Yalin Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yalin Yan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Yi Tang
State Key Laboratory of Building Safety and Environment, China Academy of Building Research, Beijing 100013, China
3 shared publications - Congzhen Xiao
China Academy of Building Research
2 shared publications - Zhenhong Wu
China Academy of Building Research, No. 30 North Third Ring Road East, Beijing 100029, China
2 shared publications - Honghai Li
State Key Laboratory of Building Safety and Environment, China Academy of Building Research, Beijing 100013, China
1 shared publication - Jinsheng Wen
1 China Academy of Building Research, Beijing, 100013, China
1 shared publication Kai Chen
1 shared publication
Latest Publications
- Open Access
Wind-Resistant Configuration of Double-Layer Cable-Supported Flexible Photovoltaic Array Based on Interference Effect Analysis
This study investigates the wind-resistant configuration of a seven-row single-span double-layer cable-supported photovoltaic (PV) array through conducting systematic analysis of the interference effect. Wind tunnel pressure measurement tests were conducted on a rigid model to obtain the wind force coefficients and torque coefficients under different wind directions. The time histories of wind pressure obtained from the tests were imported into a finite element (FE) model to calculate the vertical displacement and torsional angle responses. The wind-induced responses of different configurations with varying quantities and arrangements of longitudinal connections and wind-resistant cables were analyzed. The results indicate that in the case of head-on wind, wind force is the most unfavorable, and the correlation between wind force and torque is relatively low. In the case of oblique incoming flow, torque is the most adverse, and the correlation between wind force and torque increases. Directions of vertical displacement are opposite in windward and leeward wind scenarios, but directions of torsion angle remain consistent. Overall, the wind-induced responses at mid-span are greater than those at the edge, and the first-row response is more significant than that of the subsequent rows. The wind-induced vibration under windward flow conditions is more adverse when compared to that under leeward flow conditions. However, the downstream adverse interference effect caused by leeward incoming flow is more prominent. Based on the comprehensive analysis of wind loads and wind-induced responses, the whole structure is divided into three zones, namely, wind-induced response control zone, local wind pressure control zone, and wind effect transition zone. A wind-resistant configuration with longitudinal connection arrangements considering both safety and economic benefits is proposed, which provides a reference for the wind-resistant design of similar structures.
Open AccessWind-Resistant Configuration of Double-Layer Cable-Supported Flexible Photovoltaic Array Based on Interference Effect Analysis
This study investigates the wind-resistant configuration of a seven-row single-span double-layer cable-supported photovoltaic (PV) array through conducting systematic analysis of the interference effect. Wind tunnel pressure measurement tests were conducted on a rigid model to obtain the wind force coefficients and torque coefficients under different wind directions. The time histories of wind pressure obtained from the tests were imported into a finite element (FE) model to calculate the vertical displacement and torsional angle responses. The wind-induced responses of different configurations with varying quantities and arrangements of longitudinal connections and wind-resistant cables were analyzed. The results indicate that in the case of head-on wind, wind force is the most unfavorable, and the correlation between wind force and torque is relatively low. In the case of oblique incoming flow, torque is the most adverse, and the correlation between wind force and torque increases. Directions of vertical displacement are opposite in windward and leeward wind scenarios, but directions of torsion angle remain consistent. Overall, the wind-induced responses at mid-span are greater than those at the edge, and the first-row response is more significant than that of the subsequent rows. The wind-induced vibration under windward flow conditions is more adverse when compared to that under leeward flow conditions. However, the downstream adverse interference effect caused by leeward incoming flow is more prominent. Based on the comprehensive analysis of wind loads and wind-induced responses, the whole structure is divided into three zones, namely, wind-induced response control zone, local wind pressure control zone, and wind effect transition zone. A wind-resistant configuration with longitudinal connection arrangements considering both safety and economic benefits is proposed, which provides a reference for the wind-resistant design of similar structures.
