Runze Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Runze Liu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Mahanth Gowda
Computer Science and Engineering, Pennsylvania State University, University Park, Pennsylvania, USA
8 shared publications - Taiting Lu
Pennsylvania State University, University Park, Pennsylvania, USA
8 shared publications - Hao Zhou
Pennsylvania State University, State College, USA
3 shared publications - Shengming Yuan
Pennsylvania State University, State College, Pennsylvania, USA
3 shared publications - Zhenghao Li
Pennsylvania State University, University Park, Pennsylvania, USA
3 shared publications - Alexander Achberger
University of Stuttgart, Stuttgart, Germany
2 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-13
iRing: Rich Interaction on Smart Ring with Multi-point Capacitive Touch Screen
- 2 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-13
Open AccessiRing: Rich Interaction on Smart Ring with Multi-point Capacitive Touch Screen
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-37
AquaTag: An Open-Source Wearable Platform Enabling Flexible Sensor Placement for Aquatic Sensing
Commercial swim wearables increasingly provide performance feedback but remain restricted by fixed, single-placement designs. When worn outside their intended location, the accuracy of motion recognition and swimming analysis drops sharply. Moreover, most existing devices are closed-source, limiting access to raw sensor data and hindering reproducibility and innovation in aquatic HCI research. To address these limitations, we present AquaTag, an open-source aquatic wearable platform that enables flexible placement and consistent motion analysis across different locations. The AquaTag integrates a motion sensor, barometer, and temperature sensor. Using a documented epoxy-potting workflow adapted from established underwater electronics practices, it remains functional during a controlled pressure test equivalent to approximately 14 m water depth for 30 minutes. To support underwater use, AquaTag offers NOR flash or microSD storage for offline logging and Bluetooth for above-water data synchronization. Its power system provides up to 4.4 hours of offline logging or 7.8 hours of non-submerged streaming. The power control and charging mechanisms are designed to meet the waterproofing requirements of the device. The hardware can be manufactured at about $40 per unit. A companion software suite is also developed to annotate and analyze motion data. Specifically, our contributions include: (1) a compact, robust sensing module with a documented, low-cost waterproof packaging workflow suitable for rapid in-house fabrication; and (2) a placement-adaptive machine learning pipeline that delivers accurate swimming analytics from a single motion sensor at flexible body locations. By conditioning a deep learning backbone on the sensor's mounting position, our model learns to infer swimmer kinematics when worn on the head, wrist, or lower back. In leave-one-subject-out evaluation, AquaTag achieved mean macro- F 1 scores of 91.7% for stroke-type classification and 90.6% for swim-state classification across the head, lower-back, and wrist placements; the corresponding best-placement scores were 96.5% and 92.2%, respectively. The AquaTag hardware designs, PCB files, bill of materials, firmware, enclosure CAD files, fabrication instructions, and companion application are released publicly.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-37
Open AccessAquaTag: An Open-Source Wearable Platform Enabling Flexible Sensor Placement for Aquatic Sensing
Commercial swim wearables increasingly provide performance feedback but remain restricted by fixed, single-placement designs. When worn outside their intended location, the accuracy of motion recognition and swimming analysis drops sharply. Moreover, most existing devices are closed-source, limiting access to raw sensor data and hindering reproducibility and innovation in aquatic HCI research. To address these limitations, we present AquaTag, an open-source aquatic wearable platform that enables flexible placement and consistent motion analysis across different locations. The AquaTag integrates a motion sensor, barometer, and temperature sensor. Using a documented epoxy-potting workflow adapted from established underwater electronics practices, it remains functional during a controlled pressure test equivalent to approximately 14 m water depth for 30 minutes. To support underwater use, AquaTag offers NOR flash or microSD storage for offline logging and Bluetooth for above-water data synchronization. Its power system provides up to 4.4 hours of offline logging or 7.8 hours of non-submerged streaming. The power control and charging mechanisms are designed to meet the waterproofing requirements of the device. The hardware can be manufactured at about $40 per unit. A companion software suite is also developed to annotate and analyze motion data. Specifically, our contributions include: (1) a compact, robust sensing module with a documented, low-cost waterproof packaging workflow suitable for rapid in-house fabrication; and (2) a placement-adaptive machine learning pipeline that delivers accurate swimming analytics from a single motion sensor at flexible body locations. By conditioning a deep learning backbone on the sensor's mounting position, our model learns to infer swimmer kinematics when worn on the head, wrist, or lower back. In leave-one-subject-out evaluation, AquaTag achieved mean macro- F 1 scores of 91.7% for stroke-type classification and 90.6% for swim-state classification across the head, lower-back, and wrist placements; the corresponding best-placement scores were 96.5% and 92.2%, respectively. The AquaTag hardware designs, PCB files, bill of materials, firmware, enclosure CAD files, fabrication instructions, and companion application are released publicly.
