MLMayke Maria Christina Josephina van Leunen

Mayke Maria Christina Josephina van Leunen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mayke Maria Christina Josephina van Leunen has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Real-World Impact of Remote Patient Management on Care Consumption and Care Time in Heart Failure: Retrospective Cohort Study

    by Wessel William Nieuwenhuys, Mayke Maria Christina Josephina van Leunen, Jeroen Albert Adrianus van de Pol, Frederique Jantine Hafkamp, Rudolph Ferdinand Spee, René Anton Tio, Mathias Funk, Hareld Marijn Clemens Kemps

    Background: Remote patient management (RPM) is a strategy to track daily health data in patients with heart failure (HF) to enable early detection and treatment of decompensation to prevent hospital readmissions. The implementation of RPM alters standard care and redistributes provider responsibilities. Although randomized controlled trials demonstrate positive clinical outcomes, the impact of implementing RPM on patients’ health care usage, as well as the care time and workload of health care providers in a real-world setting, remains unclear. Objective: The objective of this retrospective study is to explore the effects of implementing RPM for HF on patients’ cardiac care consumption and caregiver workload within a regional care network through the use of real-world data. Methods: Two hospitals in the same regional care network with aligned care pathways for usual care (UC) were compared: one with RPM (hospital 1) and one without (hospital 2). Between June 2021 and July 2022, patients with HF were included from a clinical registry with a 1-year follow-up. Cardiac health care consumption was quantified by the number and duration of consultations (in-person, phone, and RPM) with nurse practitioners specialized in HF care and cardiologists. HF-related readmissions were also collected. Three groups were analyzed: hospital 1 RPM, hospital 1 UC, and hospital 2 UC. Results: A total of 131 patients were included (hospital 1 RPM: 34, hospital 1 UC: 64, hospital 2 UC: 33). Consultation frequency and duration were significantly higher in the hospital 1 RPM cohort compared to the hospital 1 UC and the hospital 2 UC cohorts (frequency: mean 18.5, SD 9.3 vs mean 9.3, SD 6.0 and mean 11.6, SD 6.3; P <.001; duration: mean 233.2, SD 95.2 min vs mean 121.2, SD 47.9 min and mean 113.0, SD 66.0 min; P <.001), mainly due to increased number of consultations of nurse practitioners specialized in HF care (hospital 1 RPM: mean 15.3, SD 8.4 vs hospital 1 UC: mean 5.3, SD 2.4 and hospital 2 UC: mean 8.6, SD 6.1; P <.001). No significant differences were observed regarding cardiologist care time ( P =.27), cardiologist number of consultations ( P =.43), or HF-related readmissions ( P =.47). Conclusions: In this real-world study, the implementation of RPM for patients with HF was associated with a higher nursing workload, with no observed differences in cardiologists’ consultations or patient outcomes. These findings highlight the need for optimization at organizational and technological levels and underline the importance of real-world evaluation of the implementation of innovations.

  • Open Access

    Real-world Evaluation of the Impact of Remote Patient Management in Heart Failure on Care Consumption and Care Time (Preprint)

    by Wessel William Nieuwenhuys, Mayke Maria Christina Josephina van Leunen, Jeroen Albert Adrianus van de Pol, Frederique Jantine Hafkamp, Rudolph Ferdinand Spee, René Anton Tio, Mathias Funk, Hareld Marijn Clemens Kemps

    BACKGROUND Remote Patient Management (RPM) is a strategy to track daily health data in patients with heart failure (HF) to enable early detection and treatment of decompensation to prevent hospital readmissions. Implementation of RPM alters standard care and redistributes provider responsibilities. Although randomized controlled trials demonstrate positive clinical outcomes, the impact of implementing remote patient monitoring on patients’ healthcare utilization, as well as the care time and workload of healthcare providers in a real-world setting, remains unclear. OBJECTIVE The goal of this retrospective study is to evaluate the effects of implementing remote patient monitoring for heart failure on patient care consumption and caregiver workload within a regional care network. METHODS Two hospitals in the same regional care network with aligned care pathways for usual care were compared: one with remote patient monitoring (Hospital 1) and one without (Hospital 2). Between June 2021 and July 2022, HF patients were included from a clinical registry with one-year follow-up. Cardiac healthcare consumption was quantified by the number and duration of consultations (in-person, phone, RPM) with HF-nurses and cardiologists. HF-related readmissions were also collected. Three groups were analyzed: Hospital 1 Usual Care (UC)+RPM, Hospital 1 UC, and Hospital 2 UC. RESULTS 131 patients were included (Hospital 1 UC+RPM: 34, Hospital 1 UC: 64, Hospital 2 UC: 33). Consultation frequency and duration were significantly higher in the UC+RPM group (p < 0.001), mainly due to increased HF-nurse consultations (p < 0.001). No significant differences were observed regarding cardiologist care time, cardiologist number of consultations or HF-related readmissions. CONCLUSIONS In this real-world study, implementation of RPM in patients with HF increased nurses' workload without benefit on cardiologists’ consultations or patient outcomes. These findings highlight the need for optimization at organizational and technological levels and underline the importance of real-world evaluation of implementations of innovations.

