Philipp Schilk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Philipp Schilk has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Michele Magno
ETH Zurich
3 shared publications - Andrea Ronco
Eidgenössische Technische Hochschule Zürich (ETHZ), Switzerland
2 shared publications - Milos Cernak
Logitech Europe S.A Lausanne Switzerland
2 shared publications - Niccolò Polvani
École Polytechnique Fédérale Lausanne (EPFL), Switzerland and Logitech Europe, Switzerland
2 shared publications - Andrea Cossettini
Department of Information Technology and Electrical Engineering (D-ITET), ETH Zrich, Zrich, Switzerland
1 shared publication - Clénin Marc-André
PBL, D-ITET, ETH Zürich, Zürich, Switzerland
1 shared publication
Latest Publications
- Top Cited Papers
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (3) , 399-415
BioGAP-Ultra: A Modular Edge-AI Platform for Wearable Multimodal Biosignal Acquisition and Processing
The growing demand for continuous physiological monitoring and human-machine interaction in real-world settings calls for wearable platforms that are flexible, low-power, and capable of on-device intelligence. This work presents BioGAP-Ultra, an advanced multimodal biosensing platform that supports synchronized acquisition of diverse electrophysiological and hemodynamic signals such as EEG, EMG, ECG, and PPG while enabling embedded AI processing at state-of-the-art energy efficiency. BioGAP-Ultra is a major extension of our previous BioGAP design aimed at meeting the rapidly growing requirements of wearable biosensing applications. It features (i) increased on-device storage ($\times$2 SRAM, $\times$4 FLASH), (ii) improved wireless connectivity (supporting up to 1.4 Mbit/s bandwidth, $\times$4 higher than BioGAP), (iii) enhanced number of signal modalities (from 3 to 5) and analog input channels ($\times$2). Further, it is accompanied by a real-time visualization and analysis software suite that supports the hardware design, providing access to raw data and real-time configurability on a mobile phone. Finally, we demonstrate the system’s versatility through integration into various wearable form factors: an EEG-PPG headband consuming 32.8 mW, an EMG sleeve at 26.7 mW, and an ECG-PPG chestband requiring only 9.3 mW for continuous acquisition and streaming, tailored for diverse biosignal applications. To showcase its edge-AI capabilities, we further deploy two representative on-device applications: (1) ECG-PPG-based PAT estimation at 8.6 mW, and (2) EMG-ACC-based classification of reach-and-grasp motion phases, achieving 79.9 % $\pm$ 5.7 % accuracy at 23.6 mW. All hardware and software design files are also released open-source with a permissive license.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (3) , 399-415
Top Cited PapersBioGAP-Ultra: A Modular Edge-AI Platform for Wearable Multimodal Biosignal Acquisition and Processing
The growing demand for continuous physiological monitoring and human-machine interaction in real-world settings calls for wearable platforms that are flexible, low-power, and capable of on-device intelligence. This work presents BioGAP-Ultra, an advanced multimodal biosensing platform that supports synchronized acquisition of diverse electrophysiological and hemodynamic signals such as EEG, EMG, ECG, and PPG while enabling embedded AI processing at state-of-the-art energy efficiency. BioGAP-Ultra is a major extension of our previous BioGAP design aimed at meeting the rapidly growing requirements of wearable biosensing applications. It features (i) increased on-device storage ($\times$2 SRAM, $\times$4 FLASH), (ii) improved wireless connectivity (supporting up to 1.4 Mbit/s bandwidth, $\times$4 higher than BioGAP), (iii) enhanced number of signal modalities (from 3 to 5) and analog input channels ($\times$2). Further, it is accompanied by a real-time visualization and analysis software suite that supports the hardware design, providing access to raw data and real-time configurability on a mobile phone. Finally, we demonstrate the system’s versatility through integration into various wearable form factors: an EEG-PPG headband consuming 32.8 mW, an EMG sleeve at 26.7 mW, and an ECG-PPG chestband requiring only 9.3 mW for continuous acquisition and streaming, tailored for diverse biosignal applications. To showcase its edge-AI capabilities, we further deploy two representative on-device applications: (1) ECG-PPG-based PAT estimation at 8.6 mW, and (2) EMG-ACC-based classification of reach-and-grasp motion phases, achieving 79.9 % $\pm$ 5.7 % accuracy at 23.6 mW. All hardware and software design files are also released open-source with a permissive license.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 904-910