- Open Access
- 2 December 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (4) , 1-34
FuSenseRing: An Open-Source Platform for Robust Cuffless Blood Pressure Monitoring via Multimodal Sensor Fusion and Temperature-Adaptive Attention
Reliable, frequent blood pressure (BP) monitoring outside clinical settings is crucial for cardiovascular health management, yet current wearable solutions often fail to deliver clinically accurate measurements in real-world conditions. A key limitation stems from the common reliance, particularly in convenient ring form factors, on photoplethysmography (PPG) sensing alone. PPG signals acquired from the finger are highly susceptible to physiological and environmental noise; notably, finger skin temperature fluctuations induce errors exceeding 10 mmHg due to vascular changes, while sensor-skin contact pressure further distorts the signal. This inherent sensitivity of PPG, when uncompensated, prevents many devices from consistently meeting clinical accuracy standards. We introduce FuSenseRing , an open-source smart ring engineered to overcome these issues through synergistic hardware-software co-design. FuSenseRing integrates a multimodal sensor suite (PPG, ECG, skin temperature, contact force) on a custom flexible PCB within a low-cost form factor, approximately $94.9 per unit at retail (batch of 5) and approximately $28.72 per unit at wholesale (batch of 500), while remaining lightweight (4.6 g) to ensure optimal signal acquisition during BP measurements. Our core algorithmic innovation is a Temperature-Adaptive Attention (TAA) mechanism that dynamically fuses PPG/ECG features and recalibrates their contributions using real-time temperature context to specifically mitigate thermal drift. Efficient personalization via transfer learning requires only 5-10 normal-temperature calibration samples. Through rigorous evaluations involving total 60 participants across diverse laboratory-controlled temperatures (17 °C to 40 °C skin temp) and challenging real-world ambulatory conditions (-10 °C to 24.4 °C ambient temp), we demonstrate FuSenseRing's effectiveness. Our system maintains high accuracy across the full temperature range (Overall SBP/DBP ME±STD: -0.09 ± 7.67 / 0.42 ± 5.74 mmHg), satisfying the stringent accuracy criteria of the FDA-recognized AAMI/ISO 81060-2 standard. Furthermore, FuSenseRing significantly outperformed three popular commercial BP rings in the real-world study.
- 2 December 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (4) , 1-34
Open AccessFuSenseRing: An Open-Source Platform for Robust Cuffless Blood Pressure Monitoring via Multimodal Sensor Fusion and Temperature-Adaptive Attention
Reliable, frequent blood pressure (BP) monitoring outside clinical settings is crucial for cardiovascular health management, yet current wearable solutions often fail to deliver clinically accurate measurements in real-world conditions. A key limitation stems from the common reliance, particularly in convenient ring form factors, on photoplethysmography (PPG) sensing alone. PPG signals acquired from the finger are highly susceptible to physiological and environmental noise; notably, finger skin temperature fluctuations induce errors exceeding 10 mmHg due to vascular changes, while sensor-skin contact pressure further distorts the signal. This inherent sensitivity of PPG, when uncompensated, prevents many devices from consistently meeting clinical accuracy standards. We introduce FuSenseRing , an open-source smart ring engineered to overcome these issues through synergistic hardware-software co-design. FuSenseRing integrates a multimodal sensor suite (PPG, ECG, skin temperature, contact force) on a custom flexible PCB within a low-cost form factor, approximately $94.9 per unit at retail (batch of 5) and approximately $28.72 per unit at wholesale (batch of 500), while remaining lightweight (4.6 g) to ensure optimal signal acquisition during BP measurements. Our core algorithmic innovation is a Temperature-Adaptive Attention (TAA) mechanism that dynamically fuses PPG/ECG features and recalibrates their contributions using real-time temperature context to specifically mitigate thermal drift. Efficient personalization via transfer learning requires only 5-10 normal-temperature calibration samples. Through rigorous evaluations involving total 60 participants across diverse laboratory-controlled temperatures (17 °C to 40 °C skin temp) and challenging real-world ambulatory conditions (-10 °C to 24.4 °C ambient temp), we demonstrate FuSenseRing's effectiveness. Our system maintains high accuracy across the full temperature range (Overall SBP/DBP ME±STD: -0.09 ± 7.67 / 0.42 ± 5.74 mmHg), satisfying the stringent accuracy criteria of the FDA-recognized AAMI/ISO 81060-2 standard. Furthermore, FuSenseRing significantly outperformed three popular commercial BP rings in the real-world study.
- Open Access
- 27 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-4
Demonstration of VisRing: A Display-Extended Smartring for Nano Visualizations
- 27 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-4
Open AccessDemonstration of VisRing: A Display-Extended Smartring for Nano Visualizations
- Open Access
- 27 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-18
VisRing: A Display-Extended Smartring for Nano Visualizations
- 27 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-18
Open AccessVisRing: A Display-Extended Smartring for Nano Visualizations
- Open Access
- 22 August 2024
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 8 (3) , 1-30
SmartDampener: An Open Source Platform for Sport Analytics in Tennis
In this paper, we introduce SmartDampener, an open-source tennis analytics platform that redefines the traditional understanding of vibration dampeners. Traditional vibration dampeners favored by both amateur and professional tennis players are utilized primarily to diminish vibration transmission and enhance racket stability. However, our platform uniquely merges wireless sensing technologies into a device that resembles a conventional vibration dampener, thereby offering a range of tennis performance metrics including ball speed, impact location, and stroke type. The design of SmartDampener adheres to the familiar form of this accessory, ensuring that (i) it is readily accepted by users and robust under real-play conditions such as ball-hitting, (ii) it has minimal impact on player performance, (iii) it is capable of providing a wide range of analytical insights, and (iv) it is extensible to other sports. Existing computer vision systems for tennis sensing such as Hawk-eye and PlaySight, rely on hardware that costs millions of US dollars to deploy with complex setup procedures and is susceptible to lighting environment. Wearable devices and other tennis sensing accessories, such as Zepp Tennis sensor and TennisEye, using intrusive mounting locations, hinder user experience and impede player performance. In contrast, SmartDampener, a low-cost and compact tennis sensing device, notable for its socially accepted, lightweight and scalable design, seamlessly melds into the form of a vibration dampener. SmartDampener exploits opportunities in SoC and form factor design of conventional dampeners to integrate the sensing units and micro-controllers on a two-layer flexible PCB, that is bent and enclosed inside a dampener case made of 3D printing TPU material, while maintaining the vibration dampening feature and further being enhanced by its extended battery life and the inclusion of wireless communication features. The overall cost is $9.42, with a dimension of 21.4 mm × 27.5 mm × 9.7 mm (W × L × H) and a weight of 6.1 g and 5.8 hours of battery life. In proof of SmartDampener's performance in tennis analytics, we present various tennis analytic applications that exploit the capability of SmartDampener in capturing the correlations across string vibration, and racket motion, including the estimation of ball speed with a median error of 3.59 mph, estimation of ball impact location with accuracy of 3.03 cm, and classification of six tennis strokes with accuracy of 96.75%. Finally, extensive usability studies with 15 tennis players indicate high levels of social acceptance of form factor design for the SmartDampener dampener in comparison with alternative form factors, as well as its capability of sensing and analyzing tennis stroke in an accurate and robust manner. We believe this platform will enable exciting applications in other sports like badminton, fitness tracking, and injury prevention.
