ASAlto Stemmer

Alto Stemmer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alto Stemmer has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 3D Brachial Plexus Neurography With Variable‐Rate Selective Excitation RF Pulses

    by Emma J. McKinney, Xiaoying Cai, Darryl B. Sneag, Philip G. Colucci, Yenpo Lin, Ji Lin, Shu‐Han Wang, Guido Buonincontri, Marcel Dominik Nickel, Nicolas Gross‐Weege, et al.

    Background: Slab‐selective radiofrequency (RF) pulses are commonly required in three‐dimensional (3D) turbo spin echo (TSE) in brachial plexus magnetic resonance neurography (MRN). However, their long selective RF pulses lead to violation of Carr–Purcell–Meiboom–Gill conditions, which might increase imaging artifacts. Hypothesis: That VERSE STIR‐TSE would yield comparable motion artifact to conventional STIR‐TSE with superior nerve conspicuity and greater subjective appeal. Study Type: Prospective, cross‐sectional study. Population: Twenty‐four subjects (16 females; mean age: 43.7 years; range: 19–76 years) evaluated for clinical suspicion of brachial plexopathy, undergoing brachial plexus MRI (10 left, 9 right, 5 bilateral, 29 total scans analyzed). Agar phantoms mimicking nerve and muscle were also evaluated. Field Strength/Sequence: 3‐Tesla, 3D STIR‐TSE with and without VERSE. Assessment: Three radiologists, blinded to the sequence type and clinical data, qualitatively evaluated nerve conspicuity, motion, and preferred sequence on a 5‐point scale. Statistical Tests: Wilcoxon signed‐rank tests compared nerve conspicuity (0–4 scale), motion artifact (0–4 scale), and preferred series between the non‐VERSE and VERSE pulse sequences. Gwet's AC2 assessed inter‐rater agreement. A p ‐value < 0.05 was considered statistically significant. Results: The VERSE STIR‐TSE sequence was significantly preferred by all raters. Motion artifact was not significantly different between the sequences ( p = 0.11). Conspicuity of the suprascapular nerve was significantly greater with VERSE for both its proximal segments (median: 3, interquartile range: (2, 4), vs. 3 (1, 4)) and distal segments (4 (2, 4) vs. 3 (2, 4)), but conspicuity of the axillary nerve was not significantly different between the sequences ( p = 0.27–0.61). Phantom scans confirmed a 74% and 49% increase in signal with VERSE in the muscle and nerve‐mimicking phantoms, respectively. Data Conclusion: STIR‐TSE with VERSE provided overall superior image quality for brachial plexus MRN as compared to conventional STIR‐TSE. Evidence Level: 2. Technical Level: 1.


  • Open Access

    Association Between Thrombus Signal Intensity and Pulmonary Embolism in Patients With Proximal Deep Vein Thrombosis: A Magnetic Resonance Imaging Study

    by Xinyu Wang, Congrui Sun, Yuehong Liu, Yichen Tang, Chen Zhang, Alto Stemmer, Jiajia Zhang, Guoxi Xie, Chunmin Li, Qi Yang

    BACKGROUND: Approximately 50% of deep vein thrombosis (DVT) occurrences in the lower extremity proximal veins are associated with pulmonary embolism (PE). The progression of proximal DVT is critical in PE development, as reflected by thrombus composition. Magnetic resonance black-blood thrombus imaging can identify venous thrombus components by displaying thrombus signal intensity variations. This study investigated the association between thrombus signal intensity and PE in patients with proximal DVT. METHODS: A total of 126 patients with proximal DVT were recruited, and all underwent magnetic resonance black-blood thrombus imaging examination. The patients were divided into 2 groups: DVT-only and DVT with PE. The whole thrombus signal intensity ratio, proximal thrombus signal intensity ratio, distal thrombus signal intensity ratio, and thrombus volume were assessed. Histological analysis was performed to characterize the thrombus content. Logistic regression models were performed to evaluate the relationship between thrombus signal intensity and PE. RESULTS: Of the 126 eligible patients, 73 (58%) patients were in the DVT with PE group. Both proximal thrombus signal intensity ratio and whole thrombus signal intensity ratio were lower in the DVT with PE group compared with the DVT-only group (1.92±0.54 versus 1.31±0.42, P P =0.034). The percentage of fibrin area (13.99±1.56% versus 7.51±1.25%, P =0.0087) and red blood cells area (49.65±18.8% versus 13.41±4.74%, P =0.0012) were higher in DVT with PE than DVT-only group. Univariate and multivariate logistic regression analysis showed that proximal thrombus signal intensity ratio remained statistically significant (odds ratio, 0.21 [95% CI, 0.12–0.39]; P <0.001). CONCLUSIONS: The proximal thrombus signal intensity ratio of the thrombus was independently associated with acute PE in patients with proximal lower extremity DVT, suggesting that thrombus components may be important in PE occurrence. These findings could provide novel insights for understanding DVT evolution.


