Qian Wan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qian Wan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Yan-Wu Wang
Huazhong University of Science and Technology
4 shared publications - Wu-Hua Chen
School of Electrical Engineering, Guangxi University, Nanning, China
3 shared publications - Wu Yang
School of Electrical Engineering, Guangxi University, Nanning, China
2 shared publications - Xiao-Kang Liu
Huazhong University of Science and Technology
2 shared publications - Xiaomei Lu
School of Mathematics and Information Science, Guangxi University, Nanning, China
2 shared publications - Andreas D. Syrmakesis
School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
1 shared publication
Latest Publications
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (3) , 2425-2437
Dynamic Self-Triggered Load Frequency Control for Multi-Area Power Systems Under Non-Ideal Communication Environments
Multi-area power systems (MAPSs) consist of multiple area subsystems, exchanging power between each area to maintain a balance of supply and demand. With the introduction of communication facilities, traditional load frequency control (LFC) methods and event-triggered communication mechanisms may not be effective due to network-induced delays and external attacks caused by non-ideal environments. In this paper, a decentralized LFC algorithm with a novel dynamic self-triggered mechanism (DSTM) for MAPSs under non-ideal communication environments is proposed to ensure secure operation. The proposed DSTM employs a dynamic threshold, a rest time interval and an internal dynamic variable, which can extend triggering intervals and effectively avoid Zeno behavior. An $H_{\infty }$ stability criterion and a co-design criterion are derived by a switching-based Lyapunov-Krasovskii functional. Comparison simulations and hardware-in-the-loop experiments verify the superiority and effectiveness of the proposed scheme.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (3) , 2425-2437
Dynamic Self-Triggered Load Frequency Control for Multi-Area Power Systems Under Non-Ideal Communication Environments
Multi-area power systems (MAPSs) consist of multiple area subsystems, exchanging power between each area to maintain a balance of supply and demand. With the introduction of communication facilities, traditional load frequency control (LFC) methods and event-triggered communication mechanisms may not be effective due to network-induced delays and external attacks caused by non-ideal environments. In this paper, a decentralized LFC algorithm with a novel dynamic self-triggered mechanism (DSTM) for MAPSs under non-ideal communication environments is proposed to ensure secure operation. The proposed DSTM employs a dynamic threshold, a rest time interval and an internal dynamic variable, which can extend triggering intervals and effectively avoid Zeno behavior. An $H_{\infty }$ stability criterion and a co-design criterion are derived by a switching-based Lyapunov-Krasovskii functional. Comparison simulations and hardware-in-the-loop experiments verify the superiority and effectiveness of the proposed scheme.
- 2 November 2025
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 362 (18)
Finite-time self-triggered load frequency control for multi-area interconnected power systems
- 2 November 2025
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 362 (18)
Finite-time self-triggered load frequency control for multi-area interconnected power systems
- 1 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (2) , 2916-2925
Impulsive Load Frequency Control for Multiarea Interconnected Power Systems With Network-Induced Delays
This article investigates the load frequency control (LFC) problem of multiarea power systems subject to network-induced delays. High-control cost is a drawback of conventional LFC algorithms, which is not conducive to energy saving requirements. This article proposes an impulsive control algorithm that acquires area control error information and implements control signals only at discrete instants to save control cost. Considering time delays induced by network communication, a novel system-augmentation-based modeling scheme is provided for the proposed LFC algorithms, such that the closed-loop system is augmented to a delay-free impulse-switching system. Moreover, switching-based discontinuous Lyapunov function is designed to capture the influence of delayed impulses on the stability and $\boldsymbol{H_{\infty}}$ performance of the interconnected power systems. Sufficient conditions for the exponential stability and $\boldsymbol{H_{\infty}}$ performance of the closed-loop system are presented. Further, impulse-delay-dependent design criteria guaranteeing exponential convergence and $\boldsymbol{H_{\infty}}$ performance are derived consequently. Low-energy consumption and effectiveness of the provided scheme are verified by numerical examples and a hardware-in-loop experiment test.
