Dong Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dong Li has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Tiantian Xu
Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, P. R. China
4 shared publications - Xinyu Wu
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
3 shared publications - Chenyang Huang
Chinese Academy of Sciences
2 shared publications - Sheng Xu
Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
2 shared publications - Binghan Chen
Guangdong Provincial Key Lab of Robotics and Intelligent System, Shenzhen Institute of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen, China
1 shared publication - Chenguang Yang
The Hong Kong Polytechnic University
1 shared publication
Latest Publications
- Top Cited Papers
- 17 September 2025
- Published by Springer Nature in Nature
- Vol. 645 (8081) , 648-655
A movable long-term implantable soft microfibre for dynamic bioelectronics
Long-term implantable bioelectronics offer a powerful means to evaluate the function of the nervous system and serve as effective human–machine interfaces1,2,3. Here, inspired by earthworms, we introduce NeuroWorm—a soft, stretchable and movable fibre sensor designed for bioelectronic interface. Our approach involves rolling to transform 2D bioelectronic devices into 1D NeuroWorm, creating a multifunctional microfibre that houses longitudinally distributed electrode arrays for both bioelectrical and biomechanical monitoring. NeuroWorm effectively records high-quality spatio-temporal signals in situ while steerably advancing within the brain or on the muscle as needed. This allows for the dynamic targeting and shifting of desired monitoring sites. Implanted in muscle through a tiny incision, NeuroWorm provides stable bioelectrical monitoring in rats for more than 43 weeks. Even after 54 weeks of implantation in muscle, fibroblast encapsulation around the fibre remains negligible. Our NeuroWorm represents a platform that promotes a substantial advance in bioelectronics—from an immobile probe fixed in place to active, intelligent and living devices for long-term, minimally invasive and mobile evaluation of the nervous system.
- 17 September 2025
- Published by Springer Nature in Nature
- Vol. 645 (8081) , 648-655
Top Cited PapersA movable long-term implantable soft microfibre for dynamic bioelectronics
Long-term implantable bioelectronics offer a powerful means to evaluate the function of the nervous system and serve as effective human–machine interfaces1,2,3. Here, inspired by earthworms, we introduce NeuroWorm—a soft, stretchable and movable fibre sensor designed for bioelectronic interface. Our approach involves rolling to transform 2D bioelectronic devices into 1D NeuroWorm, creating a multifunctional microfibre that houses longitudinally distributed electrode arrays for both bioelectrical and biomechanical monitoring. NeuroWorm effectively records high-quality spatio-temporal signals in situ while steerably advancing within the brain or on the muscle as needed. This allows for the dynamic targeting and shifting of desired monitoring sites. Implanted in muscle through a tiny incision, NeuroWorm provides stable bioelectrical monitoring in rats for more than 43 weeks. Even after 54 weeks of implantation in muscle, fibroblast encapsulation around the fibre remains negligible. Our NeuroWorm represents a platform that promotes a substantial advance in bioelectronics—from an immobile probe fixed in place to active, intelligent and living devices for long-term, minimally invasive and mobile evaluation of the nervous system.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (5) , 3560-3571
An Automatic Magnetically Robotic System Using a Double-Loop Stable Control Method for Guidewire Steering
Magnetically steerable endovascular guidewire robotic systems that are capable of automatic agile navigation have great potential for medical applications, such as endovascular interventional surgery. In addition, the guidewire robotic systems save doctors from radiation exposure. Some magnetic endovascular guidewires have been designed by researchers. However, they are primarily open-loop controlled. This article aims to investigate methods of closed-loop control of a magnetic endovascular guidewire. First, a new fully automatic magnetic guidewire steering system is developed, including a flexible industrial robot arm, and then, the guidewire steering problem is formulated and modeled with physical and mathematical analysis. Second, a double-loop magnetic control strategy, including the velocity (outer controller) and direction controllers (inner controller), is proposed using the exponential sliding mode control method. Meanwhile, the system stability is analyzed based on the Lyapunov theory and the stable controller parameter constraints are obtained. Simulation examples verify that the proposed controller has no overshot problem, which can significantly avoid vessel damage. Finally, the experimental examples demonstrate the effectiveness of our proposed method, which has significant value for practical surgical applications in near future.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (5) , 3560-3571
An Automatic Magnetically Robotic System Using a Double-Loop Stable Control Method for Guidewire Steering
Magnetically steerable endovascular guidewire robotic systems that are capable of automatic agile navigation have great potential for medical applications, such as endovascular interventional surgery. In addition, the guidewire robotic systems save doctors from radiation exposure. Some magnetic endovascular guidewires have been designed by researchers. However, they are primarily open-loop controlled. This article aims to investigate methods of closed-loop control of a magnetic endovascular guidewire. First, a new fully automatic magnetic guidewire steering system is developed, including a flexible industrial robot arm, and then, the guidewire steering problem is formulated and modeled with physical and mathematical analysis. Second, a double-loop magnetic control strategy, including the velocity (outer controller) and direction controllers (inner controller), is proposed using the exponential sliding mode control method. Meanwhile, the system stability is analyzed based on the Lyapunov theory and the stable controller parameter constraints are obtained. Simulation examples verify that the proposed controller has no overshot problem, which can significantly avoid vessel damage. Finally, the experimental examples demonstrate the effectiveness of our proposed method, which has significant value for practical surgical applications in near future.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (5) , 3572-3583