  • Whole-Body Tumor Load ADC Histogram Analysis for Therapy Response Prediction and Evaluation for Multiple Myeloma

    by Yuhan Gao, Qin Wang, Lu Zhang, Shuang Xia, Jinxia Zhu, Rober Grimm, Alto Stemmer, Shuo Li, Dong Liu, Huadan Xue, et al.

    This study aimed to explore the value of histogram analysis of apparent diffusion coefficient (ADC) maps for whole-body tumor load(WBTL) in predicting and evaluating the treatment response based on International Myeloma Working Group (IMWG) 2016 consensus criteria in patients with multiple myeloma (MM).Histogram analysis of ADC maps extracted eight parameters: mean, median, standard-deviation, entropy, skewness, kurtosis, ADC_5%, and ADC_95%. Seven parameters at baseline were significantly associated with therapy response. Three parameters in treatment percentage change were significantly associated with therapy response. ADC histogram analysis may be considered as an adjunct tool to the MM therapy response evaluation and prediction.

  • Iterative Denoising Accelerated 3D FLAIR Sequence for Hydrops MR Imaging at 3T

    by R. Quint, A. Vaussy, A. Stemmer, C. Hautefort, E. Houdart, M. Eliezer

    BACKGROUND AND PURPOSE: 3D FLAIR sequences have become the criterion standard for identifying endolymphatic hydrops, but scan time remains an important limitation to their widespread use. Our purpose was to evaluate the diagnostic performance and image quality of an accelerated 3D FLAIR sequence combined with an iterative denoising algorithm. MATERIALS AND METHODS: This was a retrospective study performed on 30 patients with clinical suspicion of endolymphatic hydrops who underwent 3T MR imaging 4 hours after gadolinium injection using two 3D FLAIR sequences. The first (conventional FLAIR) was accelerated with a conventional turbo factor of 187. The second was accelerated with an increased turbo factor of 263, resulting in a 33% scan time reduction (5 minutes 36 seconds versus 8 minutes 15 seconds, respectively). A sequence was reconstructed in-line immediately after the accelerated 3D FLAIR acquisition from the same raw data with iterative denoising (accelerated-FLAIR iterative denoising). The signal intensity ratio image quality score and endolymphatic hydrops diagnosis were evaluated. RESULTS: The mean signal intensity ratio for symptomatic and asymptomatic ears of accelerated-FLAIR iterative denoising was significantly higher than the mean SNR of conventional FLAIR (29.5 versus 19 and 25.9 versus 16.3, P < .001). Compared with the conventional FLAIR sequence, the image-quality score was higher with accelerated-FLAIR iterative denoising (mean image-quality score, 3.8 [SD, 0.4] versus 3.3 [SD, 0.6] for accelerated-FLAIR iterative denoising and conventional FLAIR, respectively, P = .003). There was no significant difference in the diagnosis of endolymphatic hydrops between the 2 sequences. Interreader agreement was good-to-excellent. CONCLUSIONS: The iterative denoising algorithm applied to an accelerated 3D FLAIR sequence for exploration of endolymphatic hydrops enabled significantly reducing the scan time without compromising image quality and diagnostic performance.


  • Combining b2500 diffusion-weighted imaging with BI-RADS improves the specificity of breast MRI

    by Laetitia Saccenti, Constance de Margerie Mellon, Margaux Scholer, Zoe Jolibois, Alto Stemmer, Elisabeth Weiland, Cedric de Bazelaire


  • Improved detection of juxtacortical lesions using highly accelerated double inversion-recovery MRI in patients with multiple sclerosis

    by Morgane Lespagnol, Aurélien Massire, Imen Megdiche, Fabien Lespagnol, Pierre Brugières, Alain Créange, Alto Stemmer, Blanche Bapst


  • Open Access

    Improved image reconstruction incorporating non-rigid motion correction for cardiac MRI using BLADE acquisition

    by Peter Kellman, Magalie Viallon, Christophe Chefd'Hotel, Alto Stemmer, Pierre Croisille