approaches to the design space computation: Example of stability-indicating method for citalopram tablets
Based on the ICH Q14 definition, design space for analytical methods can be described as a subset of investigated experimental conditions for which it can be demonstrated, with sufficient probability, that method fulfills predefined criteria [1]. The response distribution should be simulated and the experimental conditions, for which the probability that the critical quality attributes (CQAs) are within acceptance region is above the desired quality level (p), should be included in the design space. Monte-Carlo simulations, bootstrapping, and Bayesian analysis [2] can be applied, with the last approach preferred as it accounts for both model parameter uncertainty and data correlations [3]. This study aimed to investigate differences between the three approaches to derive the design space for a chromatographic stability-indicating method for citalopram tablets. Retention of impurity A (k) and resolution between citalopram and impurity E (Rs) were selected as CQAs (Y), while acetonitrile content, perchlorate concentration in the mobile phase, and column temperature were critical process parameters (X). The acceptance region for CQAs was set as 𝑆𝑆 = {(𝑘𝑘,𝑅𝑅𝑠𝑠):𝑘𝑘 > 1, 𝑅𝑅𝑠𝑠 > 2} and the design space as DS = {x∈𝜒𝜒|𝑃𝑃(Y∈𝑆𝑆)≥𝜋𝜋} with p = 0.9. Contour plots showing the dependence of the probability on acetonitrile content and column temperature at five different perchlorate concentrations showed no significant differences, which can be attributed to the low uncertainty of the model parameters (0.0015-0.0240) and weak correlation of regression residuals (-0.26). A wider range of parameter uncertainties, residual correlations, etc. need to be investigated to determine areas of practical equivalence of the examined approaches.
- Open Access
Carbonization of Invasive Plant Species—Novel Route for Removal of Active Pharmaceutical Ingredients via Adsorption
The development of efficient adsorbents for sustainable adsorption processes is required in environmental studies. Here, we propose using carbonized Ailanthus altissima leaves as a novel adsorbent, derived from invasive species that threaten biodiversity. Biochar was prepared by pyrolysis at 500 °C, activated with ZnCl2 and tested for the target adsorbates—active pharmaceutical ingredients (APIs). A range of characterization techniques were employed—FTIR, SEM, XPS and Raman spectroscopy—and the adsorption of representative APIs was analyzed. The adsorption kinetics revealed that the adsorbent reached equilibrium within a 3 h period. The adsorption capacities for the selected model substances ranged from 59 mg g−1 for atenolol to 112 mg g−1 for paracetamol, while the highest values were recorded for ketorolac and tetracycline at over 130 mg g−1. The excellent retention is ascribed to the developed surface area, the availability of oxygen surface functional groups and the aromatization of the biochar. The proposed biochar, which is obtained in a sustainable process, proves to be a highly efficient adsorbent for selected pharmaceuticals.
Open AccessCarbonization of Invasive Plant Species—Novel Route for Removal of Active Pharmaceutical Ingredients via Adsorption
The development of efficient adsorbents for sustainable adsorption processes is required in environmental studies. Here, we propose using carbonized Ailanthus altissima leaves as a novel adsorbent, derived from invasive species that threaten biodiversity. Biochar was prepared by pyrolysis at 500 °C, activated with ZnCl2 and tested for the target adsorbates—active pharmaceutical ingredients (APIs). A range of characterization techniques were employed—FTIR, SEM, XPS and Raman spectroscopy—and the adsorption of representative APIs was analyzed. The adsorption kinetics revealed that the adsorbent reached equilibrium within a 3 h period. The adsorption capacities for the selected model substances ranged from 59 mg g−1 for atenolol to 112 mg g−1 for paracetamol, while the highest values were recorded for ketorolac and tetracycline at over 130 mg g−1. The excellent retention is ascribed to the developed surface area, the availability of oxygen surface functional groups and the aromatization of the biochar. The proposed biochar, which is obtained in a sustainable process, proves to be a highly efficient adsorbent for selected pharmaceuticals.
- Open Access
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Arhiv za farmaciju
- Vol. 74 (3) , 235-266
Concept of ecologically acceptable chromatographic methods: Case study on the separation of dronedarone hydrochloride and its degradation products
Recently, concern about the environmental impact of drug analysis methods has increased significantly. Reversed-phase high-performance liquid chromatography (RP-HPLC), the predominant technique in drug analysis, relies heavily on organic solvents such as acetonitrile, which is known for its chromatographic efficiency, but also for its toxicity and flammability. To address these concerns, it is essential to minimize the use of toxic organic solvents. The aim of this study is to explore greener RP-HPLC modifications and evaluate their applicability in the pharmaceutical industry. Methods were developed for the separation of dronedarone hydrochloride and its degradation products based on experimental design, including micellar liquid chromatography (MLC), b-cyclodextrin (CD) modified RP-HPLC and ultra-high performance liquid chromatography (UHPLC). The eco-friendliness of these methods was assessed using the analytical eco-scale score, green analytical procedure index (GAPI) and analytical greenness (AGREE). AGREE appears to be the most suitable, as it revealed the greatest differences between the compared methods, as well as insights into critical aspects of the methods. UHPLC and b-CD modified RP-HPLC have been shown to be superior to MLC, and both methods can be a good choice, depending on whether the ease of implementation or energy efficiency is considered to be a more important criterion.
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Arhiv za farmaciju
- Vol. 74 (3) , 235-266
Open AccessConcept of ecologically acceptable chromatographic methods: Case study on the separation of dronedarone hydrochloride and its degradation products
Recently, concern about the environmental impact of drug analysis methods has increased significantly. Reversed-phase high-performance liquid chromatography (RP-HPLC), the predominant technique in drug analysis, relies heavily on organic solvents such as acetonitrile, which is known for its chromatographic efficiency, but also for its toxicity and flammability. To address these concerns, it is essential to minimize the use of toxic organic solvents. The aim of this study is to explore greener RP-HPLC modifications and evaluate their applicability in the pharmaceutical industry. Methods were developed for the separation of dronedarone hydrochloride and its degradation products based on experimental design, including micellar liquid chromatography (MLC), b-cyclodextrin (CD) modified RP-HPLC and ultra-high performance liquid chromatography (UHPLC). The eco-friendliness of these methods was assessed using the analytical eco-scale score, green analytical procedure index (GAPI) and analytical greenness (AGREE). AGREE appears to be the most suitable, as it revealed the greatest differences between the compared methods, as well as insights into critical aspects of the methods. UHPLC and b-CD modified RP-HPLC have been shown to be superior to MLC, and both methods can be a good choice, depending on whether the ease of implementation or energy efficiency is considered to be a more important criterion.
- Open Access
- 1 January 2023
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Arhiv za farmaciju
- Vol. 73 (2) , 146-171
Resource management in HPLC: Unveiling a green face of pharmaceutical analysis
High-pressure liquid chromatography (HPLC) is a technique of paramount importance in the analysis of pharmaceuticals because of its ability to separate moderately polar to less polar compounds, such as drugs and related substances.High-pressure liquid chromatography (HPLC) is a technique of paramount importance in the analysis of pharmaceuticals because of its ability to separate moderately polar to less polar compounds, such as drugs and related substances. The concept of green analytical chemistry (GAC) aims to provide more environmentally friendly and safer analytical methods in terms of reagents, energy, and waste. One of the major challenges of GAC is to find an appropriate approach to evaluate the greenness of analytical methods. An extension of GAC, called white analytical chemistry (WAC), has been introduced to consider not only environmental friendliness, but also other aspects that contribute to the sustainability of methods, such as analytical and economic or practical efficiency. HPLC methods are intrinsically not green, due to the high consumption of toxic organic solvents and the resulting generation of large amounts of toxic waste. Fortunately, there are many approaches to overcome the non-green character of HPLC methods. In this article, various modifications of the HPLC methods that increase its environmental friendliness are presented, as well as the various tools used to evaluate environmental friendliness. In addition, the new concept of white analytical chemistry is presented.
- 1 January 2023
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Arhiv za farmaciju
- Vol. 73 (2) , 146-171
Open AccessResource management in HPLC: Unveiling a green face of pharmaceutical analysis
High-pressure liquid chromatography (HPLC) is a technique of paramount importance in the analysis of pharmaceuticals because of its ability to separate moderately polar to less polar compounds, such as drugs and related substances.High-pressure liquid chromatography (HPLC) is a technique of paramount importance in the analysis of pharmaceuticals because of its ability to separate moderately polar to less polar compounds, such as drugs and related substances. The concept of green analytical chemistry (GAC) aims to provide more environmentally friendly and safer analytical methods in terms of reagents, energy, and waste. One of the major challenges of GAC is to find an appropriate approach to evaluate the greenness of analytical methods. An extension of GAC, called white analytical chemistry (WAC), has been introduced to consider not only environmental friendliness, but also other aspects that contribute to the sustainability of methods, such as analytical and economic or practical efficiency. HPLC methods are intrinsically not green, due to the high consumption of toxic organic solvents and the resulting generation of large amounts of toxic waste. Fortunately, there are many approaches to overcome the non-green character of HPLC methods. In this article, various modifications of the HPLC methods that increase its environmental friendliness are presented, as well as the various tools used to evaluate environmental friendliness. In addition, the new concept of white analytical chemistry is presented.