- 22 August 2024
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 8 (3) , 1-30
Open AccessSmartDampener: An Open Source Platform for Sport Analytics in Tennis
In this paper, we introduce SmartDampener, an open-source tennis analytics platform that redefines the traditional understanding of vibration dampeners. Traditional vibration dampeners favored by both amateur and professional tennis players are utilized primarily to diminish vibration transmission and enhance racket stability. However, our platform uniquely merges wireless sensing technologies into a device that resembles a conventional vibration dampener, thereby offering a range of tennis performance metrics including ball speed, impact location, and stroke type. The design of SmartDampener adheres to the familiar form of this accessory, ensuring that (i) it is readily accepted by users and robust under real-play conditions such as ball-hitting, (ii) it has minimal impact on player performance, (iii) it is capable of providing a wide range of analytical insights, and (iv) it is extensible to other sports. Existing computer vision systems for tennis sensing such as Hawk-eye and PlaySight, rely on hardware that costs millions of US dollars to deploy with complex setup procedures and is susceptible to lighting environment. Wearable devices and other tennis sensing accessories, such as Zepp Tennis sensor and TennisEye, using intrusive mounting locations, hinder user experience and impede player performance. In contrast, SmartDampener, a low-cost and compact tennis sensing device, notable for its socially accepted, lightweight and scalable design, seamlessly melds into the form of a vibration dampener. SmartDampener exploits opportunities in SoC and form factor design of conventional dampeners to integrate the sensing units and micro-controllers on a two-layer flexible PCB, that is bent and enclosed inside a dampener case made of 3D printing TPU material, while maintaining the vibration dampening feature and further being enhanced by its extended battery life and the inclusion of wireless communication features. The overall cost is $9.42, with a dimension of 21.4 mm × 27.5 mm × 9.7 mm (W × L × H) and a weight of 6.1 g and 5.8 hours of battery life. In proof of SmartDampener's performance in tennis analytics, we present various tennis analytic applications that exploit the capability of SmartDampener in capturing the correlations across string vibration, and racket motion, including the estimation of ball speed with a median error of 3.59 mph, estimation of ball impact location with accuracy of 3.03 cm, and classification of six tennis strokes with accuracy of 96.75%. Finally, extensive usability studies with 15 tennis players indicate high levels of social acceptance of form factor design for the SmartDampener dampener in comparison with alternative form factors, as well as its capability of sensing and analyzing tennis stroke in an accurate and robust manner. We believe this platform will enable exciting applications in other sports like badminton, fitness tracking, and injury prevention.
- Open Access
- 16 December 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Internet of Things
- Vol. 5 (1) , 1-29
I Am an Earphone and I Can Hear My User’s Face: Facial Landmark Tracking Using Smart Earphones
This article presents EARFace , a system that shows the feasibility of tracking facial landmarks for 3D facial reconstruction using in-ear acoustic sensors embedded within smart earphones. This enables a number of applications in the areas of facial expression tracking, user interfaces, AR/VR applications, affective computing, and accessibility, among others. Although conventional vision-based solutions break down under poor lighting and occlusions, and also suffer from privacy concerns, earphone platforms are robust to ambient conditions while being privacy-preserving. In contrast to prior work on earable platforms that perform outer-ear sensing for facial motion tracking, EARFace shows the feasibility of completely in-ear sensing with a natural earphone form factor, thus enhancing the comfort levels of wearing. The core intuition exploited by EARFace is that the shape of the ear canal changes due to the movement of facial muscles during facial motion. EARFace tracks the changes in shape of the ear canal by measuring ultrasonic channel frequency response of the inner ear, ultimately resulting in tracking of the facial motion. A transformer-based machine learning model is designed to exploit spectral and temporal relationships in the ultrasonic channel frequency response data to predict the facial landmarks of the user with an accuracy of 1.83 mm. Using these predicted landmarks, a 3D graphical model of the face that replicates the precise facial motion of the user is then reconstructed. Domain adaptation is further performed by adapting the weights of layers using a group-wise and differential learning rate. This decreases the training overhead in EARFace . The transformer-based machine learning model runs on smart phone devices with a processing latency of 13 ms and an overall low power consumption profile. Finally, usability studies indicate higher levels of comforts of wearing EARFace ’s earphone platform in comparison with alternative form factors.