  • Open Access

    Noninvasive Multiparameter Monitoring for the Detection of Decompensated Heart Failure: Exploratory Study

    by Cyrille Herkert, Mayke van Leunen, Ignace Luc Johan De Lathauwer, Valerie Albertina Antonetta van Es, Jialu Tang, Aaqib Saeed, Rudolph Ferdinand Spee, Yuan Lu, Hareld Marijn Clemens Kemps

    Background: Remote patient monitoring strategies in patients with heart failure (HF) are often based on manual readings and interpretation of various parameters by health care professionals. Automated multiparameter predictive models (MPMs) have the potential to improve early recognition of decompensated HF and to reduce the workload for both health care professionals and patients. To reduce costs and facilitate large-scale implementation, these models should preferably be based on noninvasive measurements, with user-friendly devices. Objective: This exploratory study aimed to evaluate whether an MPM, using various parameters from a wrist-worn device supplied with a photoplethysmography sensor and a triaxial accelerometer, contributes to the detection of decompensated HF and death in patients with unstable HF. Methods: Patients who were admitted to the hospital with acute decompensated HF, regardless of etiology or left ventricular ejection fraction, were instructed to wear a research-grade wrist-worn device from the moment of discharge. The device measured heart rate (HR), interbeat intervals (IBIs), respiration rate (RR), activity counts (AC), energy expenditure (EE), and sleep. Participants were instructed to wear the device 24 hours a day for 3 consecutive months. We evaluated 7 classifiers under four strategies for handling extreme class imbalance; the best model was then tested via leave-one-subject-out cross-validation on untouched data. The combined end point of interest was hospital readmission due to decompensated HF, decompensated HF treated at the outpatient clinic by increasing the loop diuretic dose, or death due to HF. Results: A total of 17 patients participated in the study (median age 77, IQR 70‐84 y; n=9, 53% male). During follow-up, the device-wearing compliance was 78% (55%‐81%). The activity-related parameters (EE and AC) performed best with respect to data quality: 72% and 79% of the data were of high quality, respectively. Concerning HR, 46% of the data were of high quality, whereas only 29% of the IBI and 14% of the RR data were of high quality. Sleep data were lacking 99% of the time during follow-up, resulting in exclusion from training the classifier. The most optimal model for the detection of the combined end point of HF deterioration showed a specificity of 97.2% and a sensitivity of 5.3% in the 2 weeks prior to an event (area under the curve=0.59) after leave-one-subject-out cross-validation analysis. Conclusions: An MPM using a noninvasive wrist-worn device, measuring HR, IBI, RR, AC, and EE, showed high specificity but low sensitivity for the prediction of decompensated HF and HF-related mortality. Low sensitivity likely reflects the extreme class imbalance and sequences with low data quality (especially HR, RR, and sleep), resulting in exclusion from training the MPM in our older, real-world HF cohort. Future studies should improve data fidelity and enroll larger cohorts to address class imbalance and enhance predictive performance.


  • Open Access

    Validity of self-assessment tools for cardiovascular risk behaviors: A systematic review

    by Wilhelmina F. Goevaerts, Joyce M. Heutinck, Mayke M.C.J. Van Leunen, Wessel W. Nieuwenhuys, Lonneke A. Fruytier, Cyrille Herkert, Jos J. Kraal, Ilse A.G. Rongen, Willem J. Kop, Yuan Lu, et al.

