Ling Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ling Zhang has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Shaobai Wang
School of Exercise and Health, Shanghai University of Sport, Shanghai 200438, China
5 shared publications Junjie Xu
Department of Sports Medicine, Shanghai Sixth People’s Hospital, Shanghai Jiao Tong University, Shanghai, China
3 shared publicationsCong Wang
School of Biomedical Engineering and Med‐X Research Institute Shanghai Jiao Tong University Shanghai China
2 shared publicationsJinzhong Zhao
Department of Sports Medicine Shanghai Jiao Tong University Affiliated Sixth People's Hospital Shanghai China
2 shared publications- Liming Cheng
Division of Spine, Department of Orthopedics, Tongji Hospital Affiliated to Tongji University, School of Medicine, Tongji University, Shanghai, China
2 shared publications Shuai Fan
Department of Rehabilitation Medicine, Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 19 December 2025
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (4) , 9770-9778
Safety and accuracy of robot-assisted pedicle screw fixation: a randomized controlled trial
Background: Accurate pedicle screw placement is essential yet challenging in spinal surgery. This trial evaluated whether a robotic system with biplane fluoroscopic positioning could improve accuracy, efficiency, and safety compared to conventional fluoroscopy-guided techniques. Materials and methods: This multicenter, parallel-group, randomized trial was conducted at three hospitals. A total of 70 patients requiring pedicle screw fixation were randomly assigned (1:1) to either the robot-assisted group (RG) or the conventional fluoroscopy-guided group (CG). In the RG, a robotic navigation system assisted in planning and localizing the guide pin entry point and trajectory based on a biplane algorithm that integrated anteroposterior and lateral fluoroscopic images with optical tracking data to achieve real-time spatial registration. This biplane positioning technique was derived from the principles of the Dual Fluoroscopic Imaging System (DFIS). In the CG, guide pin placement was performed under conventional fluoroscopic guidance. The primary outcome was the deviation of guide pin placement. Secondary outcomes included the cumulative number of exposures, total radiation dose, operative time, average time to establish a single channel, and number of channel adjustments. Results: The mean deviation of guide pin placement in the RG was significantly smaller than that in the CG (0.86 ± 0.57 mm vs. 2.55 ± 1.88 mm, P < 0.001). The RG also had significantly fewer cumulative number of exposures (4.56 ± 1.70 vs. 13.38 ± 19.01, P = 0.003) and lower total radiation doses (7.35 ± 3.33 μSv vs. 30.28 ± 97.41 μSv, P = 0.024). The operative time was similar between the groups (245.03 ± 67.06 min vs. 215.18 ± 83.08 min, P = 0.083). The number of channel adjustments was significantly lower in the RG (0.06 ± 0.29 vs. 0.28 ± 0.90 , P = 0.014). There were no significant differences in the incidence of adverse events between the two groups. Conclusions: The robotic system with biplane fluoroscopic positioning improved guide pin accuracy and reduced radiation exposure, indicating its potential to enhance precision and safety in spinal surgery.
- 19 December 2025
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (4) , 9770-9778
Open AccessSafety and accuracy of robot-assisted pedicle screw fixation: a randomized controlled trial
Background: Accurate pedicle screw placement is essential yet challenging in spinal surgery. This trial evaluated whether a robotic system with biplane fluoroscopic positioning could improve accuracy, efficiency, and safety compared to conventional fluoroscopy-guided techniques. Materials and methods: This multicenter, parallel-group, randomized trial was conducted at three hospitals. A total of 70 patients requiring pedicle screw fixation were randomly assigned (1:1) to either the robot-assisted group (RG) or the conventional fluoroscopy-guided group (CG). In the RG, a robotic navigation system assisted in planning and localizing the guide pin entry point and trajectory based on a biplane algorithm that integrated anteroposterior and lateral fluoroscopic images with optical tracking data to achieve real-time spatial registration. This biplane positioning technique was derived from the principles of the Dual Fluoroscopic Imaging System (DFIS). In the CG, guide pin placement was performed under conventional fluoroscopic guidance. The primary outcome was the deviation of guide pin placement. Secondary outcomes included the cumulative number of exposures, total radiation dose, operative time, average time to establish a single channel, and number of channel adjustments. Results: The mean deviation of guide pin placement in the RG was significantly smaller than that in the CG (0.86 ± 0.57 mm vs. 2.55 ± 1.88 mm, P < 0.001). The RG also had significantly fewer cumulative number of exposures (4.56 ± 1.70 vs. 13.38 ± 19.01, P = 0.003) and lower total radiation doses (7.35 ± 3.33 μSv vs. 30.28 ± 97.41 μSv, P = 0.024). The operative time was similar between the groups (245.03 ± 67.06 min vs. 215.18 ± 83.08 min, P = 0.083). The number of channel adjustments was significantly lower in the RG (0.06 ± 0.29 vs. 0.28 ± 0.90 , P = 0.014). There were no significant differences in the incidence of adverse events between the two groups. Conclusions: The robotic system with biplane fluoroscopic positioning improved guide pin accuracy and reduced radiation exposure, indicating its potential to enhance precision and safety in spinal surgery.