- 16 December 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Internet of Things
- Vol. 5 (1) , 1-29
Open AccessI Am an Earphone and I Can Hear My User’s Face: Facial Landmark Tracking Using Smart Earphones
This article presents EARFace , a system that shows the feasibility of tracking facial landmarks for 3D facial reconstruction using in-ear acoustic sensors embedded within smart earphones. This enables a number of applications in the areas of facial expression tracking, user interfaces, AR/VR applications, affective computing, and accessibility, among others. Although conventional vision-based solutions break down under poor lighting and occlusions, and also suffer from privacy concerns, earphone platforms are robust to ambient conditions while being privacy-preserving. In contrast to prior work on earable platforms that perform outer-ear sensing for facial motion tracking, EARFace shows the feasibility of completely in-ear sensing with a natural earphone form factor, thus enhancing the comfort levels of wearing. The core intuition exploited by EARFace is that the shape of the ear canal changes due to the movement of facial muscles during facial motion. EARFace tracks the changes in shape of the ear canal by measuring ultrasonic channel frequency response of the inner ear, ultimately resulting in tracking of the facial motion. A transformer-based machine learning model is designed to exploit spectral and temporal relationships in the ultrasonic channel frequency response data to predict the facial landmarks of the user with an accuracy of 1.83 mm. Using these predicted landmarks, a 3D graphical model of the face that replicates the precise facial motion of the user is then reconstructed. Domain adaptation is further performed by adapting the weights of layers using a group-wise and differential learning rate. This decreases the training overhead in EARFace . The transformer-based machine learning model runs on smart phone devices with a processing latency of 13 ms and an overall low power consumption profile. Finally, usability studies indicate higher levels of comforts of wearing EARFace ’s earphone platform in comparison with alternative form factors.
- Open Access
- 9 May 2023
- Published by Association for Computing Machinery (ACM)
- p. 27-38
One Ring to Rule Them All: An Open Source Smartring Platform for Finger Motion Analytics and Healthcare Applications
This paper presents OmniRing, an open-source smartring platform with IMU and PPG sensors for activity tracking and health analytics applications. Smartring platforms are on the rise because of comfortable wearing, with the market size expected to reach $92 million soon. Nevertheless, most existing platforms are either commercial and proprietary without details of software/hardware or use suboptimal PCB design resulting in bulky form factors, inconvenient for wearing in daily life. Towards bridging the gap, OmniRing presents an extensible design of a smartring with a miniature form factor, longer battery life, wireless communication, and water resistance so that users can wear it all the time. Towards this end, OmniRing exploits opportunities in SoC, and carefully integrates the sensing units with a microcontroller and BLE modules. The electronic components are integrated on both sides of a flexible PCB that is bent in the shape of a ring and enclosed in a flexible and waterproof case for smooth skin contact. The overall cost is under $25, with weight of 2.5g, and up to a week of battery life. Extensive usability surveys validate the comfort levels. To validate the sensing capabilities, we enable an application in 3D finger motion tracking. By extracting synthetic training data from public videos coupled with data augmentation to minimize the overhead of training data generation for a new platform, OmniRing designs a transformer-based model that exploits correlations across fingers and time to track 3D finger motion with an accuracy of 6.57mm. We also validate the use of PPG data from OmniRing for heart rate monitoring. We believe the platform can enable exciting applications in fitness tracking, metaverse, sports, and healthcare.
- 9 May 2023
- Published by Association for Computing Machinery (ACM)
- p. 27-38
Open AccessOne Ring to Rule Them All: An Open Source Smartring Platform for Finger Motion Analytics and Healthcare Applications
This paper presents OmniRing, an open-source smartring platform with IMU and PPG sensors for activity tracking and health analytics applications. Smartring platforms are on the rise because of comfortable wearing, with the market size expected to reach $92 million soon. Nevertheless, most existing platforms are either commercial and proprietary without details of software/hardware or use suboptimal PCB design resulting in bulky form factors, inconvenient for wearing in daily life. Towards bridging the gap, OmniRing presents an extensible design of a smartring with a miniature form factor, longer battery life, wireless communication, and water resistance so that users can wear it all the time. Towards this end, OmniRing exploits opportunities in SoC, and carefully integrates the sensing units with a microcontroller and BLE modules. The electronic components are integrated on both sides of a flexible PCB that is bent in the shape of a ring and enclosed in a flexible and waterproof case for smooth skin contact. The overall cost is under $25, with weight of 2.5g, and up to a week of battery life. Extensive usability surveys validate the comfort levels. To validate the sensing capabilities, we enable an application in 3D finger motion tracking. By extracting synthetic training data from public videos coupled with data augmentation to minimize the overhead of training data generation for a new platform, OmniRing designs a transformer-based model that exploits correlations across fingers and time to track 3D finger motion with an accuracy of 6.57mm. We also validate the use of PPG data from OmniRing for heart rate monitoring. We believe the platform can enable exciting applications in fitness tracking, metaverse, sports, and healthcare.