  • Open Access

    Analysis of a Medically Certified, Wrist-Worn Sensor for the Assessment of Heart Rate and Energy Expenditure During Daily Activities in Patients With Chronic Heart Failure or Coronary Artery Disease and Recreational Athletes: Validation Study

    by Ignace L J De Lathauwer, Valerie A A van Es, Mayke M C J van Leunen, Steven Onkelinx, Rutger W M Brouwers, Danny A J P van de Sande, Mathias Funk, Hareld M C Kemps

    Background: Exercise capacity and lifestyle have proven to be important prognostic factors for cardiovascular patients. Both can be ameliorated through different preventive interventions. Cardiac rehabilitation and remote patient monitoring have been proven to reduce cardiac events and cardiovascular mortality. One of the most important goals of cardiac rehabilitation and remote patient monitoring is improving physical fitness and monitoring of cardiovascular parameters, which could predict cardiac deterioration. In order to monitor cardiac patients successfully, reliable and nonobtrusive devices to assess physical activity and cardiovascular parameters need to be available. Objective: This validation study aims to determine the accuracy of the Philips Health Band (PHB), a noninvasive, wrist-worn, medically certified device, for the assessment of heart rate (HR) and energy expenditure (EE) in patients with chronic cardiovascular diseases and recreational athletes (RAs). Methods: The assessment of HR and EE by the PHB was compared with indirect calorimetry (Oxycon Mobile [OM; CareFusion GmbH]) during an activity protocol consisting of daily activities. Three groups were assessed: patients with heart failure with reduced ejection fraction (HFrEF), patients with stable coronary artery disease (CAD) with preserved left ventricular ejection fraction, and RAs. Results: A total of 57 patients were included: 19 with CAD, 19 with HFrEF, and 19 RAs. HR assessment in the HFrEF and CAD groups was significantly underestimated over the entire protocol by the PHB as compared to the OM, with poor and fair reliability, respectively. No significant difference in HR was found between the PHB and OM over the entire protocol for the RA group, with good reliability (HFrEF: mean difference 3.0; P <.001; intraclass correlation coefficient [ICC] 0.36; CAD: mean difference 2.7; P <.001; ICC 0.55; RA: mean difference 0.8; ICC 0.60). Assessment of EE showed an underestimation over the entire protocol for the RA and CAD group, with poor and fair reliability, respectively. The HFrEF group showed no significant difference in EE assessment over the entire protocol, with poor reliability (HFrEF: mean difference 0.09; ICC 0.32; CAD: mean difference 0.29; P <.001; ICC 0.46; RA: mean difference 0.79; P <.001; ICC 0.26). The responsiveness to detect within-patient changes in activity intensity of the PHB was moderate for the HFrEF and CAD groups and acceptable for the RA group. Conclusions: HR and EE assessment of a medically certified noninvasive sensor using a photoplethysmogram and accelerometer showed poor accuracy and moderate responsiveness during an activity protocol reflecting daily living activities in patients with stable CAD and chronic HFrEF. Accuracy of HR in RAs was good and the responsiveness for both HR and EE was acceptable. This research confirms previous research and stresses the need for better patient-specific algorithms in noninvasive sensors, taking cardiovascular pathology and medication usage into account, for assessing HR and EE prior to their implemention in patient care.


  • Open Access

    Predicting Acute Decompensated Heart Failure Using Circadian Markers From Heart Rate Time Series

    by Valerie A. A. van Es, Mayke M. C. J. van Leunen, Ignace L. J. de Lathauwer, Cindy C. A. G. Verstappen, René A. Tio, Ruud F. Spee, Lu Yuan, Monica Betta, Giacomo Handjaras, Hareld M. C. Kemps

    Aims: Hospital admissions for acute decompensated heart failure (ADHF) are linked to high readmission rates, emphasizing the need for early intervention. Dysregulation of the circadian rhythm that regulates key physiological processes, such as heart rate (HR), blood pressure and sleep–wake cycles, may precede weight gain and clinical symptoms of worsening heart failure (HF) by weeks, providing a window for timely intervention. This study aims to develop a predictive algorithm for early and accurate ADHF detection. Methods and results: Sixty-five patients discharged after ADHF hospitalization monitored HR with a wrist-worn device for 6 months after reaching stable HF. Circadian parameters (mesor, amplitude and acrophase) were extracted via cosinor analysis and used to train a long short-term memory neural network. The algorithm analysed 21-day periods before an HF event, defined as unplanned outpatient visits for congestion episode, increased diuretics, ADHF hospitalization or sudden cardiac death. Circadian changes appeared in the 21 days preceding HF events, with elevated mesor (70.6 vs. 73.6 b.p.m.; P < 0.001), reduced amplitude (8.3 vs. 4.9 b.p.m.; P = 0.046) and acrophase shifts (11.3 vs. 12.2 h; P = 0.706). The classification algorithm showed 74% sensitivity, 73% specificity and a 74% AUC (P < 0.001). Amplitude was the strongest predictor, contributing 62% to the algorithm's feature importance. Conclusions: Circadian metrics from a wrist-worn device showed progressive alterations over the 3 weeks preceding ADHF, offering potential early detection of HF decompensation with moderate prediction performance. Future research should refine these metrics and results in larger, diverse populations, using various sensor types and explore early interventions.