- Open Access
- 12 May 2025
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 111 (6) , 3886-3894
Superior accuracy of femoral bone tunnel drilling in robot-assisted anterior cruciate ligament reconstruction: a multicenter, randomized, controlled trial
Purpose: To assess the efficacy and safety for bone tunnel drilling in anatomic anterior cruciate ligament (ACL) reconstruction with the assistance of a surgical navigation robot system. Methods: A total of 79 patients were randomized to either surgical navigation robot group (robot group, n = 39) or traditional handheld locator group (control group, n = 40). The robot group underwent anatomic ACL reconstruction using a surgical navigation robot, while the control group underwent the procedure using a traditional handheld locator. Postoperative three-dimensional computed tomography was used to measure the tibial and femoral tunnel position, as well as the tibial and femoral tunnel length. The success rate of femoral tunnel positioning was defined as the proportion of cases in which the femoral tunnel was placed accurately within the ideal anatomical position. Results: The success rate of femoral tunnel positioning in the robot group was significantly higher than that in the control group (82.1% vs 50%, P = 0.003). The surgical time in the robot group was significantly longer than that in the control group (122.8 min ± 34.9 min vs 84.0 min ± 28.3 min, P = 0.05). The incidence rate of adverse events did not show statistical significance between the two groups (P = 0.830). There were no adverse events associated with the instruments or any serious adverse events, and no patients withdrew from the trial due to adverse events. Conclusions: The success rate for femoral tunnel positioning in anatomic ACL reconstruction was higher with surgical navigation robots compared to the traditional handheld locator. Surgical navigation robot systems are safe tools in anatomic ACL reconstruction surgery.
- 12 May 2025
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 111 (6) , 3886-3894
Open AccessSuperior accuracy of femoral bone tunnel drilling in robot-assisted anterior cruciate ligament reconstruction: a multicenter, randomized, controlled trial
Purpose: To assess the efficacy and safety for bone tunnel drilling in anatomic anterior cruciate ligament (ACL) reconstruction with the assistance of a surgical navigation robot system. Methods: A total of 79 patients were randomized to either surgical navigation robot group (robot group, n = 39) or traditional handheld locator group (control group, n = 40). The robot group underwent anatomic ACL reconstruction using a surgical navigation robot, while the control group underwent the procedure using a traditional handheld locator. Postoperative three-dimensional computed tomography was used to measure the tibial and femoral tunnel position, as well as the tibial and femoral tunnel length. The success rate of femoral tunnel positioning was defined as the proportion of cases in which the femoral tunnel was placed accurately within the ideal anatomical position. Results: The success rate of femoral tunnel positioning in the robot group was significantly higher than that in the control group (82.1% vs 50%, P = 0.003). The surgical time in the robot group was significantly longer than that in the control group (122.8 min ± 34.9 min vs 84.0 min ± 28.3 min, P = 0.05). The incidence rate of adverse events did not show statistical significance between the two groups (P = 0.830). There were no adverse events associated with the instruments or any serious adverse events, and no patients withdrew from the trial due to adverse events. Conclusions: The success rate for femoral tunnel positioning in anatomic ACL reconstruction was higher with surgical navigation robots compared to the traditional handheld locator. Surgical navigation robot systems are safe tools in anatomic ACL reconstruction surgery.
