Rodolfo Carobene
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rodolfo Carobene has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Giachero
Dipartimento di Fisica, Università di Milano-Bicocca, I-20126 Milano, Italy
9 shared publications - Danilo Labranca
Dipartimento di Fisica “Giuseppe Occhialini”, Università degli Studi di Milano-Bicocca, Milano, Italy
6 shared publications - Elena Ferri
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano Bicocca, Milano, Italy
6 shared publications - Marco Faverzani
Dipartimento di Fisica “Giuseppe Occhialini”, Università degli Studi di Milano-Bicocca, Milano, Italy
6 shared publications - Marco Gobbo
Dipartimento di Fisica “Giuseppe Occhialini”, Università degli Studi di Milano-Bicocca, Milano, Italy
6 shared publications - Matteo Borghesi
Dipartimento di Fisica “Giuseppe Occhialini”, Università degli Studi di Milano-Bicocca, Milano, Italy
6 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 141 (10) , 1176
Demonstration of a cryogenic, switchable electron source for low-temperature detector calibration
We present the realization of a prototype of a compact, switchable electron source operating at cryogenic temperatures, demonstrated at energies ranging from 100 eV to 300 eV, and conceptually extendable to an arbitrary energy range. The electrons are produced via photoelectric emission, induced by a LED illuminating two 400-nm-thick commercial aluminum layers inside a cryostat, and are subsequently accelerated by a voltage of up to 300 V. Detection is carried out with an array of transition-edge sensor (TES) microcalorimeters designed for X-ray detectors, where we successfully observe signals consistent with electrons produced at the source at rates of $$\gtrsim$$ 1 Hz and with an efficiency of $$\gtrsim 10^{-14}\ e^-/\gamma$$ .- 14 October 2026
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 141 (10) , 1176
Open AccessDemonstration of a cryogenic, switchable electron source for low-temperature detector calibration
We present the realization of a prototype of a compact, switchable electron source operating at cryogenic temperatures, demonstrated at energies ranging from 100 eV to 300 eV, and conceptually extendable to an arbitrary energy range. The electrons are produced via photoelectric emission, induced by a LED illuminating two 400-nm-thick commercial aluminum layers inside a cryostat, and are subsequently accelerated by a voltage of up to 300 V. Detection is carried out with an array of transition-edge sensor (TES) microcalorimeters designed for X-ray detectors, where we successfully observe signals consistent with electrons produced at the source at rates of $$\gtrsim$$ 1 Hz and with an efficiency of $$\gtrsim 10^{-14}\ e^-/\gamma$$ . - Open Access
- 23 March 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (3)
Phenomenological modeling of the 163Ho calorimetric electron capture spectrum from the HOLMES experiment
A bstract: We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of 163 Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing 163 Ho, supporting both data analysis and experimental design.
- 23 March 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (3)
Open AccessPhenomenological modeling of the 163Ho calorimetric electron capture spectrum from the HOLMES experiment
A bstract: We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of 163 Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing 163 Ho, supporting both data analysis and experimental design.
- Open Access
- 14 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Quantum Engineering
- Vol. 7, 1-8
Transmon Qubit Modeling and Characterization for Dark Matter Search
This study presents the design, simulation, and experimental characterization of a superconducting transmon qubit circuit prototype for potential applications in dark matter detection experiments. We describe a planar circuit design featuring two noninteracting transmon qubits, one with fixed frequency and the other flux tunable. Finite-element simulations were employed to extract key Hamiltonian parameters and optimize component geometries. The qubit was fabricated and then characterized at 20 mK, allowing for a comparison between simulated and measured qubit parameters. Good agreement was found for transition frequencies and anharmonicities (within 1% and 10%, respectively) while coupling strengths exhibited larger discrepancies (30%). We discuss potential causes for measured coherence times falling below expectations ($T_{1}\sim \,$1–2 μs) and propose strategies for future design improvements. Notably, we demonstrate the application of a hybrid 3D–2D simulation approach for energy participation ratio evaluation, yielding a more accurate estimation of dielectric losses. This work represents an important first step in developing planar quantum nondemolition single-photon counters for dark matter searches, particularly for axion and dark photon detection schemes.
- 14 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Quantum Engineering
- Vol. 7, 1-8
Open AccessTransmon Qubit Modeling and Characterization for Dark Matter Search
This study presents the design, simulation, and experimental characterization of a superconducting transmon qubit circuit prototype for potential applications in dark matter detection experiments. We describe a planar circuit design featuring two noninteracting transmon qubits, one with fixed frequency and the other flux tunable. Finite-element simulations were employed to extract key Hamiltonian parameters and optimize component geometries. The qubit was fabricated and then characterized at 20 mK, allowing for a comparison between simulated and measured qubit parameters. Good agreement was found for transition frequencies and anharmonicities (within 1% and 10%, respectively) while coupling strengths exhibited larger discrepancies (30%). We discuss potential causes for measured coherence times falling below expectations ($T_{1}\sim \,$1–2 μs) and propose strategies for future design improvements. Notably, we demonstrate the application of a hybrid 3D–2D simulation approach for energy participation ratio evaluation, yielding a more accurate estimation of dielectric losses. This work represents an important first step in developing planar quantum nondemolition single-photon counters for dark matter searches, particularly for axion and dark photon detection schemes.
