Asad Qadir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Asad Qadir has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Alan Nugent
Department of Pediatrics, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
2 shared publications - Paul Tannous
Department of Pediatrics, Division of Cardiology, Ann and Robert H. Lurie Children's Hospital, Chicago, IL, USA
2 shared publications - Amy E. Cassedy
Division of Biostatistics and Epidemiology, Department of Pediatrics, Cincinnati Children's Hospital Medical Center, Cincinnati, OH
1 shared publication Bradley S. Marino
Department of Pediatric Cardiology, Cleveland Clinic Children's, Cleveland, OH
1 shared publication- Conor O'HAlloran
Royal (Dick) School of Veterinary Studies University of Edinburgh, Easter Bush Veterinary Campus Edinburgh UK
1 shared publication - Conor P. O'HAlloran
Ann & Robert H. Lurie Children's Hospital of Chicago Chicago Illinois USA
1 shared publication
Latest Publications
- Open Access
- 23 August 2024
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 3 (10) , 102280
Complete Obstruction of Superior Mustard Baffle: Electrosurgical Transcatheter Recanalization—First-in-Human Case Report
- 23 August 2024
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 3 (10) , 102280
Open AccessComplete Obstruction of Superior Mustard Baffle: Electrosurgical Transcatheter Recanalization—First-in-Human Case Report
- 16 April 2021
- Published by Springer Nature in Pediatric Cardiology
- Vol. 42 (5) , 1209-1215
Deployed Dimensions of the GORE® CARDIOFORM ASD Occluder as Function of Defect Size
The GORE® CARDIOFORM ASD occluder (ASDO) is approved for closure of ASDs up to 35 mm diameter. With an adaptable central waist, each device size is suitable over a range of defect diameters. Understanding deployed dimensions across various defect sizes will assist operators. Therefore, this study investigates the deployed dimensions of the ASDO as a function of defect size. A 2-mm-thick ASD model with circular defects ranging from 5 to 35 mm was 3D printed. Diameter, width, and left–right disc diameter were measured by fluoroscopy after ASDO devices were deployed in applicable defects. Linear regression evaluated relationships between device size, defect size, and deployed dimensions. Six ASDOs of each size (27, 32, 37, 44, and 48 mm) were deployed in all applicable defects. There was significant ASDO size–defect size interaction in determining deployed ASDO diameter. Diameter was positively associated with defect size for 48-mm (B = 0.13, p < 0.001) and 44-mm (B = 0.11, p < 0.001) ASDOs, while no association was seen for 27-mm, 32-mm, or 37-mm ASDOs. No such interaction existed for deployed width or left–right disc difference. Controlling for ASDO size, width (B = − 0.12, p < 0.001) and left–right disc difference (B = − 0.06, p < 0.001) were negatively associated with defect size. In smaller defects, the 44-mm and 48-mm ASDOs display progressive diameter foreshortening, and all devices display progressive increase in width and left–right disc asymmetry. Anticipating the degree of diameter foreshortening may be critical when attempting closure of fenestrated lesions and/or in patients with limited total atrial septal length.
- 16 April 2021
- Published by Springer Nature in Pediatric Cardiology
- Vol. 42 (5) , 1209-1215
Deployed Dimensions of the GORE® CARDIOFORM ASD Occluder as Function of Defect Size
The GORE® CARDIOFORM ASD occluder (ASDO) is approved for closure of ASDs up to 35 mm diameter. With an adaptable central waist, each device size is suitable over a range of defect diameters. Understanding deployed dimensions across various defect sizes will assist operators. Therefore, this study investigates the deployed dimensions of the ASDO as a function of defect size. A 2-mm-thick ASD model with circular defects ranging from 5 to 35 mm was 3D printed. Diameter, width, and left–right disc diameter were measured by fluoroscopy after ASDO devices were deployed in applicable defects. Linear regression evaluated relationships between device size, defect size, and deployed dimensions. Six ASDOs of each size (27, 32, 37, 44, and 48 mm) were deployed in all applicable defects. There was significant ASDO size–defect size interaction in determining deployed ASDO diameter. Diameter was positively associated with defect size for 48-mm (B = 0.13, p < 0.001) and 44-mm (B = 0.11, p < 0.001) ASDOs, while no association was seen for 27-mm, 32-mm, or 37-mm ASDOs. No such interaction existed for deployed width or left–right disc difference. Controlling for ASDO size, width (B = − 0.12, p < 0.001) and left–right disc difference (B = − 0.06, p < 0.001) were negatively associated with defect size. In smaller defects, the 44-mm and 48-mm ASDOs display progressive diameter foreshortening, and all devices display progressive increase in width and left–right disc asymmetry. Anticipating the degree of diameter foreshortening may be critical when attempting closure of fenestrated lesions and/or in patients with limited total atrial septal length.