- Open Access
- 24 March 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 338
Surgical Robots Improve Tunnel Angle and Graft Bending Angle in Anatomic ACL Reconstruction: A Multicenter Study
The anatomic characteristics of the graft and tunnel, i.e., the tunnel position, angle, length, and the graft bending angle, influence knee joint stability and postoperative functional recovery. The purpose of this study was to evaluate the tunnel position, length and angle, as well as graft bending angle after ACL reconstruction assisted by a surgical robot. A total of 70 patients were randomized into two groups: the surgical robot group (robot group, n = 35) and the traditional handheld locator group (control group, n = 35). Postoperative computed tomography (CT) was employed to assess the positions and lengths of the tunnels, as well as the tunnel angle and the graft bending angle. Additionally, the posterior wall distance was measured by determining the minimum vertical distance from the long axis of the tunnel to the posterior wall region. There were no significant differences between the two groups in the mean position or length of the femoral and tibial tunnel (p > 0.05). However, the femoral tunnel angle was significantly larger in the robot group compared to the handheld locator group (p = 0.012). The graft bending angle was significantly less acute in the robot group than in the control group (p = 0.008). Additionally, the posterior wall distance was significantly greater in the robot group compared to the control group (p < 0.001). The results suggest that surgical robot-assisted ACL reconstruction enhances safety in the inclination of the tunnel and graft, helping to avoid potential biomechanical issues such as the wiper effect and the bungee effect, which may lead to tunnel widening and surgical failure.
- 24 March 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 338
Open AccessSurgical Robots Improve Tunnel Angle and Graft Bending Angle in Anatomic ACL Reconstruction: A Multicenter Study
The anatomic characteristics of the graft and tunnel, i.e., the tunnel position, angle, length, and the graft bending angle, influence knee joint stability and postoperative functional recovery. The purpose of this study was to evaluate the tunnel position, length and angle, as well as graft bending angle after ACL reconstruction assisted by a surgical robot. A total of 70 patients were randomized into two groups: the surgical robot group (robot group, n = 35) and the traditional handheld locator group (control group, n = 35). Postoperative computed tomography (CT) was employed to assess the positions and lengths of the tunnels, as well as the tunnel angle and the graft bending angle. Additionally, the posterior wall distance was measured by determining the minimum vertical distance from the long axis of the tunnel to the posterior wall region. There were no significant differences between the two groups in the mean position or length of the femoral and tibial tunnel (p > 0.05). However, the femoral tunnel angle was significantly larger in the robot group compared to the handheld locator group (p = 0.012). The graft bending angle was significantly less acute in the robot group than in the control group (p = 0.008). Additionally, the posterior wall distance was significantly greater in the robot group compared to the control group (p < 0.001). The results suggest that surgical robot-assisted ACL reconstruction enhances safety in the inclination of the tunnel and graft, helping to avoid potential biomechanical issues such as the wiper effect and the bungee effect, which may lead to tunnel widening and surgical failure.
- Open Access
- 20 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 214
Different Spatial Characteristic Changes in Lumbopelvic Kinematics Before and After Fatigue: Comparison Between People with and Without Low Back Pain
Background: The lumbopelvic region plays a pivotal role in enabling various functional activities. This study quantified and compared the kinematic changes between healthy individuals and patients with recurrent low back pain (LBP) in both rested and fatigued states to gain insight into the kinematic adaptation and mechanisms underlying kinematic variations that occur in the presence of these factors. Methods: Participants were divided into two groups: the LBP (n = 23) and healthy control groups (n = 19). Dynamic lumbopelvic measurements were taken using a biplane radiography image system while the participants performed weight-bearing forward-backward bending before and after fatigue. All lumbopelvic kinematics were described as the three-dimensional motion of the vertebra relative to the pelvis and were measured at normalized time intervals from maximum extension to approximately 45° of flexion. Results: Repetitive lifting- and lowering-induced fatigue significantly affected lumbopelvic kinematics in the anterior/posterior translation (mm) and rotation around the z-axis in both healthy individuals and patients with LBP (p < 0.05). In healthy individuals, significant differences occurred in approximately 13–83% of the forward-backward bending cycle (0–100%), whereas, in patients with LBP, significant differences mainly occurred in 61–93% of the cycle (p < 0.01). Conclusions: The lumbopelvic kinematic changes observed in both LBP patients and healthy individuals after fatigue may indicate protective compensation or vulnerability and could play a role in LBP dysfunction.