- Open Access
- 15 May 2025
- Published by JVE International Ltd. in Vibroengineering PROCEDIA
- Vol. 58, 39-45
Muti-objective optimization of tuned liquid column damper design parameters for vibration control under wind load
Tuned Liquid Column Dampers (TLCDs) are widely used as passive devices for vibration control in structures dominated by wind loads, utilizing the oscillation of liquid in a U-shaped container to dissipate energy. The effectiveness of TLCDs is significantly influenced by key design parameters, like mass ratio, tuning frequency ratio, and head loss coefficient. This study developed governing equations of TLCDs and investigated the influence of external load excitation spectrum on the vibration mitigation performance. A multi-objective optimization approach based on the Non-dominated Sorting Genetic Algorithm II (NSGA-II) was proposed to identify optimal design parameters of TLCDs under various loading conditions. The results revealed that the external excitation spectrum played a crucial role in determining the optimal parameters, and the damper performance was distinctly different when the excitation frequencies changed. This optimization method was validated through a 200-meter high tower, where the optimized TLCD significantly enhanced vibration control performance at a wide range of wind directions. These findings offered valuable insights for the application of TLCDs in complex environments with varying external load characteristics.
- 15 May 2025
- Published by JVE International Ltd. in Vibroengineering PROCEDIA
- Vol. 58, 39-45
Open AccessMuti-objective optimization of tuned liquid column damper design parameters for vibration control under wind load
Tuned Liquid Column Dampers (TLCDs) are widely used as passive devices for vibration control in structures dominated by wind loads, utilizing the oscillation of liquid in a U-shaped container to dissipate energy. The effectiveness of TLCDs is significantly influenced by key design parameters, like mass ratio, tuning frequency ratio, and head loss coefficient. This study developed governing equations of TLCDs and investigated the influence of external load excitation spectrum on the vibration mitigation performance. A multi-objective optimization approach based on the Non-dominated Sorting Genetic Algorithm II (NSGA-II) was proposed to identify optimal design parameters of TLCDs under various loading conditions. The results revealed that the external excitation spectrum played a crucial role in determining the optimal parameters, and the damper performance was distinctly different when the excitation frequencies changed. This optimization method was validated through a 200-meter high tower, where the optimized TLCD significantly enhanced vibration control performance at a wide range of wind directions. These findings offered valuable insights for the application of TLCDs in complex environments with varying external load characteristics.
- 6 May 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 73
An experimental study on the equivalent nonlinear model for a large-sized tuned liquid damper
- 6 May 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 73
An experimental study on the equivalent nonlinear model for a large-sized tuned liquid damper
- Open Access
Development of a Water Supplement System for a Tuned Liquid Damper under Excitation
Integrating existing liquid storage and supply tanks in buildings with tuned liquid dampers (TLDs) are significant for reducing the effective cost of TLDs. However, existing water supplement devices for fire-suppression liquid tanks may overfill with water, which leads to TLD mistuning. To overcome this problem, a passive liquid control system named TLD with a stable replenishment sub-tank system (TLD-SRS) is proposed. The system, which consists of an additional sub-tank connected to the main tank and a floating ball, replenishes liquid in the TLD automatically. The system can avoid vibration interference and maintain the normal operation of the passive replenishment system under usual wind loads. According to the studies of tuned liquid column dampers (TLCD), the proposed TLD with a stable replenishment sub-tank system (TLD-SRS) uses simple devices to ensure that the liquid level in the TLD is steady at the target liquid level with a floating ball. The TLD-SRS is verified on a large-scale TLD shaking table experiment. The overshoot, which is the percentage of liquid that exceeds the target volume of TLD is calculated during sloshing with wind loads. Compared with TLD installed with a regular liquid replenishment device, the proposed TLD-SRS significantly reduces the overshoot of liquid and acceleration on the roof of the building.
Open AccessDevelopment of a Water Supplement System for a Tuned Liquid Damper under Excitation
Integrating existing liquid storage and supply tanks in buildings with tuned liquid dampers (TLDs) are significant for reducing the effective cost of TLDs. However, existing water supplement devices for fire-suppression liquid tanks may overfill with water, which leads to TLD mistuning. To overcome this problem, a passive liquid control system named TLD with a stable replenishment sub-tank system (TLD-SRS) is proposed. The system, which consists of an additional sub-tank connected to the main tank and a floating ball, replenishes liquid in the TLD automatically. The system can avoid vibration interference and maintain the normal operation of the passive replenishment system under usual wind loads. According to the studies of tuned liquid column dampers (TLCD), the proposed TLD with a stable replenishment sub-tank system (TLD-SRS) uses simple devices to ensure that the liquid level in the TLD is steady at the target liquid level with a floating ball. The TLD-SRS is verified on a large-scale TLD shaking table experiment. The overshoot, which is the percentage of liquid that exceeds the target volume of TLD is calculated during sloshing with wind loads. Compared with TLD installed with a regular liquid replenishment device, the proposed TLD-SRS significantly reduces the overshoot of liquid and acceleration on the roof of the building.