JDJustine Demeuse

Justine Demeuse

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Justine Demeuse has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Caroline Le Goff

    Laboratory of Clinical Chemistry, CIRM, University of Liège, Belgium

    6 shared publications
  • Etienne Cavalier

    Laboratory of Clinical Chemistry, CIRM, University of Liège, Belgium

    6 shared publications
  • Stéphanie Peeters

    Department of Clinical Chemistry, University Hospital of Liège, Belgium

    6 shared publications
  • Elodie Grifnée

    Department of Clinical Chemistry, University Hospital of Liège, Belgium

    5 shared publications
  • Philippe Massonnet

    Department of Clinical Chemistry, University Hospital of Liège, Belgium

    5 shared publications
  • Thomas Dubrowski

    Department of Clinical Chemistry, University Hospital of Liège, Belgium

    5 shared publications

Latest Publications

  • Open Access

    Latest Advances in Structural Insights and Quantification Techniques for Type I Collagen Biomarkers: A path toward standardization?

    by Justine Demeuse, Alix Mackowiak, Elodie Grifnée, Philippe Massonnet, Loreen Huyghebaert, Thomas Dubrowski, Stéphanie Peeters, Caroline Le Goff, Etienne Cavalier

    With an aging population, the demand for sensitive and specific biomarkers to assess bone turnover has surged. Bone turnover involves 2 key processes: bone formation, during which Type I procollagen is cleaved into Type I collagen and subsequently mineralized into bone, and bone resorption, during which Type I collagen is demineralized and degraded into peptides by cathepsin K. To identify biomarkers that accurately reflect these processes, extensive efforts have been made to characterize the peptides generated during both formation and resorption. Over the years, numerous biomarkers have been discovered for various disorders. However, despite their clinical utility, many of these markers lack specificity. This is due to factors such as the degradation of trimers into monomers, the coexistence of multiple peptide species arising from the unpredictable cleavage of Type I collagen/procollagen by cathepsin K and metalloproteinases, and the lack of assay standardization. Standardization is further hindered by the incomplete characterization of many of these peptides. For accurate assay development, a gold-standard technique like LC-MS/MS is essential, requiring full peptide characterization during method development. This review aims to present recent advances in the characterization of Type I collagen-derived peptides, providing a foundation for improved biomarker standardization and application in clinical practice.


  • Open Access

    Development and validation of a highly-sensitive, quantitative LC-MS/MS assay to evaluate plasma oxytocin

    by E. Grifnée, A. Mackowiak, J. Demeuse, M. Schoumacher, L. Huyghebaert, W. Determe, T. Dubrowski, P. Massonnet, S. Peeters, G. Scantamburlo, et al.

    Oxytocin is a 9-amino acid peptide that serves as neuromodulator in the human central nervous system. This peptide is implicated in the regulation of diverse behaviors and plays a significant role in positive social interaction. Currently, oxytocin levels are measured using immunoassays. However, these methods have several limitations that can lead to false results and erroneous interpretation. Given the remarkably low endogenous level of oxytocin in human plasma (low ng/L levels), we developed and rigorously validated a novel and highly sensitive LC-MS/MS method for oxytocin quantification in plasma. Oxytocin was initially extracted using solid-phase extraction with an Oasis HLB 30 mg plate and then subjected to LC-MS/MS analysis. PBS-0.1 % BSA served as surrogate matrix for the preparation of validation samples and the calibration curve, ensuring no endogenous interference. The validation design followed the Clinical Laboratory Standards Institute guidelines. Precision, accuracy, and measurement uncertainty were determined using single-nested analysis of variance and e.noval software. A lower limit of quantification of 1 ng/L was achieved. The method was validated for oxytocin concentrations ranging from 1 ng/L to 75 ng/L, with precision (coefficient of variation) below 10 %, accuracy ranging from 94 % to 108 %, and measurement uncertainty below 15 %. In this work, we developed and validated a highly sensitive LC-MS/MS method for the quantification of oxytocin in plasma. Our novel methodology is well-suited for clinical applications.