- 20 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 214
Open AccessDifferent Spatial Characteristic Changes in Lumbopelvic Kinematics Before and After Fatigue: Comparison Between People with and Without Low Back Pain
Background: The lumbopelvic region plays a pivotal role in enabling various functional activities. This study quantified and compared the kinematic changes between healthy individuals and patients with recurrent low back pain (LBP) in both rested and fatigued states to gain insight into the kinematic adaptation and mechanisms underlying kinematic variations that occur in the presence of these factors. Methods: Participants were divided into two groups: the LBP (n = 23) and healthy control groups (n = 19). Dynamic lumbopelvic measurements were taken using a biplane radiography image system while the participants performed weight-bearing forward-backward bending before and after fatigue. All lumbopelvic kinematics were described as the three-dimensional motion of the vertebra relative to the pelvis and were measured at normalized time intervals from maximum extension to approximately 45° of flexion. Results: Repetitive lifting- and lowering-induced fatigue significantly affected lumbopelvic kinematics in the anterior/posterior translation (mm) and rotation around the z-axis in both healthy individuals and patients with LBP (p < 0.05). In healthy individuals, significant differences occurred in approximately 13–83% of the forward-backward bending cycle (0–100%), whereas, in patients with LBP, significant differences mainly occurred in 61–93% of the cycle (p < 0.01). Conclusions: The lumbopelvic kinematic changes observed in both LBP patients and healthy individuals after fatigue may indicate protective compensation or vulnerability and could play a role in LBP dysfunction.
- 24 July 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (2) , 428-438
Anatomic double‐bundle transtibial anterior cruciate ligament reconstruction restores graft length changes but leads to larger graft bending angles
Purpose: The purpose of this study was to evaluate the femoral tunnel position using a modified anatomic transtibial (TT) double‐bundle anterior cruciate ligament reconstruction (DBACLR) and to investigate the knee kinematics, graft length and graft bending angle following DBACLR.Methods: Ten patients who underwent DBACLR using the modified TT technique were included in the study. All patients performed a single‐legged lunge under a dual fluoroscopic imaging system to assess the 6 degrees of freedom tibiofemoral kinematics. Femoral tunnel position was evaluated via postoperative three‐dimensional (3D) computed tomography. The area centroids of anteromedial (AM) and posterolateral (PL) bundles were determined on 3D knee models. The lengths of AM and PL bundles, as well as graft bending angle at the femoral tunnel aperture, were measured by created virtual fibres.Results: The reconstructed knee rotated more externally compared with the contralateral knee between 0° and 60° (p ≤ 0.049). There is no significant difference in the length change of AM bundle (n.s.) and PL bundle (n.s.) between the two sides from 0° to 120° during the lunge motion. The maximum graft bending angle at the femoral tunnel aperture occurred at 0° of knee flexion, with the AM graft bending angle was 72.6° ± 9.0° and the PL graft bending angle was 90.3° ± 9.7°.Conclusion: The modified TT technique used in this study could achieve anatomical ACL reconstruction, restoring graft length change patterns compared to contralateral knees. However, residual rotational instability of the reconstructed knee was observed after DBACLR, despite achieving anatomic tunnel placement. Therefore, double‐bundle reconstruction may not sufficiently address the persistent rotational instability of the knee. Additionally, larger graft bending angles at the femoral tunnel aperture were found with the modified TT technique. Therefore, further improvement to the TT technique should focus on reducing the graft's curvature while maintaining the anatomical properties of the knee joint. The findings of this study highlight the need for improved surgical techniques to address residual rotational instability and optimise graft curvature. These improvements are crucial for enhancing patient outcomes and long‐term joint function following ACL reconstruction.Levels of Evidence: Level II.