- Open Access
- 30 September 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (9) , 1-9
Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experimentWe present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $$^{163}$$ Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $$^{163}$$ Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector’s energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $$^{163}$$ Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $$^{163}$$ Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $$^{163}$$ Ho to be $$(2.9 \pm 0.4 \mathrm {(stat)} \pm 0.7 \mathrm {(sys)})$$ J/K/mol at $$(94 \pm 1)$$ mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $$^{163}$$ Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $$^{163}$$ Ho activities up to approximately 5 Bq, with only about a factor of three degradation in performance compared to detectors without $$^{163}$$ Ho. For higher activities, reducing the TES transition temperature is necessary to maintain or improve the energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling limited amounts of implanted radionuclides while maintaining high-resolution performance.- 30 September 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (9) , 1-9
Open AccessImpact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experimentWe present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $$^{163}$$ Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $$^{163}$$ Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector’s energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $$^{163}$$ Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $$^{163}$$ Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $$^{163}$$ Ho to be $$(2.9 \pm 0.4 \mathrm {(stat)} \pm 0.7 \mathrm {(sys)})$$ J/K/mol at $$(94 \pm 1)$$ mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $$^{163}$$ Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $$^{163}$$ Ho activities up to approximately 5 Bq, with only about a factor of three degradation in performance compared to detectors without $$^{163}$$ Ho. For higher activities, reducing the TES transition temperature is necessary to maintain or improve the energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling limited amounts of implanted radionuclides while maintaining high-resolution performance. - Open Access
- 29 September 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (14) , 141801
Most Stringent Bound on Electron Neutrino Mass Obtained with a Scalable Low-Temperature Microcalorimeter Array
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the standard model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. Here we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of Ho 163 . The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of 7 × 10 7 decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of m β < 27 eV / c 2 at 90% credibility. These results validate the feasibility of Ho 163 calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.
- 29 September 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (14) , 141801
Open AccessMost Stringent Bound on Electron Neutrino Mass Obtained with a Scalable Low-Temperature Microcalorimeter Array
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the standard model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. Here we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of Ho 163 . The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of 7 × 10 7 decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of m β < 27 eV / c 2 at 90% credibility. These results validate the feasibility of Ho 163 calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.
- 19 September 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (3)
Local fermion-to-qudit mappings: A practical recipe for four-level systems
- 19 September 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (3)
Local fermion-to-qudit mappings: A practical recipe for four-level systems
- Open Access
An Array of Bulk Acoustic Wave Sensors as a High-Frequency Antenna for Gravitational Waves
In their simplest form, bulk acoustic wave (BAW) devices consist of a piezoelectric crystal between two electrodes that transduce the material’s vibrations into electrical signals. They are adopted in frequency control and metrology, with well-established standards at frequencies of 5 MHz and above. Their use as a resonant-mass strain antenna for high-frequency gravitational waves has been recently proposed (Goryachev and Tobar, 2014). The estimated power spectral density sensitivity at the resonant frequencies is of the order of . In this paper, after introducing the science opportunity and potential of gravitational wave detection with BAWs, we describe the two-stage BAUSCIA project plan to build a multimode antenna based on commercial BAWs, followed by an optimized array of custom BAWs. We show that commercially available BAWs already provide sensitivity comparable to current experiments around 10 MHz. Finally, we outline options for optimization of custom devices to improve sensitivity in an unexplored region, probe multiple frequencies between 0.1 and 10 MHz, and target specific signals, such as post-merger emission from neutron stars or emission from various dark matter candidates.Open AccessAn Array of Bulk Acoustic Wave Sensors as a High-Frequency Antenna for Gravitational Waves
In their simplest form, bulk acoustic wave (BAW) devices consist of a piezoelectric crystal between two electrodes that transduce the material’s vibrations into electrical signals. They are adopted in frequency control and metrology, with well-established standards at frequencies of 5 MHz and above. Their use as a resonant-mass strain antenna for high-frequency gravitational waves has been recently proposed (Goryachev and Tobar, 2014). The estimated power spectral density sensitivity at the resonant frequencies is of the order of . In this paper, after introducing the science opportunity and potential of gravitational wave detection with BAWs, we describe the two-stage BAUSCIA project plan to build a multimode antenna based on commercial BAWs, followed by an optimized array of custom BAWs. We show that commercially available BAWs already provide sensitivity comparable to current experiments around 10 MHz. Finally, we outline options for optimization of custom devices to improve sensitivity in an unexplored region, probe multiple frequencies between 0.1 and 10 MHz, and target specific signals, such as post-merger emission from neutron stars or emission from various dark matter candidates. - Open Access
- 25 April 2025
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 10 (3) , 035010
Qibosoq: an open-source framework for quantum circuit RFSoC programming
We present Qibosoq, an open-source server-side software package designed for radio frequency system on chip (RFSoC) for executing arbitrary pulse sequences and algorithms on self-hosted quantum processing units using only open-source software. Qibosoq connects the RFSoC firmware provided by Qick, a Quantum Instrumentation Control Kit, with Qibo, a quantum computing middleware framework that enables both experimental and gate-based applications. It simplifies the work of experimentalists and developers by managing client-server communication protocols, implementing tests, and validation procedures, thereby reducing the complexity of experimental setups. The client-side integration is achieved with dedicated drivers implemented in Qibolab, the specialized software module of Qibo for quantum hardware control. Therefore, this setup provides a seamless mechanism to deploy circuit-based algorithms on custom self-hosted quantum hardware platforms controlled by RFSoC electronics.