  • Open Access

    Association of Technology-Related Skills and Self-Efficacy With Willingness to Participate in Heart Failure Telemonitoring: Cross-Sectional Observational Study

    by Sharon Cuppen, Mayke van Leunen, Tamara Henken, Mayra Goevaerts, Martijn Scherrenberg, Maarten Falter, Paul Dendale, Hareld Kemps, Willem J Kop

    Background: The adoption of telemonitoring in patients with heart failure (HF) is influenced by technology-related skills and self-efficacy, as well as psychological, clinical, and demographic factors. However, the relative importance of these factors with regard to willingness to use telemonitoring is insufficiently understood. Objectives: This cross-sectional observational study examines the extent to which technology-related skills and self-efficacy are related to willingness to participate in telemonitoring in patients with HF. Methods: Patients completed questionnaires during hospitalization. Associations of technological skills and self-efficacy with willingness to participate in telemonitoring (dichotomous and continuous scale) were examined using regression models. Mediation-moderation analyses were used to investigate the role of self-efficacy in the association of technological skills with willingness to participate. Results: This study recruited 61 patients admitted for decompensated HF (mean age 79.9, SD 9.5 years; 24 women). Higher levels of technological skills were associated with higher willingness to participate in telemonitoring (odds ratio [OR] 1.073 per scale unit, 95% CI 1.031-1.117). Technological self-efficacy and learnability were also related to willingness to participate (OR 1.141, 95% CI 1.039-1.252; OR 1.029, 95% CI 1.006-1.052) but did not mediate the association of technological skills with willingness to participate in telemonitoring. Psychological factors (anxiety, depressive symptoms, and perceived social support), age, and cognitive and physical functioning did not moderate the association of technological skills with willingness to participate in telemonitoring. Conclusions: Technological skills, self-efficacy, and learnability are interrelated factors that need to be considered in patients with HF who are eligible for telemonitoring. Future intervention studies that target these factors could increase patients’ willingness and competence in using telemonitoring after admission for HF.


  • Open Access

    Validation of a medically certified, wrist-worn sensor for the assessment of heart rate and energy expenditure during daily activities in patients with chronic heart failure, coronary artery disease and recreational athletes (Preprint)

    by Ignace L. J. De Lathauwer, Valerie A.A. van Es, Mayke M.C.J. van Leunen, Steven Onkelinx, Rutger W.M. Brouwers, Danny A.J.P. van de Sande, Mathias Funk, Hareld M.C. Kemps

    BACKGROUND Exercise capacity and lifestyle have proven to be important prognostic factors for cardiovascular patients. Both can be ameliorated through different preventive interventions. Cardiac rehabilitation (CR) and remote patient monitoring (RPM) have proven to reduce cardiac events and cardiovascular mortality. One of the most important goals of CR and RPM is improving physical fitness and monitoring of cardiovascular parameters which could predict cardiac deterioration. In order to monitor cardiac patients successfully, reliable and non-obtrusive devices to assess physical activity (PA) and cardiovascular parameters need to be available. OBJECTIVE The aim of this validation study was to determine the accuracy of the Philips health band (PHB), a non-invasive, wrist-worn, medically certified device, for the assessment of heart rate (HR) and energy expenditure (EE) in chronic cardiovascular patients and recreational athletes. METHODS Assessment of HR and EE by the PHB was compared with indirect calorimetry (Oxycon Mobile (OM)) during an activity protocol, consisting of daily activities. Three groups were assessed: patients with heart failure with reduced ejection fraction (HFrEF), patients with stable coronary artery disease (CAD) with preserved left ventricular ejection fraction (LVEF) and recreational athletes (RA). RESULTS A total of 57 patients were included: 19 with CAD, 19 with HFrEF and 19 recreational athletes. HR assessment in the HFrEF and CAD group was significantly underestimated over the entire protocol by the PHB as compared to the OM, with poor and fair reliability respectively. No significant difference in HR was found between the PHB and OM over the entire protocol for the RA group, with a good reliability (HFrEF: mean difference 2.97, p<0.001, ICC 0.36; CAD: mean difference 2.65, p<0.001, ICC 0.55; RA: mean difference 0.78, ICC 0.60). Assessment of EE showed an underestimation over the entire protocol for the RA and CAD group, with poor and fair reliability respectively. The HFrEF group showed no significant difference in EE assessment over the entire protocol, with a poor reliability. (HFrEF: mean difference 0.09, ICC 0.32; CAD: mean difference 0.29, p<0.001, ICC 0.46; RA: mean difference 0.79, p<0.001, ICC 0.26). The responsiveness, to detect within patient changes in activity intensity, of the PHB was moderate for the HFrEF and CAD group, and acceptable for the RA group. CONCLUSIONS HR and EE assessment of a medically certified non-invasive sensor, using PPG and accelerometer, showed poor accuracy and moderate responsiveness during an activity protocol reflecting daily living activities in patients with stable CAD and chronic HFrEF. Accuracy of HR in recreational athletes was good and responsiveness for both HR and EE acceptable. This research confirms prior research and stresses the need for better patient specific algorithms in non-invasive sensors, taking cardiovascular pathology and medication usage into account, for assessing HR and EE, before implementing them in patient care.