  • Characterization of Trivalently Crosslinked C‐Terminal Telopeptide of Type I Collagen (CTX) Species in Human Plasma and Serum Using High‐Resolution Mass Spectrometry

    by Justine Demeuse, William Determe, Elodie Grifnée, Philippe Massonnet, Matthieu Schoumacher, Loreen Huyghebeart, Thomas Dubrowski, Stéphanie Peeters, Caroline Le Goff, Etienne Cavalier

    With an aging population, the increased interest in the monitoring of skeletal diseases such as osteoporosis led to significant progress in the discovery and measurement of bone turnover biomarkers since the 2000s. Multiple markers derived from type I collagen, such as CTX, NTX, PINP, and ICTP, have been developed. Extensive efforts have been devoted to characterizing these molecules; however, their complex crosslinked structures have posed significant analytical challenges, and to date, these biomarkers remain poorly characterized. Previous attempts at characterization involved gel‐based separation methods and MALDI‐TOF analysis on collagen peptides directly extracted from bone. However, using bone powder, which is rich in collagen, does not represent the true structure of the peptides in the biofluids as it was cleaved. In this study, our goal was to characterize plasma and serum CTX for subsequent LC‐MS/MS method development. We extracted and characterized type I collagen peptides directly from human plasma and serum using a proteomics workflow that integrates preparative LC, affinity chromatography, and HR‐MS. Subsequently, we successfully identified numerous CTX species, providing valuable insights into the characterization of these crucial biomarkers.


  • Open Access

    Characterization of trivalently crosslinked C-terminal telopeptide of type I collagen (CTX) species in human plasma and serum using high resolution mass spectrometry

    by Justine Demeuse, William Determe, Elodie Grifnée, Philippe Massonnet, Matthieu Schoumacher, Loreen Huyghebaert, Thomas Dubrowski, Stéphanie Peeters, Caroline Le Goff, Etienne Cavalier

    With an aging population, there has been significant progress in the discovery and measurement of bone turnover biomarkers since the 2000s, especially for monitoring skeletal diseases like osteoporosis. Multiple markers derived from type I collagen, such as CTX, NTX, PINP, and ICTP, have been developed. Extensive efforts have been devoted to characterizing these molecules; however, their complex crosslinked structures have posed significant analytical challenges, and to date, these biomarkers remain poorly characterized. Previous attempts at characterization involved gel-based separation methods and MALDI-TOF analysis on collagen peptides directly extracted from bone. However, using bone powder, while rich in collagen, does not represent the true structure of the peptides in the biofluids. In this study, our goal was to characterize plasma and serum CTX for subsequent LC-MS/MS method development. We extracted and characterized type I collagen peptides directly from human plasma and serum using a proteomics workflow that integrates preparative liquid chromatography, affinity chromatography, and high-resolution mass spectrometry. Subsequently, we successfully identified numerous CTX species, providing valuable insights into the characterization of these crucial biomarkers.

  • Development and validation of an LC-MS/MS method for the simultaneous quantitation of angiotensin (1–7), (1–8), (1–9) and (1–10) in human plasma

    by Justine Demeuse, Loreen Huyghebaert, William Determe, Matthieu Schoumacher, Elodie Grifnée, Philippe Massonnet, Thomas Dubrowski, Marwa Rechchad, Jordi Farre Segura, Stéphanie Peeters, et al.


  • Innovative workflow for the identification of cathepsin K cleavage sites in type I collagen

    by Justine Demeuse, Philippe Massonnet, Matthieu Schoumacher, Elodie Grifnée, Loreen Huyghebaert, Thomas Dubrowski, Stéphanie Peeters, Caroline Le Goff, Etienne Cavalier


  • Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva

    by Justine J. Demeuse, Chiara Calaprice, Loreen C. Huyghebaert, Marwa Rechchad, Stéphanie Peeters, Etienne Cavalier, Caroline Le Goff

    A growing body of literature describes the potential effects of circadian disruption on human health. Indeed, psychiatric diseases, metabolic syndrome, and cancers may be linked to disturbance of the circadian rhythm. Currently, the best practice to assess circadian rhythm is the measurement of melatonin levels. Our goal was thus to develop and validate a highly sensitive LC-MS/MS method to follow salivary melatonin levels throughout the day and night. Our method reached a lower limit of the measuring interval (LLMI) of 0.8 pg/mL. To our knowledge, it is the most sensitive method allowing quantitation of melatonin in saliva. Saliva, obtained from passive drooling or salivette, was extracted by an efficient and quick liquid-liquid extraction with no further needed. The method was validated to the European Medicines Agency (EMA) guidelines and provided excellent results regarding accuracy, precision, linearity, selectivity, and specificity. Comparison between radioimmunoassay and our method was performed and showed differences at low levels, most likely due to cross-reactivity with other indols. To assess daytime melatonin levels in humans, salivary melatonin levels of ten volunteers were monitored throughout the day and showed lower daytime levels than reported in previous studies.