- 24 July 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (2) , 428-438
Anatomic double‐bundle transtibial anterior cruciate ligament reconstruction restores graft length changes but leads to larger graft bending angles
Purpose: The purpose of this study was to evaluate the femoral tunnel position using a modified anatomic transtibial (TT) double‐bundle anterior cruciate ligament reconstruction (DBACLR) and to investigate the knee kinematics, graft length and graft bending angle following DBACLR.Methods: Ten patients who underwent DBACLR using the modified TT technique were included in the study. All patients performed a single‐legged lunge under a dual fluoroscopic imaging system to assess the 6 degrees of freedom tibiofemoral kinematics. Femoral tunnel position was evaluated via postoperative three‐dimensional (3D) computed tomography. The area centroids of anteromedial (AM) and posterolateral (PL) bundles were determined on 3D knee models. The lengths of AM and PL bundles, as well as graft bending angle at the femoral tunnel aperture, were measured by created virtual fibres.Results: The reconstructed knee rotated more externally compared with the contralateral knee between 0° and 60° (p ≤ 0.049). There is no significant difference in the length change of AM bundle (n.s.) and PL bundle (n.s.) between the two sides from 0° to 120° during the lunge motion. The maximum graft bending angle at the femoral tunnel aperture occurred at 0° of knee flexion, with the AM graft bending angle was 72.6° ± 9.0° and the PL graft bending angle was 90.3° ± 9.7°.Conclusion: The modified TT technique used in this study could achieve anatomical ACL reconstruction, restoring graft length change patterns compared to contralateral knees. However, residual rotational instability of the reconstructed knee was observed after DBACLR, despite achieving anatomic tunnel placement. Therefore, double‐bundle reconstruction may not sufficiently address the persistent rotational instability of the knee. Additionally, larger graft bending angles at the femoral tunnel aperture were found with the modified TT technique. Therefore, further improvement to the TT technique should focus on reducing the graft's curvature while maintaining the anatomical properties of the knee joint. The findings of this study highlight the need for improved surgical techniques to address residual rotational instability and optimise graft curvature. These improvements are crucial for enhancing patient outcomes and long‐term joint function following ACL reconstruction.Levels of Evidence: Level II.
- 29 May 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 129 (1) , 104190
Optimal tibial tunnel angulation for anatomical anterior cruciate ligament reconstruction using transtibial technique
Numerous studies have suggested that the primary cause of failure in transtibial anterior cruciate ligament reconstruction (ACLR) is often attributed to non-anatomical placement of the bone tunnels, typically resulting from improper tibial guidance. We aimed to establish the optimal tibial tunnel angle for anatomical ACLR by adapting the transtibial (TT) technique. Additionally, we aimed to assess graft bending angle (GBA) and length changes during in vivo dynamic flexion of the knee. Twenty knee joints underwent a CT scan and dual fluoroscopic imaging system (DFIS) to reproduce relative knee position during dynamic flexion. For the single-legged lunge, subjects began in a natural standing position and flexed the right knee beyond 90° When performing the lunge task, the subject supported the body weight on the right leg, while the left leg was used to keep the balance. The tibial and femoral tunnels were established on each knee using a modified TT technique for single-bundle ACLR. The tibial tunnel angulation to the tibial axis and the sagittal plane were measured. Considering that ACL injuries tend to occur at low knee flexion angles, GBA and graft length were measured between 0° and 90° of flexion in this study. The tibial tunnel angulated the sagittal plane at 42.8° ± 3.4°, and angulated the tibial axis at 45.3° ± 5.1° The GBA was 0° at 90° flexion of the knee and increased substantially to 76.4 ± 5.5° at 0° flexion. The GBA significantly increased with the knee extending from 90° to 0° (p < 0.001). The ACL length was 30.2mm±3.0 mm at 0° flexion and decreased to 27.5mm ± 2.8 mm at 90° flexion (p = 0.072). To achieve anatomic single-bundle ACLR, the optimal tibial tunnel should be angulated at approximately 43° to the sagittal plane and approximately 45° to the tibial axis using the modified TT technique. What's more, anatomical TT ACLR resulted in comparable GBA and a relatively constant ACL length from 0° to 90° of flexion. These findings provide theoretical support for the clinical application and the promotion of the current modified TT technique with the assistance of a robot to achieve anatomical ACLR.