- 1 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (2) , 2916-2925
Impulsive Load Frequency Control for Multiarea Interconnected Power Systems With Network-Induced Delays
This article investigates the load frequency control (LFC) problem of multiarea power systems subject to network-induced delays. High-control cost is a drawback of conventional LFC algorithms, which is not conducive to energy saving requirements. This article proposes an impulsive control algorithm that acquires area control error information and implements control signals only at discrete instants to save control cost. Considering time delays induced by network communication, a novel system-augmentation-based modeling scheme is provided for the proposed LFC algorithms, such that the closed-loop system is augmented to a delay-free impulse-switching system. Moreover, switching-based discontinuous Lyapunov function is designed to capture the influence of delayed impulses on the stability and $\boldsymbol{H_{\infty}}$ performance of the interconnected power systems. Sufficient conditions for the exponential stability and $\boldsymbol{H_{\infty}}$ performance of the closed-loop system are presented. Further, impulse-delay-dependent design criteria guaranteeing exponential convergence and $\boldsymbol{H_{\infty}}$ performance are derived consequently. Low-energy consumption and effectiveness of the provided scheme are verified by numerical examples and a hardware-in-loop experiment test.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (4) , 3058-3069
New Insights on the Stability of Sampled-Data-Based LFC for Power Systems: A Delay-Interval-Dependent LKF Approach
This paper analyzes the stability problem of load frequency control (LFC) for power systems under uncertain transmission delays. First, an argumented LFC system model accounting for uncertainties in transmission delays is proposed. Then, a novel delay-interval-dependent Lyapunov-Krasovskii functional (LKF) that takes into account both the upper and lower bounds of the transmission delay is proposed. Several less conservative stability criteria are derived using the proposed LKF. Based on the stability criterion obtained, the sampling interval and the upper and lower bounds of the transmission delay are taken as the conditions to guide the controller design. Finally, case studies are conducted based on a one-area power system and a three-area power system, both integrated with wind and solar power generation. The simulation comparison results demonstrate that the proposed LFC scheme exhibits strong robustness against uncertain transmission delays, load fluctuations, and the intermittent generation of wind and solar power.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (4) , 3058-3069
New Insights on the Stability of Sampled-Data-Based LFC for Power Systems: A Delay-Interval-Dependent LKF Approach
This paper analyzes the stability problem of load frequency control (LFC) for power systems under uncertain transmission delays. First, an argumented LFC system model accounting for uncertainties in transmission delays is proposed. Then, a novel delay-interval-dependent Lyapunov-Krasovskii functional (LKF) that takes into account both the upper and lower bounds of the transmission delay is proposed. Several less conservative stability criteria are derived using the proposed LKF. Based on the stability criterion obtained, the sampling interval and the upper and lower bounds of the transmission delay are taken as the conditions to guide the controller design. Finally, case studies are conducted based on a one-area power system and a three-area power system, both integrated with wind and solar power generation. The simulation comparison results demonstrate that the proposed LFC scheme exhibits strong robustness against uncertain transmission delays, load fluctuations, and the intermittent generation of wind and solar power.
- 1 March 2024
- Published by Elsevier in ISA Transactions
- Vol. 148, 140-155
Impulsive consensus algorithms for vector second-order Lipschitz nonlinear multi-agent systems using only velocity regulation
- 1 March 2024
- Published by Elsevier in ISA Transactions
- Vol. 148, 140-155
Impulsive consensus algorithms for vector second-order Lipschitz nonlinear multi-agent systems using only velocity regulation
- 7 May 2023
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 111 (13) , 12213-12232
Secure consensus tracking of multi-agent systems with network-induced delays under deception attacks via guaranteed performance impulsive control
- 7 May 2023
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 111 (13) , 12213-12232
Secure consensus tracking of multi-agent systems with network-induced delays under deception attacks via guaranteed performance impulsive control
- Open Access
- 1 January 2011
- Published by Springer Nature in Advances in Difference Equations
- Vol. 2011 (1) , 1-14
Exponential Stability of Two Coupled Second-Order Evolution Equations
- 1 January 2011
- Published by Springer Nature in Advances in Difference Equations
- Vol. 2011 (1) , 1-14
Open AccessExponential Stability of Two Coupled Second-Order Evolution Equations