Earable and Wrist-worn Setup for Accurate Step Counting Utilizing Body-Area Electrostatic Sensing
Step-counting has been widely implemented in wrist-worn devices and is accepted by end users as a quantitative indicator of everyday exercise. However, existing counting approach (mostly on wrist-worn setup) lacks robustness and thus introduces inaccuracy issues in certain scenarios like brief intermittent walking bouts and random arm motions or static arm status while walking (no clear correlation of motion pattern between arm and leg). This paper proposes a low-power step-counting solution utilizing the body area electric field acquired by a novel electrostatic sensing unit, consuming only 87.3 µW of power, hoping to strengthen the robustness of current dominant solution. We designed two wearable devices for on-the-wrist and in-the-ear deployment and collected body-area electric field-derived motion signals from ten volunteers. Four walking scenarios are considered: in the parking lot/shopping center with/without pushing the shopping trolley. The step-counting accuracy from the prototypes shows better accuracy than the commercial wrist-worn devices (e.g.,96% of the wrist- and ear-worn prototype vs. 66% of the Fitbit when walking in the shopping center while pushing a shopping trolley). We finally discussed the potential and limitations of sensing body-area electric fields for wrist-worn and ear-worn step-counting and beyond.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 904-910
Open AccessEarable and Wrist-worn Setup for Accurate Step Counting Utilizing Body-Area Electrostatic Sensing
Step-counting has been widely implemented in wrist-worn devices and is accepted by end users as a quantitative indicator of everyday exercise. However, existing counting approach (mostly on wrist-worn setup) lacks robustness and thus introduces inaccuracy issues in certain scenarios like brief intermittent walking bouts and random arm motions or static arm status while walking (no clear correlation of motion pattern between arm and leg). This paper proposes a low-power step-counting solution utilizing the body area electric field acquired by a novel electrostatic sensing unit, consuming only 87.3 µW of power, hoping to strengthen the robustness of current dominant solution. We designed two wearable devices for on-the-wrist and in-the-ear deployment and collected body-area electric field-derived motion signals from ten volunteers. Four walking scenarios are considered: in the parking lot/shopping center with/without pushing the shopping trolley. The step-counting accuracy from the prototypes shows better accuracy than the commercial wrist-worn devices (e.g.,96% of the wrist- and ear-worn prototype vs. 66% of the Fitbit when walking in the shopping center while pushing a shopping trolley). We finally discussed the potential and limitations of sensing body-area electric fields for wrist-worn and ear-worn step-counting and beyond.
- Open Access
- 9 May 2023
- Published by Association for Computing Machinery (ACM)
- p. 488-490
Demo Abstract: In-Ear-Voice - Towards Milli-Watt Audio Enhancement With Bone-Conduction Microphones for In-Ear Sensing Platforms | Proceedings of the 8th ACM/IEEE Conference on Internet of Things Design and Implementation
This demonstration presents a custom-developed research platform for low-power wireless earbuds based on the cutting-edge Ambiq Apollo 4 Blue SoC, and targeted at applications in in-ear sensing and on-the-edge data processing. The earbud shown is currently equipped with a novel, commercial MEMS bone-conduction microphone. Such microphones can record the wearer’s speech with much greater isolation, enabling personalized voice activity detection and further audio enhancement applications. The device is running a specialized, TinyML-based, voice activity detection algorithm, indicating the wearer’s speech using an onboard LED. A second identical earbud attempts to do the same detection using a traditional air-conduction microphone is also shown to underline the advantage the bone-conduction microphone provides. Overall the platform achieves 2.64mW average power consumption at 14uJ per inference, reaching 43h of battery life on a miniature 32mAh li-ion cell without duty cycling.