- 29 May 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 129 (1) , 104190
Optimal tibial tunnel angulation for anatomical anterior cruciate ligament reconstruction using transtibial technique
Numerous studies have suggested that the primary cause of failure in transtibial anterior cruciate ligament reconstruction (ACLR) is often attributed to non-anatomical placement of the bone tunnels, typically resulting from improper tibial guidance. We aimed to establish the optimal tibial tunnel angle for anatomical ACLR by adapting the transtibial (TT) technique. Additionally, we aimed to assess graft bending angle (GBA) and length changes during in vivo dynamic flexion of the knee. Twenty knee joints underwent a CT scan and dual fluoroscopic imaging system (DFIS) to reproduce relative knee position during dynamic flexion. For the single-legged lunge, subjects began in a natural standing position and flexed the right knee beyond 90° When performing the lunge task, the subject supported the body weight on the right leg, while the left leg was used to keep the balance. The tibial and femoral tunnels were established on each knee using a modified TT technique for single-bundle ACLR. The tibial tunnel angulation to the tibial axis and the sagittal plane were measured. Considering that ACL injuries tend to occur at low knee flexion angles, GBA and graft length were measured between 0° and 90° of flexion in this study. The tibial tunnel angulated the sagittal plane at 42.8° ± 3.4°, and angulated the tibial axis at 45.3° ± 5.1° The GBA was 0° at 90° flexion of the knee and increased substantially to 76.4 ± 5.5° at 0° flexion. The GBA significantly increased with the knee extending from 90° to 0° (p < 0.001). The ACL length was 30.2mm±3.0 mm at 0° flexion and decreased to 27.5mm ± 2.8 mm at 90° flexion (p = 0.072). To achieve anatomic single-bundle ACLR, the optimal tibial tunnel should be angulated at approximately 43° to the sagittal plane and approximately 45° to the tibial axis using the modified TT technique. What's more, anatomical TT ACLR resulted in comparable GBA and a relatively constant ACL length from 0° to 90° of flexion. These findings provide theoretical support for the clinical application and the promotion of the current modified TT technique with the assistance of a robot to achieve anatomical ACLR.
- 8 January 2022
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (4) , 837-843
Differences in patellofemoral kinematics between weightbearing and non-weightbearing conditions in patients with arthrofibrosis after anterior cruciate ligament reconstruction
Objective The purpose of this study is to evaluate the difference of patellofemoral kinematics between weightbearing and non-weightbearing conditions in the arthrofibrotic knee after anterior cruciate ligament (ACL) reconstruction. Methods Twenty patients with arthrofibrosis after ACL reconstruction were included in the study. Computed tomography scanner and dual fluoroscopic imaging techniques were used to compare patellofemoral kinematics of the affected knee between weightbearing knee flexion and non-weightbearing knee flexion. In both positions, patellofemoral kinematics in six degrees-of-freedom (6 DOF) were measured respectively. Results The patellar lateral tilt angle (p = 0.007) and medial patellar translation (p = 0.043) under the weightbearing condition were significantly decreased compared to the non-weightbearing task between 5° and 15° of knee flexion. The lateral patellar translation during a non-weightbearing task was significantly decreased between 60° and 75° of knee flexion (p = 0.005), and the inferior patellar translation under the weightbearing condition was significantly increased between 45° and 75° of knee flexion (p = 0.040). Conclusion These results indicate that patellofemoral kinematics during non-weightbearing positions do not sufficiently represent the patellar tracking during functional weightbearing activities. Our findings of this study establish the clinical relevance and significance of assessing the patellofemoral kinematics under the weightbearing condition when evaluating patients with arthrofibrosis after ACL reconstruction. Trial registration Trial registration number: ChiCTR1900025977.
- 8 January 2022
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (4) , 837-843
Differences in patellofemoral kinematics between weightbearing and non-weightbearing conditions in patients with arthrofibrosis after anterior cruciate ligament reconstruction
Objective The purpose of this study is to evaluate the difference of patellofemoral kinematics between weightbearing and non-weightbearing conditions in the arthrofibrotic knee after anterior cruciate ligament (ACL) reconstruction. Methods Twenty patients with arthrofibrosis after ACL reconstruction were included in the study. Computed tomography scanner and dual fluoroscopic imaging techniques were used to compare patellofemoral kinematics of the affected knee between weightbearing knee flexion and non-weightbearing knee flexion. In both positions, patellofemoral kinematics in six degrees-of-freedom (6 DOF) were measured respectively. Results The patellar lateral tilt angle (p = 0.007) and medial patellar translation (p = 0.043) under the weightbearing condition were significantly decreased compared to the non-weightbearing task between 5° and 15° of knee flexion. The lateral patellar translation during a non-weightbearing task was significantly decreased between 60° and 75° of knee flexion (p = 0.005), and the inferior patellar translation under the weightbearing condition was significantly increased between 45° and 75° of knee flexion (p = 0.040). Conclusion These results indicate that patellofemoral kinematics during non-weightbearing positions do not sufficiently represent the patellar tracking during functional weightbearing activities. Our findings of this study establish the clinical relevance and significance of assessing the patellofemoral kinematics under the weightbearing condition when evaluating patients with arthrofibrosis after ACL reconstruction. Trial registration Trial registration number: ChiCTR1900025977.
