RMR. Chad McClennan

R. Chad McClennan

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


R. Chad McClennan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Wendie A. Berg

    Department of Radiology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA

    2 shared publications
  • Ajit Jairaj

    From the Department of Radiology, University of Pittsburgh School of Medicine, Magee-Womens Hospital, 300 Halket St, Pittsburgh, PA 15213 (W.A.B.); Departments of Gynecology (A.L.L.A., C.Y.G.) and Radiology (J.C.L.P.), Hospital Valentín Gómez Farias, Zapopan, Mexico; Koios Medical, New York, NY (A.J., R.C.M.); Department of Radiology, Keck School of Medicine of USC, Los Angeles, Calif (S.Y.C., L.H.L.); and Dr Susan Love Research Foundation, West Hollywood, Calif (M.T.S.d.L., S.L.).

    1 shared publication
  • Ajit Jairaj

    Koios Medical, Inc., Chicago, IL 60654, USA

    1 shared publication
  • Ana-Lilia López Aldrete

    From the Department of Radiology, University of Pittsburgh School of Medicine, Magee-Womens Hospital, 300 Halket St, Pittsburgh, PA 15213 (W.A.B.); Departments of Gynecology (A.L.L.A., C.Y.G.) and Radiology (J.C.L.P.), Hospital Valentín Gómez Farias, Zapopan, Mexico; Koios Medical, New York, NY (A.J., R.C.M.); Department of Radiology, Keck School of Medicine of USC, Los Angeles, Calif (S.Y.C., L.H.L.); and Dr Susan Love Research Foundation, West Hollywood, Calif (M.T.S.d.L., S.L.).

    1 shared publication
  • Andriy I. Bandos

    Department of Biostatistics, University of Pittsburgh School of Public Health, Pittsburgh, PA

    1 shared publication
  • Claudia Yolanda García

    From the Department of Radiology, University of Pittsburgh School of Medicine, Magee-Womens Hospital, 300 Halket St, Pittsburgh, PA 15213 (W.A.B.); Departments of Gynecology (A.L.L.A., C.Y.G.) and Radiology (J.C.L.P.), Hospital Valentín Gómez Farias, Zapopan, Mexico; Koios Medical, New York, NY (A.J., R.C.M.); Department of Radiology, Keck School of Medicine of USC, Los Angeles, Calif (S.Y.C., L.H.L.); and Dr Susan Love Research Foundation, West Hollywood, Calif (M.T.S.d.L., S.L.).

    1 shared publication

Latest Publications

  • Open Access

    Training AI to Improve Distinction of Triple-Negative Invasive Breast Cancer from Cysts and Fibroadenomas on Ultrasound

    by Wendie A. Berg, Andriy I. Bandos, Linda H. Larsen, Samantha L. Heller, Regina J. Hooley, Richard S. Ha, Maham Siddique, Jeremy M. Berg, Yuying Cao, R. Chad McClennan, et al.

    Background/Objectives: Circumscribed oval, hypoechoic masses are common on screening breast ultrasound (US), and the vast majority are benign. Triple-receptor negative invasive breast cancer (TNBC) can appear similar, resulting in both human and artificial intelligence (AI) interpretive errors. Purpose: We sought to improve AI performance in distinguishing common benign masses from TNBC through a retrospective model refinement and validation study. Materials and Methods: In an Institutional Review Board-approved HIPAA-compliant protocol, from five academic medical centers, orthogonal ultrasound images of 1771 breast masses 2 cm or smaller were acquired, consisting of cysts, complicated cysts, other benign, and malignancies. Cases were randomized, controlling for lesion class, site, and patient age, with 1446 (including 402, 27.8%, malignancies) used for training and 325 (including 95, 29.2% malignancies) for validation using Koios DS® (decision support, KDS) software version 2.0. A breast imaging radiologist from each center reviewed images and recorded BI-RADS features and assessment. Demographics, symptoms, and pathology or at least one-year follow-up was recorded. The KDS score was evaluated standalone and in combination with BI-RADS using logistic regression and ROC analysis with focus on specificity at sensitivity of 98%. Results: In training, KDS standalone performed comparably to BI-RADS, and significantly improved BI-RADS malignancy risk prediction (p < 0.001). The 98%–sensitivity threshold for combined KDS + BI-RADS was estimated and kept fixed during validation. In validation, KDS standalone performed similar to BI-RADS with AUC = 0.97 (CI: 0.95–0.98) versus 0.95 (p = 0.22), with sensitivity of 98% (93/95, CI: 95–100%) for both and specificity of 70.9% (163/230, CI: 65.0–76.7%) for KDS versus 63.9% for BI-RADS (147/230, p = 0.10). Combining KDS + BIRADS significantly improved overall performance (AUC 0.98, p < 0.001) and specificity (74.4%, 171/230, p < 0.001) while maintaining sensitivity at 98% (93/95). Conclusions: While KDS alone should not replace BI-RADS, when used in combination with BI-RADS, it can significantly improve specificity for highly accurate (98% sensitivity) triaging management of masses representative of those seen on screening US.

  • Toward AI-supported US Triage of Women with Palpable Breast Lumps in a Low-Resource Setting

    by Wendie A. Berg, Ana-Lilia López Aldrete, Ajit Jairaj, Juan Carlos Ledesma Parea, Claudia Yolanda García, R. Chad McClennan, Steven Yong Cen, Linda H. Larsen, M. Teresa Soler de Lara, Susan Love

    Background Most low- and middle-income countries lack access to organized breast cancer screening, and women with lumps may wait months for diagnostic assessment. Purpose To demonstrate that artificial intelligence (AI) software applied to breast US images obtained with low-cost portable equipment and by minimally trained observers could accurately classify palpable breast masses for triage in a low-resource setting. Materials and Methods This prospective multicenter study evaluated participants with at least one palpable mass who were enrolled in a hospital in Jalisco, Mexico, from December 2017 through May 2021. Orthogonal US images were obtained first with portable US with and without calipers of any findings at the site of lump and adjacent tissue. Then women were imaged with standard-of-care (SOC) US with Breast Imaging Reporting and Data System assessments by a radiologist. After exclusions, 758 masses in 300 women were analyzable by AI, with outputs of benign, probably benign, suspicious, and malignant. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were determined. Results The mean patient age ± SD was 50.0 years ± 12.5 (range, 18-92 years) and mean largest lesion diameter was 13 mm ± 8 (range, 2-54 mm). Of 758 masses, 360 (47.5%) were palpable and 56 (7.4%) malignant, including six ductal carcinoma in situ. AI correctly identified 47 or 48 of 49 women (96%-98%) with cancer with either portable US or SOC US images, with AUCs of 0.91 and 0.95, respectively. One circumscribed invasive ductal carcinoma was classified as probably benign with SOC US, ipsilateral to a spiculated invasive ductal carcinoma. Of 251 women with benign masses, 168 (67%) imaged with SOC US were classified as benign or probably benign by AI, as were 96 of 251 masses (38%, P < .001) with portable US. AI performance with images obtained by a radiologist was significantly better than with images obtained by a minimally trained observer. Conclusion AI applied to portable US images of breast masses can accurately identify malignancies. Moderate specificity, which could triage 38%-67% of women with benign masses without tertiary referral, should further improve with AI and observer training with portable US. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Slanetz in this issue.