- 9 May 2023
- Published by Association for Computing Machinery (ACM)
- p. 488-490
Open AccessDemo Abstract: In-Ear-Voice - Towards Milli-Watt Audio Enhancement With Bone-Conduction Microphones for In-Ear Sensing Platforms | Proceedings of the 8th ACM/IEEE Conference on Internet of Things Design and Implementation
This demonstration presents a custom-developed research platform for low-power wireless earbuds based on the cutting-edge Ambiq Apollo 4 Blue SoC, and targeted at applications in in-ear sensing and on-the-edge data processing. The earbud shown is currently equipped with a novel, commercial MEMS bone-conduction microphone. Such microphones can record the wearer’s speech with much greater isolation, enabling personalized voice activity detection and further audio enhancement applications. The device is running a specialized, TinyML-based, voice activity detection algorithm, indicating the wearer’s speech using an onboard LED. A second identical earbud attempts to do the same detection using a traditional air-conduction microphone is also shown to underline the advantage the bone-conduction microphone provides. Overall the platform achieves 2.64mW average power consumption at 14uJ per inference, reaching 43h of battery life on a miniature 32mAh li-ion cell without duty cycling.
- Open Access
- 9 May 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-12
In-Ear-Voice: Towards Milli-Watt Audio Enhancement With Bone-Conduction Microphones for In-Ear Sensing Platforms
The recent ubiquitous adoption of remote conferencing has been accompanied by omnipresent frustration with distorted or otherwise unclear voice communication. Audio enhancement can compensate for low-quality input signals from, for example, small true wireless earbuds, by applying noise suppression techniques. Such processing relies on voice activity detection (VAD) with low latency and the added capability of discriminating the wearer’s voice from others - a task of significant computational complexity. The tight energy budget of devices as small as modern earphones, however, requires any system attempting to tackle this problem to do so with minimal power and processing overhead, while not relying on speaker-specific voice samples and training due to usability concerns. This paper presents the design and implementation of a custom research platform for low-power wireless earbuds based on novel, commercial, MEMS bone-conduction microphones. Such microphones can record the wearer’s speech with much greater isolation, enabling personalized voice activity detection and further audio enhancement applications. Furthermore, the paper accurately evaluates a proposed low-power personalized speech detection algorithm based on bone conduction data and a recurrent neural network running on the implemented research platform. This algorithm is compared to an approach based on traditional microphone input. The performance of the bone conduction system, achieving detection of speech within 12.8ms at an accuracy of 95% is evaluated. Different SoC choices are contrasted, with the final implementation based on the cutting-edge Ambiq Apollo 4 Blue SoC achieving 2.64mW average power consumption at 14uJ per inference, reaching 43h of battery life on a miniature 32mAh li-ion cell and without duty cycling.
- 9 May 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-12
Open AccessIn-Ear-Voice: Towards Milli-Watt Audio Enhancement With Bone-Conduction Microphones for In-Ear Sensing Platforms
The recent ubiquitous adoption of remote conferencing has been accompanied by omnipresent frustration with distorted or otherwise unclear voice communication. Audio enhancement can compensate for low-quality input signals from, for example, small true wireless earbuds, by applying noise suppression techniques. Such processing relies on voice activity detection (VAD) with low latency and the added capability of discriminating the wearer’s voice from others - a task of significant computational complexity. The tight energy budget of devices as small as modern earphones, however, requires any system attempting to tackle this problem to do so with minimal power and processing overhead, while not relying on speaker-specific voice samples and training due to usability concerns. This paper presents the design and implementation of a custom research platform for low-power wireless earbuds based on novel, commercial, MEMS bone-conduction microphones. Such microphones can record the wearer’s speech with much greater isolation, enabling personalized voice activity detection and further audio enhancement applications. Furthermore, the paper accurately evaluates a proposed low-power personalized speech detection algorithm based on bone conduction data and a recurrent neural network running on the implemented research platform. This algorithm is compared to an approach based on traditional microphone input. The performance of the bone conduction system, achieving detection of speech within 12.8ms at an accuracy of 95% is evaluated. Different SoC choices are contrasted, with the final implementation based on the cutting-edge Ambiq Apollo 4 Blue SoC achieving 2.64mW average power consumption at 14uJ per inference, reaching 43h of battery life on a miniature 32mAh li-ion cell and without duty cycling.