  • Open Access

    Evaluation of two self-reported questionnaires for assessment of peak exercise capacity in patients with chronic heart failure

    by Mayke M C J van Leunen, Martijn van Hooff, Renske Meijer, Nikki H M Wijnands, Richard A J Post, Ruud F Spee, Yuan Lu, Goof Schep, Hareld M C Kemps

    Peak oxygen uptake (VO2peak), assessed by maximal cardiopulmonary exercise testing (CPET), is a powerful predictor of cardiovascular morbidity and mortality. In clinical practice, the use of CPET is often not feasible or desirable in (older) frail patients.1 In the last decades, several exercise and non-exercise-based algorithms to predict VO2peak were evaluated.2 These prediction models are less accurate than CPET, yet easily accessible and applicable.3 Overall, reviews showed low to moderate correlation for non-exercise algorithms [r = 0.66–0.86, and SEE (standard error of estimate) 3.82–7.31 mL/kg/min] and submaximal exercise-based algorithms (r = 0.21–0.70, and SEE 2.50–4.43) in a healthy population.2,4,5 However, elderly patients with chronic diseases were typically excluded in the development and validation of these models.6 The current study aimed to investigate the accuracy of two self-reported questionnaires to predict VO2peak in chronic heart failure (CHF) patients; the FitMáx©-questionnaire (hereafter FitMáx) (see Supplementary material online for the full English version ),7 and The Fitness Calculator (HFC),8 the latter is currently advised in healthy men and women by the American Heart Association.2


  • Open Access

    Telerehabilitation in patients with recent hospitalisation due to acute decompensated heart failure: protocol for the Tele-ADHF randomised controlled trial

    by Mayke M. C. J. van Leunen, Ignace L. J. de Lathauwer, Cindy C. A. G. Verstappen, Dianne M. G. Visser-Stevelink, Rutger W. M. Brouwers, Cyrille Herkert, René A. Tio, Ruud F. Spee, Yuan Lu, Hareld M. C. Kemps

    Background: Cardiac rehabilitation in patients with chronic heart failure (CHF) has favourable effects on exercise capacity, the risk at hospital (re-)admission and quality of life. Although cardiac rehabilitation is generally recommended it is still under-utilised in daily clinical practice, particularly in frail elderly patients after hospital admission, mainly due to low referral and patient-related barriers. Cardiac telerehabilitation (CTR) has the potential to partially solve these barriers. The purpose of this study is to evaluate the effects of CTR as compared to standard remote care after hospital admission on physical functional capacity in CHF patients. Methods: In this randomised controlled trial, 64 CHF patients will be recruited during hospitalisation for acute decompensated heart failure, and randomised to CTR combined with remote patient management (RPM) or RPM alone (1:1). All participants will start with RPM after hospital discharge for early detection of deterioration, and will be up titrated to optimal medical therapy before being randomised. CTR will start after randomisation and consists of an 18-week multidisciplinary programme with exercise training by physical and occupational therapists, supported by a (remote) technology-assisted dietary intervention and mental health guiding by a physiologist. The training programme consists of three centre-based and two home-based video exercise training sessions followed by weekly video coaching. The mental health and dietary programme are executed using individual and group video sessions. A wrist-worn device enables remote coaching by the physical therapist. The web application is used for promoting self-management by the following modules: 1) goal setting, 2) progress tracking, 3) education, and 4) video and chat communication. The primary outcome measure is physical functional capacity evaluated by the Short Physical Performance Battery (SPPB) score. Secondary outcome measures include frailty scoring, recovery after submaximal exercise, subjective health status, compliance and acceptance to the rehabilitation programme, and readmission rate. Discussion: The Tele-ADHF trial is the first prospective randomised controlled trial designed for evaluating the effects of a comprehensive combined RPM and CTR programme in recently hospitalised CHF patients. We hypothesize that this intervention has superior effects on physical functional capacity than RPM alone. Trial registration: Netherlands Trial Registry (NTR) NL9619, registered 21 July 2021.