- 25 April 2025
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 10 (3) , 035010
Open AccessQibosoq: an open-source framework for quantum circuit RFSoC programming
We present Qibosoq, an open-source server-side software package designed for radio frequency system on chip (RFSoC) for executing arbitrary pulse sequences and algorithms on self-hosted quantum processing units using only open-source software. Qibosoq connects the RFSoC firmware provided by Qick, a Quantum Instrumentation Control Kit, with Qibo, a quantum computing middleware framework that enables both experimental and gate-based applications. It simplifies the work of experimentalists and developers by managing client-server communication protocols, implementing tests, and validation procedures, thereby reducing the complexity of experimental setups. The client-side integration is achieved with dedicated drivers implemented in Qibolab, the specialized software module of Qibo for quantum hardware control. Therefore, this setup provides a seamless mechanism to deploy circuit-based algorithms on custom self-hosted quantum hardware platforms controlled by RFSoC electronics.
- Open Access
- 13 June 2024
- Published by IOP Publishing in European Journal of Physics
- Vol. 45 (4) , 045802
A graduate laboratory experiment to set up a photon-counting detector using MKIDs
This paper presents a new laboratory activity aimed at developing knowledge and expertise in microwave applications at cryogenic temperatures. The experience focuses on the detection of infrared photons through microwave kinetic inductance detectors. The experimental setup, theoretical concepts, and activities involved are detailed, highlighting the skills and knowledge gained through the experience. This experiment is designed for graduate students in the field of quantum technologies.
- 13 June 2024
- Published by IOP Publishing in European Journal of Physics
- Vol. 45 (4) , 045802
Open AccessA graduate laboratory experiment to set up a photon-counting detector using MKIDs
This paper presents a new laboratory activity aimed at developing knowledge and expertise in microwave applications at cryogenic temperatures. The experience focuses on the detection of infrared photons through microwave kinetic inductance detectors. The experimental setup, theoretical concepts, and activities involved are detailed, highlighting the skills and knowledge gained through the experience. This experiment is designed for graduate students in the field of quantum technologies.
- Open Access
Sequence of penalties method to study excited states using VQE
We propose an extension of the Variational Quantum Eigensolver (VQE) that leads to more accurate energy estimations and can be used to study excited states. The method is based on the introduction of a sequence of increasing penalties in the cost function. This approach does not require circuit modifications and thus can be applied with no additional depth cost. Through numerical simulations, we show that we are able to produce variational states with desired physical properties, such as total spin and charge. We assess its performance both on classical simulators and on currently available quantum devices, calculating the potential energy curves of small molecular systems in different physical configurations. Finally, we compare our method to the original VQE and to another extension, obtaining a better agreement with exact simulations for both energy and targeted physical quantities.
Open AccessSequence of penalties method to study excited states using VQE
We propose an extension of the Variational Quantum Eigensolver (VQE) that leads to more accurate energy estimations and can be used to study excited states. The method is based on the introduction of a sequence of increasing penalties in the cost function. This approach does not require circuit modifications and thus can be applied with no additional depth cost. Through numerical simulations, we show that we are able to produce variational states with desired physical properties, such as total spin and charge. We assess its performance both on classical simulators and on currently available quantum devices, calculating the potential energy curves of small molecular systems in different physical configurations. Finally, we compare our method to the original VQE and to another extension, obtaining a better agreement with exact simulations for both energy and targeted physical quantities.