- Open Access
Prognostic factor analysis in patients with temporomandibular disorders after reversible treatment: study protocol for a prospective cohort study in China
Introduction Temporomandibular disorders (TMDs) are complex multifactorial disorders. Reversible treatment has been suggested for the initial management of TMD; however, comparable therapeutic effects of different reversible intervention modalities remain controversial. Various biopsychosocial factors, which may be putative prognostic factors that influence the response to reversible treatment for TMD, have been reported to increase the risk of developing first-onset TMD. However, there is a paucity of research that aims to identify prognostic factors associated with the clinical outcomes of reversible treatment in people with TMD. The objective of this prospective cohort study is to identify prognostic factors that are associated with clinical outcomes of reversible treatment in patients with TMD and to analyse the risk factors that influence the development of chronic TMD. Methods and analysis We plan to recruit 834 patients with TMD who meet the inclusion criteria. Once informed consent is obtained, baseline data, including anamnestic data, physical assessments and self-report questionnaires, will be collected from participants at their first clinic visit; subsequently, they will receive 1–4 weeks of reversible treatment. The primary treatment outcome measures will be a change in the anterior maximum mouth opening, worsening of TMD pain scores assessed using a visual analogue scale (VAS) and a reduction in characteristic pain intensity. A good outcome will be defined as an anterior maximal opening ≥35 mm and at least a 30% reduction in VAS scores 3 months after baseline. The association between candidate prognostic factors and clinical outcomes of reversible TMD treatment will be analysed. Ethics and dissemination The protocol has been approved by the Ethics Committee of Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China, based on the guidelines outlined in the Declaration of Helsinki (SH9H-2019-T316-4). The results of this study will be reported in accordance with the Strengthening the Reporting of Observational Studies in Epidemiology statement. The authors intend to publish the results in a peer-reviewed journal. Trial registration number ChiCTR2000033328.
Open AccessPrognostic factor analysis in patients with temporomandibular disorders after reversible treatment: study protocol for a prospective cohort study in China
Introduction Temporomandibular disorders (TMDs) are complex multifactorial disorders. Reversible treatment has been suggested for the initial management of TMD; however, comparable therapeutic effects of different reversible intervention modalities remain controversial. Various biopsychosocial factors, which may be putative prognostic factors that influence the response to reversible treatment for TMD, have been reported to increase the risk of developing first-onset TMD. However, there is a paucity of research that aims to identify prognostic factors associated with the clinical outcomes of reversible treatment in people with TMD. The objective of this prospective cohort study is to identify prognostic factors that are associated with clinical outcomes of reversible treatment in patients with TMD and to analyse the risk factors that influence the development of chronic TMD. Methods and analysis We plan to recruit 834 patients with TMD who meet the inclusion criteria. Once informed consent is obtained, baseline data, including anamnestic data, physical assessments and self-report questionnaires, will be collected from participants at their first clinic visit; subsequently, they will receive 1–4 weeks of reversible treatment. The primary treatment outcome measures will be a change in the anterior maximum mouth opening, worsening of TMD pain scores assessed using a visual analogue scale (VAS) and a reduction in characteristic pain intensity. A good outcome will be defined as an anterior maximal opening ≥35 mm and at least a 30% reduction in VAS scores 3 months after baseline. The association between candidate prognostic factors and clinical outcomes of reversible TMD treatment will be analysed. Ethics and dissemination The protocol has been approved by the Ethics Committee of Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China, based on the guidelines outlined in the Declaration of Helsinki (SH9H-2019-T316-4). The results of this study will be reported in accordance with the Strengthening the Reporting of Observational Studies in Epidemiology statement. The authors intend to publish the results in a peer-reviewed journal. Trial registration number ChiCTR2000033328.