Udaya Kumar Kakarla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Udaya Kumar Kakarla has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Jay D. Turner
Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
3 shared publicationsMichael A. Bohl
Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
3 shared publicationsSteve W. Chang
Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
3 shared publicationsDavid S. Xu
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
2 shared publicationsJuan S. Uribe
Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
2 shared publicationsRandall J. Hlubek
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
2 shared publications
Latest Publications
- Open Access
- 23 June 2019
- Published by SAGE Publications in Global Spine Journal
- Vol. 10 (4) , 419-424
Range of Motion Testing of a Novel 3D-Printed Synthetic Spine Model
Study Design: Biomechanical model study. Objective: The Barrow Biomimetic Spine (BBS) project is a resident-driven effort to manufacture a synthetic spine model with high biomechanical fidelity to human tissue. The purpose of this study was to investigate the performance of the current generation of BBS models on biomechanical testing of range of motion (ROM) and axial compression and to compare the performance of these models to historical cadaveric data acquired using the same testing protocol. Methods: Six synthetic spine models comprising L3-5 segments were manufactured with variable soft-tissue densities and print orientations. Models underwent torque loading to a maximum of 7.5 N m. Torques were applied to the models in flexion-extension, lateral bending, axial rotation, and axial compression. Results were compared with historic cadaveric control data. Results: Each model demonstrated steadily decreasing ROM on flexion-extension testing with increasing density of the intervertebral discs and surrounding ligamentous structures. Vertically printed models demonstrated markedly less ROM than equivalent models printed horizontally at both L3-4 (5.0° vs 14.0°) and L4-5 (3.9° vs 15.2°). Models D and E demonstrated ROM values that bracketed the cadaveric controls at equivalent torque loads (7.5 N m). Conclusions: This study identified relevant variables that affect synthetic spine model ROM and compressibility, confirmed that the models perform predictably with changes in these print variables, and identified a set of model parameters that result in a synthetic model with overall ROM that approximates that of a cadaveric model. Future studies can be undertaken to refine model performance and determine intermodel variability.
- 23 June 2019
- Published by SAGE Publications in Global Spine Journal
- Vol. 10 (4) , 419-424
Open AccessRange of Motion Testing of a Novel 3D-Printed Synthetic Spine Model
Study Design: Biomechanical model study. Objective: The Barrow Biomimetic Spine (BBS) project is a resident-driven effort to manufacture a synthetic spine model with high biomechanical fidelity to human tissue. The purpose of this study was to investigate the performance of the current generation of BBS models on biomechanical testing of range of motion (ROM) and axial compression and to compare the performance of these models to historical cadaveric data acquired using the same testing protocol. Methods: Six synthetic spine models comprising L3-5 segments were manufactured with variable soft-tissue densities and print orientations. Models underwent torque loading to a maximum of 7.5 N m. Torques were applied to the models in flexion-extension, lateral bending, axial rotation, and axial compression. Results were compared with historic cadaveric control data. Results: Each model demonstrated steadily decreasing ROM on flexion-extension testing with increasing density of the intervertebral discs and surrounding ligamentous structures. Vertically printed models demonstrated markedly less ROM than equivalent models printed horizontally at both L3-4 (5.0° vs 14.0°) and L4-5 (3.9° vs 15.2°). Models D and E demonstrated ROM values that bracketed the cadaveric controls at equivalent torque loads (7.5 N m). Conclusions: This study identified relevant variables that affect synthetic spine model ROM and compressibility, confirmed that the models perform predictably with changes in these print variables, and identified a set of model parameters that result in a synthetic model with overall ROM that approximates that of a cadaveric model. Future studies can be undertaken to refine model performance and determine intermodel variability.
- 24 November 2018
- Published by Wiley in Clinical Anatomy
- Vol. 32 (3) , 348-353
Posterior open‐wedge anterior longitudinal ligament release: Cadaveric technique analysis
Anterior column release is a powerful surgical technique for achieving spinopelvic balance in adult patients with sagittal plane deformities. We present an alternative strategy for focal deformity correction from a posterior‐only approach. The purpose of this study was to evaluate the feasibility and efficacy of a novel surgical technique called posterior open‐wedge diskectomy and anterior longitudinal ligament (ALL) release (POWAR). A cadaveric torso underwent POWARs at the L1‐L4 intervertebral disc spaces. Baseline measurements of end‐plate angle (EPA), anterior intervertebral disc height (ADH), and posterior intervertebral disc height (PDH) were obtained. These measurements were repeated after three stages of correction: posterior column compression alone, posterior column compression following Schwab grade 2 osteotomies, and posterior column compression following POWAR. A second cadaver underwent posterolateral spinal dissection to demonstrate the pertinent anatomical features relevant to this novel procedure. With each stage of correction, a sequential increase in EPA and ADH and a decrease in PDH were demonstrated. The large increase in ADH seen following POWAR confirmed successful release of the ALL. In situ investigation of the aorta and inferior vena cava following anterior exposure revealed no injury to the great vessels or surrounding structures. Ex vivo testing of the aorta and inferior vena cava took place at the L3‐4 level. This testing demonstrated no injury or tears to either vessel. POWAR is a new surgical technique that can provide an alternative to three‐column osteotomy for surgeons performing spinal reconstructions in adults through an open, posterior‐only approach. Clin. Anat. 32:348–353, 2019.
- 24 November 2018
- Published by Wiley in Clinical Anatomy
- Vol. 32 (3) , 348-353
Posterior open‐wedge anterior longitudinal ligament release: Cadaveric technique analysis
Anterior column release is a powerful surgical technique for achieving spinopelvic balance in adult patients with sagittal plane deformities. We present an alternative strategy for focal deformity correction from a posterior‐only approach. The purpose of this study was to evaluate the feasibility and efficacy of a novel surgical technique called posterior open‐wedge diskectomy and anterior longitudinal ligament (ALL) release (POWAR). A cadaveric torso underwent POWARs at the L1‐L4 intervertebral disc spaces. Baseline measurements of end‐plate angle (EPA), anterior intervertebral disc height (ADH), and posterior intervertebral disc height (PDH) were obtained. These measurements were repeated after three stages of correction: posterior column compression alone, posterior column compression following Schwab grade 2 osteotomies, and posterior column compression following POWAR. A second cadaver underwent posterolateral spinal dissection to demonstrate the pertinent anatomical features relevant to this novel procedure. With each stage of correction, a sequential increase in EPA and ADH and a decrease in PDH were demonstrated. The large increase in ADH seen following POWAR confirmed successful release of the ALL. In situ investigation of the aorta and inferior vena cava following anterior exposure revealed no injury to the great vessels or surrounding structures. Ex vivo testing of the aorta and inferior vena cava took place at the L3‐4 level. This testing demonstrated no injury or tears to either vessel. POWAR is a new surgical technique that can provide an alternative to three‐column osteotomy for surgeons performing spinal reconstructions in adults through an open, posterior‐only approach. Clin. Anat. 32:348–353, 2019.
- 1 August 2018
- Published by Elsevier in The Spine Journal
- Vol. 18 (8) , 1374-1381
Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement
- 1 August 2018
- Published by Elsevier in The Spine Journal
- Vol. 18 (8) , 1374-1381
Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement