  • Open Access

    Influence of Rotational Speed on the Microstructure and Mechanical Response of ECO-AZ31 Magnesium Tubes Processed by Friction Stir Extrusion from Recycled Chips

    by Judit Medina, Pablo Perez, Paloma Adeva, Gerardo Garces

    ECO-AZ31 magnesium alloy modified with 1 wt.% CaO, was investigated for the production of thinwalled tubes by Friction Stir Extrusion (FSE), employing recycled chips through solid-state consolidation. The study focused on the influence of tool rotational speed, ranging from 500 to 1000 rpm, on the consolidation quality, microstructure and mechanical properties of the extruded tubes. The results indicate that low rotational speeds lead to poor material consolidation and surface defects due to insufficient heat generation, whereas high rotational speeds caused overheating and excessive grain growth. In contrast, intermediate rotational speeds were found to be optimal, as they resulted in defect-free tubes with a wall thickness of ~500 μm, exhibiting a refined microstructure (achieving grain sizes in the range of 5–7 μm in the inner region) and improved microhardness (with values close to 80 HV). Microstructural analysis revealed a heterogeneous microstructure throughout the tube wall thickness, associated with the thermal and deformation gradients. At intermediate rotational speeds, {10 1 2} tensile twinning was activated as the dominant mechanism of deformation accommodation, partially reducing dislocation accumulation and softening the texture, leading to a localized decrease in hardness despite the refined grain size. These results demonstrate that the combined effect of heat generation, plastic deformation, dynamic recrystallisation, and twinning determines the final tube properties, confirming FSE as a sustainable and energy-efficient route for producing thin-walled tubes from recycled machining chips.

  • Open Access

    Temporal Changes in Clinical Outcomes after Minimally Invasive Surgery for Hallux Valgus Correction in Women without Postoperative Complications

    by Luci M. Motta, Ignacio Manchado, Gustavo Blanco, María P. Quintana-Montesdeoca, Laura Garcés, Gerardo L. Garcés

    Minimally invasive surgery (MIS) is currently used to correct hallux valgus deformities. Most studies reporting on MIS techniques to correct hallux valgus deformities included patients with postoperative complications. These reported complications, with an average rate of 23%, had significant negative effects on the clinical outcomes in this patient population. In the present study, a cohort of 63 women who underwent MIS hallux valgus correction was assessed preoperatively and at a mean follow-up of 1.0, 4.7, and 6.5 years using the American Orthopaedic Foot and Ankle Society (AOFAS) scale and the Manchester Oxford Foot Questionnaire (MOXFQ). The main criterion for inclusion in this cohort was a lack of complications during the entire follow-up period. The results showed significant improvements in both AOFAS and MOXFQ scores between the preoperative and 1-year follow-up assessments. By contrast, clinically small and nonsignificant changes were observed among postoperative follow-up values. The number of enrolled patients needs to be increased in future studies, with different surgeons and techniques included. Nevertheless, our study findings will inform patients about the outcomes they can expect over the years if no complications occur.


  • Cross-cultural adaptation and validation of a Spanish version of the self-administered foot evaluation questionnaire (SAFE-Q)

    by Luci M. Motta, Ignacio Manchado, Gustavo Blanco, M. Pino Quintana-Montesdeoca, Laura Garcés, Gerardo L. Garcés


  • Open Access

    Isometric Knee Muscle Strength and Patient-Reported Measures Five Years after Anterior Cruciate Ligament Reconstruction: Comparison of Single versus Dual Autograft Hamstring Tendon Harvesting

    by Ignacio Manchado, Luci M. Motta, Gustavo Blanco, Jesús González, Gerardo L. Garcés

    There is some controversy regarding the use of one or two hamstring tendons for anterior cruciate ligament reconstruction (ACLR). In this study, two cohorts of 22 male patients underwent an ACLR with hamstring tendon autografts. One cohort was reconstructed through an all-inside technique with the semitendinosus tendon (ST group) and the other with the semitendinosus and gracilis tendons (ST-G group). Anterior tibial translation (ATT), Lysholm, and IKDC scores were assessed preoperatively and five years postoperation. Additionally, isometric knee muscle strength was manually measured in both groups and in another cohort of 22 uninjured control male subjects five years after the operation. There were no significant differences in ATT and Lysholm scores between the operated groups. The IKDC score was lower in the ST-G group than in the ST group—9.57 (CI 14.89–4.25) (p < 0.001). No significant differences between injured and uninjured knees were detected in hamstring to quadriceps ratio strength and quadriceps limb symmetry index of the two operated groups, but the hamstring limb symmetry index was significantly lower in the ST-G group than in the ST and control groups. This study shows that using an ST-G autograft for ACLR yielded less flexor strength and worse results in some patient-reported outcome measures (PROM) than using an ST autograft five years after the operation. The observed results let us suggest that the use of one autograft hamstring tendon for ACLR is clinically preferable to the use of two hamstring tendons.