Cooperative Control Strategy of Multiple Magnetic Millirobots for Automatic Assembly
Cooperative control of multiple small-scale robots significantly increases capability compared to a single one. However, multiple robots driven by the same magnetic field receive the same input signal, causing hardly different responses. In our previous work, multiple robots with heterogeneous magnetization angles could be at the same velocity or only one could move and the others not. However, cooperatively controlling multiple robots in the same magnetic field remains a challenge because of the difficulty of arbitrarily adjusting the velocity relationships of multiple robots. In this work, we propose a novel cooperative control strategy of multiple magnetic millirobots based on their velocity difference for the automatic manipulation and assembly of objects. The velocity difference between the multiple millirobots with different magnetization angles is modeled and controlled by the inclination angle of the external oscillating magnetic field. We developed a differential wheel-inspired cooperative control method of a two- or four-millirobot team for cooperative object transport in closed-loop control. Considering the efficiency and collision avoidance of high-precision assembly of multiple objects, an optimal task allocation method based on the shortest total transport path and an improved sampling-based path planning method in real-time are proposed. Experiments demonstrated two and four-millirobots were able to cooperatively transport objects of different shapes with a maximum mass of 16 times that of a single robot. Furthermore, the multimillirobot team could autonomously assemble three strip objects to the desired shape with a position error of less than 2.16 mm and an orientation angle error of fewer than 5.07 $^\circ$ .
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (5) , 3572-3583
Cooperative Control Strategy of Multiple Magnetic Millirobots for Automatic Assembly
Cooperative control of multiple small-scale robots significantly increases capability compared to a single one. However, multiple robots driven by the same magnetic field receive the same input signal, causing hardly different responses. In our previous work, multiple robots with heterogeneous magnetization angles could be at the same velocity or only one could move and the others not. However, cooperatively controlling multiple robots in the same magnetic field remains a challenge because of the difficulty of arbitrarily adjusting the velocity relationships of multiple robots. In this work, we propose a novel cooperative control strategy of multiple magnetic millirobots based on their velocity difference for the automatic manipulation and assembly of objects. The velocity difference between the multiple millirobots with different magnetization angles is modeled and controlled by the inclination angle of the external oscillating magnetic field. We developed a differential wheel-inspired cooperative control method of a two- or four-millirobot team for cooperative object transport in closed-loop control. Considering the efficiency and collision avoidance of high-precision assembly of multiple objects, an optimal task allocation method based on the shortest total transport path and an improved sampling-based path planning method in real-time are proposed. Experiments demonstrated two and four-millirobots were able to cooperatively transport objects of different shapes with a maximum mass of 16 times that of a single robot. Furthermore, the multimillirobot team could autonomously assemble three strip objects to the desired shape with a position error of less than 2.16 mm and an orientation angle error of fewer than 5.07 $^\circ$ .
- 8 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Cybernetics
- Vol. 53 (9) , 6053-6065
A Robot Motion Learning Method Using Broad Learning System Verified by Small-Scale Fish-Like Robot
The widespread application of learning-based methods in robotics has allowed significant simplifications to controller design and parameter adjustment. In this article, robot motion is controlled with learning-based methods. A control policy using a broad learning system (BLS) for robot point-reaching motion is developed. A sample application based on a magnetic small-scale robotic system is designed without detailed mathematical modeling of the dynamic systems. The parameter constraints of the nodes in the BLS-based controller are derived based on Lyapunov theory. The design and control training processes for a small-scale magnetic fish motion are presented. Finally, the effectiveness of the proposed method is demonstrated by convergence of the artificial magnetic fish motion to the targeted area with the BLS trajectory, successfully avoiding obstacles.
- 8 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Cybernetics
- Vol. 53 (9) , 6053-6065
A Robot Motion Learning Method Using Broad Learning System Verified by Small-Scale Fish-Like Robot
The widespread application of learning-based methods in robotics has allowed significant simplifications to controller design and parameter adjustment. In this article, robot motion is controlled with learning-based methods. A control policy using a broad learning system (BLS) for robot point-reaching motion is developed. A sample application based on a magnetic small-scale robotic system is designed without detailed mathematical modeling of the dynamic systems. The parameter constraints of the nodes in the BLS-based controller are derived based on Lyapunov theory. The design and control training processes for a small-scale magnetic fish motion are presented. Finally, the effectiveness of the proposed method is demonstrated by convergence of the artificial magnetic fish motion to the targeted area with the BLS trajectory, successfully avoiding obstacles.