  • Open Access

    Pre- and Post-Operative Relationship between Radiological Measures and Clinical Outcomes in Women with Hallux Valgus

    by Luci M. Motta, Ignacio Manchado, Gustavo Blanco, Felipe García-Flemate, Jesús González, Gerardo L. Garcés

    The surgical correction of a hallux valgus (HV) deformity improves radiological parameters and clinical outcomes. However, it is not known how these improvements are related between themselves. In this retrospective study, 73 women were assessed preoperatively and 60 months after HV surgical correction. Several radiological parameters were measured: the hallux valgus angle (HVA), I–II intermetatarsal angle (IMA) and sesamoid position. The functional outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) Hallux Metatarsophalangeal-Interphalangeal (HMI) scale, and patient-reported outcomes (PROMs) were recorded with the Manchester–Oxford Foot Questionnaire (MOXFQ). A pre–post-surgery comparison of radiological and clinical values was performed, the correlation among them was studied and the differences pre–post-surgery in the radiological measurements compared with those for the clinical outcomes were studied. The results show that all the radiological parameters, functional outcomes and PROMs improved significantly from their pre-operative values to the follow-up values. Multivariate regression analysis showed a significant relationship (p < 0.001) between the differential pre–post-surgery AOFAS scoring only with two sesamoid position differential pre–post-surgery measures: position of medial sesamoid (PMS) and translation of the first metatarsal head (TMH). However, no significant association was observed between the pre–post-surgery radiological differences and the pre–post-surgery MOXFQ scoring.


  • Open Access

    Correlation among Knee Muscle Strength and Self-Reported Outcomes Score, Anterior Tibial Displacement, and Time Post-Injury in Non-Coper Anterior Cruciate Ligament Deficient Patients: A Cross-Sectional Study

    by Ignacio Manchado, David Alvarez, Luci M. Motta, Gustavo Blanco, Pedro Saavedra, Gerardo L. Garcés

    Little attention has been paid to knee muscle strength after ACL rupture and its effect on prognostic outcomes and treatment decisions. We studied hamstrings (H) and quadriceps (Q) strength correlation with a patient-reported outcome measures score (International Knee Documentation Committee, IKDC), anterior tibial translation (ATT), and time post-injury in 194 anterior cruciate ligament deficient patients (ACLD) who required surgery after a failed rehabilitation program (non-copers). The correlation between knee muscle strength and ATT was also studied in 53 non-injured controls. ACLD patients showed decreased knee muscle strength of both the injured and non-injured limbs. The median (interquartile range) values of the H/Q ratio were 0.61 (0.52–0.81) for patients’ injured side and 0.65 (0.57–0.8) for the non-injured side (p = 0.010). The median H/Q ratio for the controls was 0.52 (0.45–0.66) on both knees (p < 0.001, compared with the non-injured side of patients). The H/Q, ATT, and time post-injury were not significantly correlated with the IKDC score. ATT was significantly correlated with the H/Q of the injured and non-injured knees of patients, but not in the knees of the controls. Quadriceps strength and H/Q ratio were significantly correlated with ATT for both limbs of the patients. IKDC score correlated significantly with the quadriceps and hamstrings strengths of the injured limb but not with the H/Q ratio, ATT or time passed after injury.


  • Open Access

    In Vitro Testing of 2 Adjustable-Loop Cortical Suspensory Fixation Systems Versus Interference Screw for Anterior Cruciate Ligament Reconstruction

    by Gerardo L. Garcés, Oscar Martel, Alejandro Yánez, Ignacio Manchado-Herrera, Luci M. Motta

    It is not clear whether the mechanical strength of adjustable-loop suspension devices (ALDs) in anterior cruciate ligament (ACL) reconstruction is device dependent and if these constructs are different from those of an interference screw. To compare the biomechanical differences of 2 types of ALDs versus an interference screw. Controlled laboratory study. ACL reconstruction was performed on porcine femurs and bovine extensor tendons with 3 types of fixation devices: interference screw, UltraButton (UB) ALD, and TightRope (TR) ALD (n = 10 for each). In addition to specimen testing, isolated testing of the 2 ALDs was performed. The loading protocol consisted of 3 stages: preload (static 150 N load for 5 minutes), cyclic load (50-250 N at 1 Hz for 1000 cycles), and load to failure (crosshead speed 50 mm/min). Displacement at different cycles, ultimate failure load, yield load, stiffness, and failure mode were recorded. In specimen testing, displacement of the ALDs at the 1000th cycle was similar (3.42 ± 1.34 mm for TR and 3.39 ± 0.92 mm for UB), but both were significantly lower than that of the interference screw (7.54 ± 3.18 mm) (P < .001 for both). The yield load of the UB (547 ± 173 N) was higher than that of the TR (420 ± 72 N) (P = .033) or the interference screw (386 ± 51 N; P = .013), with no significant difference between the latter 2. In isolated device testing, the ultimate failure load of the TR (862 ± 64 N) was significantly lower than that of the UB (1879 ± 126 N) (P < .001). Both ALDs showed significantly less displacement in cyclic loading at ultimate failure than the interference screw. The yield load of the UB was significantly higher than that of the other 2. The ultimate failure occurred at a significantly higher load for UB than it did for TR in isolated device testing. Both UB and TR provided stronger fixation than an interference screw. Although difficult to assess, intrinsic differences in the mechanical properties of these ALDs may affect clinical outcomes.